Stress Urinary IncontinencePhase 3NCT02106299
Safety and Efficacy Study of Regen Sling to Treatment SUI
A Phase 3 study testing Regen sling and tension-free vaginal tape-obturator(TVT-O) in people with Stress Urinary Incontinence, run by Medprin Regenerative Medical Technologies Co., Ltd. at 1 site in China.
Trial summary
To evaluate the treatment safety and efficacy of Regen Sling developed by medprin Regenerative Medical Technologies Co., Ltd. for female patients with stress urinary incontinence Read more about this study
- Who is it for?
- Ages 18 to 75 years, women only
- Conditions the study is for
- Stress Urinary Incontinence
- What is being tested?
- Regen sling and tension-free vaginal tape-obturator(TVT-O)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 178 participants
- Where
- 1 siteChina
- Study dates
- Jan 2014to Dec 2015
- Phase
- Phase 3
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 75 years
- Women only
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 18-75 years old female patients without fertility requirements;
- patients with at least 36-month expected survival time;
- patients meeting the diagnostic criteria of moderate or severe SUI;
- patients meeting follow-up conditions;
- patients having signed the Informed Consent Form.
Who cannot join
- patients with urinary infections or reproductive tract infections;
- patients with significant symptoms of dysuria or other urinary tract obstruction;
- patients with weak detrusor of bladder;
- patients with medical history of neurological diseases, urogenital cancer, fistula and pelvic radiotherapy or patients having received anti-urinary incontinence surgery;
- patients with urge urinary incontinence;
- patients with combined symptomatic POP-Q Ⅱ or severer pelvic organ prolapse or patients with combined overactive bladder syndrome;
- patients with scar constitution or allergic constitution;
- patients with uterine diseases or double adnexal diseases that need surgical treatment proved by pelvic B ultrasonic inspection.
Trial locations and contacts
1 site in 1 country.
China1 site, 1 recruiting
- Recruiting
China
Shenzhen, Guangdong, 510000
Tian Quan, 13580397264, tianquan@medprin.com
Zhu Lan, professor
About this study
Official title: A Multi-Center, Randomized, Controlled Clinical Trial of the Safety and Efficacy of Regen Sling Treatment for Female Patients With Stress Urinary Incontinence
To evaluate the treatment safety and efficacy of Regen Sling developed by medprin Regenerative Medical Technologies Co., Ltd. for female patients with stress urinary incontinence
Read the detailed description
- Stress Urinary Incontinence (SUI) is a disease in which urine outflows involuntarily because of slack and weak urethral sphincter when patient's intra-abdominal pressure increases or patient stands upright or walks. 90% of SUI are caused by urethral hypermobility.
- So far, however, there is no urinary incontinence vaginal tape developed independently by Chinese. By mid-2012, there are more than 10 kinds of vaginal tapes for SUI approved by China Food and Drug Administration(CFDA) and all of them are imported and expensive (price for hospital: 5500-18000 Yuan). By October 18, 2013, all products for SUI treatment approved by CFDA are made in weaving techniques. The main product material is polypropylene, a non-absorbable synthetic mesh. Polypropylene vaginal tapes have good biocompatibility, but Polypropylene vaginal tapes also have many problems. Eckhard Petri's study on the complications of female patients with SUI treated by polypropylene vaginal tape showed that postoperative complications often occur in the 5th year after the surgery. The most common complications include mesh exposure, pain, infection and sexual dysfunction. The causes of these complications are mainly related to the material's biocompatibility and rejection reaction etc in addition to surgical factors.
- The Regen Sling developed by Medprin Regenerative Medical Technologies Co., Ltd. adopts the high-biocompatibility Polyvinylidene Fluoride (PVDF) as the material and electro-spinning technique is adopted for its production. It is highly flexible, non-erosive, permanent and non-degradable.In addition, it can induce rapid ingrowth of fibroblasts and new blood capillary formation, thus achieving perfect remediation effect and long-term safety. The Regen Sling can effectively prevent the various problems of the existing products occurred in clinical use and overcome the deficiencies of existing polypropylene weaving products such as poor comfortable sensation, easy to induce erosion and exposure etc.
- Given the technical advantages and development potentials of Regen Sling and the market demands, Sponsor plan to apply for the registration of the product in the United States (FDA) in addition to domestic application for registration; besides, Sponsor plan to conduct European unification(CE) certification for the product in the European Economic Area and apply for registration in other potential countries or regions.
- Product Mechanism and Trial Range 5.1 Product Mechanism Pathogenesis of SUI include urethral hypermobility and internal sphincter disorder, 90% of SUI are caused by urethral hypermobility. Delancey created the Hammock Theory in 1994 and pointed out that the key of SUI treatment is to restore the supporting tissue around urethra instead of changing the positions and included angle of bladder and urethra. Mid urethral sling is the generic term of the surgical methods for female SUI treatment derived from the theory. It is effective and minimally invasive and becomes the internationally recognized first line treatment of SUI. In Regen Sling treatment, vaginal tape is placed at the middle section of urethra without tension through puncture method, so the dynamic urethral resistance is obtained in abdominal pressure increasing state, thus achieving urinary control effect. 5.2 Trial Range Female patients with moderate or severe SUI
- Product Indications and Function 1) This product is applicable for female patients with moderate or severe SUI; 2) Moderate to severe SUI caused by internal sphincter disorder; 3) Mixed urinary incontinence.
- Research Method The study is a multi-center, randomized, single-blind, positive parallel controlled, non-inferiority validation clinical trial.
7.1. Investigators shall observe and determine whether the hospitalized patients planning to undergo female stress urinary incontinence surgery meet the inclusion criteria or not. If the patients meet the inclusion criteria, the investigators shall explain Informed Consent Form to the patients. If the patients agree to participate in the clinical trial, they can become the subjects of the trial only when the Informed Consent Form is signed by the patients and/or patients family member.
7.2. The investigators shall screen out and register the subjects, complete relevant examinations in baseline period; for the patients meeting inclusion criteria without rejecting the Informed Consent Form, investigators shall allocate random number to the patients in chronological order (random number allocation method: Small to large).
7.3. All subjects shall undergo routine preoperative examinations including Blood Routine, Urine Routine, Blood Type and Rh antibody , Liver and Kidney Function, Blood Coagulation Function, Hepatitis B Five Items, Hepatitis C Virus(HCV) Antibodies, Treponema Pallidum Antibodies, Preliminary HIV Screening, Electrocardiogram, Chest Radiography, Pelvic Cavity B Ultrasound etc and preoperative pelvic floor function assessment and preoperative questionnaire.
7.4. During the operation of vaginal tape, investigators shall place the control samples and test samples in accordance with standard operations and complete relevant surgical records.
7.5. Follow-up Observation: outpatient follow-up shall be conducted in the 3rd month, 6th month and 12th month after the surgery. According to the clinical requirements, in the 3rd month after the surgery, investigators shall examine surgery's anti-urinary incontinence effect and encourage the patients to recover sexual life; in the 6th month after the surgery, investigators shall conduct follow-up visits on sexual life situation and vaginal tape erosion situation; in the 12th month after the surgery,investigators shall know about the improvement of patients' symptoms .
- Conditions
- Stress Urinary Incontinence
- Being tested
- Regen sling, tension-free vaginal tape-obturator(TVT-O)
- Medical subject headings
- Urinary Incontinence, Stress
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Regen slingDevice
Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a Regen sling (medprin).
tension-free vaginal tape-obturator(TVT-O)Device
Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a transobturator sling TVT-O™ (gynecare™, USA).
| Study group | Role | What they receive |
|---|---|---|
| Regen Sling | Experimental | Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a Regen Sling (medprin). Receives: Device: Regen sling |
| tension-free vaginal tape-obturator | Active comparator | Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a transobturator sling TVT-O™ (gynecare™, USA). Receives: Device: tension-free vaginal tape-obturator(TVT-O) |
What is being measured
The primary outcome is the main question the study is designed to answer.
pressure test (subjective indicator)
After patients in lithotomy position during bladder filling period continuously vigorously cough, we can observe whether urine leaks from the urethral orifice; if urine leakage does not occur in supine position, the patients shall stand with feet separated in shoulder width and continuously cough for several times, then we shall observe whether urine leakage occurs or not.
Measured: 1 year
one-hour pad test(objective indicator)
- The bladder shall be full for one hour and patient shall not urinate after the test starts;
- Place accurately weighed urine pad in advance (such as sanitary napkin);
- The patient drinks 500ml of water within 15 minutes after the test starts and then rests in bed;
- The patient shall walk and walk up and down the stairs of one floor during the subsequent 30 minutes;
- During the last 15 minutes, the patient shall stand up and sit down for 10 times, cough heavily for 10 times, run for 1 minute, pick up 5 items on the floor and use tap water to wash hands for 1 minute.
Measured: 1 year
Secondary outcomes (2)
Urinary Incontinence Impact Questionnaire - Table 7.(IIQ-7)
Measured: 1 year
Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire - Table 12. (PISQ-12)
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Apr 2014 (estimated)
- Study startJan 2014
- Primary completionDec 2014 (estimated)
- Study completionDec 2015 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Stress Urinary IncontinenceStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 3
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 178 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Medprin Regenerative Medical Technologies Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Zhu Lan, professor, Principal investigator, Peking Union Medical College Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02106299
- Sponsor's protocol ID
- MP201303
- Status last verified
- Apr 2014
- First submitted
- 31 Mar 2014
- Last updated
- 8 Apr 2014
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Apr 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Multi-Center, Randomized, Controlled Clinical Trial of the Safety and Efficacy of Regen Sling Treatment for Female Patients With Stress Urinary Incontinence
- ClinicalTrials.gov ID
- NCT02106299
- Acronym / sponsor ID
- MP201303
- Conditions
- Stress Urinary Incontinence
- Phase
- Phase 3
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 178 participants (estimated)
- Lead sponsor
- Medprin Regenerative Medical Technologies Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- Jan 2014
- Primary completion
- Dec 2014 (estimated)
- Study completion
- Dec 2015 (estimated)
- First posted
- 8 Apr 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To evaluate the treatment safety and efficacy of Regen Sling developed by medprin Regenerative Medical Technologies Co., Ltd. for female patients with stress urinary incontinence
Detailed description
- Stress Urinary Incontinence (SUI) is a disease in which urine outflows involuntarily because of slack and weak urethral sphincter when patient's intra-abdominal pressure increases or patient stands upright or walks. 90% of SUI are caused by urethral hypermobility.
- So far, however, there is no urinary incontinence vaginal tape developed independently by Chinese. By mid-2012, there are more than 10 kinds of vaginal tapes for SUI approved by China Food and Drug Administration(CFDA) and all of them are imported and expensive (price for hospital: 5500-18000 Yuan). By October 18, 2013, all products for SUI treatment approved by CFDA are made in weaving techniques. The main product material is polypropylene, a non-absorbable synthetic mesh. Polypropylene vaginal tapes have good biocompatibility, but Polypropylene vaginal tapes also have many problems. Eckhard Petri's study on the complications of female patients with SUI treated by polypropylene vaginal tape showed that postoperative complications often occur in the 5th year after the surgery. The most common complications include mesh exposure, pain, infection and sexual dysfunction. The causes of these complications are mainly related to the material's biocompatibility and rejection reaction etc in addition to surgical factors.
- The Regen Sling developed by Medprin Regenerative Medical Technologies Co., Ltd. adopts the high-biocompatibility Polyvinylidene Fluoride (PVDF) as the material and electro-spinning technique is adopted for its production. It is highly flexible, non-erosive, permanent and non-degradable.In addition, it can induce rapid ingrowth of fibroblasts and new blood capillary formation, thus achieving perfect remediation effect and long-term safety. The Regen Sling can effectively prevent the various problems of the existing products occurred in clinical use and overcome the deficiencies of existing polypropylene weaving products such as poor comfortable sensation, easy to induce erosion and exposure etc.
- Given the technical advantages and development potentials of Regen Sling and the market demands, Sponsor plan to apply for the registration of the product in the United States (FDA) in addition to domestic application for registration; besides, Sponsor plan to conduct European unification(CE) certification for the product in the European Economic Area and apply for registration in other potential countries or regions.
- Product Mechanism and Trial Range 5.1 Product Mechanism Pathogenesis of SUI include urethral hypermobility and internal sphincter disorder, 90% of SUI are caused by urethral hypermobility. Delancey created the Hammock Theory in 1994 and pointed out that the key of SUI treatment is to restore the supporting tissue around urethra instead of changing the positions and included angle of bladder and urethra. Mid urethral sling is the generic term of the surgical methods for female SUI treatment derived from the theory. It is effective and minimally invasive and becomes the internationally recognized first line treatment of SUI. In Regen Sling treatment, vaginal tape is placed at the middle section of urethra without tension through puncture method, so the dynamic urethral resistance is obtained in abdominal pressure increasing state, thus achieving urinary control effect. 5.2 Trial Range Female patients with moderate or severe SUI
- Product Indications and Function 1) This product is applicable for female patients with moderate or severe SUI; 2) Moderate to severe SUI caused by internal sphincter disorder; 3) Mixed urinary incontinence.
- Research Method The study is a multi-center, randomized, single-blind, positive parallel controlled, non-inferiority validation clinical trial.
7.1. Investigators shall observe and determine whether the hospitalized patients planning to undergo female stress urinary incontinence surgery meet the inclusion criteria or not. If the patients meet the inclusion criteria, the investigators shall explain Informed Consent Form to the patients. If the patients agree to participate in the clinical trial, they can become the subjects of the trial only when the Informed Consent Form is signed by the patients and/or patients family member.
7.2. The investigators shall screen out and register the subjects, complete relevant examinations in baseline period; for the patients meeting inclusion criteria without rejecting the Informed Consent Form, investigators shall allocate random number to the patients in chronological order (random number allocation method: Small to large).
7.3. All subjects shall undergo routine preoperative examinations including Blood Routine, Urine Routine, Blood Type and Rh antibody , Liver and Kidney Function, Blood Coagulation Function, Hepatitis B Five Items, Hepatitis C Virus(HCV) Antibodies, Treponema Pallidum Antibodies, Preliminary HIV Screening, Electrocardiogram, Chest Radiography, Pelvic Cavity B Ultrasound etc and preoperative pelvic floor function assessment and preoperative questionnaire.
7.4. During the operation of vaginal tape, investigators shall place the control samples and test samples in accordance with standard operations and complete relevant surgical records.
7.5. Follow-up Observation: outpatient follow-up shall be conducted in the 3rd month, 6th month and 12th month after the surgery. According to the clinical requirements, in the 3rd month after the surgery, investigators shall examine surgery's anti-urinary incontinence effect and encourage the patients to recover sexual life; in the 6th month after the surgery, investigators shall conduct follow-up visits on sexual life situation and vaginal tape erosion situation; in the 12th month after the surgery,investigators shall know about the improvement of patients' symptoms .
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Regen Sling | Experimental | Device: Regen slingSubjects of this group were submitted to surgical treatment of stress urinary incontinence with a Regen Sling (medprin). |
| tension-free vaginal tape-obturator | Active comparator | Device: tension-free vaginal tape-obturator(TVT-O)Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a transobturator sling TVT-O™ (gynecare™, USA). |
Who may qualify
- Ages
- 18 to 75 years
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- 18-75 years old female patients without fertility requirements;
- patients with at least 36-month expected survival time;
- patients meeting the diagnostic criteria of moderate or severe SUI;
- patients meeting follow-up conditions;
- patients having signed the Informed Consent Form.
Key exclusion criteria (8 listed)
- patients with urinary infections or reproductive tract infections;
- patients with significant symptoms of dysuria or other urinary tract obstruction;
- patients with weak detrusor of bladder;
- patients with medical history of neurological diseases, urogenital cancer, fistula and pelvic radiotherapy or patients having received anti-urinary incontinence surgery;
- patients with urge urinary incontinence;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Regen slingSubjects of this group were submitted to surgical treatment of stress urinary incontinence with a Regen sling (medprin). | Device | Regen Sling |
| tension-free vaginal tape-obturator(TVT-O)Subjects of this group were submitted to surgical treatment of stress urinary incontinence with a transobturator sling TVT-O™ (gynecare™, USA). | Device | tension-free vaginal tape-obturator |
Primary outcome
pressure test (subjective indicator)
Time frame: 1 year
After patients in lithotomy position during bladder filling period continuously vigorously cough, we can observe whether urine leaks from the urethral orifice; if urine leakage does not occur in supine position, the patients shall stand with feet separated in shoulder width and continuously cough for several times, then we shall observe whether urine leakage occurs or not.
one-hour pad test(objective indicator)
Time frame: 1 year
* The bladder shall be full for one hour and patient shall not urinate after the test starts; * Place accurately weighed urine pad in advance (such as sanitary napkin); * The patient drinks 500ml of water within 15 minutes after the test starts and then rests in bed; * The patient shall walk and walk up and down the stairs of one floor during the subsequent 30 minutes; * During the last 15 minutes, the patient shall stand up and sit down for 10 times, cough heavily for 10 times, run for 1 minute, pick up 5 items on the floor and use tap water to wash hands for 1 minute.
2 secondary outcomes
Urinary Incontinence Impact Questionnaire - Table 7.(IIQ-7)
Time frame: 1 year
Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire - Table 12. (PISQ-12)
Time frame: 1 year
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Apr 2014.
Related trials for Stress Urinary Incontinence
RecruitingPhase 3
A Study of Orforglipron in Female Participants With Stress Urinary Incontinence Who Have Obesity or Overweight
Urinary Incontinence,Stress
Active, not recruitingObservational study
Return to Physical Activity After Retropublic Transvaginal Sling and Laparoscopic Sacrocolpopexy
Stress Urinary Incontinence, Pelvic Organ Prolapse
RecruitingPhase 1
Allogeneic Use of Expanded Mesenchymal Stem Cells Derived From Adipose Tissue (HC106), Female Urinary Incontinence Women Over 50 Years Old
Urinary Incontinence Stress
Recruiting
The Application of Somatosensory Interactive Pelvic Floor Muscle Training for Stress Urinary Incontinence in Men Underwent Radical Prostatectomy
Prostate Cancer (Post Prostatectomy)
RecruitingObservational study
Standardized 4D Transperineal Ultrasound Assessment of Urethrovesical Junction Mobility After Vaginal Laser Treatment for Stress Urinary Incontinence.
Urinary Incontinence , Stress, Laser Therapy
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Zhu Lan, professor principal investigator
Peking Union Medical College Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 3 study testing Regen sling and tension-free vaginal tape-obturator(TVT-O) in people with Stress Urinary Incontinence, run by Medprin Regenerative Medical Technologies Co., Ltd. at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 8 Apr 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Tian Quan (13580397264, tianquan@medprin.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
pressure test (subjective indicator) (time frame: 1 year). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Apr 2014.