DiabetesNCT02053584
Dario™ Blood Glucose Monitoring System - User Performance Evaluation
A study testing Dario™ Blood Glucose Meter and YSI2003 in people with Diabetes, run by LabStyle Innovations Ltd..
Trial summary
The study is performed to evaluate the accuracy of blood glucose level results obtained from fingertip using Labstyle Dario Blood Glucose Monitoring System (BGMS) compared to reference equipment (YSI 2300 STATPLUS) and to evaluate the ease of use of the Dario Device by the lay-person. Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Diabetes
- What is being tested?
- Dario™ Blood Glucose Meter and YSI2003
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 230 participants
- Where
- No sites listed yet
- Study dates
- Jun 2013to Jun 2013
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- Male or female between the age 18 and 80
- Type 1 and Type 2 diabetes
Who cannot join
- Drug and alcohol abuse
- Investigator discretion
About this study
The study is performed to evaluate the accuracy of blood glucose level results obtained from fingertip using Labstyle Dario Blood Glucose Monitoring System (BGMS) compared to reference equipment (YSI 2300 STATPLUS) and to evaluate the ease of use of the Dario Device by the lay-person.
The participants will review the Dario user manual and guide and will be requested to operate the Dario BGMS and perform their own glucose blood test, after which they will be asked to complete a questionnaire. As reference the participants will be tested by professional caregivers both using the Dario BGMS and by YSI 2003.
Read the detailed description
Device accuracy will be assessed based on the acceptance criteria of ISO 15197:2003 which states: "The minimum acceptable accuracy for results produced by a glucose monitoring system shall be as follows: 95% of the individual glucose results shall fall within 15 mg/dL of the results of Reference method at glucose concentrations ≥ 4,2 mmol/L (≥ 75 mg/dL)".
- Conditions
- Diabetes
- Being tested
- Dario™ Blood Glucose Meter, YSI2003
- Medical subject headings
- Diabetes Mellitus
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Dario™ Blood Glucose MeterDevice
Each subject will undergo a finger prick and also provide a venous blood sample
YSI2003Device
Blood samples will be tested using YSI (gold standard) for comparison to evaluate accuracy.
| Study group | Role | What they receive |
|---|---|---|
| Dario BGMS | Experimental | Not described Receives: Device: Dario™ Blood Glucose Meter; Device: YSI2003 |
What is being measured
The primary outcome is the main question the study is designed to answer.
BGMS Accuracy Assessment When Used by Layperson
The minimum acceptable accuracy for results produced by a glucose monitoring system shall be as follows: 95% of the individual glucose results shall fall within 15 mg/dL of the results of reference method (YSI) at glucose concentrations ≥ 4,2 mmol/L (≥ 75 mg/dL). (ISO 15197:2003)
Measured: Within 6 seconds of applying blood drop to strip
Secondary outcomes (1)
Evaluation of the Ease of Use of the Dario BGMS by the Lay-person
Each participant receives a survey to fill in describing their usage of the device and their opinions on the ease of use.
Measured: Within a couple of hours from the time labelling material was provided to the subject
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Feb 2014 (estimated)
- Study startJun 2013
- Primary completionJun 2013
- Study completionJun 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for DiabetesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 230 participants (actual)
Sponsor and investigators
- Lead sponsor
- LabStyle Innovations Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Julio Vainstein, MD, Principal investigator, Wolfson Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02053584
- Sponsor's protocol ID
- CR-0002
- Status last verified
- Jul 2016
- First submitted
- 30 Jan 2014
- Last updated
- 21 Dec 2021
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 21 Dec 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Dario™ Blood Glucose Monitoring System - User Performance Evaluation
- ClinicalTrials.gov ID
- NCT02053584
- Acronym / sponsor ID
- CR-0002
- Conditions
- Diabetes
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 230 participants (actual)
- Lead sponsor
- LabStyle Innovations Ltd.Industry (pharma, biotech, devices)
- Study start
- Jun 2013
- Primary completion
- Jun 2013 (actual)
- Study completion
- Jun 2013 (actual)
- First posted
- 3 Feb 2014 (estimated)
- Results
- Posted 21 Dec 2021
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The study is performed to evaluate the accuracy of blood glucose level results obtained from fingertip using Labstyle Dario Blood Glucose Monitoring System (BGMS) compared to reference equipment (YSI 2300 STATPLUS) and to evaluate the ease of use of the Dario Device by the lay-person.
The participants will review the Dario user manual and guide and will be requested to operate the Dario BGMS and perform their own glucose blood test, after which they will be asked to complete a questionnaire. As reference the participants will be tested by professional caregivers both using the Dario BGMS and by YSI 2003.
Detailed description
Device accuracy will be assessed based on the acceptance criteria of ISO 15197:2003 which states: "The minimum acceptable accuracy for results produced by a glucose monitoring system shall be as follows: 95% of the individual glucose results shall fall within 15 mg/dL of the results of Reference method at glucose concentrations ≥ 4,2 mmol/L (≥ 75 mg/dL)".
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Dario BGMS | Experimental | Device: Dario™ Blood Glucose Meter, Device: YSI2003 |
Who may qualify
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (2 listed)
- Male or female between the age 18 and 80
- Type 1 and Type 2 diabetes
Key exclusion criteria (2 listed)
- Drug and alcohol abuse
- Investigator discretion
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Dario™ Blood Glucose MeterEach subject will undergo a finger prick and also provide a venous blood sample | Device | Dario BGMS |
| YSI2003Blood samples will be tested using YSI (gold standard) for comparison to evaluate accuracy. | Device | Dario BGMS |
Primary outcome
BGMS Accuracy Assessment When Used by Layperson
Time frame: Within 6 seconds of applying blood drop to strip
The minimum acceptable accuracy for results produced by a glucose monitoring system shall be as follows: 95% of the individual glucose results shall fall within 15 mg/dL of the results of reference method (YSI) at glucose concentrations ≥ 4,2 mmol/L (≥ 75 mg/dL). (ISO 15197:2003)
1 secondary outcome
Evaluation of the Ease of Use of the Dario BGMS by the Lay-person
Time frame: Within a couple of hours from the time labelling material was provided to the subject
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Dec 2021.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Diabetes
Not yet recruitingPhase 3
Efficacy and Safety of Once-Weekly SHR-3167 Compared With Once-Daily Insulin Glargine in Adults With Insulin-Naive Type 2 Diabetes
Type 2 Diabetes
Active, not recruiting
Digital Reinforcement of Motivational Interviewing Micro-Skills Among Primary Care Healthcare Professionals
Hypertension (Without Type 2 Diabetes Mellitus)
Recruiting
Effects of Lean Pork Loin Intake on Protein Homeostasis and Glucose Regulation in Prediabetic Adults
Hyperglycaemia (Non Diabetic), Prediabetes
Recruiting
PAW-Hydrogel for Chronic Wound Healing
Diabetic Foot Ulcer (DFU), Pressure Ulcer (PU)
Recruiting
Investigating Vascular Properties of HEMI and SPG Signals in Individuals With or at Risk for Chronic Kidney Disease
Chronic Kidney Disease, Hypertension (HTN)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Julio Vainstein, MD principal investigator
Wolfson Medical Center
Questions about this trial
What is this clinical trial studying?
A study testing Dario™ Blood Glucose Meter and YSI2003 in people with Diabetes, run by LabStyle Innovations Ltd..
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 21 Dec 2021. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 21 Dec 2021). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
BGMS Accuracy Assessment When Used by Layperson (time frame: Within 6 seconds of applying blood drop to strip). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Dec 2021.