Coronary Artery DiseaseREST-PETNCT02117284
Rubidium Elution System Performance Testing
An observational study of Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 4 sites in Canada.
Trial summary
Rubidium is a newly approved nuclear medicine imaging drug or 'tracer' used to look at blood flow in the heart. This tracer is given using a special pump called an 'elution system' which is considered investigational. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- How many people
- 15,800 participants
- Where
- 4 sitesCanada
- Study dates
- Jan 2014to Sep 2018
- How long will I take part?
- 1 Day
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph.
Who may be able to join
- All patients presenting to participating nuclear imaging facilities with Rb-82 PET for diagnosis and/or risk stratification for CAD (as listed in the approved Ruby-Fill product monograph), who are at least 18 years of age and have given informed consent or those who have consented to and are currently participating in an Ottawa Health Science Network Research Ethics Board (OHSN-REB) approved protocol utilizing Rb-82 PET will be eligible.
Who cannot join
- Patients with contraindications to stress radionuclide imaging including:
- Severe reactive airway disease;
- <3 days post myocardial infarction (MI) or acute coronary syndrome (ACS) presentation;
- Unstable crescendo angina;
- High grade atrioventricular (AV) block;
- Severe claustrophobia;
- Patients who are or may be pregnant will be excluded.
Trial locations and contacts
4 sites in 1 country.
Canada4 sites
Hamilton Healath Sciences Centre
Hamilton, Ontario
London Health Sciences Centre
London, Ontario
University of Ottawa Heart Institute
Ottawa, Ontario, K1Y 4W7
University Health Network
Toronto, Ontario
About this study
Rubidium is a newly approved nuclear medicine imaging drug or 'tracer' used to look at blood flow in the heart. This tracer is given using a special pump called an 'elution system' which is considered investigational. This means the device is not yet approved by Health Canada for general use, but it has been approved for use in this study. It has been used routinely in this hospital since 2010.
The purpose of this study is to confirm proper operation of the pump. It may also help identify areas for future improvement. The study data may be used for safety reporting to the Ministry of Health or to Health Canada. The study will enroll 2,400 patients in 6 hospitals across Canada. The University of Ottawa Heart Institute (UOHI) will enroll up to 1,200 patients.
Read the detailed description
Primary Objectives: To evaluate performance of the rubidium elution systems (RBES) manufactured by Jubilant DraxImage (JDI); specifically using the constant-activity-rate intravenous infusion of rubidium-82 from the Ruby-Fill™ generator for diagnostic imaging of myocardial perfusion with PET. The V3 elution system is more highly automated, therefore requiring fewer manual performance checks.
Hypotheses:
- Performance: system operation using constant-activity infusion is adequate to achieve:
- elution activity (82Rb) bias < 5% (V2 and V3)
- elution activity (82Rb) imprecision < 5% (V2 and V3)
- elution time interval (30 s) bias < 5% (V2 only)
- elution success-rate reliability > 98% (failure-rate < 2%) (V2 and V3)
- Daily Quality Assurance: testing procedures are adequate to document:
- Automated generator yield (82Rb) imprecision < 10% (V2 only)
- Automated generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 and V3)
- Manual generator yield (82Rb) imprecision < 10% (V2 only)
- Manual generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 only)
- Monthly Quality Assurance: testing procedures are adequate to document:
- Dose calibrator non-linearity < 1% (V2 and V3)
- Dose calibrator constancy > 99% (instability < 1%) (V2 only)
- Dose calibrator bias < 10% (V2 only)
- Peristaltic pump calibration bias < 10% (V2 only) 2.2 Secondary Objectives: To evaluate the user documentation and training reliability for:
- Installation of the Ruby-Fill generator and Ruby-Set tubing (V2 and V3)
- Trouble-shooting and repair of system errors (e.g. high-pressure) (V2 and V3) 2.3 Tertiary Objective: To evaluate patient demographics or health status effects on system performance
- Conditions
- Coronary Artery Disease
- Keywords
- positron emission tomography (PET), Rubidium-82, myocardial perfusion imaging, automated elution system, controlled radioactivity delivery
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
| Study group | Role | What they receive |
|---|---|---|
| Coronary artery disease | All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph. |
What is being measured
The primary outcome is the main question the study is designed to answer.
System Performance:
System operation using constant-activity infusion is adequate to achieve:
- elution activity (82Rb) bias < 5% (V2 and V3)
- elution activity (82Rb) imprecision < 5% (V2 and V3)
- elution time interval (30 s) bias < 5% (V2 only)
- elution success-rate reliability > 98% (failure-rate < 2%) (V2 and V3)
Measured: 1 year
Daily Quality Assurance:
System testing procedures are adequate to document:
- Automated generator yield (82Rb) imprecision < 10% (V2 only)
- Automated generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 and V3)
- Manual generator yield (82Rb) imprecision < 10% (V2 only)
- Manual generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 only)
Measured: 1 year
Monthly Quality Assurance
System testing procedures are adequate to document:
- Dose calibrator non-linearity < 1% (V2 and V3)
- Dose calibrator constancy > 99% (instability < 1%) (V2 only)
- Dose calibrator bias < 10% (V2 only)
- Peristaltic pump calibration bias < 10% (V2 only)
Measured: 1 year
Secondary outcomes (1)
User documentation
To evaluate the user documentation and training reliability for:
- Installation of the Ruby-Fill generator and Ruby-Set tubing (V2 and V3)
- Trouble-shooting and repair of system errors (e.g. high-pressure) (V2 and V3)
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Apr 2014 (estimated)
- Study startJan 2014
- Primary completionSep 2018
- Study completionSep 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 15,800 participants (actual)
- Target duration
- 1 Day
Sponsor and investigators
- Lead sponsor
- Ottawa Heart Institute Research Corporation
- Sponsor type
- University, hospital or other
- Collaborators
- Jubilant DraxImage Inc.
- Responsible party
- Principal investigator, Rob Beanlands, Ottawa Heart Institute Research Corporation
- Investigators
- Rob S Beanlands, MD, Principal investigator, Ottawa Heart Institute Research Corporation
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02117284
- Sponsor's protocol ID
- 20130344
- Acronym
- REST-PET
- Status last verified
- May 2018
- First submitted
- 15 Apr 2014
- Last updated
- 24 Dec 2018
- Results posted
- No
- Data monitoring committee
- No
Publications
Klein R, Adler A, Beanlands RS, Dekemp RA. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007 Feb 7;52(3):659-73. doi: 10.1088/0031-9155/52/3/009. Epub 2007 Jan 11.
PubMed 17228112
Study at a glance
From the registry record, last updated by the sponsor on 24 Dec 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Rubidium Elution System Performance Testing
- ClinicalTrials.gov ID
- NCT02117284
- Acronym / sponsor ID
- REST-PET / 20130344
- Conditions
- Coronary Artery Disease
- Keywords
- positron emission tomography (PET), Rubidium-82, myocardial perfusion imaging, automated elution system, controlled radioactivity delivery
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 15,800 participants (actual)
- Lead sponsor
- Ottawa Heart Institute Research CorporationUniversity, hospital or other
- Collaborators
- Jubilant DraxImage Inc.
- Study start
- Jan 2014
- Primary completion
- Sep 2018 (actual)
- Study completion
- Sep 2018 (actual)
- First posted
- 17 Apr 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Rubidium is a newly approved nuclear medicine imaging drug or 'tracer' used to look at blood flow in the heart. This tracer is given using a special pump called an 'elution system' which is considered investigational. This means the device is not yet approved by Health Canada for general use, but it has been approved for use in this study. It has been used routinely in this hospital since 2010.
The purpose of this study is to confirm proper operation of the pump. It may also help identify areas for future improvement. The study data may be used for safety reporting to the Ministry of Health or to Health Canada. The study will enroll 2,400 patients in 6 hospitals across Canada. The University of Ottawa Heart Institute (UOHI) will enroll up to 1,200 patients.
Detailed description
Primary Objectives: To evaluate performance of the rubidium elution systems (RBES) manufactured by Jubilant DraxImage (JDI); specifically using the constant-activity-rate intravenous infusion of rubidium-82 from the Ruby-Fill™ generator for diagnostic imaging of myocardial perfusion with PET. The V3 elution system is more highly automated, therefore requiring fewer manual performance checks.
Hypotheses:
- Performance: system operation using constant-activity infusion is adequate to achieve:
- elution activity (82Rb) bias < 5% (V2 and V3)
- elution activity (82Rb) imprecision < 5% (V2 and V3)
- elution time interval (30 s) bias < 5% (V2 only)
- elution success-rate reliability > 98% (failure-rate < 2%) (V2 and V3)
- Daily Quality Assurance: testing procedures are adequate to document:
- Automated generator yield (82Rb) imprecision < 10% (V2 only)
- Automated generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 and V3)
- Manual generator yield (82Rb) imprecision < 10% (V2 only)
- Manual generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 only)
- Monthly Quality Assurance: testing procedures are adequate to document:
- Dose calibrator non-linearity < 1% (V2 and V3)
- Dose calibrator constancy > 99% (instability < 1%) (V2 only)
- Dose calibrator bias < 10% (V2 only)
- Peristaltic pump calibration bias < 10% (V2 only) 2.2 Secondary Objectives: To evaluate the user documentation and training reliability for:
- Installation of the Ruby-Fill generator and Ruby-Set tubing (V2 and V3)
- Trouble-shooting and repair of system errors (e.g. high-pressure) (V2 and V3) 2.3 Tertiary Objective: To evaluate patient demographics or health status effects on system performance
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Target follow-up
- 1 Day
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Coronary artery disease | – | –All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph.
Key inclusion criteria (1 listed)
- All patients presenting to participating nuclear imaging facilities with Rb-82 PET for diagnosis and/or risk stratification for CAD (as listed in the approved Ruby-Fill product monograph), who are at least 18 years of age and have given informed consent or those who have consented to and are currently participating in an Ottawa Health Science Network Research Ethics Board (OHSN-REB) approved protocol utilizing Rb-82 PET will be eligible.
Key exclusion criteria (7 listed)
- Patients with contraindications to stress radionuclide imaging including:
- Severe reactive airway disease;
- <3 days post myocardial infarction (MI) or acute coronary syndrome (ACS) presentation;
- Unstable crescendo angina;
- High grade atrioventricular (AV) block;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
System Performance:
Time frame: 1 year
System operation using constant-activity infusion is adequate to achieve: 1. elution activity (82Rb) bias < 5% (V2 and V3) 2. elution activity (82Rb) imprecision < 5% (V2 and V3) 3. elution time interval (30 s) bias < 5% (V2 only) 4. elution success-rate reliability > 98% (failure-rate < 2%) (V2 and V3)
Daily Quality Assurance:
Time frame: 1 year
System testing procedures are adequate to document: 1. Automated generator yield (82Rb) imprecision < 10% (V2 only) 2. Automated generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 and V3) 3. Manual generator yield (82Rb) imprecision < 10% (V2 only) 4. Manual generator breakthrough (82Sr, 85Sr) imprecision < 10% (V2 only)
Monthly Quality Assurance
Time frame: 1 year
System testing procedures are adequate to document: 1. Dose calibrator non-linearity < 1% (V2 and V3) 2. Dose calibrator constancy > 99% (instability < 1%) (V2 only) 3. Dose calibrator bias < 10% (V2 only) 4. Peristaltic pump calibration bias < 10% (V2 only)
1 secondary outcome
User documentation
Time frame: 1 year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Dec 2018.
- Background: PubMed 17228112Klein R, Adler A, Beanlands RS, Dekemp RA. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007 Feb 7;52(3):659-73. doi: 10.1088/0031-9155/52/3/009. Epub 2007 Jan 11.
Related trials for Coronary Artery Disease
Not yet recruitingPhase 1/2
EDIT-401 in Adults Who Require Additional Lowering of Low-Density Lipoprotein Cholesterol (LDL-C)
Heterozygous Familial Hypercholesterolemia (HeFH)
Active, not recruitingPhase 3
Coronary Computed Tomography Study to Assess the Effect of Inclisiran in Addition to Maximally Tolerated Statin Therapy on Atherosclerotic Plaque Progression in Participants With a Diagnosis of Non-obstructive Coronary Artery Disease Without Previous Cardiovascular Events
Coronary Artery Disease
RecruitingObservational study
Characterization of Patients With Uncommon Presentations and/or Uncommon Diseases Associated With the Cardiovascular System
Metabolic Disease, Obesity
Active, not recruiting
Troponin in Acute Chest Pain to Risk Stratify and Guide EffecTive Use of Computed Tomography Coronary Angiography
Coronary Artery Disease
Recruiting
A Prospective, Multicenter, Randomized Controlled Trial to Investigate the Value of Coronary CT Angiography in the Understanding and Management of Coronary Calcium (The Optimal Trial)
Cardiovascular Diseases, Myocardial Ischemia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Rob S Beanlands, MD principal investigator
Ottawa Heart Institute Research Corporation
4 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 4 sites in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
System Performance: (time frame: 1 year). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02117284, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Dec 2018.