AzTrials
AzTrials

Coronary Artery DiseaseNCT02073617

Aortic Valve and Root Measurements Under Real-Time 3-Dimensional Visualization During Angiography

A study testing Real-time 3-dimensional DynaCT in people with Coronary Artery Disease and Aortic Stenosis, run by NYU Langone Health at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The American College of Cardiology/American Heart Association guidelines place symptomatic severe Aortic Stenosis as a class I indication for aortic valve replacement. With the recently approved Edwards-Sapien TAVR device and the ongoing investigations using the CoreValve TAVR device, patients ineligible or at high… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease, Aortic Stenosis
What is being tested?
Real-time 3-dimensional DynaCT
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteUnited States
Study dates
6 Jan 2014to 13 Jun 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subjects must be more than 18 years of age with a plan to undergo TAVR.

Who cannot join

  • Subjects will be excluded if they meet one of the following criteria:
  • estimated glomerular filtration rate <40 mL/min/1.73m2;
  • highly irregular heart rates, frequent extra systoles, additional extra pulsations, not in sinus heart rhythm;
  • allergy to contrast media;
  • pregnant; or
  • Unable to consent.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • NYU Langone Medical Center

    New York, New York, 10016

Other trials in United States

About this study

The American College of Cardiology/American Heart Association guidelines place symptomatic severe Aortic Stenosis as a class I indication for aortic valve replacement. With the recently approved Edwards-Sapien TAVR device and the ongoing investigations using the CoreValve TAVR device, patients ineligible or at high risk for open-heart surgery are now eligible to undergo TAVR.

Patients selected for TAVR undergo an EKG-gated cardiac Multislice CTA to evaluate aortic valve anatomy and aortic root dimensions for device sizing, as well as coronary angiography to define coronary anatomy. Both tests utilize contrast media to visualize anatomy, which may result in contrast-induced nephropathy in anywhere from 7.5% to more than 50% of patients depending on associated clinical risk factors.

Read more

There is a need to consolidate this pre-operative testing whenever possible, and with real-time 3-dimensional visualization of aortic valve and root anatomy using DynaCT cardiac acquisition in the cath lab angiography suite during the coronary angiography, there may be a benefit with reduced contrast load (20 to 35cc for DynaCT, 100cc for CTA).

We would like to make a comparison of aortic valve and root measurements using CTA and DynaCT to affirm the accuracy of DynaCT vs the CTA gold standard.

Read the detailed description

Calcific or degenerative aortic valve disease is one of the most common valvular diseases among the elderly and, with life expectancy continuing to increase, a major source of burden on current healthcare. Although patients with aortic stenosis (AS) can remain asymptomatic for a prolonged period, they do eventually develop symptoms, including angina, exertional syncope and heart failure, which is associated with a 5-year, 3-year, and 1-year, respectively, 50% mortality. The American College of Cardiology/American Heart Association guidelines place symptomatic severe AS as a class I indication for aortic valve replacement. Currently, surgical replacement of the aortic valve is the standard of care. However, with the recently approved Edwards-Sapient TAVR device and the ongoing investigations using the CoreValve TAVR device, patients ineligible or at high risk for open-heart surgery are now eligible to undergo TAVR.

Currently, patients selected for TAVR undergo an EKG-gated cardiac Multislice CTA to evaluate aortic valve anatomy and aortic root dimensions for device sizing. Patients also undergo coronary angiography to define coronary anatomy. Both tests utilize contrast media to visualize anatomy, which may result in contrast-induced nephropathy in anywhere from 7.5% to more than 50% of patients depending on associated clinical risk factors. Contrast-induced nephropathy can, in turn, lead to dialysis and/or increased mortality.

There is a need to consolidate this pre-operative testing whenever possible, and with real-time 3-dimensional visualization of aortic valve and root anatomy using DynaCT cardiac acquisition in the cath lab angiography suite during the coronary angiography, there may be a benefit with reduced contrast load (20 to 35cc for DynaCT, 100cc for CTA). DynaCT conducts fully automatic aortic root segmentation and overlays 3-dimensional structures onto 2-dimensional fluoroscopy in a few seconds (~5 seconds, 60 frames/second rotational angiography). The software automatically recognizes and represents the aortic root, detects and indicates coronary ostia and lowest cusp points of aortic valve (nadir points), and reconstructs commissure lines of aortic valve. Due to cardiac motion, 3-dimensional images without motion correction or cardiac gating will look blurred. Therefore, DynaCT reconstruction motion correction software will be used. The DynaCT motion correction software is a new algorithm that will correct for this motion and apply it during reconstruction- allowing the user to spin without using rapid pacing. However, first, a comparison of aortic valve and root measurements using CTA and DynaCT must be made to affirm the accuracy of DynaCT vs the CTA gold standard.

Study Design This is a pilot study evaluating patients undergoing TAVR at the New York University (NYU) Langone Medical Center. Patients will undergo the standard CTA protocol and invasive coronary angiography performed as part of the pre-operative assessment for TAVR. However, patients in this study will also undergo DynaCT during coronary angiography, utilizing 1 acquisition sweep and 20 to 35cc more of contrast media. Measurements of the major aortic annulus diameter, orthogonal minor aortic annulus diameter, aortic annulus perimeter, maximum ascending aorta diameter at 40mm above the annulus, sinus of Valsalva diameters, sinus of Valsalva heights, and aortic root angulation will be made using both the CTA and DynaCT protocols by a radiologist blinded to patient identity after the study has reached its target recruitment. Based on these measurements, a trained interventional cardiologist will select the appropriate TAVR size in a similarly blinded fashion after the study has reached its target recruitment (i.e. the data collected using DynaCT will not be used in the clinical decision making process). Data will be compared from both modalities using appropriate tests of reproducibility and correlation.

Study Technique CTA will be performed per standard methods as part of standard pre-TAVR evaluation.

Coronary angiography will be performed via femoral artery access (minimum 6Fr) as per standard pre-TAVR evaluation. After coronary angiography is performed, a 6Fr pigtail catheter will be placed in the aorta and 40cc of 50% contrast media diluted normal saline will be delivered using standard automated injection during dynaCT cardiac image acquisition. Intravenous delivery of contrast was considered as alternative.

As per standard care, intravenous access will be obtained and participants will be hydrated during the CTA, coronary angiography, and dynaCT procedures.

Being tested
Real-time 3-dimensional DynaCT
Keywords
DynaCT, Aortic valve and root measurements, TAVR
Medical subject headings
Coronary Artery Disease, Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Real-time 3-dimensional DynaCTRadiation

    After coronary angiography is performed, a 6Fr pigtail catheter will be placed in the aorta and 40cc of 50% contrast media diluted normal saline will be delivered using standard automated injection during dynaCT cardiac image acquisition. Intravenous delivery of contrast as alternative.

Study groups in NCT02073617
Study groupRoleWhat they receive
Real-time 3-dimensional DynaCTExperimentalPatients will undergo the standard CTA protocol and invasive coronary angiography performed as part of the pre-operative assessment for TAVR. Patients in this study will also undergo DynaCT during coronary angiography, utilizing 1 acquisition sweep and 20 to 35cc more of contrast media. Measurements of the major aortic annulus diameter, orthogonal minor aortic annulus diameter, aortic annulus perimeter, maximum ascending aorta diameter at 40mm above the annulus, sinus of Valsalva diameters, sinus of Valsalva heights, and aortic root angulation will be made using both the CTA and DynaCT protocols by a radiologist blinded to patient identity. Based on these measurements, a trained interventional cardiologist will select the appropriate TAVR size for the patient.
Receives: Radiation: Real-time 3-dimensional DynaCT

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Correlation of aortic annulus measurement measured on invasive 3D dyna CT (experimental) and on non-invasive CT scan (standard of care)

    Each patient will undergo non-invasive CT scan for aortic annulus measurement (in order to choose appropriate TAVR size) as per standard of care. They will then undergo invasive dyna CT for aortic annulus measurement during their clinically-indicated invasive coronary angiogram. The primary outcome is correlation between the aortic annulus dimension measurement made on dyna CT and non-invasive CT.

    Measured: 1 day

Secondary outcomes (1)
  1. TAVR size

    A trained interventional cardiologist will evaluate the measurements made from each CTA abd DynaCT image and select the appropriate TAVR size in a blinded fashion.

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Feb 2014 (estimated)
  2. Study start6 Jan 2014
  3. Primary completion22 Jun 2016
  4. Study completion13 Jun 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02073617
Sponsor's protocol ID
13-00804
Status last verified
Jul 2017
First submitted
19 Feb 2014
Last updated
18 Jul 2017
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Real-time 3-dimensional DynaCT in people with Coronary Artery Disease and Aortic Stenosis, run by NYU Langone Health at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jul 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Correlation of aortic annulus measurement measured on invasive 3D dyna CT (experimental) and on non-invasive CT scan (standard of care) (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jul 2017.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Clinical Trial NCT02073617 | AzTrials