Clinical Evaluation of Cardiac Output Estimation Based on Pulse Wave Transit Time
A study testing Pulmonary Artery Catheter (PAC), Endotracheal Cardiac Output Monitor (ECOM) and Estimated Continuous Cardiac Output (esCCO) in people with Myocardial Infarction and Myocardial Ischemia, run by University of California, San Francisco at 2 sites in United States.
Trial summary
The specific aim of this study is to assess whether a device approved by the FDA to measure pulse oximetry can accurately estimate cardiac output. Read more about this study
- Who is it for?
- Ages 19 years and older
- Conditions the study is for
- Myocardial Infarction, Myocardial Ischemia
- What is being tested?
- Pulmonary Artery Catheter (PAC), Endotracheal Cardiac Output Monitor (ECOM) and Estimated Continuous Cardiac Output (esCCO)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 39 participants
- Where
- 2 sitesUnited States
- Study dates
- Dec 2012to Dec 2013
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 19 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients undergoing surgery where cardiac output will be measured with PAC and ECOM.
Who cannot join
- Failure to obtain consent.
Trial locations and contacts
2 sites in 1 country.
United States2 sites
Drexel University
Philadelphia, Pennsylvania, 19102
San Francisco VA Medical Center
San Francisco, California, 94121
About this study
The specific aim of this study is to assess whether a device approved by the FDA to measure pulse oximetry can accurately estimate cardiac output.
Read the detailed description
We will compare three methods for measuring cardiac output: esCCO, PAC, and ECOM. Cardiac output is an important physiological parameter that must be monitored closely during surgery and during an Intensive Care Unit (ICU) stay. The use of a pulmonary artery catheter (PAC) has been the gold standard for accurate cardiac output (CO) measurement. This method requires a catheter to be inserted into the pulmonary artery and cardiac output is indicated by the speed that a temperature gradient dissipates. While the use of the pulmonary artery catheter is widespread, inserting the pulmonary artery catheter is risky, time consuming and requires a high level of skill. For these reasons, new devices have been developed to measure cardiac output.
A second method typically used is called ECOM (Endotracheal Cardiac Output Monitor). A device is inserted into the patient's throat that calculates cardiac output by measuring how electricity moves through the patient's chest.
The third method, estimated Continuous Cardiac Output (esCCO), uses sensors placed on the patient's finger, arm and chest to calculate Pulse Wave Transit Time (PWTT); the time it takes for the heart beat pulse to travel through the patient's body. The esCCO system is FDA approved for safety and efficacy to measure noninvasive blood pressure and pulse oximetry. The purpose of this study is to assess whether the PSTT calculation provides a cardiac output measure that is comparable to the other methods.
This study is sponsored by Nihon Kohden Corporation who owns and manufactures the esCCO system.
- Conditions
- Myocardial Infarction, Myocardial Ischemia
- Being tested
- Pulmonary Artery Catheter (PAC), Endotracheal Cardiac Output Monitor (ECOM), Estimated Continuous Cardiac Output (esCCO)
- Keywords
- cardiac output, pulse oximetry, hemodynamics
- Medical subject headings
- Myocardial Infarction, Myocardial Ischemia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Pulmonary Artery Catheter (PAC)Device
A catheter is inserted into the pulmonary artery, through the internal jugular vein; cardiac output is indicated by the speed that a temperature gradient dissipates.
Endotracheal Cardiac Output Monitor (ECOM)Device
An FDA-approved medical device is inserted into the patient's throat; cardiac output is calculated by measuring how electricity moves through the chest.
Estimated Continuous Cardiac Output (esCCO)Device
Sensors are placed on the arm, finger and leg to calculate Pulse Wave Transit Time (PWTT); the time it takes for the pulse of the heartbeat to travel through the body.
| Study group | Role | What they receive |
|---|---|---|
| Cardiac output monitoring | Active comparator | Patients undergoing surgery who will have their cardiac output monitored by pulmonary artery catheter (PAC) and endotracheal cardiac output monitoring (ECOM) during surgery and during post-surgical recovery, will also have sensors placed on the arm, finger and leg to calculate pulse wave transit time (PWTT) using the estimated Continuous Cardiac Output system (ecCCO). Receives: Device: Pulmonary Artery Catheter (PAC); Device: Endotracheal Cardiac Output Monitor (ECOM); Device: Estimated Continuous Cardiac Output (esCCO) |
What is being measured
The primary outcome is the main question the study is designed to answer.
esCCO (Estimated Continuous Cardiac Output) Monitor
6 Measurements of cardiac output derived from pulse oximeter measurements using the esCCO system were taken at each time point. The measurements deemed valid under the criteria in the protocol were averaged to represent the reference value at that point. The mean and standard deviation reported consist of the reference values from all time points measured.
Data for this test were taken at the following timepoints:
- Start of Sterenotomy; 2. Before Bypass; 3. 30 Min after bypass; 4. Closure; 5. ICU arrival; 6. 6 hours in ICU; 7. 12 Hours in ICU; 8. 18 Hours in ICU (if PAC still in); 9. 24 Hours in ICU (If PAC still in)
Measured: During and after surgery, up to 24 hours
PAC (Pulmonary Artery Catheter).
Measurements of cardiac output derived from a PAC (pulmonary artery catheter) using the standard thermodilution technique. At each time point, at least 6 measurements were taken. If, in the opinion of the clinician taking the readings, some of these were in error, more readings were taken to ensure accuracy. In no case were more than 18 readings taken. The points deemed valid by the clinician were averaged to obtain the reference value for that time point. The mean and standard deviation reported consisted of the reference values from all time points measured.
Data for this test were taken at the following timepoints:
- Start of Sterenotomy; 2. Before Bypass; 3. 30 Min after bypass; 4. Closure; 5. ICU arrival; 6. 6 hours in ICU; 7. 12 Hours in ICU; 8. 18 Hours in ICU (if PAC still in); 9. 24 Hours in ICU (If PAC still in)
Measured: During and post-surgery, up to 24 hours
Cardiac Output as Measured by ECOM
Measurements of cardiac output derived from the Endotracheal Cardiac Output Monitor (ECOM): An FDA-approved medical device is inserted into the patient's throat; cardiac output is calculated by measuring how electricity moves through the chest.
Measured: During and post-surgery, up to 8 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Jun 2013 (estimated)
- Study startDec 2012
- Primary completionNov 2013
- Study completionDec 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Myocardial InfarctionStudies of the same condition, open and under way.
- More trials run by University of California, San FranciscoThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 39 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of California, San Francisco
- Sponsor type
- University, hospital or other
- Collaborators
- Northern California Institute of Research and Education, San Francisco Veterans Affairs Medical Center, Drexel University, Nihon Kohden
- Responsible party
- Sponsor
- Investigators
- Arthur Wallace, MD, PhD, Principal investigator, San Francisco Veteran's Admnistration Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01877941
- Sponsor's protocol ID
- UCSF 12-10139
- Acronym
- esCCO
- Status last verified
- Dec 2014
- First submitted
- 5 Dec 2012
- Last updated
- 1 Jan 2015
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 1 Jan 2015. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Evaluation of Cardiac Output Estimation Based on Pulse Wave Transit Time
- ClinicalTrials.gov ID
- NCT01877941
- Acronym / sponsor ID
- esCCO / UCSF 12-10139
- Conditions
- Myocardial Infarction, Myocardial Ischemia
- Keywords
- cardiac output, pulse oximetry, hemodynamics
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 39 participants (actual)
- Lead sponsor
- University of California, San FranciscoUniversity, hospital or other
- Collaborators
- Northern California Institute of Research and Education, San Francisco Veterans Affairs Medical Center, Drexel University, Nihon Kohden
- Study start
- Dec 2012
- Primary completion
- Nov 2013 (actual)
- Study completion
- Dec 2013 (actual)
- First posted
- 14 Jun 2013 (estimated)
- Results
- Posted 1 Jan 2015
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The specific aim of this study is to assess whether a device approved by the FDA to measure pulse oximetry can accurately estimate cardiac output.
Detailed description
We will compare three methods for measuring cardiac output: esCCO, PAC, and ECOM. Cardiac output is an important physiological parameter that must be monitored closely during surgery and during an Intensive Care Unit (ICU) stay. The use of a pulmonary artery catheter (PAC) has been the gold standard for accurate cardiac output (CO) measurement. This method requires a catheter to be inserted into the pulmonary artery and cardiac output is indicated by the speed that a temperature gradient dissipates. While the use of the pulmonary artery catheter is widespread, inserting the pulmonary artery catheter is risky, time consuming and requires a high level of skill. For these reasons, new devices have been developed to measure cardiac output.
A second method typically used is called ECOM (Endotracheal Cardiac Output Monitor). A device is inserted into the patient's throat that calculates cardiac output by measuring how electricity moves through the patient's chest.
The third method, estimated Continuous Cardiac Output (esCCO), uses sensors placed on the patient's finger, arm and chest to calculate Pulse Wave Transit Time (PWTT); the time it takes for the heart beat pulse to travel through the patient's body. The esCCO system is FDA approved for safety and efficacy to measure noninvasive blood pressure and pulse oximetry. The purpose of this study is to assess whether the PSTT calculation provides a cardiac output measure that is comparable to the other methods.
This study is sponsored by Nihon Kohden Corporation who owns and manufactures the esCCO system.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Cardiac output monitoring | Active comparator | Device: Pulmonary Artery Catheter (PAC), Device: Endotracheal Cardiac Output Monitor (ECOM), Device: Estimated Continuous Cardiac Output (esCCO)Patients undergoing surgery who will have their cardiac output monitored by pulmonary artery catheter (PAC) and endotracheal cardiac output monitoring (ECOM) during surgery and during post-surgical recovery, will also have sensors placed on the arm, finger and leg to calculate pulse wave transit time (PWTT) using the estimated Continuous Cardiac Output system (ecCCO). |
Who may qualify
- Ages
- 19 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Patients undergoing surgery where cardiac output will be measured with PAC and ECOM.
Key exclusion criteria (1 listed)
- Failure to obtain consent.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Pulmonary Artery Catheter (PAC)A catheter is inserted into the pulmonary artery, through the internal jugular vein; cardiac output is indicated by the speed that a temperature gradient dissipates. | Device | Cardiac output monitoring |
| Endotracheal Cardiac Output Monitor (ECOM)An FDA-approved medical device is inserted into the patient's throat; cardiac output is calculated by measuring how electricity moves through the chest. | Device | Cardiac output monitoring |
| Estimated Continuous Cardiac Output (esCCO)Sensors are placed on the arm, finger and leg to calculate Pulse Wave Transit Time (PWTT); the time it takes for the pulse of the heartbeat to travel through the body. | Device | Cardiac output monitoring |
Primary outcome
esCCO (Estimated Continuous Cardiac Output) Monitor
Time frame: During and after surgery, up to 24 hours
6 Measurements of cardiac output derived from pulse oximeter measurements using the esCCO system were taken at each time point. The measurements deemed valid under the criteria in the protocol were averaged to represent the reference value at that point. The mean and standard deviation reported consist of the reference values from all time points measured. Data for this test were taken at the following timepoints: 1. Start of Sterenotomy; 2. Before Bypass; 3. 30 Min after bypass; 4. Closure; 5. ICU arrival; 6. 6 hours in ICU; 7. 12 Hours in ICU; 8. 18 Hours in ICU (if PAC still in); 9. 24 Hours in ICU (If PAC still in)
PAC (Pulmonary Artery Catheter).
Time frame: During and post-surgery, up to 24 hours
Measurements of cardiac output derived from a PAC (pulmonary artery catheter) using the standard thermodilution technique. At each time point, at least 6 measurements were taken. If, in the opinion of the clinician taking the readings, some of these were in error, more readings were taken to ensure accuracy. In no case were more than 18 readings taken. The points deemed valid by the clinician were averaged to obtain the reference value for that time point. The mean and standard deviation reported consisted of the reference values from all time points measured. Data for this test were taken at the following timepoints: 1. Start of Sterenotomy; 2. Before Bypass; 3. 30 Min after bypass; 4. Closure; 5. ICU arrival; 6. 6 hours in ICU; 7. 12 Hours in ICU; 8. 18 Hours in ICU (if PAC still in); 9. 24 Hours in ICU (If PAC still in)
Cardiac Output as Measured by ECOM
Time frame: During and post-surgery, up to 8 hours
Measurements of cardiac output derived from the Endotracheal Cardiac Output Monitor (ECOM): An FDA-approved medical device is inserted into the patient's throat; cardiac output is calculated by measuring how electricity moves through the chest.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 Jan 2015.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Myocardial Infarction
RecruitingObservational study
SuperSaturated Oxygen Comprehensive Observational Registry
STEMI - ST Elevation Myocardial Infarction, AMI
Not yet recruitingPhase 4
Capital Offload-Shock
Hypervolemia, Cardiogenic Shock
RecruitingPhase 4
Efficacy and Safety of a Half-dose Bolus of r-SAK Prior to Primary PCI in ST-elevation Myocardial Infarction
ST Elevation Myocardial Infarction
Recruiting
ODSSEY-SCD_Identification Of Markers to preDict the rISk of Sudden Cardiac Death in Moderated LVEF in ischEmic cardiomyopathY
Myocardial Infarction (MI), Sudden Cardiac Death Due to Cardiac Arrhythmia
Enrolling by invitationPhase 3
Selatogrel Outcome Study in Suspected Acute Myocardial Infarction
Acute Myocardial Infarction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Arthur Wallace, MD, PhD principal investigator
San Francisco Veteran's Admnistration Medical Center
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Pulmonary Artery Catheter (PAC), Endotracheal Cardiac Output Monitor (ECOM) and Estimated Continuous Cardiac Output (esCCO) in people with Myocardial Infarction and Myocardial Ischemia, run by University of California, San Francisco at 2 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 1 Jan 2015. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 1 Jan 2015). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
esCCO (Estimated Continuous Cardiac Output) Monitor (time frame: During and after surgery, up to 24 hours). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jan 2015.