A study testing Xtra®, Sorin cellsaver, C.A.T.S.®, Fresenius cellsaver and CardioPAT®, Haemonetics, cellsaver in people with Coronary Artery Bypass, Off-Pump, run by University Medical Center Groningen at 1 site in Netherlands.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Cell savers are routinely used in our hospital during off-pump coronary artery bypass grafting to retrieve and wash blood that is lost during the operation. This washed blood is retransfused to the patient in order to prevent allogeneic blood transfusion. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Bypass, Off-Pump
What is being tested?
Xtra®, Sorin cellsaver, C.A.T.S.®, Fresenius cellsaver and CardioPAT®, Haemonetics, cellsaver
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
1 siteNetherlands
Study dates
Jan 2014to Dec 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Scheduled for OPCABG surgery
  • Age > 18 years
  • Informed consent

Who cannot join

  • A potential subject who meets any of the following criteria will be excluded from participation in this study:
  • Patients with known hematologic or microvascular disorders. Patients will be excluded intraoperatively when conversion to on-pump coronary artery bypass grafting is necessary or when allogeneic red blood cell transfusion is required.

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • University Medical Center Groningen

    Groningen, Provincie Groningen, 9713EZ

Other trials in Netherlands

About this study

Official title: The Rheologic Properties and Oxygen Transport Capacity of Red Blood Cells Processed by 3 Different Types of Cell Saving, and Its Effects on Microcirculatory Blood Flow and Tissue Oxygenation in Vivo

Cell savers are routinely used in our hospital during off-pump coronary artery bypass grafting to retrieve and wash blood that is lost during the operation. This washed blood is retransfused to the patient in order to prevent allogeneic blood transfusion. However, little is known about the rheologic properties and oxygen transport capacity of the washed red blood cells and the effects of retransfusion of this blood on microcirculatory blood flow and organ damage in the patient. For cell savers 3 different operating principles exist. The most common one uses discontinuous blood washing with a spinning bowl that is intermittently filled with blood, processed and emptied. A second one uses a continuous blood washing principle with a rotational disk. A third one is intermediate using features of both the discontinuous bowl technology and the continuous rotational disc technology.

The investigator hypothesize that the operating principle has effects on the rheologic properties and oxygen transport capacity of the washed blood.

Previous research suggested that in particular the deformability and oxygen carrier properties of the red blood cells are affected. As a consequence, red blood cells may block small blood vessels, which affects microcirculatory blood flow and tissue oxygenation. This may lead to organ damage.

Read the detailed description

Cell savers are routinely used in our hospital during off-pump coronary artery bypass grafting (OPCABG) to retrieve and wash blood that is lost during the operation. This washed blood is retransfused to the patient in order to prevent allogeneic blood transfusion.

For cell savers 3 different operating principles exist. The most common type uses discontinuous blood processing with a spinning bowl that is intermittently filled with blood, processed and emptied. A second type uses a continuous blood processing principle with a rotational disk. A third one is intermediate using features of both the discontinuous bowl technology and the continuous rotational disc technology. In all types of autotransfusion systems the wound blood is washed, concentrated and stored in a blood conservation bag.

In several studies hemoglobin levels, leucocyte and platelet counts in the washed cell saver blood have been measured, indicating differences between types of cell saving. In other studies biochemical markers of inflammation in the washed cell saver blood have been measured, also indicating differences between types of cell saving. Recently, blood bank blood at the end of its shelf life was washed using similar devices as proposed in this study. The investigated devices removed substances from the blood differently. However, the rheologic properties of the red blood cells were not assessed.

Despite widespread clinical use of cell savers, little is therefore known about the rheologic properties and oxygen transport capacity of the washed red blood cells. As the process of washing of the blood cells occurs with high centrifugal loads, there is concern about the elasticity and deformability of the processed red blood cells. Ultrastructural changes in cell saver washed red blood cells have been demonstrated using scanning electron microscopy suggesting poor performance of these cells in the microcirculation. Using the continuous type of cell saver, we previously could demonstrate a reduction in deformability and 2,3-Diphosphoglycerate (DPG) levels of the processed blood cells. The implication is that microcirculatory blood flow may be obstructed by blockage of the small blood vessels and, as 2,3-DPG regulates oxygen transfer, tissue oxygenation may also be hampered. However, at the moment the effects of retransfusion of the washed cell saver blood on microcirculatory blood flow and tissue oxygenation in patients are unknown.

Thus, in this study the investigator want to determine in vitro the rheologic properties and oxygen transport capacity of the washed blood processed by one of 3 different types of cell saving (discontinuous, continuous and mixed) and to measure in vivo after retransfusion of this processed blood in the patient the effects on microcirculatory blood flow, tissue oxygenation and organ damage using organ specific biomarkers.

Being tested
Xtra®, Sorin cellsaver, C.A.T.S.®, Fresenius cellsaver, CardioPAT®, Haemonetics, cellsaver, no use of cell saver

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Xtra®, Sorin cellsaverDevice

    when at least 750 mL of wound blood is collected in the reservoir during the operation, the washing process will be started using one of the three cell savers (see above). Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.

  • C.A.T.S.®, Fresenius cellsaverDevice

    when at least 750 mL of wound blood is collected in the reservoir during the operation, the washing process will be started using one of the three cell savers (see above). Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.

  • CardioPAT®, Haemonetics, cellsaverDevice

    when at least 750 mL of wound blood is collected in the reservoir during the operation, the washing process will be started using one of the three cell savers (see above). Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.

  • no use of cell saverOther

    When less than 750 ml of wound blood is collected in the reservoir at the end of the operation, patients will be automatically allocated to the control group. The collected blood will be cast away according to daily clinical practice and recommendations of the manufacturers.

Study groups in NCT02046824
Study groupRoleWhat they receive
Xtra®, Sorin cellsaverExperimentalwhen at least 750 mL of wound blood is collected in the reservoir during the operation, and when the patients has been allocated to the Xtra Sorin cellsaver group, the washing process will be started. Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.
Receives: Device: Xtra®, Sorin cellsaver
C.A.T.S.®, Fresenius cellsaverExperimentalwhen at least 750 mL of wound blood is collected in the reservoir during the operation, and when the patients has been allocated to the C.A.T.S. cellsaver group, the washing process will be started. Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.
Receives: Device: C.A.T.S.®, Fresenius cellsaver
CardioPAT®, Haemonetics, cellsaverExperimentalwhen at least 750 mL of wound blood is collected in the reservoir during the operation, and when the patients has been allocated to the CardioPAT cellsaver group, the washing process will be started. Samples will be taken from before and after the washing process. Thereafter, the blood will be retransfused to the patient.
Receives: Device: CardioPAT®, Haemonetics, cellsaver
no use of cell saverOtherWhen less than 750 ml of wound blood is collected in the reservoir at the end of the operation, patients will be automatically allocated to the control group. The collected blood will be cast away according to daily clinical practice and recommendations of the manufacturers.
Receives: Other: no use of cell saver

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. quality of the washed red blood cells, measured by their deformability and oxygen carrying capacity

    Changes in elongation index, aggregation index, and 2,3-DPG and ATP levels of the washed red blood cells processed by one of 3 different cell savers.

    Measured: during operation

Secondary outcomes (3)
  1. microcirculatory blood flow

    The effects of of retransfusion of washed cell saver blood of either device in the patient measured by microcirculatory blood flow.

    Measured: during operation

  2. Tissue oxygenation

    Effects of retransfusion of washed cell saver blood of either device in the patient measured by tissue oxygenation

    Measured: during operation

  3. Organ damage

    The effects of of retransfusion of washed cell saver blood of either device in the patient measured by biochemical markers of organ damage.

    Measured: during hospital stay after surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Jan 2014 (estimated)
  2. Study startJan 2014
  3. Primary completionDec 2015
  4. Study completionDec 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Participant, Care provider
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02046824
Sponsor's protocol ID
Cell Saver-001
Status last verified
Dec 2016
First submitted
20 Jan 2014
Last updated
16 Dec 2016
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Xtra®, Sorin cellsaver, C.A.T.S.®, Fresenius cellsaver and CardioPAT®, Haemonetics, cellsaver in people with Coronary Artery Bypass, Off-Pump, run by University Medical Center Groningen at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 16 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early. Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

quality of the washed red blood cells, measured by their deformability and oxygen carrying capacity (time frame: during operation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Dec 2016.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in