AzTrials
AzTrials

Evaluate the Agreement and Precision of Device SS-1000 and the Predicate Device the Pentacam in a Reproducibility and Repeatability TrialPASPNCT02077790

To Investigate the Precision and Agreement of SS-1000 and Pentacam in a Repeatability and Reproducibility Trial

A study testing CASIA Cornea/Anterior Segment OCT SS-1000 in people with Evaluate the Agreement and Precision of Device SS-1000 and the Predicate Device the Pentacam in a Reproducibility and Repeatability Trial, run by Tomey Corporation at 1 site in Japan.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study is to support the substantial equivalence of the SS-1000 to the predicate device Pentacam. Primary Objective -The primary objective of the trial is to evaluate the precision of the SS-1000 and Pentacam in measuring the anterior segment parameters in an eye, including Corneal Curvature, Corneal Thickness… Read more about this study

Who is it for?
Ages 22 years and olderHealthy volunteers can take part
What is being tested?
CASIA Cornea/Anterior Segment OCT SS-1000
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
66 participants
Where
1 siteJapan
Study dates
Sep 2013to Dec 2013
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 22 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Female or male age 22 years or older at time of screening
  • Able to fixate at the internal fixation
  • Able to open eyes sufficiently to enable a full image area
  • Written informed consent obtained from subject before any investigational assessment
  • Eyes with one of the following cornea conditions (Francis BA, 2008):
  • Normal cornea (CCT between 511-580 µm with or without pathology)
  • Thin cornea, i.e. previous refractive surgery, corneal ectasia, keratoconus (CCT ≤510 µm with or without pathology)
  • Thick cornea, i.e. Fuchs' dystrophy, bullous keratopathy, corneal edema (CCT >580 µm with or without pathology)

Who cannot join

  • Use of rigid contact lenses within one week from start of trial
  • Use of soft contact lenses within 24 hours of any trial measurement
  • Aphakic eyes
  • Eyes with a history of intraocular, corneal surgery, except refractive surgery
  • Currently on mydriatic and/or miotic medication that can affect ocular physiology
  • Seriously ill or unconscious subject, mentally ill person, mentally handicapped person, person who is unable to read or write

Trial locations and contacts

1 site in 1 country.

Japan1 site
  • Ehime University Hospital

    Shizukawa, Toon, Ehime, 791-0295

Other trials in Japan

About this study

Official title: To Investigate the Precision and Agreement of SS-1000 and the Predicate Device Pentacam in a Repeatability and Reproducibility Trial (PASP)

This study is to support the substantial equivalence of the SS-1000 to the predicate device Pentacam.

Primary Objective -The primary objective of the trial is to evaluate the precision of the SS-1000 and Pentacam in measuring the anterior segment parameters in an eye, including Corneal Curvature, Corneal Thickness, Anterior Chamber Depth and Cornea Volume.

Read more

Secondary Objectives

  • To investigate the repeatability (intra-instrument) of SS-1000 and Pentacam in measuring the anterior segment parameters in an eye
  • To investigate the reproducibility (inter-instrument) of SS-1000 and Pentacam in measuring the anterior segment parameters in an eye
  • To investigate the agreement between SS-1000 and Pentacam in measuring the anterior segment parameters in an eye

Study design

-The trial design is a prospective precision trial with the following factors: The trial will be conducted at one investigational site. The site will have three SS-1000 devices and three Pentacam devices available. Three certified operators (#1, #2 and #3) will be randomly assigned to one set of devices (one SS-1000 and one Pentacam), such that operator effect are confounded with instrument effect. All participants will have one visit and undergo the same set of assessments. Each assessment will consist of 2 consecutive readings (M1, M2).

Read the detailed description
  1. Nonsignificant Risk (NSR) Devices The two devices SS-1000 and Pentacam are considered non-significant risk devices and the conduct of the trial will adhere to the abbreviated requirements of Investigational Device Exemption (21CFR812.2, 2011).
  2. Overall Trial Design The trial design is a prospective precision trial with the following factors: The trial will be conducted at one investigational site. The site will have three SS-1000 devices and three Pentacam devices available. Three certified operators (#1, #2 and #3) will be randomly assigned to one set of devices (one SS-1000 and one Pentacam), such that operator effect are confounded with instrument effect. All participants will have one visit and undergo the same set of assessments. Each assessment will consist of 2 consecutive readings (M1, M2). To ensure the highest physiological stability of the eyes all measurements will be done at least 3 hours after subject awake (Lattimore MR, 1999). To decrease the diurnal variation each subject will have, all measurements excluding screening measurements are performed within a 2 hour window. All measurements are performed in constant dim lighting conditions. Subject will be advised to keep eyes closed between scans to prevent eye dryness. If subject experience eye dryness subject will be allowed extra time to recover between measurements.
  3. Randomization 3.1 Trial eye If subject has one eligible eye with pathology, that eye will be selected as the trial eye. If subject has two eligible eyes, with or without pathology, the trial eye will be randomly selected by tossing a coin (Head=right eye, Tail=left eye). The same eye will be used for all measurements. 3.2 Order of examination Randomization schedule will be generated using a computer and will be used to determine the order of the devices (SS-1000 vs. Pentacam) and the order of the instruments/operators (instrument set #1, instrument set #2 or instrument set #3).
  4. Masking The corneal condition (thin, normal and thick) will not be available to the operators while obtaining data for determination of repeatability and reproducibility.
  5. Discussion of Design The trial design serves the purpose to evaluate the agreement and precision (total precision / repeatability / reproducibility) performance characteristics for SS-1000 and Pentacam. The precision results will be used for the evaluation of substantial equivalence between SS-1000 and Pentacam. This trial is designed to use the same cohort of subjects to minimize between subject variability. Each subject undergoes examination by 3 operators with 3 instruments each and 2 replicates in each condition. This design will provide a head-to head comparison in total precision, agreement, repeatability and reproducibility. The between-operators will be confounded but all assessments in the trial are objective and automatically assessed by both investigational devices. Hence, potential biases should be at a minimum in terms of interpretation of trial results. Potential biases may occur due to the fatigue of subjects and/or the operators. Thus, to minimize biases the order of the devices will be randomly assigned. To avoid other confounding factors (e.g. visit) subjects will have all assessments done at one visit, each subject undergoes 12 measurements. The duration of the tests are estimated to last at least 1 hour which we considered as the upper limit for a subject before fatigue and eye irritation due to dryness. Once a subject starts to experience dryness in the eyes, subject will not be able to fixate and keep the eye open without blinking while the measurement takes place. To prevent eye dryness subject should have his eyes closed between measurements. All devices are evaluated using the same set of subjects and allows for direct comparison of the investigational device and the predicate device.
  6. Trial Population

A total of 66 eyes from 66 subjects meeting all of the following inclusion criteria and none of the exclusion criteria will be recruited:

6.1 Inclusion Criteria

Subjects/eyes who meet each of the following criteria are eligible for the trial:

  • Subject Inclusion Criteria
  1. Female or male age 22 years or older at time of screening
  2. Able to fixate at the internal fixation
  3. Able to open eyes sufficiently to enable a full image area
  4. Written informed consent obtained from subject before any investigational assessment
  • Eye Inclusion Criteria 5.Eyes with one of the following cornea conditions (Francis BA, 2008):
  1. Normal cornea (CCT between 511-580 µm with or without pathology)
  2. Thin cornea, i.e. previous refractive surgery, corneal ectasia, keratoconus (CCT ≤510 µm with or without pathology)
  3. Thick cornea, i.e. Fuchs' dystrophy, bullous keratopathy, corneal edema (CCT >580 µm with or without pathology) 6.2 Exclusion Criteria Eyes who meet one or more of the following criteria are excluded from the trial:
  4. Use of rigid contact lenses within one week from start of trial 2. Use of soft contact lenses within 24 hours of any trial measurement 3. Aphakic eyes 4. Eyes with a history of intraocular, corneal surgery, except refractive surgery 5. Currently on mydriatic and/or miotic medication that can affect ocular physiology 6. Seriously ill or unconscious subject, mentally ill person, mentally handicapped person, person who is unable to read or write When both eyes of a subject are eligible, one eye will be randomly selected. To ensure recruitment of eyes with a range of corneal thicknesses, inclusion criterion no. 5 will be controlled:
  5. Normal cornea (22 eyes)
  6. Thin cornea (22 eyes)
  7. Thick cornea (22 eyes). 6.3 Subject identification All subjects enrolled must be identifiable throughout the trial. This will be done by using a 3-digit subject number starting at 001 allocated to the subject when enrollment is determine by the investigator. 6.4 Subject Withdrawal The subject will be advised in the informed consent form that he/she has the right to withdraw from the trial at any time without reason. The subject may also be withdrawn from the trial at the investigator's or Tomey's discretion at any time. In case a subject drops out of the trial or is withdrawn from the trial, the withdrawal page in the case report form (CRF) should be completed. On the withdrawal page the investigator should record the date of the withdrawal, the person initiating the withdrawal and the primary reason for withdrawal. Subjects withdrawn during trial will not be replaced.
  8. Visit Schedule and Assessments 7.1 Visit The following procedures will be performed at the visit:
  • Obtain written informed consent before any trial procedures are performed
  • Obtain demographic data (age, race, and sex).
  • Obtain corneal characteristics and pathology.
  • Screening with SS-1000 and Pentacam.
  • Recording of concomitant medication.
  • Assess compliance with inclusion and exclusion criteria.
  • Imaging by 3 devices and 3 instruments/operators in a random order o Two readings with SS-1000 (1) by Operator #1 o Two readings with Pentacam (1) by Operator #1
  • Two readings with SS-1000 (2) by Operator #2
  • Two readings with Pentacam (2) by Operator #2
  • Two readings with SS-1000 (3) by Operator #3
  • Two readings with Pentacam (3) by Operator #3
  • AE recording if any has occurred in relation to trial procedures.
Being tested
CASIA Cornea/Anterior Segment OCT SS-1000

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CASIA Cornea/Anterior Segment OCT SS-1000Device

    Also called OCULUS Pentacam Scheimpflug Camera

    The SS-1000 is a three-dimensional, non-contact, non-invasive high resolution optical coherence tomography imaging device based on the principal of "Swept Source" OCT. The system achieves high resolution imaging of 10 μm (Axial) and 30 μm (Transverse) and high speed scanning of 30,000 A-scans per second.

Study groups in NCT02077790
Study groupRoleWhat they receive
Substantial EquivalenceNo interventionThe CASIA Cornea/Anterior Segment OCT SS-1000 was used on all subjects for this study.
Receives: Device: CASIA Cornea/Anterior Segment OCT SS-1000

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Precision

    Corneal Curvature

    1. AKf: axial power value of the flattest meridian [Anterior] (mm)
    2. AKs: axial power value of the steepest meridian [Anterior] (mm)
    3. PKf: axial power value of the flattest meridian [Posterior] (mm)
    4. PKs: axial power value of the steepest meridian [Posterior] (mm)

    Corneal thickness

    1. CCT: thickness value of central cornea (µm)
    2. PCT2: thickness value of peripheral cornea at intersection between the 2-mm diameter circle and the nasal horizontal meridian (µm)
    3. PCT4: thickness value of peripheral cornea at intersection between the 4-mm diameter circle and the nasal horizontal meridian (µm)
    4. PCT6: thickness value of peripheral cornea at intersection between the 6-mm diameter circle and the nasal horizontal meridian (µm)

    ACD: Anterior Chamber Depth (mm)

    Cornea Volume (mm3)

    Measured: within 2 hours

Secondary outcomes (1)
  1. Repeatability, reproducibility and agreement

    1. To investigate the repeatability (intra-instrument) of SS-1000 and Pentacam in measuring the anterior segment parameters in an eye
    2. To investigate the reproducibility (inter-instrument) of SS-1000 and Pentacam in measuring the anterior segment parameters in an eye
    3. To investigate the agreement between SS-1000 and Pentacam in measuring the anterior segment parameters in an eye

    Measured: within 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Mar 2014 (estimated)
  2. Study startSep 2013
  3. Primary completionDec 2013
  4. Study completionDec 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
66 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02077790
Sponsor's protocol ID
684-a01
Acronym
PASP
Status last verified
Mar 2014
First submitted
21 Feb 2014
Last updated
4 Mar 2014
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing CASIA Cornea/Anterior Segment OCT SS-1000 in people with Evaluate the Agreement and Precision of Device SS-1000 and the Predicate Device the Pentacam in a Reproducibility and Repeatability Trial, run by Tomey Corporation at 1 site in Japan.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Mar 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Japan. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Precision (time frame: within 2 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Mar 2014.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in