AzTrials
AzTrials

Laboring Women With Ultrasound and FSE MonitoringFHRNCT02024165

Electrode-Based Sensor for Non-Invasive Fetal Heart Rate Monitoring With Improved Reliability

An observational study of Laboring Women With Ultrasound and FSE Monitoring, run by OBMedical Company at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The specific goal of the proposed research is to develop a reliable, non-invasive fetal and maternal heart rate and contraction monitor that is unaffected by obesity and requires less nursing intervention than the tocodynamometer and Doppler ultrasound. Read more about this study

Who is it for?
Ages 18 to 50 years, women only
How many people
71 participants
Where
1 siteUnited States
Study dates
Nov 2013to Apr 2014
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • Women only
  • No healthy volunteers
  • Adult

Study population: Laboring women in Labor and Delivery Ward

Who may be able to join

  • Parturients presenting to Labor \& Delivery for labor at term (>36 weeks completed gestation)
  • Single viable fetus in cephalic presentation
  • With FSE or IUPC for obstetric indications

Who cannot join

  • Multi fetal gestation
  • Contraindication to FSE or IUPC placement
  • Insufficient abdominal space for all required sensors

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Winnie Palmer Hospital for Women and Babies

    Orlando, Florida, 32806

Other trials in United States

About this study

The specific goal of the proposed research is to develop a reliable, non-invasive fetal and maternal heart rate and contraction monitor that is unaffected by obesity and requires less nursing intervention than the tocodynamometer and Doppler ultrasound.

Read the detailed description

The majority of obstetric deliveries in the US undergo electronic monitoring and continuous uterine activity and fetal heart rate (FHR) monitoring is the standard of care. Typically, external transducers are employed, the reliability of which depends on their proper positioning, which may be disturbed by patient or fetal movement. The tocodynamometer (strain gauge, toco for short) provides frequency and timing of contractions, but requires transmission of tension from the uterus to the sensor. Fetal heart rate is acquired with an external Doppler ultrasound transducer. The reliability of this monitor depends on the ability to obtain a window to the fetal heart.

In some patients, particularly the obese, the toco and ultrasound may fail to monitor consistently. In others both transducers require frequent repositioning by the nursing staff, and the Doppler may erroneously report maternal heart rate instead of fetal.

The alternative uterine activity monitor is an intrauterine pressure catheter (IUPC), which is placed through the cervical os in the adequately dilated patient with ruptured membranes. While this monitor usually provides a more reliable signal than the toco, as well as quantitative information regarding intrauterine pressure, it is invasive and there is an increased risk of infection. The alternative FHR monitor is via fetal scalp electrode (FSE), which is applied transvaginally to the fetal presenting part, also requiring adequate cervical dilation and ruptured membranes. While the FSE usually provides a more reliable signal, it is similarly invasive and increases risk of infection.

Maternal obesity (defined as BMI at presentation ≥ 30) is an ever-increasing problem in the US, and is even more prominent in the obstetric suite. Meanwhile, obese women have an increased risk for labor problems, infections and other complications. Noninvasive labor monitoring, while preferable to reduce the infection risk, is particularly unreliable in this population.

Keywords
Ultrasound, FSE, IUPC

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT02024165
Study groupRoleWhat they receive
Electrode Sensor, FSEPregnant women between the ages of 18-50 with a single viable fetus in cephalic presentation monitored with Electrode Sensor, and/or FSE
Electrode Sensor, UltrasoundPregnant women between the ages of 18-50 with a single viable fetus in cephalic presentation monitored with Electrode Sensor, and/or Ultrasound

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Fetal Heart Rate Interpretability

    The Fetal Heart Rate (or FHR) of the electrode sensor will be compared to the FHR of the ultrasound when both are compared to the FSE. Percentage of time that signals are interpretable will be compared between devices

    Measured: 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted31 Dec 2013 (estimated)
  2. Study startNov 2013
  3. Primary completionApr 2014
  4. Study completionApr 2014

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
71 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02024165
Sponsor's protocol ID
OBM-WP-2013
Other IDs
IRB
Acronym
FHR
Status last verified
Apr 2015
First submitted
2 Dec 2013
Last updated
12 May 2015
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Laboring Women With Ultrasound and FSE Monitoring, run by OBMedical Company at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 May 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 12 May 2015). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Fetal Heart Rate Interpretability (time frame: 2 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 May 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in