Anatomic Total Shoulder ArthroplastyRTINCT01905241
Use of Real Time Instrumentation (RTI) in Total Shoulder Arthroplasty
A study testing Anatomic TSA using RTI and Anatomic Total Shoulder Arthroplasty in people with Anatomic Total Shoulder Arthroplasty, run by The Cleveland Clinic at 1 site in United States.
Trial summary
Glenoid component loosening is the most common complication of total shoulder arthroplasty. Loosening is associated with malposition of the implant as well as the quality of the glenoid bone. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Anatomic Total Shoulder Arthroplasty
- What is being tested?
- Anatomic TSA using RTI and Anatomic Total Shoulder Arthroplasty
- Type of treatment
- Medical device, Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteUnited States
- Study dates
- Jul 2013to Dec 2013
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- To be eligible for inclusion, a primary anatomic total shoulder arthroplasty must be indicated for the patient.
Who cannot join
- Age less than 18.
Trial locations and contacts
1 site in 1 country.
United States1 site
Cleveland Clinic Orthopaedic and Rheumatologic Institute
Cleveland, Ohio, 44195
About this study
Official title: Use of Real Time Instrumentation (RTI) in Total Shoulder Arthroplasty: A Clinical Case Series
Glenoid component loosening is the most common complication of total shoulder arthroplasty. Loosening is associated with malposition of the implant as well as the quality of the glenoid bone. Past studies from our research group have addressed these problems by investigating novel surgical technologies to increase the accuracy of glenoid implant placement. Over the course of multiple IRB approved clinical trials, use of our preoperative planning software in combination with patient specific instrumentation (PSI) or intelligent reusable instrumentation (IRI) has proven to more accurately place the glenoid guide pin than conventional standard of care techniques.
Continuing the investigator's work, the investigators propose a clinical case series to evaluate a new surgical instrumentation technique that combines the features of PSI with the IRI technology that investigators have termed Real Time Instrumentation (RTI). Investigators will measure implant placement with RSA and 3D CT imaging. Investigators will measure pre-operative bone quality using quantitative CT to measure trabecular bone volume and correlate these findings with bone samples removed from the glenoid and measured by microCT and mechanical testing of the bone samples. These bone samples will be obtained as part of the routine preparation of the glenoid bone for implant placement. This bone tissue is normally removed and discarded as part of the standard of care for preparation of the bone for placement of the glenoid. Investigators have performed all of the work required to define both the safety of all components of the proposed study in the completed PSI study and the ongoing IRI study. Since application to the IRB for study of the IRI technology Custom Orthopaedic Solutions has received in April 2013 FDA approval for this technology.
Read the detailed description
The study will enroll 20 patients directly into the RTI group. Investigators will have two surgeons with experience in shoulder arthroplasty and the RTI and SmartBones technology. Investigators will require a minimum of five patients from any one surgeon. All patients will have the standard of care indications for an anatomic total shoulder arthroplasty and will give informed consent for both the surgery and participation in this study. Consent and enrollment will be obtained by the surgeon during a routine office evaluation. All patients will get standard of care pre operative x-rays and CT scan at least three weeks prior to surgery. Scan quality must meet study specific criteria and investigators expect that the scans will be performed at the Cleveland Clinic. The preoperative CT scan will be placed within our preoperative planning software (OrthoVis, Cleveland Clinic). The surgeon will use this software to assess the glenoid bone pathology and select the optimal implant and placement of that implant.
Patients will have standard of care indications for primary anatomic arthroplasty and be able to get a preoperative shoulder CT scan at the Cleveland Clinic or at an outside facility so long as the study includes the entire scapula and has 1 mm or thinner sections. These parameters are required for accurate preoperative planning as well as comparison with the post operative CT scans. Standard of care pre- and post-operative x-rays (AP and axillary views) will also be obtained and can be performed at the Cleveland Clinic or acquired from another health care facility. In all patients the standard x-rays and CT images provided by the radiology department will be available to the surgeon before and during the surgery.
Using the Smartbone surrogate model, the surgeon visually compares the exposed glenoid surface to the Smartbone model to ensure that the two match for size and shape. Any adjustments to the surgical site may be done by the surgeon to optimize the match between the model and the exposed glenoid surface. Prior to molding the bone cement, bone wax is wiped onto the model to ensure proper release of the cement mold. The surgeon will then mold bone cement around the pin in the Smartbone, capturing the trajectory of the pin and the unique contours of the glenoid rim. A small pin sleeve is inserted over the pin to be embedded within the cement model. Once the bone cement has cured, it is removed from the model and placed onto the patients glenoid surface. The bone morphology captured in the mold aligns the mold to the patient's anatomy. When surgeon feels that the model has good fit of the glenoid surface, he may continue with pin placement. After placement of the guide pin, the RTI mold is removed and the remainder of the procedure is completed using the implant manufacturer's equipment and standard surgical protocols. Any adjustments in guide pin position can be performed by the surgeon based upon surgical judgment. The surgeon can make any change needed and use any means or instrument that would otherwise be used for standard of care surgery to place the guide pin in any position that the surgeon believed to be best for the patient. If the pin is changed without the use of the RTI then the patient will be excluded from this study and the reasons for failure of the RTI technology to provide accurate pin placement based upon the surgeons sole determination of accuracy will be recorded and later analyzed as a failure to treat. These patients will not receive postoperative CT Scans as investigators would not be able to use the data.
A hollow core drill bit will be used to prepare the bone in a standard manner to obtain bone cores for study. Prior to implanting the glenoid component, three 1 mm tantalum beads will be inserted into the backside pegs of the component. Investigators have developed methods to place the beads in a manner that has been used by other investigators and validated in the investigators' own experience in 22 cases enrolled in the ongoing IRI clinical study. The desired implant will be placed into a holding device and using a drill guide, a 0.9 mm hole measuring 2 mm deep will be placed in each of the three peripheral pegs of the implant. A 1 mm tantalum bead (RSA biomedical, Umsa Sweden) supplied by the company will then be press fit into the component hole. The implant will then be placed in the glenoid, aligned with the previously drilled peg holes. As standard of care, these peg holes are cemented, thus locking the beads within the implant.
Using manufacturer (RSA biomedical, Umsa Sweden) provided beads and injector gun, four to five 1 mm tantalum beads will be placed in the coracoid, acromion and glenoid. Exact placement of these beads is at the discretion of the surgeon. Patient anatomy and operative exposure will guide the surgeon to the best places to inject the beads; however the surgeon will not be confined to a specific amount of beads in a specific location. The beads just need to be spread out amongst the coracoid, acromion, and glenoid to establish reference points for the RSA imaging. Prior studies looking at shoulder joint kinematics and implant position have used this methodology of bead placement with successful study related outcomes. Investigators have successfully placed bone beads in 22 patients currently treated in the ongoing IRI clinical study without any difficulty or adverse events during or after surgery.
Postoperatively, all patients will receive a CT with Metal Artifact Reduction (MAR)and RSA (if chosen) within 3 weeks of surgery. This will be a CT Scan performed with the patient's arm by the side in a supine position using metal artifact reduction techniques. In addition patients will receive a second CT scan and RSA imaging, provided they originally got RSA, performed 1 year (± 1 month) from surgery. The second CT scan will be performed with MAR techniques and with the patient in the lateral decubitus position with their arm in the overhead position, again using metal artifact reduction techniques. The second set of images, produced with a different body and arm position, also decreases metal artifact than those obtained with the arm placed by the side. This position cannot be comfortably obtained until 3- 6 months after surgery and require healing of the tissues and rehabilitation of the shoulder. Investigators have shown that in a small number of patients the glenoid component can shift in position within the first 3-6 months after surgery making the first CT Scan more accurate for implant position. The images obtained from the postoperative CT scans are placed back into the surgical software and the 3D reconstruction of the postoperative scapula with the implants is compared to the preoperative plan. Using measurement tools within the software, developed at the Cleveland Clinic, investigators will compare the position of the actual glenoid component placed in the patient with the desired position specified by the plan. The use and validation of these imaging methods to precisely measure implant position has been performed at the Cleveland Clinic in a prior IRB approved clinical trial (IRB 10-582).
Preoperatively, the high resolution quantitative CT will measure volumetric bone mineral density and the trabecular network of the glenoid. When available, this will be applied to the preoperative CT for those patients at Cleveland Clinic, Main Campus. Patients who have their preoperative CT completed at non Main Campus facilities will have the standard of care preoperative CT. This will be done at the same visit for the standard of care preoperative CT. Micro CT imaging, which creates a 3D reconstruction of the fine bone structure, in addition to microarchitecture analysis and mechanical testing, will allow assessment of the bone tissue taken from the bone core sample. Between the preoperative imaging and the bone tissue analysis, investigators will have data to properly determine the quality of the bone stock surrounding the implant. Further correlating these data with RSA and 3D CT imaging of implant movement, investigators can fully develop cause and effect of bone quality on glenoid component loosening.
The participating surgeons will be Drs. Joseph Iannotti and Eric Ricchetti. Patients may have surgery at either Cleveland Clinic main campus or at Euclid Hospital. If the procedure is performed at Euclid Hospital, post operative CT scan and RSA (if chosen), will need to be taken at main campus within 3 weeks. The patient will be made aware of this at the time of enrollment and consent.
By comparing the computer-generated preoperative plan to postoperative component placement, investigators will be looking at three outcomes. First, the overall difference in component placement between standard of care instrumentation, intelligent reusable instrument (IRB#12-997), patient specific instruments (IRB #10-582) and real time instrumentation will be compared. Secondly, investigators will compare the placement between the technologies within and between surgeons. Thirdly, investigators will evaluate the difference in implant position between technologies based on severity of pathology. The quality of the bone core sampled will be correlated to the possible loosening of the implants.
- Conditions
- Anatomic Total Shoulder Arthroplasty
- Being tested
- Anatomic TSA using RTI, Anatomic Total Shoulder Arthroplasty
- Keywords
- Anatomic total shoulder arthroplasty, Glenoid, Patient specific information, Computer simulation, Computer assisted tomography
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Anatomic TSA using RTIDevice
Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Real Time Instrumentation (RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy.
Anatomic Total Shoulder ArthroplastyProcedure or surgery
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same with the exception of the instrumentation used to place the guide pin for placement of the glenoid implant.
| Study group | Role | What they receive |
|---|---|---|
| Anatomic TSA using RTI | Experimental | During Anatomic Total Shoulder Arthroplasty (TSA), the surgeon will have use of the SmartBone and the bone cement mold made from the SmartBone (the RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy. Receives: Device: Anatomic TSA using RTI; Procedure: Anatomic Total Shoulder Arthroplasty |
What is being measured
The primary outcome is the main question the study is designed to answer.
Difference in Glenoid Component Placement (Inclination and Version)
The overall difference in component placement between Real Time Instrumentation, IRI (historical data) and standard of care instrumentation (historical data) and will be compared ((Inclination and Version).
Measured: Two weeks post surgery
Difference in Glenoid Component Placement (AP and SP)
The overall difference in component placement between Real Time Instrumentation, IRI (historical data) and standard of care instrumentation (historical data) and will be compared (Anteroposterior Position and Superoinferior Position).
Measured: Two weeks post surgery
Secondary outcomes (2)
Difference in Glenoid Component Position Within and Between Surgeons
Investigators will compare the placement of the glenoid component between RTI, IRI and standard of care technologies within and between the two surgeons.
Measured: Two weeks post surgery
Effect of Severity of Shoulder Pathology
Investigators will evaluate the difference in glenoid component position between RTI, IRI (historical data) and standard of care (historical data) technologies based on severity of shoulder pathology.
Measured: Two weeks post surgery
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Jul 2013 (estimated)
- Study startJul 2013
- Primary completionDec 2013
- Study completionDec 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Anatomic Total Shoulder ArthroplastyStudies of the same condition, open and under way.
- More trials run by The Cleveland ClinicThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- The Cleveland Clinic
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Joseph Iannotti, The Cleveland Clinic
- Investigators
- Joseph P Iannotti, MD PhD, Principal investigator, The Cleveland ClinicEric T Ricchetti, MD, Principal investigator, The Cleveland Clinic
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01905241
- Sponsor's protocol ID
- 13-652
- Acronym
- RTI
- Status last verified
- Apr 2021
- First submitted
- 18 Jul 2013
- Last updated
- 18 Jun 2021
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No: There is no plan to share IDP with other researchers.
Publications
Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, Iannotti JP. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012 Dec 5;94(23):2167-75. doi: 10.2106/JBJS.K.01209.
PubMed 23224387
Study at a glance
From the registry record, last updated by the sponsor on 18 Jun 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Use of Real Time Instrumentation (RTI) in Total Shoulder Arthroplasty: A Clinical Case Series
- ClinicalTrials.gov ID
- NCT01905241
- Acronym / sponsor ID
- RTI / 13-652
- Conditions
- Anatomic Total Shoulder Arthroplasty
- Keywords
- Anatomic total shoulder arthroplasty, Glenoid, Patient specific information, Computer simulation, Computer assisted tomography
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- The Cleveland ClinicUniversity, hospital or other
- Study start
- Jul 2013 (actual)
- Primary completion
- Dec 2013 (actual)
- Study completion
- Dec 2013 (actual)
- First posted
- 23 Jul 2013 (estimated)
- Results
- Posted 18 Jun 2021
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Glenoid component loosening is the most common complication of total shoulder arthroplasty. Loosening is associated with malposition of the implant as well as the quality of the glenoid bone. Past studies from our research group have addressed these problems by investigating novel surgical technologies to increase the accuracy of glenoid implant placement. Over the course of multiple IRB approved clinical trials, use of our preoperative planning software in combination with patient specific instrumentation (PSI) or intelligent reusable instrumentation (IRI) has proven to more accurately place the glenoid guide pin than conventional standard of care techniques.
Continuing the investigator's work, the investigators propose a clinical case series to evaluate a new surgical instrumentation technique that combines the features of PSI with the IRI technology that investigators have termed Real Time Instrumentation (RTI). Investigators will measure implant placement with RSA and 3D CT imaging. Investigators will measure pre-operative bone quality using quantitative CT to measure trabecular bone volume and correlate these findings with bone samples removed from the glenoid and measured by microCT and mechanical testing of the bone samples. These bone samples will be obtained as part of the routine preparation of the glenoid bone for implant placement. This bone tissue is normally removed and discarded as part of the standard of care for preparation of the bone for placement of the glenoid. Investigators have performed all of the work required to define both the safety of all components of the proposed study in the completed PSI study and the ongoing IRI study. Since application to the IRB for study of the IRI technology Custom Orthopaedic Solutions has received in April 2013 FDA approval for this technology.
Detailed description
The study will enroll 20 patients directly into the RTI group. Investigators will have two surgeons with experience in shoulder arthroplasty and the RTI and SmartBones technology. Investigators will require a minimum of five patients from any one surgeon. All patients will have the standard of care indications for an anatomic total shoulder arthroplasty and will give informed consent for both the surgery and participation in this study. Consent and enrollment will be obtained by the surgeon during a routine office evaluation. All patients will get standard of care pre operative x-rays and CT scan at least three weeks prior to surgery. Scan quality must meet study specific criteria and investigators expect that the scans will be performed at the Cleveland Clinic. The preoperative CT scan will be placed within our preoperative planning software (OrthoVis, Cleveland Clinic). The surgeon will use this software to assess the glenoid bone pathology and select the optimal implant and placement of that implant.
Patients will have standard of care indications for primary anatomic arthroplasty and be able to get a preoperative shoulder CT scan at the Cleveland Clinic or at an outside facility so long as the study includes the entire scapula and has 1 mm or thinner sections. These parameters are required for accurate preoperative planning as well as comparison with the post operative CT scans. Standard of care pre- and post-operative x-rays (AP and axillary views) will also be obtained and can be performed at the Cleveland Clinic or acquired from another health care facility. In all patients the standard x-rays and CT images provided by the radiology department will be available to the surgeon before and during the surgery.
Using the Smartbone surrogate model, the surgeon visually compares the exposed glenoid surface to the Smartbone model to ensure that the two match for size and shape. Any adjustments to the surgical site may be done by the surgeon to optimize the match between the model and the exposed glenoid surface. Prior to molding the bone cement, bone wax is wiped onto the model to ensure proper release of the cement mold. The surgeon will then mold bone cement around the pin in the Smartbone, capturing the trajectory of the pin and the unique contours of the glenoid rim. A small pin sleeve is inserted over the pin to be embedded within the cement model. Once the bone cement has cured, it is removed from the model and placed onto the patients glenoid surface. The bone morphology captured in the mold aligns the mold to the patient's anatomy. When surgeon feels that the model has good fit of the glenoid surface, he may continue with pin placement. After placement of the guide pin, the RTI mold is removed and the remainder of the procedure is completed using the implant manufacturer's equipment and standard surgical protocols. Any adjustments in guide pin position can be performed by the surgeon based upon surgical judgment. The surgeon can make any change needed and use any means or instrument that would otherwise be used for standard of care surgery to place the guide pin in any position that the surgeon believed to be best for the patient. If the pin is changed without the use of the RTI then the patient will be excluded from this study and the reasons for failure of the RTI technology to provide accurate pin placement based upon the surgeons sole determination of accuracy will be recorded and later analyzed as a failure to treat. These patients will not receive postoperative CT Scans as investigators would not be able to use the data.
A hollow core drill bit will be used to prepare the bone in a standard manner to obtain bone cores for study. Prior to implanting the glenoid component, three 1 mm tantalum beads will be inserted into the backside pegs of the component. Investigators have developed methods to place the beads in a manner that has been used by other investigators and validated in the investigators' own experience in 22 cases enrolled in the ongoing IRI clinical study. The desired implant will be placed into a holding device and using a drill guide, a 0.9 mm hole measuring 2 mm deep will be placed in each of the three peripheral pegs of the implant. A 1 mm tantalum bead (RSA biomedical, Umsa Sweden) supplied by the company will then be press fit into the component hole. The implant will then be placed in the glenoid, aligned with the previously drilled peg holes. As standard of care, these peg holes are cemented, thus locking the beads within the implant.
Using manufacturer (RSA biomedical, Umsa Sweden) provided beads and injector gun, four to five 1 mm tantalum beads will be placed in the coracoid, acromion and glenoid. Exact placement of these beads is at the discretion of the surgeon. Patient anatomy and operative exposure will guide the surgeon to the best places to inject the beads; however the surgeon will not be confined to a specific amount of beads in a specific location. The beads just need to be spread out amongst the coracoid, acromion, and glenoid to establish reference points for the RSA imaging. Prior studies looking at shoulder joint kinematics and implant position have used this methodology of bead placement with successful study related outcomes. Investigators have successfully placed bone beads in 22 patients currently treated in the ongoing IRI clinical study without any difficulty or adverse events during or after surgery.
Postoperatively, all patients will receive a CT with Metal Artifact Reduction (MAR)and RSA (if chosen) within 3 weeks of surgery. This will be a CT Scan performed with the patient's arm by the side in a supine position using metal artifact reduction techniques. In addition patients will receive a second CT scan and RSA imaging, provided they originally got RSA, performed 1 year (± 1 month) from surgery. The second CT scan will be performed with MAR techniques and with the patient in the lateral decubitus position with their arm in the overhead position, again using metal artifact reduction techniques. The second set of images, produced with a different body and arm position, also decreases metal artifact than those obtained with the arm placed by the side. This position cannot be comfortably obtained until 3- 6 months after surgery and require healing of the tissues and rehabilitation of the shoulder. Investigators have shown that in a small number of patients the glenoid component can shift in position within the first 3-6 months after surgery making the first CT Scan more accurate for implant position. The images obtained from the postoperative CT scans are placed back into the surgical software and the 3D reconstruction of the postoperative scapula with the implants is compared to the preoperative plan. Using measurement tools within the software, developed at the Cleveland Clinic, investigators will compare the position of the actual glenoid component placed in the patient with the desired position specified by the plan. The use and validation of these imaging methods to precisely measure implant position has been performed at the Cleveland Clinic in a prior IRB approved clinical trial (IRB 10-582).
Preoperatively, the high resolution quantitative CT will measure volumetric bone mineral density and the trabecular network of the glenoid. When available, this will be applied to the preoperative CT for those patients at Cleveland Clinic, Main Campus. Patients who have their preoperative CT completed at non Main Campus facilities will have the standard of care preoperative CT. This will be done at the same visit for the standard of care preoperative CT. Micro CT imaging, which creates a 3D reconstruction of the fine bone structure, in addition to microarchitecture analysis and mechanical testing, will allow assessment of the bone tissue taken from the bone core sample. Between the preoperative imaging and the bone tissue analysis, investigators will have data to properly determine the quality of the bone stock surrounding the implant. Further correlating these data with RSA and 3D CT imaging of implant movement, investigators can fully develop cause and effect of bone quality on glenoid component loosening.
The participating surgeons will be Drs. Joseph Iannotti and Eric Ricchetti. Patients may have surgery at either Cleveland Clinic main campus or at Euclid Hospital. If the procedure is performed at Euclid Hospital, post operative CT scan and RSA (if chosen), will need to be taken at main campus within 3 weeks. The patient will be made aware of this at the time of enrollment and consent.
By comparing the computer-generated preoperative plan to postoperative component placement, investigators will be looking at three outcomes. First, the overall difference in component placement between standard of care instrumentation, intelligent reusable instrument (IRB#12-997), patient specific instruments (IRB #10-582) and real time instrumentation will be compared. Secondly, investigators will compare the placement between the technologies within and between surgeons. Thirdly, investigators will evaluate the difference in implant position between technologies based on severity of pathology. The quality of the bone core sampled will be correlated to the possible loosening of the implants.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Anatomic TSA using RTI | Experimental | Device: Anatomic TSA using RTI, Procedure: Anatomic Total Shoulder ArthroplastyDuring Anatomic Total Shoulder Arthroplasty (TSA), the surgeon will have use of the SmartBone and the bone cement mold made from the SmartBone (the RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- To be eligible for inclusion, a primary anatomic total shoulder arthroplasty must be indicated for the patient.
Key exclusion criteria (1 listed)
- Age less than 18.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Anatomic TSA using RTIAnatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Real Time Instrumentation (RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy. | Device | Anatomic TSA using RTI |
| Anatomic Total Shoulder ArthroplastyAnatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same with the exception of the instrumentation used to place the guide pin for placement of the glenoid implant. | Procedure or surgery | Anatomic TSA using RTI |
Primary outcome
Difference in Glenoid Component Placement (Inclination and Version)
Time frame: Two weeks post surgery
The overall difference in component placement between Real Time Instrumentation, IRI (historical data) and standard of care instrumentation (historical data) and will be compared ((Inclination and Version).
Difference in Glenoid Component Placement (AP and SP)
Time frame: Two weeks post surgery
The overall difference in component placement between Real Time Instrumentation, IRI (historical data) and standard of care instrumentation (historical data) and will be compared (Anteroposterior Position and Superoinferior Position).
2 secondary outcomes
Difference in Glenoid Component Position Within and Between Surgeons
Time frame: Two weeks post surgery
Effect of Severity of Shoulder Pathology
Time frame: Two weeks post surgery
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Jun 2021.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Background: PubMed 23224387Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, Iannotti JP. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012 Dec 5;94(23):2167-75. doi: 10.2106/JBJS.K.01209.
- Individual participant dataSharing planned: No. There is no plan to share IDP with other researchers.
Related trials for Anatomic Total Shoulder Arthroplasty
Not yet recruiting
A Trial to Assess the Safety and Effectiveness of an Anatomic Total Shoulder System
Shoulder Arthroplasty, Total Shoulder Arthroplasty
Not yet recruitingObservational study
Three Year Outcomes After Shoulder Arthroplasty
Arthroplasty, Replacement, Shoulder, Arthritis Shoulder
Active, not recruitingObservational study
Anatomical Shoulder Domelock System Study
Avascular Necrosis, Revision Surgery
Recruiting
A Study Comparing Shoulder Replacement Techniques For Patients With Shoulder Arthritis And An Intact Rotator Cuff
Shoulder Arthritis
Recruiting
Innovating Physical Therapy: A Pilot Study on Band Connect's Impact on Compliance, Satisfaction, and Revenue
Rotator Cuff Tears, Anatomic Total Shoulder Arthroplasty
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joseph P Iannotti, MD PhD principal investigator
The Cleveland Clinic
Eric T Ricchetti, MD principal investigator
The Cleveland Clinic
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Anatomic TSA using RTI and Anatomic Total Shoulder Arthroplasty in people with Anatomic Total Shoulder Arthroplasty, run by The Cleveland Clinic at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 18 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 18 Jun 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Difference in Glenoid Component Placement (Inclination and Version) (time frame: Two weeks post surgery). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01905241, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jun 2021.