AzTrials
AzTrials

Aortic StenosisNCT01876420

The Medtronic CoreValve™ Evolut R™ CE Mark Clinical Study

A study testing The CoreValve™ Evolut R TAV™ system in people with Aortic Stenosis, run by Medtronic Cardiovascular at 6 sites in 3 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To assess the safety and clinical performance of the CoreValve™ Evolut R™ System. Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Stenosis
What is being tested?
The CoreValve™ Evolut R TAV™ system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
6 sitesin 3 countries
Study dates
Oct 2013to Oct 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Severe aortic stenosis, defined as aortic valve area of < 1.0 cm2 (or aortic valve area index of < 0.6 cm2/m2) by the continuity equation, AND mean gradient > 40 mmHg or maximal aortic valve velocity > 4.0 m/sec by resting echocardiogram.
  • Estimated 30 day mortality risk of > 15% by study center Heart Team assessment,33 OR at least two cardiovascular surgeons from the study center deny surgery because of prohibitive operative risk, estimated to be a combined >50% risk of irreversible mortality or morbidity.
  • Symptoms of aortic stenosis, and NYHA Functional Class II or greater.
  • The subject meets the legal minimum age to provide informed consent based on local regulatory requirements, and has provided written informed consent as approved by the EC/IRB of the respective clinical site.
  • The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits.

Who cannot join

  • Clinical exclusion criteria:
  • Subject has been offered SAVR but has declined.
  • Any condition considered a contraindication for placement of a bioprosthetic valve (e.g. subject is indicated for mechanical prosthetic valve).
  • Known hypersensitivity or contraindication to Nitinol.
  • Blood dyscrasias as defined: leukopenia (WBC <1000 mm3), thrombocytopenia (platelet count <50,000 cells/mm3), history of bleeding diathesis or coagulopathy, or hypercoagulable states.
  • Untreated clinically significant coronary artery disease requiring revascularization.
Show all 33Show fewer
  • Severe left ventricular dysfunction with left ventricular ejection fraction (LVEF) <20% by echocardiography, contrast ventriculography, or radionuclide ventriculography.
  • End stage renal disease requiring chronic dialysis of creatinine clearance < 20 cc/min.
  • Ongoing sepsis, including active endocarditis.
  • Any condition considered a contraindication to extracorporeal assistance.
  • Any percutaneous coronary or peripheral interventional procedure with a bare metal stent performed within 30 days prior to Heart Team assessment, or within six months prior to Heart Team assessment for procedures with a drug eluting stents.
  • Symptomatic carotid or vertebral artery disease or successful treatment of carotid stenosis within eight weeks of Heart Team Assessment .
  • Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support.
  • Recent (within 6 months of Heart Team assessment) cerebrovascular accident (CVA) or transient ischemic attack (TIA).
  • Gastrointestinal (GI) bleeding that would preclude anticoagulation.
  • Subject refuses a blood transfusion.
  • Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits).
  • Estimated life expectancy of less than 12 months due to associated non-cardiac co-morbid conditions.
  • Other medical, social, or psychological conditions that in the opinion of the Investigator precludes the subject from appropriate consent or adherence to the protocol required follow-ups exams.
  • Currently participating in an investigational drug or another device study (excluding registries).
  • Evidence of an acute myocardial infarction ≤30 days before the index procedure.
  • Need for emergency surgery for any reason.
  • Liver failure (Child-C).
  • Subject is pregnant or breast feeding.
  • Anatomical exclusion criteria:
  • Pre-existing prosthetic heart valve in any position.
  • Mixed aortic valve disease (aortic stenosis with moderate or severe aortic regurgitation).
  • Severe mitral regurgitation.
  • Severe tricuspid regurgitation.
  • Moderate or severe mitral stenosis.
  • Hypertrophic obstructive cardiomyopathy.
  • Echocardiographic or Multi-Slice Computed Tomography (MSCT) evidence of intracardiac mass thrombus or vegetation.
  • Congenital bicuspid or unicuspid valve verified by echocardiography.

Trial locations and contacts

6 sites in 3 countries.

6 sites in 3 countries

United Kingdom3 sites
  • Royal Victoria Hospital

    Belfast, BT12 6BA

  • Leeds General Infirmary

    Leeds, LS1 3EX

  • St. George's Hospital

    London

Other trials in United Kingdom

Australia2 sites
  • Epworth Hospital

    Melbourne, Victoria, 3004

  • Monash Medical Center

    Melbourne, Victoria

Other trials in Australia

New Zealand1 site
  • Waikato Hospital

    Hamilton

Other trials in New Zealand

About this study

To assess the safety and clinical performance of the CoreValve™ Evolut R™ System.

Read the detailed description

The study objectives are to assess the safety and clinical performance of the CoreValve™ Evolut R™ System in patients with severe symptomatic aortic stenosis who are considered at high through extreme risk for surgical aortic valve replacement. These objectives will be accomplished by a prospective clinical study involving up to 60 implanted subjects among up to six study centers.

Conditions
Aortic Stenosis
Being tested
The CoreValve™ Evolut R TAV™ system
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The CoreValve™ Evolut R TAV™ systemDevice

    Also called CoreValve™ EvolutR™ Transcatheter Ao Valve, EnveoR™ Delivery Catheter System w/ Enveo InLine™ Sheath, EnVeoR™ Loding System

    CoreValve™ Evolut R™ System which consists of the Evolut R™ Transcatheter Aortic Valve (26 \& 29 mm sizes), EnVeo R™ Delivery Catheter System with Enveo InLine™ Sheath, and EnVeo R™ Loading System

Study groups in NCT01876420
Study groupRoleWhat they receive
The CoreValve™ Evolut R TAV™ systemExperimentalCoreValve™ Evolut R™ System which consists of the Evolut R™ Transcatheter Aortic Valve (26 \& 29 mm sizes), EnVeo R™ Delivery Catheter System with Enveo InLine™ Sheath, and EnVeo R™ Loading System
Receives: Device: The CoreValve™ Evolut R TAV™ system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. All-cause Mortality Rate at 30 Days

    The All-cause mortality rate at 30 days per the VARC II recommendation of clinical endpoints for TAVI. More specifically:

    Cardiovascular mortality (Any of the following criteria)

    • Death due to proximate cardiac cause (e.g. myocardial infarction, cardiac tamponade, worsening heart failure)
    • Death caused by non-coronary vascular conditions such as neurological events, pulmonary embolism, ruptured aortic aneurysm, dissecting aneurysm, or other vascular disease
    • All procedure-related deaths, including those related to a complication of the procedure or treatment for a complication of the procedure
    • All valve-related deaths including structural or non-structural valve dysfunction or other valve-related adverse events
    • Sudden or unwitnessed death
    • Death of unknown cause Non-cardiovascular mortality
    • Any death in which the primary cause of death is clearly related to another condition (e.g. trauma, cancer, suicide)

    Measured: 30 days

  2. Stroke Rate (Disabling and Non-disabling) at 30 Days

    The Stroke rate (disabling and non-disabling) at 30 days per the VARC II definitions. Stroke is defined as an acute episode of focal or global neurological dysfunction caused by the brain, spinal cord, or retinal vascular injury as a result of haemorrhage or infarction. Stroke may be classified as ischaemic or haemorrhagic with appropriate subdefinitions. Ischaemic stroke is defined as an acute episode of focal cerebral, spinal, or retinal dysfunction caused by infarction of central nervous system tissue. Haemorrhagic stroke is defined as an acute episode of focal or global cerebral or spinal dysfunction caused by intraparenchymal, intraventricular, or subarachnoid haemorrhage. A stroke may be classified as 'undetermined' if there is insufficient information to allow the categorization as ischaemic or haemorrhagic.

    Measured: 30 days

  3. Device Success Rate at 24 Hours to Seven Days

    1. Device success rate at 24 hours to seven days, defined as:
    • Absence of procedural mortality, AND
    • Correct positioning of a single prosthetic heart valve into the proper anatomical location, AND
    • Intended performance of the prosthetic heart valve, defined as the absence of patient-prosthesis-mismatch and mean aortic valve gradient less than 20 mmHg (or peak velocity < 3 m/sec), AND absence of moderate or severe prosthetic valve regurgitation.
    1. The percentage of subjects with no more than mild aortic regurgitation at early post procedure echocardiogram (24 hours through seven days).

    Measured: 24 hours to seven days

Secondary outcomes (6)
  1. VARC II Combined Safety Endpoint at 30 Days

    The VARC II Combined Safety Endpoint at 30 days includes the following components: All-Cause Mortality, All Stroke, Life Threatening or Disabling Bleeding, Acute Kidney Injury: Stage 2 or 3, Coronary Artery Obstruction, Major Vascular Complication, and Valve-Related Dysfunction Requiring Repeat Procedure.

    Measured: 30 days

  2. Event Rates of the Individual Components of the VARC II Composite Safety Endpoint at 30 Days

    The Individual components of the VARC II composite safety endpoint at 30 days per the Kaplan Meier Event Rate (%).

    Measured: 30 days

  3. Hemodynamic Performance Metrics at 30 Days by Doppler Echocardiography - Mean Gradient

    The hemodynamic performance will be measured by the Mean Prosthetic Valve Gradient for 59 subjects, measured with the Doppler echocardiography.

    Measured: 30 days

  4. Hemodynamic Performance Metrics at 30 Days by Doppler Echocardiography - • Effective Orifice Area (EOA)

    Effective orifice area

    Measured: 30 days

  5. Hemodynamic Performance Metrics at 30 Days by Doppler Echocardiography - Total Aortic Regurgitation (Transvalvular & Paravalvular)

    Degree of Total prosthetic valve regurgitation (transvalvular \& paravalvular)

    Measured: 30 days

  6. Resheath or Recapture Success Rate (When Attempted), Where Successful Recapture is Defined as Evolut R™ TAV (Including the Frame) is Fully Resheathed Into the Capsule of the Delivery Catheter, as Verified by Fluoroscopy.

    Resheath or Recapture success rate (when attempted), where successful recapture is defined as Evolut R™ TAV (including the frame) is fully resheathed into the capsule of the delivery catheter, as verified by fluoroscopy. Resheathing or recapturing of the TAV was attempted on 15 subjects.

    Measured: Day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jun 2013 (estimated)
  2. Study startOct 2013
  3. Primary completionAug 2014
  4. Study completionOct 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01876420
Sponsor's protocol ID
MDT10093773DOC
Status last verified
Aug 2018
First submitted
5 Jun 2013
Last updated
22 Aug 2018
Data monitoring committee
No
Individual data sharing
No

Publications

  • Manoharan G, Walton AS, Brecker SJ, Pasupati S, Blackman DJ, Qiao H, Meredith IT. Treatment of Symptomatic Severe Aortic Stenosis With a Novel Resheathable Supra-Annular Self-Expanding Transcatheter Aortic Valve System. JACC Cardiovasc Interv. 2015 Aug 24;8(10):1359-1367. doi: 10.1016/j.jcin.2015.05.015.

    PubMed 26315740

Questions about this trial

What is this clinical trial studying?

A study testing The CoreValve™ Evolut R TAV™ system in people with Aortic Stenosis, run by Medtronic Cardiovascular at 6 sites in 3 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 33 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in United Kingdom, Australia, New Zealand. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 22 Aug 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

All-cause Mortality Rate at 30 Days (time frame: 30 days). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01876420, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Aug 2018; AzTrials last refreshed its copy on 6 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.