AzTrials
AzTrials

Coronary Artery DiseaseSO VINCT01956448

SORT-OUT VI - Randomized Clinical Comparison of Biomatrix Flex® and Resolute Integrity®

A study testing Drug eluting stent in people with Coronary Artery Disease and Angina Pectoris, run by Aarhus University Hospital Skejby at 3 sites in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To perform a randomized comparison between the BioMatrix Flex™ and the Resolute Integrity® stents in the treatment of unselected patients with ischemic heart disease. Read more about this study

Who is it for?
Any age
Conditions the study is for
Coronary Artery Disease, Angina Pectoris
What is being tested?
Drug eluting stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
2,800 participants
Where
3 sitesDenmark
Study dates
Mar 2011to Jul 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Patients aged 18 years or over with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion with more than 50% diameter stenosis, requiring treatment with a drug-eluting stent.

Who cannot join

  • life expectancy of less than one year
  • an allergy to aspirin, clopidogrel, ticagrelor, prasugrel, sirolimus, or biolimus
  • participation in another randomized trial
  • inability to provide written informed consent

Trial locations and contacts

3 sites in 1 country.

Denmark3 sites
  • Aalborg University Hospital

    Aalborg, 9000

  • Odense University Hospital

    Odense, 5000

  • Aarhus University Hospital

    Skejby, Aarhus N, 8200

Other trials in Denmark

About this study

Official title: Randomized Clinical Comparison of Biomatrix Flex® and Resolute Integrity® Coronary Stents in Non-selected Patients With Ischemic Heart Disease The SORT OUT VI Study*

To perform a randomized comparison between the BioMatrix Flex™ and the Resolute Integrity® stents in the treatment of unselected patients with ischemic heart disease.

Read the detailed description

SORT OUT VI is a randomized, multicenter, all-comer, two-arm, non-inferiority trial comparing the Biolimus-eluting Biomatrix Flex and the Zotarolimus-eluting Medtronic Resolute Integrity in treatment of atherosclerotic coronary artery lesions.

Primary Endpoint:

Target lesion failure within 12 months of stent implantation (combination of cardiac death, myocardial infarction (not index procedure related) not related to other than index lesion or target lesion revascularization).

Secondary Endpoints:

Individual components of the primary end point comprised the secondary end points and stent thrombosis rate according to the Academic Research Consortium definition (see protocol for further specification of secondary endpoints).

Clinically driven event detection will be used to avoid study-induced reinterventions. Data on mortality, hospital admission, coronary angiography, repeat percutaneous coronary intervention, and coronary bypass surgery will be obtained for all randomly allocated patients from the following national Danish administrative and healthcare registries: the Civil Registration System; the Western Denmark Heart Registry; the Danish National Registry of Patients, which maintains records on all hospitalizations in Denmark; and the Danish Registry of Causes of Death

Being tested
Drug eluting stent
Keywords
Percutaneous coronary intervention, DES, Angina pectoris, Stent
Medical subject headings
Coronary Artery Disease, Angina Pectoris

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Drug eluting stentDevice

    Also called BioMatrix Flex - biolimus eluting stent, Resolute - zotarolimus eluting stent

    Device: Percutaneous intervention with implantation of drug eluting coronary stent (Resolute Integrity)

Study groups in NCT01956448
Study groupRoleWhat they receive
Drug eluting stent (BioMatrix Flex)ExperimentalDevice: Percutaneous coronary intervention with implantation of drug eluting stent (BioMatrix Flex)
Receives: Device: Drug eluting stent
Drug eluting stent (Resolute Integrity)ExperimentalDevice: Percutaneous intervention with implantation of drug eluting coronary stent (Resolute Integrity)
Receives: Device: Drug eluting stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device-related combined endpoint

    Device-related combined endpoint hierarchically:

    cardiac death, non-index procedure related acute myocardial infarction not clearly related to another lesion than the target lesion (new revascularization by PCI or CABG) within 12 months.

    Measured: 1,2,3 and 5 years

Secondary outcomes (12)
  1. Device success rate

    Measured: 12 months

  2. Procedure success rate

    Measured: 12 months

  3. Procedure time

    Measured: 12 months

  4. Fluoroscopy time

    Measured: 12 months

  5. Amount of contrast

    Measured: 12 months

  6. Combined endpoint of cardiac death, non-index procedure related acute myocardial infarction, not clearly related to another lesion than target lesion, target lesion revascularisation

    Measured: 30 days

  7. Target lesion revascularisation

    Measured: 1,2,3 and 5 years

  8. Death and myocardial infarction

    Measured: 1 and 12 months

  9. Stent thrombosis

    Measured: 1,2,3 and 5 years

  10. Device-related combined endpoint hierarchically cardiac death, non-index procedure related AMI, not clearly related to another lesion than target lesion

    Measured: 2,3 and 5 years

  11. Patient-related combined endpoint hierarchically: all-cause death, non-index procedure related acute myocardial infarction, all new revascularizations

    Measured: 1,2,3 and 5 years

  12. All-cause death

    Measured: 10 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Oct 2013 (estimated)
  2. Study startMar 2011
  3. Primary completionJul 2012
  4. Study completionJul 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
2,800 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01956448
Sponsor's protocol ID
M-20110037
Acronym
SO VI
Status last verified
Oct 2013
First submitted
4 Jun 2012
Last updated
8 Oct 2013
Results posted
No
Data monitoring committee
Yes

Publications

  • Raungaard B, Christiansen EH, Botker HE, Hansen HS, Ravkilde J, Thuesen L, Aaroe J, Villadsen AB, Terkelsen CJ, Krusell LR, Maeng M, Kristensen SD, Veien KT, Hansen KN, Junker A, Madsen M, Andersen SL, Jensen SE, Jensen LO; SORT OUT VI Investigators. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial. JACC Cardiovasc Interv. 2017 Feb 13;10(3):255-264. doi: 10.1016/j.jcin.2016.11.007. Epub 2017 Jan 18.

    PubMed 28109874
  • Raungaard B, Jensen LO, Tilsted HH, Christiansen EH, Maeng M, Terkelsen CJ, Krusell LR, Kaltoft A, Kristensen SD, Botker HE, Thuesen L, Aaroe J, Jensen SE, Villadsen AB, Thayssen P, Veien KT, Hansen KN, Junker A, Madsen M, Ravkilde J, Lassen JF; Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT). Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI): a randomised non-inferiority trial. Lancet. 2015 Apr 18;385(9977):1527-35. doi: 10.1016/S0140-6736(14)61794-3. Epub 2015 Jan 16.

    PubMed 25601789

Questions about this trial

What is this clinical trial studying?

A study testing Drug eluting stent in people with Coronary Artery Disease and Angina Pectoris, run by Aarhus University Hospital Skejby at 3 sites in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Oct 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Device-related combined endpoint (time frame: 1,2,3 and 5 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01956448, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Oct 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in