AzTrials
AzTrials

MyopiaNCT01966770

Clinical Evaluation of Hydrogels vs Silicone Hydrogel Contact Lenses

A study testing Pair 1 (ocufilcon D / ocufilcon D), Pair 2 (ocufilcon D / enfilcon A) and Pair 3 (ocufilcon D / comfilcon A) in people with Myopia, run by CooperVision, Inc. at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim of this fitting study is to evaluate the clinical performance of different hydrogel and silicone hydrogel contact lenses. Read more about this study

Who is it for?
Ages 18 to 40 years
Conditions the study is for
Myopia
What is being tested?
Pair 1 (ocufilcon D / ocufilcon D), Pair 2 (ocufilcon D / enfilcon A) and Pair 3 (ocufilcon D / comfilcon A)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteUnited States
Study dates
Oct 2013to Nov 2013
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 40 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • A person is eligible for inclusion in the study if he/she:
  • Is between 18 and 40 years of age (inclusive)
  • Has had a self-reported visual exam in the last two years
  • Is an adapted soft contact lens wearer
  • Has a cl spherical prescription between -1.00 and -6.00 (inclusive)
  • Has a spectacle cylinder up to 0.75D (diopter) in each eye
Show all 11Show fewer
  • Is correctable to a visual acuity of 20/25 or better in both eyes
  • Has clear corneas and no active ocular disease
  • Has read, understood and signed the information consent letter
  • Is willing to comply with the wear schedule
  • Is willing to comply with the visit schedule

Who cannot join

  • A person will be excluded from the study if he/she:
  • Has never worn contact lenses before
  • Currently wears rigid gas permeable contact lenses
  • Has a history of not achieving comfortable contact lens wear (5 days per week; > 8 hours/day)
  • Has a contact lens prescription outside the range of -1.00 to -6.00D
  • Has a spectacle cylinder ≥ 1.00D of cylinder in either eye
Show all 15Show fewer
  • Has best corrected spectacle distance vision worse than 20/25 in either eye
  • Has any systemic or topical medications that will affect ocular health
  • Has any ocular pathology or severe insufficiency of lacrimal secretion
  • Has persistent, clinically significant corneal or conjunctival staining
  • Has active neovascularization or any central corneal scars
  • Is aphakic
  • Is presbyopic
  • Has undergone corneal refractive surgery
  • Is participating in any other type of eye related conical or research study

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of California, Berkeley Clinical Research Center (UCB-CRC)

    Berkeley, California, 94720-2020

Other trials in United States

About this study

The aim of this fitting study is to evaluate the clinical performance of different hydrogel and silicone hydrogel contact lenses.

Read the detailed description

This is a 20-subject, double masked, randomized, contra lateral, 2-day non-dispensing fitting trial.

Conditions
Myopia
Being tested
Pair 1 (ocufilcon D / ocufilcon D), Pair 2 (ocufilcon D / enfilcon A), Pair 3 (ocufilcon D / comfilcon A), Pair 4 (methafilcon A / methafilcon A), Pair 5 (methafilcon A / comfilcon A)
Medical subject headings
Myopia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pair 1 (ocufilcon D / ocufilcon D)Device

    Randomized to contra lateral lens pair 1 (ocufilcon D hydrogel / ocufilcon D hydrogel)

  • Pair 2 (ocufilcon D / enfilcon A)Device

    Randomized to contra lateral lens pair 2 (ocufilcon D hydrogel / enfilcon A silicone)

  • Pair 3 (ocufilcon D / comfilcon A)Device

    Randomized to contra lateral lens pair 3 (ocufilcon D hydrogel / comfilcon A silicone)

  • Pair 4 (methafilcon A / methafilcon A)Device

    Randomized to contra lateral lens pair 4 (methafilcon A hydrogel sphere / methafilcon A hydrogel asphere)

  • Pair 5 (methafilcon A / comfilcon A)Device

    Randomized to contra lateral lens pair 5 (methafilcon A hydrogel / comfilcon A silicone)

  • Pair 6 (omafilcon A / comfilcon A)Device

    Randomized to contra lateral lens pair 6 (omafilcon A hydrogel / comfilcon A silicone)

Study groups in NCT01966770
Study groupRoleWhat they receive
Pair 1 (ocufilcon D / ocufilcon D)Active comparatorRandomized to contra lateral lens pair 1 (ocufilcon D hydrogel / ocufilcon D hydrogel)
Receives: Device: Pair 1 (ocufilcon D / ocufilcon D)
Pair 2 (ocufilcon D / enfilcon A)Active comparatorRandomized to contra lateral lens pair 2 (ocufilcon D hydrogel / enfilcon A silicone)
Receives: Device: Pair 2 (ocufilcon D / enfilcon A)
Pair 3 (ocufilcon D / comfilcon A)Active comparatorRandomized to contra lateral lens pair 3 (ocufilcon D hydrogel / comfilcon A silicone)
Receives: Device: Pair 3 (ocufilcon D / comfilcon A)
Pair 4 (methafilcon A / methafilcon A)Active comparatorRandomized to contra lateral lens pair 4 (methafilcon A hydrogel sphere / methafilcon A hydrogel asphere)
Receives: Device: Pair 4 (methafilcon A / methafilcon A)
Pair 5 (methafilcon A / comfilcon A)Active comparatorRandomized to contra lateral lens pair 5 (methafilcon A hydrogel / comfilcon A silicone)
Receives: Device: Pair 5 (methafilcon A / comfilcon A)
Pair 6 (omafilcon A / comfilcon A)Active comparatorRandomized to contra lateral lens pair 6 (omafilcon A hydrogel / comfilcon A silicone)
Receives: Device: Pair 6 (omafilcon A / comfilcon A)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Visual Acuity (VA) logMAR (Habitual Lenses)

    Assessment of high contrast distance visual acuity (VA). Collected at baseline with subject wearing habitual lens prior to dispense of study lens. (logMAR)

    Measured: Baseline

  2. Visual Acuity (VA) logMAR (Study Lenses)

    Assessment of high contrast distance visual acuity (VA). Collected at dispense of study lens. (logMAR)

    Measured: Dispense

  3. Comfort Contact Lens Insertion (Day 1 Study Lenses)

    Participant rating of comfort upon contact lens insertion. Collected after insertion at Day 1 for each lens . (0-100, 0=cannot be worn causes pain, 100=cannot be felt ever)

    Measured: Day 1 - Insertion

  4. Comfort Contact Lens 30 Minutes Wear (Day 1 Study Lenses)

    Participant rating of comfort after contact lens settling. Collected at 30 minutes wear for each lens. (0-100, 0=cannot be worn causes pain, 100=cannot be felt ever)

    Measured: Day 1 - 30 minutes

  5. Comfort Contact Lens Insertion (Day 2 Study Lenses)

    Participant rating of comfort upon contact lens insertion. Collected after insertion at Day 2 for each lens . (0-100, 0=cannot be worn causes pain, 100=cannot be felt ever

    Measured: Day 2 - Insertion

  6. Comfort Contact Lens 30 Minutes Wear (Day 2 Study Lenses)

    Participant rating of comfort upon contact lens insertion. Collected after 30 minutes of wear at Day 2 for each lens . (0-100, 0=cannot be be worn causes pain, 100=cannot be felt ever

    Measured: Day 2 - 30 minutes

  7. Comfort Preference Contact Lens Insertion (Day 1 Study Lenses - Pair 1)

    Participant rating of comfort preference upon contact lens insertion of pair 1. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 - Insertion

  8. Comfort Preference Contact Lens Insertion (Day 1 Study Lenses - Pair 2)

    Participant rating of comfort preference upon contact lens insertion of pair 2. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 Insertion

  9. Comfort Preference Contact Lens Insertion (Day 1 Study Lenses - Pair 3)

    Participant rating of comfort preference upon contact lens insertion of pair 3. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 - Insertion

  10. Comfort Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 1)

    Participant rating of comfort preference upon contact lens settling of pair 1. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 - 30 minutes

  11. Comfort Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 2)

    Participant rating of comfort preference upon contact lens settling of pair 2. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 - 30 minutes

  12. Comfort Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 3)

    Participant rating of comfort preference upon contact lens settling of pair 3. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 1 - 30 minutes

  13. Comfort Preference Contact Lens Insertion (Day 2 Study Lenses - Pair 1)

    Participant rating of comfort preference upon contact lens insertion of pair 1. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 2 - Insertion

  14. Comfort Preference Contact Lens Insertion (Day 2 Study Lenses - Pair 2)

    Participant rating of comfort preference upon contact lens insertion of pair 2. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 2 - Insertion

  15. Comfort Preference Contact Lens Insertion (Day 2 Study Lenses - Pair 3)

    Participant rating of comfort preference upon contact lens insertion of pair 3. Collected at insertion for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 2 - Insertion

  16. Comfort Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 1)

    Participant rating of comfort preference upon contact lens settling of pair 1. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly Prefer Left, No Preference, Slightly Prefer Right, Strongly Prefer Right)

    Measured: Day 2 - 30 minutes

  17. Comfort Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 2)

    Participant rating of comfort preference upon contact lens settling of pair 2. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly prefer Left, No Preference, Slightly prefer Right, Strongly prefer Right)

    Measured: Day 2 - 30 minutes

  18. Comfort Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 3)

    Participant rating of comfort preference upon contact lens settling of pair 3. Collected at 30 minutes post settling for each lens. Percent of participants that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strongly Prefer Left, Slightly prefer Left, No Preference, Slightly prefer Right, Strongly prefer Right)

    Measured: Day 2 - 30 minutes

  19. Lens Fitting Characteristics, Centration (Habitual Lens)

    Assessment of habitual lens fitting characteristics for the percentage of lenses with optimal centration. Collected at baseline with subject wearing habitual lens prior to dispense of study lens. (Optimal Centration for Right and Left eyes; Optimum, Decentration Acceptable, Decentration unacceptable)

    Measured: Baseline

  20. Lens Fitting Characteristics, Tightness (Habitual Lens)

    Assessment of habitual lens fitting characteristics. Collected at baseline with subject wearing habitual lens prior to dispense of study lens. Digital push up test. (Continuous scale 0-100%, 0%=falls from cornea without lid support, 50%=optimum, 100%=no movement)

    Measured: Baseline

  21. Lens Fitting Characteristics, Upgaze Lag and Post-blink Movement (Habitual Lens)

    Assessment of habitual lens fitting characteristics. Collected at baseline with subject wearing habitual lens prior to dispense of study lens.(Upgaze Lag and Post-blink Movement in mm)

    Measured: Baseline

  22. Lens Fitting Characteristics, Centration (Day 1 Study Lenses)

    Assessment of lens fitting characteristics for the percentage of lenses with optimal centration. Collected at 30 minutes after lens settling of study lens. (Optimal Centration for Right and Left eyes; Optimum, Decentration Acceptable, Decentration unacceptable)

    Measured: Day 1 - 30 minutes

  23. Lens Fitting Characteristics, Push-up Tightness (Day 1 Study Lenses)

    Assessment of lens fitting characteristics. Collected at 30 minutes after lens settling of study lens. Digital push up test. (Continuous scale 0-100%, 0%=falls from cornea without lid support, 50%=optimum, 100%=no movement)

    Measured: Day 1 - 30 minutes

  24. Lens Fitting Characteristics, Upper Gaze Lag and Post-blink Movement (Day 1 - Study Lenses)

    Assessment of lens fitting characteristics. Collected at 30 minutes after lens settling of study lens. (Upgaze Lag and Post-blink Movement in mm)

    Measured: Day 1 - 30 minutes

  25. Lens Fitting Characteristics, Centration (Day 2 Study Lenses)

    Assessment of lens fitting characteristics for the percentage of lenses with optimal centration. Collected at 30 minutes after lens settling of study lens. (Optimal Centration for Right and Left eyes; Optimum, Decentration Acceptable, Decentration unacceptable)

    Measured: Day 2 - 30 minutes

  26. Lens Fitting Characteristics, Push-up Tightness (Day 2 Study Lenses)

    Assessment of lens fitting characteristics. Collected at 30 minutes after lens settling of study lens. Digital push up test. (Continuous scale 0-100%, 0%=falls from cornea without lid support, 50%=optimum, 100%=no movement)

    Measured: Day 2 - 30 minutes

  27. Lens Fitting Characteristics, Upper Gaze Lag and Post-blink Movement (Day 2 Study Lenses)

    Assessment of lens fitting characteristics. Collected at 30 minutes after lens settling of study lens.(Upgaze Lag and Post-blink Movement in mm)

    Measured: Day 2 - 30 minutes

  28. Investigator Fit Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 1)

    Investigator rating of fit preference upon contact lens settling of pair 1. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 1- 30 minutes

  29. Investigator Fit Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 2)

    Investigator rating of fit preference upon contact lens settling of pair 2. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 1- 30 minutes

  30. Investigator Fit Preference Contact Lens 30 Minutes Wear (Day 1 Study Lenses - Pair 3)

    Investigator rating of fit preference upon contact lens settling of pair 3. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 1 - 30 minutes

  31. Investigator Fit Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 1)

    Investigator rating of fit preference upon contact lens settling of pair 1. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 2 - Insertion

  32. Investigator Fit Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 2)

    Investigator rating of fit preference upon contact lens settling of pair 2. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 2 - Insertion

  33. Investigator Preference Contact Lens 30 Minutes Wear (Day 2 Study Lenses - Pair 3)

    Investigator rating of fit preference upon contact lens settling of pair 3. Collected at 30 minutes post settling for each lens. Percent of investigators that strongly prefer lens or have No Preference. (forced choice preference for right or left eye; Strong R, Slight R, No Pref, Slight L, Strong L)

    Measured: Day 2 - Insertion

  34. Overall Ease of Lens Handling (Day 1 Study Lenses)

    Participant rating of overall lens handling regarding insertion and removal. Collected at post-removal for each lens on Day 1. (0-100, 0=very difficult, 100=very easy

    Measured: Day 1 - After Removal

  35. Overall Ease of Lens Handling (Day 2 Study Lenses)

    Participant rating of overall lens handling regarding insertion and removal. Collected at post-removal for each lens on Day 2. (0-100, 0=very difficult, 100=very easy

    Measured: Day 2 - After Removal

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Oct 2013 (estimated)
  2. Study startOct 2013
  3. Primary completionNov 2013
  4. Study completionNov 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Single group
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01966770
Sponsor's protocol ID
EX-MKTG-44
Status last verified
Jul 2020
First submitted
15 Oct 2013
Last updated
30 Jul 2020
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Pair 1 (ocufilcon D / ocufilcon D), Pair 2 (ocufilcon D / enfilcon A) and Pair 3 (ocufilcon D / comfilcon A) in people with Myopia, run by CooperVision, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 11 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 27 Feb 2015). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Visual Acuity (VA) logMAR (Habitual Lenses) (time frame: Baseline). The study lists 35 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jul 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in