Trial summary

Hemodynamic management of critically ill patients is a constant challenge in the intensive care unit (ICU). Commonly used monitoring parameters to guide hemodynamic management generally consist of measurements of pressures (systemic and pulmonary artery pressures, cardiac filling pressures) and flow (cardiac output… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Shock
What is being tested?
ImaCor PM and ImaCor SM
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
550 participants
Where
1 siteSwitzerland
Study dates
Mar 2014to 1 May 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 18 years of age or older AND
  • Mechanical ventilation AND
  • Systemic mean blood pressure < 60 mmHg (or < 80 mmHg if the patient has baseline hypertension) for more than 30 minutes despite adequate fluid resuscitation (minimum of 20 ml/kg crystalloids) OR
  • Maintaining the systemic mean blood pressure > 60 mmHg requires any dose of vasopressors or inotropes AND at least one of the following:
  • Capillary refilling time three seconds or longer
  • Lactate >2 mmol/L
  • Urine output <0.5 mL/kg for at least one hour
  • Written informed consent

Who cannot join

  • Unrepaired tracheoesophageal fistula
  • History of prior esophageal or gastric surgery precluding the use of TEE
  • Esophageal obstruction or stricture
  • Esophageal varices or diverticulum
  • Esophageal or gastric perforation
  • Gastric or esophageal bleeding
Show all 13Show fewer
  • Vascular ring, aortic arch anomaly with or without airway compromise
  • Recent oropharyngeal surgery
  • Severe coagulopathy (defined as thrombocyte count less than 30x10e9/l or INR > 3)
  • Cervical spine injury or anomaly
  • Elective ICU admission after elective surgery
  • Use of cardiac assist devices
  • Use of extra-corporeal membrane oxygenation

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Dep. of Intensive Care Medicine, Bern University Hospital

    Bern, 3010

Other trials in Switzerland

About this study

Official title: ImaCor II Effects of Hemodynamic Monitoring Using the ImaCor Single Use Transesophageal Echocardiography Probe in Critically Ill Patients - a Randomized Controlled Trial

Hemodynamic management of critically ill patients is a constant challenge in the intensive care unit (ICU). Commonly used monitoring parameters to guide hemodynamic management generally consist of measurements of pressures (systemic and pulmonary artery pressures, cardiac filling pressures) and flow (cardiac output measurements using a thermodilution method). However, cardiac filling pressures and flow data have known limitations and might not accurately represent cardiac preload and contractility. Hemodynamic management of critically ill patients based on these parameters might therefore not be optimal and delay stabilisation of the patient, leading to negative outcomes and increased use of resources.

Visualization of the heart using echocardiography offers the advantage of direct measurement of cardiac volumes and systolic function. Echocardiography has been established as a tool to evaluate the causes of hemodynamic instability in ICU patients by the visualization of cardiac chambers, valves and pericardium and cardiac functional abnormalities. A repeated echocardiographic assessment could potentially provide useful additional information resulting in more rapid resolution of hemodynamic instability. Using conventional TTE and TEE, however, limits the feasibility of such an approach due to a lack of time and availability of appropriately trained staff.

In recently published studies the feasibility of hemodynamic monitoring and safety of hTEE was demonstrated. In the context of a prospective quality review assessment, the investigators showed that the echocardiographic examinations using hTEE were of sufficient quality in a majority of examined ICU patients and that the inter-rater reliability between the intensivists and a trained cardiologist was substantial. However, as of yet studies assessing the impact of hemodynamic monitoring by hTEE on relevant patient outcomes are not available. Given the associated costs for the hTEE device and the ultrasound probes and the additional resource requirements for training and application, the efficacy and efficiency of hTEE monitoring in comparison to standard monitoring should be established.

Read the detailed description

Background

Hemodynamic management of critically ill patients is a constant challenge in the intensive care unit (ICU). Commonly used monitoring parameters to guide hemodynamic management generally consist of measurements of pressures (systemic and pulmonary artery pressures, cardiac filling pressures) and flow (cardiac output measurements using a thermodilution method). However, cardiac filling pressures and flow data have known limitations and might not accurately represent cardiac preload and contractility. To date, continuous or sequential recording of hemodynamic parameters is limited to pulse pressure variation measurement and indicator dilution techniques. The overall accuracy of these methods is not well established and comparisons of measurements of cardiac function parameters have been reported to trend differently in response to therapy and show limited interdevice agreement. Hemodynamic management of critically ill patients based on these parameters might therefore not be optimal and delay stabilisation of the patient, leading to negative outcomes and increased use of resources.

Visualization of the heart using echocardiography offers the advantage of direct measurement of cardiac volumes and systolic function. Echocardiography has been established as a tool to evaluate the causes of hemodynamic instability in ICU patients by the visualization of cardiac chambers, valves and pericardium and cardiac functional abnormalities. Transthoracic echocardiography (TTE) can be used as a first-line approach for a quick and focused examination to diagnose acute cor pulmonale, cardiac tamponade or major left ventricular systolic dysfunction. The training necessary to reliably perform such an abbreviated TTE use is substantial and the method is not readily available for every intensivist. Transesophageal echocardiography (TEE) can have a better diagnostic capability and is more reproducible than TTE. A minimum number of 31 TEE examinations has been reported to be required for intensivists to achieve competence in TEE driven hemodynamic evaluation of ventilated ICU patients. Additionally, repeatedly inserting the TEE probe as required for serial evaluation of a patients hemodynamic status is associated with a small but significant risk of injury to oral and esophageal structures. A repeated echocardiographic assessment could potentially provide useful additional information resulting in more rapid resolution of hemodynamic instability. Using conventional TTE and TEE, however, limits the feasibility of such an approach due to a lack of time and availability of appropriately trained staff.

In a recently published study the feasibility of hemodynamic monitoring and safety of hTEE was demonstrated in a group of ninety-four ventilated critically ill patients. In this study hTEE examinations were performed by four highly trained intensivist with extensive expertise in critically care echocardiography. The Department of Intensive Care Medicine Inselspital (KIM) has introduced hTEE in January 2012. The feasibility and quality of hemodynamic monitoring using hTEE by the department's intensivists was assessed in the context of a prospective quality review assessment. The study showed that the echocardiographic examinations using hTEE were of sufficient quality in a majority of examined ICU patients and that the inter-rater reliability between the intensivists and a trained cardiologist was substantial. However, as of yet studies assessing the impact of hemodynamic monitoring by hTEE on relevant patient outcomes are not available. Given the associated costs for the hTEE device and the ultrasound probes and the additional resource requirements for training and application, the efficacy and efficiency of hTEE monitoring in comparison to standard monitoring should be established.

The investigated device consists of a newly developed, commercially available transesophageal echocardiography system. The ImaCor ClariTEE technology (hTEE) device produces a single-plane two-dimensional image and has color Doppler capability (IMACOR, New-York NY, USA). The ImaCor probe is a 5.5 mm detachable probe; due to its small size it can remain in situ for up to 72h and therefore allows for reassessment of the patient's hemodynamic progress and the effect of selected interventions at any time. The probe has to be disposed after 72h for hygienic reasons. The probe is connected to a dedicated echocardiographic system which allows the recording of digital loops and performance of basic two-dimensional measurements of areas and distances. It provides a robust, but more rapid and user-friendly approach to monitoring hemodynamic status and cardiac function than conventional TTE/TEE.

Objective

The study hypothesis is that hemodynamic monitoring using hTEE of critically ill patients with hemodynamic compromise allows for an expedited reversal of circulatory impairment compared to standard ICU monitoring.

Primary Objective: To assess the impact of hemodynamic monitoring using the ImaCor ClariTEE technology on duration and amount of vasopressor use and time to reversal of shock in hemodynamically compromised patients in comparison to standard monitoring.

Secondary Objective: To assess the safety and tolerability of the ImaCor ClariTEE probe.

Methods

Subjects will be assigned to one of four groups stratified by method of hemodynamic monitoring (ImaCor vs control hemodynamic monitoring) and frequency of hemodynamic assessments (protocolized intervals PM vs standard monitoring intervals SM). In patients randomized to echocardiography-guided hemodynamic management (ImaCorPM and ImaCorSM) the ImaCor ClariTEE system will be installed at the time of study inclusion. An ICU consultant will assess the patients' hemodynamic condition based on the hTEE information (ImaCorPM and SM) and other available hemodynamic parameters (ControlPM and SM). Any changes in hemodynamic management are recorded.

Conditions
Shock
Being tested
ImaCor PM, ImaCor SM, Control PM, Control SM
Keywords
Echocardiography, Transesophageal, Monitoring, Physiologic, Shock
Medical subject headings
Shock

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ImaCor PMDevice

    The ImaCor ClariTEE (hTEE) device is a transesophageal echocardiography system. It produces a single-plane two-dimensional image. The ImaCor probe is a 5.5 mm detachable probe; it can remain in situ for up to 72h and allows for reassessment of the patient's hemodynamic progress and the effect of selected interventions at any time. The probe is connected to a dedicated echocardiographic system which allows the for the recording of digital loops and performance of basic two-dimensional measurements. ImaCorPM subjects will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, at the time of occurrence of defined new organ system deterioration and/or at least every 4 hours during the first 72h after study inclusion or until one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

  • ImaCor SMDevice

    The ImaCor ClariTEE (hTEE) device is a transesophageal echocardiography system. It produces a single-plane two-dimensional image. The ImaCor probe is a 5.5 mm detachable probe; it can remain in situ for up to 72h and allows for reassessment of the patient's hemodynamic progress and the effect of selected interventions at any time. The probe is connected to a dedicated echocardiographic system which allows the for the recording of digital loops and performance of basic two-dimensional measurements. ImaCorSM subjects will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, follow-up assessment intervals are at the discretion of the treating physician for the first 72h after study inclusion. hTEE monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

  • Control PMOther

    Group Control protocolized monitoring (ControlPM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, at the time of occurrence of defined new organ system deterioration or at least every 4 hours for the first 72h after study inclusion. Protocolized monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

  • Control SMOther

    Group Control standard monitoring (ControlSM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, follow-up measurement intervals are at the discretion of the treating physician for the first 72h. Data collection from standard monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.

Study groups in NCT02048566
Study groupRoleWhat they receive
hTEEPMExperimentalGroup hTEE protocolled monitoring (hTEEPM) will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, at the time of occurrence of defined new organ system deterioration (see below) and/or at least every 4 hours during the first 72h after study inclusion or until one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.
Receives: Device: ImaCor PM
hTEESMExperimentalGroup hTEE standard monitoring (hTEESM) will receive echocardiography-guided hemodynamic management (hTEE) at the time of inclusion, follow-up assessment intervals are at the discretion of the treating physician for the first 72h after study inclusion. A follow up assessment is defined as any assessment that leads to significant changes in hemodynamic management in which case an hTEE assessment has to be performed. hTEE monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.
Receives: Device: ImaCor SM
ControlPMActive comparatorGroup Control protocolized monitoring (ControlPM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, at the time of occurrence of defined new organ system deterioration or at least every 4 hours for the first 72h after study inclusion. Protocolized monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.
Receives: Other: Control PM
ControlSMActive comparatorGroup Control standard monitoring (ControlSM) will receive any hemodynamic monitoring of choice of the treating physician except ImaCor. Protocolized hemodynamic assessments will be performed at the time of inclusion, follow-up measurement intervals are at the discretion of the treating physician for the first 72h after study inclusion. A follow up assessment is defined as any assessment that leads to significant changes in hemodynamic management. Data collection from standard monitoring is discontinued if one of the following events occurs: study primary endpoints reached, patient is extubated, withdrawal of active treatment.
Receives: Other: Control SM

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time to resolution of hemodynamic instability as defined by systemic mean blood pressure > 60mmHg

    Measured: At least 4 hours after discontinuation of vasopressors or inotropes

Secondary outcomes (5)
  1. Length of time with need for organ support (mechanical ventilation, renal-replacement therapy)

    Measured: End of study, expected to be up to 24 weeks

  2. Length of stay in the ICU

    Measured: End of study, expected to be up to 24 weeks

  3. Length of stay in the hospital

    Measured: End of study, expected to be on average 1 year (or until death)

  4. Signs of hypoperfusion or organ dysfunction (Capillary refill time, urinary output, blood lactate levels)

    Measured: 72 hours

  5. Use of conventional hemodynamic monitoring (PA catheter, CVP)

    Measured: 72 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Jan 2014 (estimated)
  2. Study startMar 2014
  3. Primary completion19 Oct 2017
  4. Study completion1 May 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Factorial
Masking
None (open label)
Enrolment
550 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02048566
Sponsor's protocol ID
174/13
Acronym
ImaCor II
Status last verified
Aug 2018
First submitted
21 Jan 2014
Last updated
22 Aug 2018
Results posted
No
Data monitoring committee
No

Publications

  • Vignon P, Mentec H, Terre S, Gastinne H, Gueret P, Lemaire F. Diagnostic accuracy and therapeutic impact of transthoracic and transesophageal echocardiography in mechanically ventilated patients in the ICU. Chest. 1994 Dec;106(6):1829-34. doi: 10.1378/chest.106.6.1829.

    PubMed 7988209
  • Jensen MB, Sloth E, Larsen KM, Schmidt MB. Transthoracic echocardiography for cardiopulmonary monitoring in intensive care. Eur J Anaesthesiol. 2004 Sep;21(9):700-7. doi: 10.1017/s0265021504009068.

    PubMed 15595582
  • Au SM, Vieillard-Baron A. Bedside echocardiography in critically ill patients: a true hemodynamic monitoring tool. J Clin Monit Comput. 2012 Oct;26(5):355-60. doi: 10.1007/s10877-012-9385-6. Epub 2012 Jul 27.

    PubMed 22836724
  • Vieillard-Baron A, Slama M, Mayo P, Charron C, Amiel JB, Esterez C, Leleu F, Repesse X, Vignon P. A pilot study on safety and clinical utility of a single-use 72-hour indwelling transesophageal echocardiography probe. Intensive Care Med. 2013 Apr;39(4):629-35. doi: 10.1007/s00134-012-2797-4. Epub 2013 Jan 4.

    PubMed 23287876
  • Cioccari L, Baur HR, Berger D, Wiegand J, Takala J, Merz TM. Hemodynamic assessment of critically ill patients using a miniaturized transesophageal echocardiography probe. Crit Care. 2013 Mar 27;17(3):R121. doi: 10.1186/cc12793.

    PubMed 23786797
  • Merz TM, Cioccari L, Frey PM, Bloch A, Berger D, Zante B, Jakob SM, Takala J. Continual hemodynamic monitoring with a single-use transesophageal echocardiography probe in critically ill patients with shock: a randomized controlled clinical trial. Intensive Care Med. 2019 Aug;45(8):1093-1102. doi: 10.1007/s00134-019-05670-6. Epub 2019 Jul 4.

    PubMed 31273416
  • Cioccari L, Zante B, Bloch A, Berger D, Limacher A, Jakob SM, Takala J, Merz TM. Effects of hemodynamic monitoring using a single-use transesophageal echocardiography probe in critically ill patients - study protocol for a randomized controlled trial. Trials. 2018 Jul 6;19(1):362. doi: 10.1186/s13063-018-2714-4.

    PubMed 29980233

Questions about this trial

What is this clinical trial studying?

A study testing ImaCor PM and ImaCor SM in people with Shock, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time to resolution of hemodynamic instability as defined by systemic mean blood pressure > 60mmHg (time frame: At least 4 hours after discontinuation of vasopressors or inotropes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02048566, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Aug 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in