Peripheral Arterial Occlusive DiseaseSRANSNCT01938924
Surgical Revascularisation and Nerve Stimulation Trial
A study testing GekoTM in people with Peripheral Arterial Occlusive Disease, run by Hull University Teaching Hospitals NHS Trust at 1 site in United Kingdom.
Trial summary
A study to investigate if the gekoTM device improves flow through vascular bypass grafts Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Peripheral Arterial Occlusive Disease
- What is being tested?
- GekoTM
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 0 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- Sep 2013to Dec 2014
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age ≥18 years,
- Undergoing infra-inguinal vein bypass graft.
- Intact cutaneous sensations to nociception in the lower limb, as determined by the investigator.
- Intact healthy skin at site of application.
- On effective contraception if sexually active - oral contraceptive pill (> 3 months use), condoms, intrauterine contraceptive device, depot injection.
- Able to understand the Patient Information Sheet and capable and willing to give informed consent and follow the protocol requirements
Who cannot join
- History of haematological disorder or DVT within the preceding 6 months,
- Pregnant or planning to become pregnant during study duration,
- Pacemakers or implantable defibrillators,
- Use of any other neuro-modulation device,
- Current use of TENS in pelvic region, back or legs,
- Use of investigational drug/device therapy within past 4 weeks that may interfere with this study,
Show all 12Show fewer
- Significant varicose veins or lower limb ulceration.
- Recent surgery (such as abdominal, gynaecological, hip knee replacement).
- Recent trauma to lower limbs.
- Chronic Obesity (BMI Index >34).
- Any medication judged to be significant by the Principal Investigator.
- Any significant illness during the four (4) weeks preceding the screening period of the study.
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site
Hull Royal Infirmary
Hull, EastRiding of Yorkshire, HU3 2JZ
About this study
Official title: A Randomised Control Trial to Establish if Use of the gekoTM (Trademark) Post Infra-inguinal Surgical Vein Revascularisation Increases Flow Through the Graft
A study to investigate if the gekoTM device improves flow through vascular bypass grafts
Read the detailed description
The geko™ device, (CE 558928;British Standards Institute notified body 0086), wearable, discrete, self-contained stimulation unit that adheres to the skin (see www.gekodevices.com). The, geko™ produces small electrical impulses that gently activate the common peroneal nerve within the popliteal fossa, behind the knee, in turn activating the venous muscle pumps of the calf and foot. Substantive increases in lower limb blood flow have been demonstrated to improve arterial, venous and microcirculatory blood flow with no reported morbidity.
RATIONALE Early infra-inguinal graft failure, i.e. occurring within 30 days of surgery occurs in approximately 5% of patients16. It is known that the predominant cause of this is thrombosis. The geko™ is an electrical device placed over the common peroneal nerve alongside the knee. The device activates muscle contraction in the peronei using low intensity, low frequency (1Hz) stimulation. The muscle contraction expresses blood from the deep venous system. Application of the stimulation device over the peroneal nerve is suitable for practical purposes. Previous studies have shown that the geko™ substantively increases arterial, venous and microcirculatory blood flow in healthy volunteers. A significant decrease in Tissue Plasminogen Activator antigen has also been demonstrated which indicates increased fibrinolytic activity3. Application of the geko™ device should therefore decrease stasis and increase flow though the graft and as such reduce the risk of thrombosis and as such graft failure.
Study:
Environmental Conditions The examinations will be carried out in a designated temperature controlled clinical room in the Vascular Lab at Hull Royal Infirmary. Participants will be required to abstain from vigorous exercise, nicotine, caffeine and fatty foods prior to their examination. They will be required to wear light garments with their legs exposed.
The geko™ device will be applied to outer/ posterior aspect of the knee whilst the subjects are semi-recumbent, with their knees flexed. The participants will be given 30 minutes in the quiet, environmentally controlled room prior to commencement of measurement to enable equilibration.
Assessments Participants will complete the McGill Pain questionnaire prior to device activation Participants will have the geko™ device applied whilst semi-recumbent with their knees flexed. The intensity will be increased until visible muscle stimulation is evident (concentric isotonic contractions) or until patient tolerance is reached
- Laser Doppler imaging will be used to assess microcirculation flow on the dorsum of both feet at:
- Baseline (rest)
- 5 minute intervals while the geko™ device is active
- 30 minutes following removal of the device Laser Doppler flowmetry is a reproducible, objective, non-invasive measurement which can be used to evaluate real time cutaneous blood flow. The low powered light is conducted via glass fibres to a probe attached to the skin and is scattered by the movement of blood cells inducing a Doppler shift. This allows information on flux and cell velocity to be recorded. The system to be used for this trial is the Moor Instruments DT-4 mains unit with integrated bilateral lasers.
- Ultrasound Doppler arterial flow velocity and blood volume flow within the femoral artery (mid thigh) bilaterally at:
- Baseline (rest)
- 30 minutes while the device is active
- Ultrasound Doppler flow velocity in femoral vein (mid thigh) bilaterally at:
- Baseline (rest)
- 40 minutes while the geko is active
- Vicorder measurements of arterial stiffness, pulse wave velocity and stroke volume at:
- Baseline (rest)
- Immediately following removal/ deactivation of the device
- Vascular Endothelial Growth Factor (VEGF), Tissue Plasminogen Activator antigen (TPA antigen), Full blood count (FBC) and Plasminogen activator inhibitor-1 (PAI-1): 15 mls of blood to be taken from both femoral veins at:
- Baseline (rest)
- 45 minutes while the geko™ device is active ELISA analysis will be carried out on samples (see appendix). Vascular Endothelial Growth Factor - Therapies which can lead to the development of new, collateral blood vessels, are of particular interest in the field of peripheral arterial disease where narrowing or blockages in existing blood vessels result in tissue ischaemia. Vascular endothelial growth factor (VEGF) is a signal protein produced by cells that stimulates the growth of new blood vessels from pre-existing vessels. Several previous studies have shown that electrical stimulation increases VEGF levels and in turn increases vessel density in muscles.
Tissue plasminogen activator (tPA) is a protein involved in the breakdown of blood clots. As a result it has therapeutic uses in clinical medicine to treat thromboses and emboli. Electrical stimulation has been previously shown to provoke an acute release of tPA into the circulation, although it appears that this response decreases with repeated stimulations. Use of the geko™ device has been shown to result in a significant decrease in Tissue Plasminogen Activator (tPA) antigen which is indicative of increased fibrinolytic activity.
Plasminogen activator inhibitor- 1 (PAI-1) is the primary inhibitor of plasminogen activators and inactivates tissue plasminogen activator (t-PA) and urokinase-type plasminogen activator (u-PA). PAI-1 is an important inhibitor of the fibrinolytic system, and elevated levels could suppress fibrinolysis and result in an increased risk of thrombosis. Increased PAI-1 levels have been shown to be associated with a number of atherosclerotic risk factors, PAI-1 has been shown to act as a prothrombic factor in both arterial and venous thromboembolic disorders.
- Ankle Brachial Pressure Index at baseline and post removal of geko™- utilising both Posterior Tibial Artery and Anterior Tibial Artery
- Maximum calf circumference at baseline and post removal of geko™
- Three blood pressure and heart rate measurements will be taken bilaterally at baseline and @ 30 minutes while the device is active. The mean of the three values will be used for comparison.
- Patient tolerance/ acceptability + Nurse tolerance/ ease of application Questionnaire using Visual Analogue Scores and Verbal Rating Scores to be completed following removal of geko™ device (see appendix)
- The McGill Pain Questionnaire to be completed following device removal
- Conditions
- Peripheral Arterial Occlusive Disease
- Being tested
- GekoTM
- Medical subject headings
- Peripheral Arterial Occlusive Disease 1
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
GekoTMDevice
electrical neuromuscular stimulation
| Study group | Role | What they receive |
|---|---|---|
| No intervention | No intervention | No intervention |
| GekoTM | Active comparator | geko applied to bypass limb Receives: Device: GekoTM |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in arterial blood volume flow in the bypass graft measured by ultrasound.
Measured by ultrasound duplex
Measured: 1 day
Secondary outcomes (7)
To assess effect on blood flow in the superficial femoral vein
Measured by ultrasound doppler
Measured: 1 day
To assess effect on microcirculation
Measured using laser Doppler flowmetry
Measured: 1 day
To assess effect on pulse wave velocity, cardiac output and stroke volume
Measured using using the Vicorder device.
Measured: 1 day
To assess effect on levels of VEGF, PAI-1 and tPA antigen.
Blood tests and ELISA
Measured: 1 day
To assess the impact of gekoTM device on pain score utilising the McGill Pain score
Validated pain questionnaire
Measured: 1 day
Patient tolerance/ acceptability
Questionnaire using Visual Analogue Scores and Verbal Rating Scores to be completed following removal of geko™ device
Measured: 1 day
To assess effect on calf circumference
Measurement pre and post device
Measured: 1 day
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Sep 2013 (estimated)
- Study startSep 2013
- Primary completionDec 2014
- Study completionDec 2014
Why it stopped: No funding
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Peripheral Arterial Occlusive DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- Hull University Teaching Hospitals NHS Trust
- Sponsor type
- Other government
- Responsible party
- Sponsor
- Investigators
- Rachel Barnes, MRCS, MA, Study chair, Hull Royal Infirmary
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01938924
- Sponsor's protocol ID
- 12/YH/0480
- Acronym
- SRANS
- Status last verified
- Jul 2019
- First submitted
- 5 Sep 2013
- Last updated
- 15 Jul 2019
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 15 Jul 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomised Control Trial to Establish if Use of the gekoTM (Trademark) Post Infra-inguinal Surgical Vein Revascularisation Increases Flow Through the Graft
- ClinicalTrials.gov ID
- NCT01938924
- Acronym / sponsor ID
- SRANS / 12/YH/0480
- Conditions
- Peripheral Arterial Occlusive Disease
- Study type
- Interventional
- Recruitment status
- WithdrawnReason stopped: No funding
- Enrolment
- 0 participants (actual)
- Lead sponsor
- Hull University Teaching Hospitals NHS TrustOther government
- Study start
- Sep 2013
- Primary completion
- Dec 2014 (actual)
- Study completion
- Dec 2014 (actual)
- First posted
- 10 Sep 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
A study to investigate if the gekoTM device improves flow through vascular bypass grafts
Detailed description
The geko™ device, (CE 558928;British Standards Institute notified body 0086), wearable, discrete, self-contained stimulation unit that adheres to the skin (see www.gekodevices.com). The, geko™ produces small electrical impulses that gently activate the common peroneal nerve within the popliteal fossa, behind the knee, in turn activating the venous muscle pumps of the calf and foot. Substantive increases in lower limb blood flow have been demonstrated to improve arterial, venous and microcirculatory blood flow with no reported morbidity.
RATIONALE Early infra-inguinal graft failure, i.e. occurring within 30 days of surgery occurs in approximately 5% of patients16. It is known that the predominant cause of this is thrombosis. The geko™ is an electrical device placed over the common peroneal nerve alongside the knee. The device activates muscle contraction in the peronei using low intensity, low frequency (1Hz) stimulation. The muscle contraction expresses blood from the deep venous system. Application of the stimulation device over the peroneal nerve is suitable for practical purposes. Previous studies have shown that the geko™ substantively increases arterial, venous and microcirculatory blood flow in healthy volunteers. A significant decrease in Tissue Plasminogen Activator antigen has also been demonstrated which indicates increased fibrinolytic activity3. Application of the geko™ device should therefore decrease stasis and increase flow though the graft and as such reduce the risk of thrombosis and as such graft failure.
Study:
Environmental Conditions The examinations will be carried out in a designated temperature controlled clinical room in the Vascular Lab at Hull Royal Infirmary. Participants will be required to abstain from vigorous exercise, nicotine, caffeine and fatty foods prior to their examination. They will be required to wear light garments with their legs exposed.
The geko™ device will be applied to outer/ posterior aspect of the knee whilst the subjects are semi-recumbent, with their knees flexed. The participants will be given 30 minutes in the quiet, environmentally controlled room prior to commencement of measurement to enable equilibration.
Assessments Participants will complete the McGill Pain questionnaire prior to device activation Participants will have the geko™ device applied whilst semi-recumbent with their knees flexed. The intensity will be increased until visible muscle stimulation is evident (concentric isotonic contractions) or until patient tolerance is reached
- Laser Doppler imaging will be used to assess microcirculation flow on the dorsum of both feet at:
- Baseline (rest)
- 5 minute intervals while the geko™ device is active
- 30 minutes following removal of the device Laser Doppler flowmetry is a reproducible, objective, non-invasive measurement which can be used to evaluate real time cutaneous blood flow. The low powered light is conducted via glass fibres to a probe attached to the skin and is scattered by the movement of blood cells inducing a Doppler shift. This allows information on flux and cell velocity to be recorded. The system to be used for this trial is the Moor Instruments DT-4 mains unit with integrated bilateral lasers.
- Ultrasound Doppler arterial flow velocity and blood volume flow within the femoral artery (mid thigh) bilaterally at:
- Baseline (rest)
- 30 minutes while the device is active
- Ultrasound Doppler flow velocity in femoral vein (mid thigh) bilaterally at:
- Baseline (rest)
- 40 minutes while the geko is active
- Vicorder measurements of arterial stiffness, pulse wave velocity and stroke volume at:
- Baseline (rest)
- Immediately following removal/ deactivation of the device
- Vascular Endothelial Growth Factor (VEGF), Tissue Plasminogen Activator antigen (TPA antigen), Full blood count (FBC) and Plasminogen activator inhibitor-1 (PAI-1): 15 mls of blood to be taken from both femoral veins at:
- Baseline (rest)
- 45 minutes while the geko™ device is active ELISA analysis will be carried out on samples (see appendix). Vascular Endothelial Growth Factor - Therapies which can lead to the development of new, collateral blood vessels, are of particular interest in the field of peripheral arterial disease where narrowing or blockages in existing blood vessels result in tissue ischaemia. Vascular endothelial growth factor (VEGF) is a signal protein produced by cells that stimulates the growth of new blood vessels from pre-existing vessels. Several previous studies have shown that electrical stimulation increases VEGF levels and in turn increases vessel density in muscles.
Tissue plasminogen activator (tPA) is a protein involved in the breakdown of blood clots. As a result it has therapeutic uses in clinical medicine to treat thromboses and emboli. Electrical stimulation has been previously shown to provoke an acute release of tPA into the circulation, although it appears that this response decreases with repeated stimulations. Use of the geko™ device has been shown to result in a significant decrease in Tissue Plasminogen Activator (tPA) antigen which is indicative of increased fibrinolytic activity.
Plasminogen activator inhibitor- 1 (PAI-1) is the primary inhibitor of plasminogen activators and inactivates tissue plasminogen activator (t-PA) and urokinase-type plasminogen activator (u-PA). PAI-1 is an important inhibitor of the fibrinolytic system, and elevated levels could suppress fibrinolysis and result in an increased risk of thrombosis. Increased PAI-1 levels have been shown to be associated with a number of atherosclerotic risk factors, PAI-1 has been shown to act as a prothrombic factor in both arterial and venous thromboembolic disorders.
- Ankle Brachial Pressure Index at baseline and post removal of geko™- utilising both Posterior Tibial Artery and Anterior Tibial Artery
- Maximum calf circumference at baseline and post removal of geko™
- Three blood pressure and heart rate measurements will be taken bilaterally at baseline and @ 30 minutes while the device is active. The mean of the three values will be used for comparison.
- Patient tolerance/ acceptability + Nurse tolerance/ ease of application Questionnaire using Visual Analogue Scores and Verbal Rating Scores to be completed following removal of geko™ device (see appendix)
- The McGill Pain Questionnaire to be completed following device removal
Study design
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| No intervention | No intervention | –No intervention |
| GekoTM | Active comparator | Device: GekoTMgeko applied to bypass limb |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- Age ≥18 years,
- Undergoing infra-inguinal vein bypass graft.
- Intact cutaneous sensations to nociception in the lower limb, as determined by the investigator.
- Intact healthy skin at site of application.
- On effective contraception if sexually active - oral contraceptive pill (> 3 months use), condoms, intrauterine contraceptive device, depot injection.
Key exclusion criteria (12 listed)
- History of haematological disorder or DVT within the preceding 6 months,
- Pregnant or planning to become pregnant during study duration,
- Pacemakers or implantable defibrillators,
- Use of any other neuro-modulation device,
- Current use of TENS in pelvic region, back or legs,
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| GekoTMelectrical neuromuscular stimulation | Device | GekoTM |
Primary outcome
Change in arterial blood volume flow in the bypass graft measured by ultrasound.
Time frame: 1 day
Measured by ultrasound duplex
7 secondary outcomes
To assess effect on blood flow in the superficial femoral vein
Time frame: 1 day
To assess effect on microcirculation
Time frame: 1 day
To assess effect on pulse wave velocity, cardiac output and stroke volume
Time frame: 1 day
To assess effect on levels of VEGF, PAI-1 and tPA antigen.
Time frame: 1 day
To assess the impact of gekoTM device on pain score utilising the McGill Pain score
Time frame: 1 day
Patient tolerance/ acceptability
Time frame: 1 day
To assess effect on calf circumference
Time frame: 1 day
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Jul 2019.
Related trials for Peripheral Arterial Occlusive Disease
Recruiting
EVERO Drug-coated Balloon (DCB) Randomized Trial
Peripheral Vascular Disease, Peripheral Arterial Disease
Active, not recruiting
SELUTION4SFA Trial
Peripheral Arterial Disease, Superficial Femoral Artery Stenosis
RecruitingPhase 3
Efficacy and Safety of Orforglipron in Participants With Peripheral Artery Disease
Peripheral Arterial Disease
Recruiting
REVASC-PAD: REstricted VASCular Exercise for Peripheral Arterial Disease - A Feasibility Study at University of Tennessee Medical Center
Peripheral Arterial Disease
Not yet recruitingPhase 2
REducing Systemic Inflammation With LOw-dose Colchicine to ImproVE Cardiovascular Calcification in Chronic Kidney Disease: A Pilot Randomized Open-Label Trial
Chronic Kidney Disease Mineral and Bone Disorder, Cognitive Function
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Rachel Barnes, MRCS, MA study chair
Hull Royal Infirmary
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing GekoTM in people with Peripheral Arterial Occlusive Disease, run by Hull University Teaching Hospitals NHS Trust at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 15 Jul 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in arterial blood volume flow in the bypass graft measured by ultrasound. (time frame: 1 day). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jul 2019.