AzTrials
AzTrials

Asbestos-exposed WorkersPhase 4NCT01955018

Comparison of the Ultra-low-dose Veo Algorithm With the Gold Standard Filtered Back Projection for Detecting Pulmonary Asbestos-related Conditions

A Phase 4 study testing New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) in people with Asbestos-exposed Workers, run by University Hospital, Clermont-Ferrand at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Asbestos fibers were intensively used throughout the 20th century and remain prevalent in developing countries. However, asbestos exposure induces a variety of benign and malignant pleural and lung diseases. The most common asbestos-induced neoplasm is lung cancer. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Asbestos-exposed Workers
What is being tested?
New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
90 participants
Where
1 siteFrance
Study dates
Sep 2012to May 2013
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • asbestos-exposed workers
  • ability to give a written informed consent

Who cannot join

  • - previous history of cancer
  • previous history of thoracic surgery
  • other interstitial pathology known

Trial locations and contacts

1 site in 1 country.

France1 site
  • CHU Clermont-Ferrand

    Clermont-Ferrand, 63003

Other trials in France

About this study

Asbestos fibers were intensively used throughout the 20th century and remain prevalent in developing countries. However, asbestos exposure induces a variety of benign and malignant pleural and lung diseases. The most common asbestos-induced neoplasm is lung cancer. Moreover, thin-section computed tomography (CT) is more sensitive than a chest x-ray for detecting early asbestos-related conditions. Increased exposure to radiation underpins the consequences of cancer induction. However, reducing CT doses increases image noise from the filtered back projection (FBP) reconstruction. Strategies to reduce radiation exposure include the use of iterative reconstruction algorithms. A new algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) decreases the image noise up to 70% compared with the gold standard FBP model. Moreover, Veo improves spatial resolution with excellent detection of low and high contrast objects from a CT Dose Index (CTDIvol) equal to 0.3 mGy.

The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality.

Read the detailed description

Asbestos-exposed workers will be recruited following referral to our radiology department for the evaluation of asbestos-related disease. CT examinations will be performed with a 64-slice CT system (Discovery CT 750HD; GE Healthcare, Milwaukee, WI) and will consist of two successive acquisitions. Each examination, the normal-dose (FBP acquisition) and ultra-low-dose (Veo acquisition) spiral CT, will be performed in supine position, on the entire thorax, at full inspiration and without contrast agent injection.

In order to perform the two acquisitions without increasing radiation, standard acquisition will be performed with the same kV with mA equal to patient's body weight minus 10. To conserve image quality, 60 mA will be the inferior limit. The other CT parameters will be rotation time 0.5 s and pitch 1.375. Image data will be reconstructed with FBP algorithm.

The Veo acquisition will be performed with constant CT parameters including: a tube voltage of 100 kV, a tube current of 20 mA, pitch of 0.984 and rotation time 0.4 s. Image data will be reconstructed with the Veo algorithm.

Each CT acquisition will be viewed independently by two experienced radiologists (2 to 7 years of experience). The low-dose images with Veo reconstruction will be interpreted before the standard CT and on separate weeks to minimize recall bias. Then, the more experienced radiologist will evaluate the detection and characterization of pleuroparenchymal abnormalities by a second and simultaneous reading of the Veo and FBP acquisitions. Because FBP images are benchmark practice, when a lesion will be found only on Veo images, it will be regarded as a false positive.

The following asbestos-related pleural and parenchymal abnormalities will be recorded as present or absent. Pleural abnormalities considered will be: pleural plaques, diffuse pleural thickening and pleural effusion.

CT features of asbestosis will include subpleural dots and branching opacities, curvilinear subpleural lines, areas of ground glass opacities, septal lines, reticulations and honeycombing.

Presence of nodules will also be recorded. We will note for each abnormality: localization (side, table position) and nature (non-solid, part-solid, solid or calcified).

Being tested
New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA)
Keywords
computed tomography, radiation, screening, asbestos, workers, cancer
Medical subject headings
Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA)Device

    The objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality.

Study groups in NCT01955018
Study groupRoleWhat they receive
VeoTMExperimentalA new algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) decreases the image noise up to 70% compared with the gold standard FBP model. Moreover, Veo improves spatial resolution with excellent detection of low and high contrast objects from a CT Dose Index (CTDIvol) equal to 0.3 mGy
Receives: Device: New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA)
gold standard FBP modelOtherThe objective of the present study is to compare Veo with the gold standard FBP for detecting pulmonary asbestos-related conditions among workers previously exposed to asbestos. Comparisons included radiation delivered and image quality
Receives: Device: New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Pleural and parenchymal abnormalities

    The kappa coefficient will be used to measure agreement for categorical parameters and Pearson's correlation coefficient and Lin concordance correlation coefficient for quantitative data.

    Measured: at day 1

Secondary outcomes (2)
  1. Radiation dose

    The dose length product (DLP) will be recorded.

    Measured: at day 1

  2. Quality images assessment

    Respiratory artifacts will be graded on a three-point scale (1 = negligible, 2 = moderate, 3 = salient).

    Images noise will be studied in the axial and coronal planes. A similar scale will be used for subjective image quality in the mediastinum and parenchyma windows.

    Objective image noise (Standard Deviation) and average CT numbers (in Hounsfield's units) will be measured with circular regions of interest (ROI) on different anatomical levels, 10 mm in diameter.

    The signal to noise ratio (SNR) will also be calculated using the equation SNR = CT numbers / noise.

    Measured: at day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Oct 2013 (estimated)
  2. Study startSep 2012
  3. Primary completionApr 2013
  4. Study completionMay 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Single group
Masking
Single blind
Who is masked
Participant
Enrolment
90 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01955018
Sponsor's protocol ID
CHU-0166
Other IDs
2012-A00618-35
Status last verified
Aug 2026
First submitted
2 Sep 2013
Last updated
7 Aug 2026
Results posted
No

Publications

  • Tekath M, Dutheil F, Bellini R, Roche A, Pereira B, Naughton G, Chamoux A, Michel JL. Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study. BMJ Open. 2014 May 30;4(5):e004980. doi: 10.1136/bmjopen-2014-004980.

    PubMed 24879827

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing New algorithm called VeoTM (General Electric Healthcare, Milwaukee, MI, USA) in people with Asbestos-exposed Workers, run by University Hospital, Clermont-Ferrand at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 7 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Pleural and parenchymal abnormalities (time frame: at day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01955018, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in