Diabetes Mellitus, Type 1TAATNCT02064647
Evaluation of Novel Trend Arrow Adjustment Tool for Diabetes Patients Using Continuous Glucose Monitoring to Guide Insulin Bolus Adjustment (TAAT Study)
A study testing Trend Arrow Adjustment Tool and 10/20% bolus adjustment in people with Diabetes Mellitus, Type 1, run by Children's Hospital of Eastern Ontario at 1 site in Canada.
Trial summary
Continuous glucose monitoring (CGM) provides up to 288 blood glucose levels per day, updated every 5 minutes and displayed in real-time on the insulin pump, which can be used to enhance delivery of insulin through pump therapy. Read more about this study
- Who is it for?
- Ages 5 to 18 years
- Conditions the study is for
- Diabetes Mellitus, Type 1
- What is being tested?
- Trend Arrow Adjustment Tool and 10/20% bolus adjustment
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteCanada
- Study dates
- Jul 2014to May 2015
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 5 to 18 years
- All sexes
- No healthy volunteers
- Child, Adult
Who may be able to join
- Participants will be children and youth aged 5-18 years, attending CHEO diabetes clinic
- Established Type 1 diabetes for more than 1 year,
- Who have used an insulin pump and CGM for at least 3 months.
- Willing to wear iPro2 blinded CGM and to use the Trend Arrow Adjustment Tool and the 10/20% bolus adjustment method.
- Internet access at home (to upload CGM data).
Who cannot join
- Conditions which may interfere with the subject's ability to participate in the study.
- Has received oral and/or intravenous steroid therapy (for any indication, at any dose and/or for any duration) on more than 2 separate occasions in the past 12 months. Use of inhaled and/or topical steroid therapy in the last 12 months does not exclude the subject
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Evaluation of a Novel CGM Trend Arrow Adjustment Tool in Children & Adolescents With Type 1 Diabetes Using Insulin Pump Therapy and Continuous Glucose Monitoring (TAAT Study)
Continuous glucose monitoring (CGM) provides up to 288 blood glucose levels per day, updated every 5 minutes and displayed in real-time on the insulin pump, which can be used to enhance delivery of insulin through pump therapy. In addition this real-time CGM data includes "trend arrows" which indicate when the blood glucose is rapidly falling or rising thus enabling the pump user to make immediate adjustments in insulin delivery to prevent subsequent low or high blood sugars. The trend arrows are displayed when the blood glucose is rapidly falling or rising. For example, if the glucose is increasing by 1-2 mmol/L over 20 minutes, a single upward arrow alerts the pump wearer, who can then decide to give a bolus of insulin or increase the meal bolus. Should the glucose level be increasing at a rate greater than 2mmol/L over 20 minutes, 2 upward arrows are displayed and the user could decide to give a larger bolus. The purpose of the bolus adjustment is to add insulin for the predicted rise in glucose to prevent or reduce subsequent hyperglycemia. Similarly, a decrease in the insulin bolus is advised if glucose levels are falling as evidenced by one or two downward arrows.
However, effective strategies for adjusting insulin boluses based on CGM trend arrows are lacking. The JDRF CGM Study Group recommended that boluses be adjusted based on trend arrows using a standard 10-20% increase/decrease of the total original recommended bolus dose (10% for one arrow up or down, and 20% for two arrows up or down), with the original bolus dose calculated by the pump calculator (i.e. Bolus Wizard). However, the original recommended bolus dose is dependent on the amount of food to be consumed (grams of carbohydrate) and the current blood glucose (if above or below target range), as well as the amount of active insulin, and therefore increasing or decreasing the total recommended bolus by 10-20% may overcompensate for the trend arrows and result in postprandial hypoglycemia. Attempts to use the10/20% formula within CHEO's large pediatric pump/CGM population resulted in low acceptance and adherence by CGM users.
Read more
The CGM TIME Trial Study Group develop an innovative tool for adjusting boluses for CGM trend arrows based on the patient's own insulin sensitivity factor (ISF). The Trend Arrow Adjustment Tool formula is: if CGM shows a single arrow up or down: adjust bolus by +/- (1.5/ISF) and for 2 arrows up or down +/- (3/ISF). Use of the Trend Arrow Adjustment Tool within the CGM TIME Trial appears to lead to more appropriate adjustment in bolus dosing, and more effective prevention of subsequent hyper- and hypoglycemia. Furthermore, this tool appears to have excellent uptake amongst the TIME Trial participants, with observations that there is continued usage of the tool throughout the 12 month study, and greater satisfaction with this component of CGM. However, the tool has not been systematically evaluated.
The proposed study will evaluate the Trend Arrow Adjustment Tool, to determine its effectiveness in reducing postprandial hyper- and hypoglycemia, as well as parent, child/youth satisfaction, and ease of use of the tool based on self-report measures. Comparison will be made with the 10/20% bolus adjustment \& also to no adjustments to meal boluses (i.e. ignoring CGM trend arrows). Should use of the Trend Arrow Adjustment Tool lead to more time spent within the target glucose range, this will have immediate clinical benefit for patients, including improved quality of life, and potentially a reduction in HbA1c and prevention of long-term complications.
Read the detailed description
Detailed protocol:
Phase 1(inpatient evaluation):
This part of the study will take place in a standardized outpatient setting (CHEO Medical Day Unit/Clinic). The CGM trend arrows will be stimulated using two typical clinical scenarios: oral fast acting carbohydrate (to stimulate upward trend arrows) and exercise (to stimulate downward trend arrows).
40 participants will be enrolled in this phase of the study (20 of whom will have oral fast acting carbohydrate and 20 of whom will engage in exercise). Once trend arrows have been triggered, the subjects will receive a standardized meal, and an adjusted insulin bolus. Comparison will be made between the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) and the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group). Phase 1 of the study will lead directly to Phase 2's outpatient evaluation.
Upward CGM trend arrows (Group 1):
- Participants will arrive fasting at the outpatient clinic. They will have been asked to change their pump and CGM the morning of the previous day and to ensure that both are functioning well prior to arrival. An iPro2 (blinded) continuous glucose monitor will be inserted subcutaneously, to provide a second recording of glucose trends. Each subject will be randomized, in a 1:1 ratio, to either the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) or the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group).
- Baseline blood glucose will be checked using a validated blood glucose meter, via capillary sampling.
- At study onset, target blood glucose is 3.6-11mmol/L. If CGM shows trend arrows, the participant will proceed directly to a meal. If there are no upward trend arrows, a preliminary dose of Glucodex (oral fast acting carbohydrate) will be given. The participant will wait for up to one hour or until CGM ↑↑ are triggered, and will then proceed to a meal.
- The participant will be given a standardized meal (containing a fixed amount of carbohydrate, fat and protein, appropriate for subject's weight) and a bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard.
- Glucose levels will be monitored using hourly capillary blood samples, CGM and iPro2. Glucose levels </= 3.5mmol/L or if < 4.0 mmol/L and the subject complains of hypoglycemic symptoms, will be treated as per standard hypoglycemia management plan.
- Glucose monitoring will continue for 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- A second dose of Glucodex will then be given, to trigger trend arrows again. Subjects will wait for one hour or until CGM ↑↑ are triggered, and will then proceed to a second standardized meal.
- A bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard. The same bolus adjustment method will be used for both meals in the same participant.
- Glucose monitoring will continue for a further 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- Prior to discharge, the participant and their parents/guardians, will be trained in the use of the Trend Arrow Adjustment Tool or the 10/20% bolus adjustment formula, (matching the bolus adjustment protocol used in the acute part of the study), and asked to continue to use this for the next 7 days. Participants will be requested to continue to use the iPro2 sensor for 6 days and to upload CGM data daily via Carelink Personal. A log book will be given, to record each time a trend arrow is observed and the methods used to adjust the bolus.
Downward trend arrows (Group 2):
- Subjects will arrive fasting at the outpatient clinic. An iPro2 continuous glucose monitor will be inserted subcutaneously, to provide a second recording of glucose trends. Each subject will be randomized, in a 1:1 ratio, to either the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) or the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group).
- Baseline blood glucose will be checked, via capillary sampling.
- At study onset, blood glucose should be in a 6-11mmol/L target range.
- If CGM shows trend arrows, subjects will proceed directly to a meal.
- If there are no downward trend arrows, the participant will carry out exercise, using a treadmill. Exercise will be for a period of 15 minutes, followed by a 5 minute rest period; and repeated as tolerated until downward trend arrows are triggered. CGM will be monitored for trend arrows. Exercise will be halted if CGM shows ↓↓ or child complains of hypoglycemic symptoms. At this point, capillary blood glucose will be checked. Glucose levels </= 3.5mmol/L, or < 4mmol/L with hypoglycemia symptoms, will be treated according to the standard hypoglycemia management plan.
- The participant will then be given a standardized meal (containing a fixed amount of carbohydrate, fat and protein, appropriate for the subject's weight) and a bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard.
- Glucose levels will be monitored using hourly capillary blood samples and CGM. Any glucose levels </= 3.5mmol/L, or < 4mmol/L with hypoglycemic symptoms, will be treated as per standard hypoglycemia management plan. Glucose monitoring will continue for 3 hours, to obtain an adequate glycemic profile for analysis.
- A second standardized meal will then be given.
- A bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard. The same bolus adjustment method will be used at both time points for the participant.
- Glucose monitoring will continue for a further 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- Prior to discharge, the participant and their parents/guardians, will be trained in the use of the Trend Arrow Adjustment Tool or the 10/20% bolus adjustment formula, (matching the bolus adjustment protocol used in Phase 1 of the study), and asked to continue to use this for the next 7days. Participants will be requested to continue to use the iPro2 sensor for 6 days and to upload CGM data daily via Carelink Personal. A log book will be given, to record each time a trend arrow is observed and the methods used to adjust the bolus.
Protocol Phase 2: Outpatient Evaluation of the Trend Arrow Adjustment Tool
This will be a single site, randomized, controlled, single blinded crossover study, involving the same 40 subjects. Each participant will complete a 3 week assessment. Phase 1 will lead directly into Phase 2.
All subjects and their parents will have received standardized education on insulin pump therapy and CGM, with review and optimization of their basal rates, insulin sensitivity factor(s), and insulin carbohydrate ratios, during the week prior to participation in the study.
For the first week of the study, subjects will administer adjusted meal insulin boluses (i.e. either the Trend Arrow Adjustment Tool, or the 10/20% bolus adjustment formula, whichever they were randomized to receive in Phase 1).
In week 2, subjects will administer standard meal insulin boluses (i.e. using Bolus Wizard recommendations only; ignoring any CGM trend arrows).
In week 3, subjects will crossover to the alternate arm of the study.
Participants will be provided with CGM sensors for use during the study. Each participant will be asked to wear an iPro2 (blinded CGM) during the first 6 days of each week long assessment, to increase CGM data capture. A research co-ordinator will visit the participants at home to insert the iPro2 sensors, at the start of weeks 2 and 3. At the beginning of week 3, the participants and their parents/guardians will be trained in the crossover method of bolus adjustment.
Participants will be given a log book and asked to record each time a trend arrow is observed (at meal times) and whether they adjusted the subsequent meal bolus, as recommended. If the adjustment was not used, they will be asked to explain why they didn't use the recommended bolus adjustment tool.
Participants will be asked to upload to CareLink Personal weekly, throughout the study. Study staff will use CareLink Professional to assess glycemic variability and adherence to diabetes management.
At the end of each week long assessment period, subjects will be given a questionnaire to examine their use and satisfaction with the assigned meal bolus method.
- Conditions
- Diabetes Mellitus, Type 1
- Being tested
- Trend Arrow Adjustment Tool, 10/20% bolus adjustment
- Keywords
- Insulin Infusion Systems, Blood Glucose
- Medical subject headings
- Diabetes Mellitus, Type 1
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Trend Arrow Adjustment ToolOther
The Trend Arrow Adjustment Tool formula is: if CGM shows a single arrow up or down: adjust bolus by +/- (1.5/ISF) and for 2 arrows up or down +/- (3/ISF). Where ISF is the patients own insulin sensitivity factor.
10/20% bolus adjustmentOther
The 10/20% bolus adjustment formula is: if CGM shows a single arrow up or down: adjust bolus by +/- 10% and for 2 arrows up or down +/- 20%.
| Study group | Role | What they receive |
|---|---|---|
| Trend Arrow Adjustment Tool | Experimental | The Trend Arrow Adjustment Tool, uses a formula based on the patients Insulin Sensitivity Factor (ISF) to allow adjustments to meal time insulin boluses, based on CGM trend arrows. Receives: Other: Trend Arrow Adjustment Tool |
| 10/20% bolus adjustment | Active comparator | 10-20% increase/decrease of the total original recommended bolus dose (10% for one arrow up or down, and 20% for two arrows up or down), with the original bolus dose calculated by the pump calculator (i.e. Bolus Wizard). Receives: Other: 10/20% bolus adjustment |
| No adjustment/ignore trend arrows | No intervention | Subjects will ignore the CGM trend arrows, meal time bolus insulin as per Bolus Wizard |
What is being measured
The primary outcome is the main question the study is designed to answer.
Time spent with postprandial glucose level in target range
Glucose target level is 4-10mmol/L post meals
Measured: during 3 week trial
Secondary outcomes (2)
Frequency & duration of postprandial hyperglycemia
Time spent with glucose above 10mmol/L post meals
Measured: during 3 week study period
Frequency & duration of postprandial hypoglycemia
Time spent with glucose <3.9mmolL post meals
Measured: during 3 week study period
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Feb 2014 (estimated)
- Study startJul 2014
- Primary completionApr 2015
- Study completionMay 2015
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Diabetes Mellitus, Type 1Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Investigator
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- Children's Hospital of Eastern Ontario
- Sponsor type
- University, hospital or other
- Collaborators
- Juvenile Diabetes Research Foundation
- Responsible party
- Principal investigator, Margaret Lawson, Children's Hospital of Eastern Ontario
- Investigators
- Margaret Lawson, MD, MSc, MHSc, FRCP, Principal investigator, Children's Hospital of Eastern Ontario Research Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02064647
- Sponsor's protocol ID
- JDRF CCTN
- Acronym
- TAAT
- Status last verified
- Jan 2016
- First submitted
- 14 Feb 2014
- Last updated
- 28 Jan 2016
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 28 Jan 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of a Novel CGM Trend Arrow Adjustment Tool in Children & Adolescents With Type 1 Diabetes Using Insulin Pump Therapy and Continuous Glucose Monitoring (TAAT Study)
- ClinicalTrials.gov ID
- NCT02064647
- Acronym / sponsor ID
- TAAT / JDRF CCTN
- Conditions
- Diabetes Mellitus, Type 1
- Keywords
- Insulin Infusion Systems, Blood Glucose
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- Children's Hospital of Eastern OntarioUniversity, hospital or other
- Collaborators
- Juvenile Diabetes Research Foundation
- Study start
- Jul 2014
- Primary completion
- Apr 2015 (actual)
- Study completion
- May 2015 (actual)
- First posted
- 17 Feb 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Continuous glucose monitoring (CGM) provides up to 288 blood glucose levels per day, updated every 5 minutes and displayed in real-time on the insulin pump, which can be used to enhance delivery of insulin through pump therapy. In addition this real-time CGM data includes "trend arrows" which indicate when the blood glucose is rapidly falling or rising thus enabling the pump user to make immediate adjustments in insulin delivery to prevent subsequent low or high blood sugars. The trend arrows are displayed when the blood glucose is rapidly falling or rising. For example, if the glucose is increasing by 1-2 mmol/L over 20 minutes, a single upward arrow alerts the pump wearer, who can then decide to give a bolus of insulin or increase the meal bolus. Should the glucose level be increasing at a rate greater than 2mmol/L over 20 minutes, 2 upward arrows are displayed and the user could decide to give a larger bolus. The purpose of the bolus adjustment is to add insulin for the predicted rise in glucose to prevent or reduce subsequent hyperglycemia. Similarly, a decrease in the insulin bolus is advised if glucose levels are falling as evidenced by one or two downward arrows.
However, effective strategies for adjusting insulin boluses based on CGM trend arrows are lacking. The JDRF CGM Study Group recommended that boluses be adjusted based on trend arrows using a standard 10-20% increase/decrease of the total original recommended bolus dose (10% for one arrow up or down, and 20% for two arrows up or down), with the original bolus dose calculated by the pump calculator (i.e. Bolus Wizard). However, the original recommended bolus dose is dependent on the amount of food to be consumed (grams of carbohydrate) and the current blood glucose (if above or below target range), as well as the amount of active insulin, and therefore increasing or decreasing the total recommended bolus by 10-20% may overcompensate for the trend arrows and result in postprandial hypoglycemia. Attempts to use the10/20% formula within CHEO's large pediatric pump/CGM population resulted in low acceptance and adherence by CGM users.
The CGM TIME Trial Study Group develop an innovative tool for adjusting boluses for CGM trend arrows based on the patient's own insulin sensitivity factor (ISF). The Trend Arrow Adjustment Tool formula is: if CGM shows a single arrow up or down: adjust bolus by +/- (1.5/ISF) and for 2 arrows up or down +/- (3/ISF). Use of the Trend Arrow Adjustment Tool within the CGM TIME Trial appears to lead to more appropriate adjustment in bolus dosing, and more effective prevention of subsequent hyper- and hypoglycemia. Furthermore, this tool appears to have excellent uptake amongst the TIME Trial participants, with observations that there is continued usage of the tool throughout the 12 month study, and greater satisfaction with this component of CGM. However, the tool has not been systematically evaluated.
The proposed study will evaluate the Trend Arrow Adjustment Tool, to determine its effectiveness in reducing postprandial hyper- and hypoglycemia, as well as parent, child/youth satisfaction, and ease of use of the tool based on self-report measures. Comparison will be made with the 10/20% bolus adjustment \& also to no adjustments to meal boluses (i.e. ignoring CGM trend arrows). Should use of the Trend Arrow Adjustment Tool lead to more time spent within the target glucose range, this will have immediate clinical benefit for patients, including improved quality of life, and potentially a reduction in HbA1c and prevention of long-term complications.
Detailed description
Detailed protocol:
Phase 1(inpatient evaluation):
This part of the study will take place in a standardized outpatient setting (CHEO Medical Day Unit/Clinic). The CGM trend arrows will be stimulated using two typical clinical scenarios: oral fast acting carbohydrate (to stimulate upward trend arrows) and exercise (to stimulate downward trend arrows).
40 participants will be enrolled in this phase of the study (20 of whom will have oral fast acting carbohydrate and 20 of whom will engage in exercise). Once trend arrows have been triggered, the subjects will receive a standardized meal, and an adjusted insulin bolus. Comparison will be made between the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) and the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group). Phase 1 of the study will lead directly to Phase 2's outpatient evaluation.
Upward CGM trend arrows (Group 1):
- Participants will arrive fasting at the outpatient clinic. They will have been asked to change their pump and CGM the morning of the previous day and to ensure that both are functioning well prior to arrival. An iPro2 (blinded) continuous glucose monitor will be inserted subcutaneously, to provide a second recording of glucose trends. Each subject will be randomized, in a 1:1 ratio, to either the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) or the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group).
- Baseline blood glucose will be checked using a validated blood glucose meter, via capillary sampling.
- At study onset, target blood glucose is 3.6-11mmol/L. If CGM shows trend arrows, the participant will proceed directly to a meal. If there are no upward trend arrows, a preliminary dose of Glucodex (oral fast acting carbohydrate) will be given. The participant will wait for up to one hour or until CGM ↑↑ are triggered, and will then proceed to a meal.
- The participant will be given a standardized meal (containing a fixed amount of carbohydrate, fat and protein, appropriate for subject's weight) and a bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard.
- Glucose levels will be monitored using hourly capillary blood samples, CGM and iPro2. Glucose levels </= 3.5mmol/L or if < 4.0 mmol/L and the subject complains of hypoglycemic symptoms, will be treated as per standard hypoglycemia management plan.
- Glucose monitoring will continue for 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- A second dose of Glucodex will then be given, to trigger trend arrows again. Subjects will wait for one hour or until CGM ↑↑ are triggered, and will then proceed to a second standardized meal.
- A bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard. The same bolus adjustment method will be used for both meals in the same participant.
- Glucose monitoring will continue for a further 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- Prior to discharge, the participant and their parents/guardians, will be trained in the use of the Trend Arrow Adjustment Tool or the 10/20% bolus adjustment formula, (matching the bolus adjustment protocol used in the acute part of the study), and asked to continue to use this for the next 7 days. Participants will be requested to continue to use the iPro2 sensor for 6 days and to upload CGM data daily via Carelink Personal. A log book will be given, to record each time a trend arrow is observed and the methods used to adjust the bolus.
Downward trend arrows (Group 2):
- Subjects will arrive fasting at the outpatient clinic. An iPro2 continuous glucose monitor will be inserted subcutaneously, to provide a second recording of glucose trends. Each subject will be randomized, in a 1:1 ratio, to either the Trend Arrow Adjustment Tool (based on the patient's own insulin sensitivity factor) or the standard bolus adjustment recommendations (i.e. +/- 10/20%, based on the STAR 1 Trial and JDRF CGM Study Group).
- Baseline blood glucose will be checked, via capillary sampling.
- At study onset, blood glucose should be in a 6-11mmol/L target range.
- If CGM shows trend arrows, subjects will proceed directly to a meal.
- If there are no downward trend arrows, the participant will carry out exercise, using a treadmill. Exercise will be for a period of 15 minutes, followed by a 5 minute rest period; and repeated as tolerated until downward trend arrows are triggered. CGM will be monitored for trend arrows. Exercise will be halted if CGM shows ↓↓ or child complains of hypoglycemic symptoms. At this point, capillary blood glucose will be checked. Glucose levels </= 3.5mmol/L, or < 4mmol/L with hypoglycemia symptoms, will be treated according to the standard hypoglycemia management plan.
- The participant will then be given a standardized meal (containing a fixed amount of carbohydrate, fat and protein, appropriate for the subject's weight) and a bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard.
- Glucose levels will be monitored using hourly capillary blood samples and CGM. Any glucose levels </= 3.5mmol/L, or < 4mmol/L with hypoglycemic symptoms, will be treated as per standard hypoglycemia management plan. Glucose monitoring will continue for 3 hours, to obtain an adequate glycemic profile for analysis.
- A second standardized meal will then be given.
- A bolus of insulin will be given, via the insulin pump, using either the Trend Arrow Adjustment Tool or the standard 10/20% formula, to adjust the bolus dosage recommended by the bolus wizard. The same bolus adjustment method will be used at both time points for the participant.
- Glucose monitoring will continue for a further 3 hours postprandially, to obtain an adequate glycemic profile for examination.
- Prior to discharge, the participant and their parents/guardians, will be trained in the use of the Trend Arrow Adjustment Tool or the 10/20% bolus adjustment formula, (matching the bolus adjustment protocol used in Phase 1 of the study), and asked to continue to use this for the next 7days. Participants will be requested to continue to use the iPro2 sensor for 6 days and to upload CGM data daily via Carelink Personal. A log book will be given, to record each time a trend arrow is observed and the methods used to adjust the bolus.
Protocol Phase 2: Outpatient Evaluation of the Trend Arrow Adjustment Tool
This will be a single site, randomized, controlled, single blinded crossover study, involving the same 40 subjects. Each participant will complete a 3 week assessment. Phase 1 will lead directly into Phase 2.
All subjects and their parents will have received standardized education on insulin pump therapy and CGM, with review and optimization of their basal rates, insulin sensitivity factor(s), and insulin carbohydrate ratios, during the week prior to participation in the study.
For the first week of the study, subjects will administer adjusted meal insulin boluses (i.e. either the Trend Arrow Adjustment Tool, or the 10/20% bolus adjustment formula, whichever they were randomized to receive in Phase 1).
In week 2, subjects will administer standard meal insulin boluses (i.e. using Bolus Wizard recommendations only; ignoring any CGM trend arrows).
In week 3, subjects will crossover to the alternate arm of the study.
Participants will be provided with CGM sensors for use during the study. Each participant will be asked to wear an iPro2 (blinded CGM) during the first 6 days of each week long assessment, to increase CGM data capture. A research co-ordinator will visit the participants at home to insert the iPro2 sensors, at the start of weeks 2 and 3. At the beginning of week 3, the participants and their parents/guardians will be trained in the crossover method of bolus adjustment.
Participants will be given a log book and asked to record each time a trend arrow is observed (at meal times) and whether they adjusted the subsequent meal bolus, as recommended. If the adjustment was not used, they will be asked to explain why they didn't use the recommended bolus adjustment tool.
Participants will be asked to upload to CareLink Personal weekly, throughout the study. Study staff will use CareLink Professional to assess glycemic variability and adherence to diabetes management.
At the end of each week long assessment period, subjects will be given a questionnaire to examine their use and satisfaction with the assigned meal bolus method.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- Single blind (investigator)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Trend Arrow Adjustment Tool | Experimental | Other: Trend Arrow Adjustment ToolThe Trend Arrow Adjustment Tool, uses a formula based on the patients Insulin Sensitivity Factor (ISF) to allow adjustments to meal time insulin boluses, based on CGM trend arrows. |
| 10/20% bolus adjustment | Active comparator | Other: 10/20% bolus adjustment10-20% increase/decrease of the total original recommended bolus dose (10% for one arrow up or down, and 20% for two arrows up or down), with the original bolus dose calculated by the pump calculator (i.e. Bolus Wizard). |
| No adjustment/ignore trend arrows | No intervention | –Subjects will ignore the CGM trend arrows, meal time bolus insulin as per Bolus Wizard |
Who may qualify
- Ages
- 5 to 18 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult
Key inclusion criteria (5 listed)
- Participants will be children and youth aged 5-18 years, attending CHEO diabetes clinic
- Established Type 1 diabetes for more than 1 year,
- Who have used an insulin pump and CGM for at least 3 months.
- Willing to wear iPro2 blinded CGM and to use the Trend Arrow Adjustment Tool and the 10/20% bolus adjustment method.
- Internet access at home (to upload CGM data).
Key exclusion criteria (2 listed)
- Conditions which may interfere with the subject's ability to participate in the study.
- Has received oral and/or intravenous steroid therapy (for any indication, at any dose and/or for any duration) on more than 2 separate occasions in the past 12 months. Use of inhaled and/or topical steroid therapy in the last 12 months does not exclude the subject
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Trend Arrow Adjustment ToolThe Trend Arrow Adjustment Tool formula is: if CGM shows a single arrow up or down: adjust bolus by +/- (1.5/ISF) and for 2 arrows up or down +/- (3/ISF). Where ISF is the patients own insulin sensitivity factor. | Other | Trend Arrow Adjustment Tool |
| 10/20% bolus adjustmentThe 10/20% bolus adjustment formula is: if CGM shows a single arrow up or down: adjust bolus by +/- 10% and for 2 arrows up or down +/- 20%. | Other | 10/20% bolus adjustment |
Primary outcome
Time spent with postprandial glucose level in target range
Time frame: during 3 week trial
Glucose target level is 4-10mmol/L post meals
2 secondary outcomes
Frequency & duration of postprandial hyperglycemia
Time frame: during 3 week study period
Frequency & duration of postprandial hypoglycemia
Time frame: during 3 week study period
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Jan 2016.
Related trials for Diabetes Mellitus, Type 1
Not yet recruitingPhase 3
A Study to Evaluate the Effectiveness and Safety of the Drug AZD6234 for Managing Weight in Adults Who Are Obese or Overweight. These Participants May or May Not Also Have Type 2 Diabetes
Obesity, Overweight
RecruitingPhase 1
Pharmacokinetics, Safety, and Immunogenicity Comparison of Bmab1700 and Opdivo® as Adjuvant Monotherapy in Participants With Melanoma
Melanoma
Active, not recruitingPhase 2
A Study of Botensilimab and Balstilimab for the Treatment of Colorectal Cancer
Metastatic Colorectal Cancer
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Margaret Lawson, MD, MSc, MHSc, FRCP principal investigator
Children's Hospital of Eastern Ontario Research Institute
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Trend Arrow Adjustment Tool and 10/20% bolus adjustment in people with Diabetes Mellitus, Type 1, run by Children's Hospital of Eastern Ontario at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 28 Jan 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Time spent with postprandial glucose level in target range (time frame: during 3 week trial). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jan 2016.