Weaning FailurePhase 4NCT02122016

Comparison of Two Different Types of Mechanical Ventilation Weaning in Patients in the ICU

A Phase 4 study testing SmartCare and Conventional weaning protocol in people with Weaning Failure, run by Hospital Israelita Albert Einstein at 2 sites in Brazil.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Mechanical ventilation is widely used for ICU patients as a lifesaving procedure. However, it is associated with several complications, such as ventilator-associated pneumonia and the increase of hospital morbidity and mortality. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Weaning Failure
What is being tested?
SmartCare and Conventional weaning protocol
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
70 participants
Where
2 sitesBrazil
Study dates
Jun 2011to May 2012
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Recovery from the causes that had led to mechanical ventilation
  • Capacity to initiate a spontaneous breathing effort
  • Spontaneous eye opening and responsiveness even with low doses of sedation
  • Oxygen inspired fraction lower than 50% with oxygen pulse oximeter higher than 95%
  • Positive end-expiratory pressure under 10 cmH2O
  • Hemodynamic stability
  • Vasopressor drugs lower than 0.05mcg/ml/kg

Who cannot join

  • Tracheotomized patients
  • Neurological sequels with a poor prognostic (post cardiorespiratory arrest or central neurological injury)
  • Glasgow scale lower than 10

Trial locations and contacts

2 sites in 1 country.

Brazil2 sites
  • Hospital Israelita Albert Einstein

    São Paulo, São Paulo, 05652-900

  • Hospital Israelita Albert Einstein's Critically Ill Department

    São Paulo, São Paulo, 05652900

Other trials in Brazil

About this study

Official title: Weaning With Smartcare in Mechanically Ventilated Patients in the ICU - a Controlled and Randomized Study

Mechanical ventilation is widely used for ICU patients as a lifesaving procedure. However, it is associated with several complications, such as ventilator-associated pneumonia and the increase of hospital morbidity and mortality. To avoid such complications, we need to wean these patients off the ventilator as soon as possible. This must however be done at the right time to avoid other complications, such as the need for re-intubation. For this reason, it is important to have a specific weaning protocol, which will reduce the time on mechanical ventilation, and avoiding the need for re-intubation and other complications. Recently, an argument has developed as to which weaning protocol would be more appropriated, and whether a computer driven weaning protocol could have better results than the conventional weaning protocols focusing on daily screening and daily interruption of sedation followed by a spontaneous breathing test. Our objective is to compare mechanical ventilation times, weaning success up to 48 hours after extubation, re-intubation rates between a group with computer driven weaning protocol (SmartCare) versus a weaning protocol with daily weaning screens and spontaneous breathing trials in ICU patients ventilated for more than 24 hours.

Read the detailed description

Background: Mechanical ventilation (MV) weaning is commonly performed using Spontaneous Breathing Trials (SBT) with pressure support ventilation after a daily weaning screen [1]. Recently there has been an increased interest in automatic weaning trials, which consists of closed-loop ventilation, using ETCO2 monitoring during SBT [1, 2]. So far, there has been no clinical evidence to compare automatic weaning trials with those of SBT.

Objective: To compare MV weaning times between an Automatic Weaning Ventilation System (SmartCare/PS) and SBT groups.

Methods: A randomized, controlled study performed at a general ICU. Adult patients were enrolled who were ventilated for more than 24 hours. Tracheostomies patients, those with neurological conditions, and a Glasgow coma scales lower than 10 were excluded. Patients were randomized to either the control or Smart Care group. All patients were ventilated with a Drager Evita XL (Drager Medical, Lubeck, Germany) ventilator with SmartCare/PS software version 1.1 available for use immediately prior to randomization. The Control group consisted of a daily weaning screen and SBT with pressure support ventilation. If patients tolerated SBT, they were extubated. Smart Care group patients were also submitted to a daily weaning screen, after which they were ventilated with the SmartCare/PS mode. MV and weaning time, maximum inspiratory pressure (MIP), maximum expiratory pressure (MEP), vital capacity (VC), respiratory frequency to tidal volume ration (f/Vt), use of non-invasive ventilation (NIV) post extubation, and re-intubation rate we evaluated.

Conditions
Weaning Failure
Being tested
SmartCare, Conventional weaning protocol
Keywords
Ventilator weaning, Protocols, Computer driven weaning, Decision Making, Computer-Assisted, Therapy, Computer-Assisted, Respiration, Artificial
Medical subject headings
Respiratory Aspiration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SmartCareDevice

    Ventilator with a SmartCare module that is capable of performing a computer-driven weaning trial taking into account patients lung mechanics and exaled CO2.

  • Conventional weaning protocolOther

    A conventional weaning protocol performed by physiotherapist with a daily weaning screen and a spontaneous breathing trial

Study groups in NCT02122016
Study groupRoleWhat they receive
SmartCareExperimentalA computer driven weaning ventilator, using closed-loop ventilation, taking into account patients lung mechanics and exhaled CO2.
Receives: Device: SmartCare
Conventional weaning protocolActive comparatorA conventional weaning protocol consisting of a daily weaning screen, which is performed by physiotherapist. All patients who are mechanically ventilated for more than 24 hours are given a spontaneous breathing trial.
Receives: Other: Conventional weaning protocol

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Weaning time from mechanical ventilation

    The duration that patient's received mechanical ventilation until they were extubated comparing two weaning protocols (computer driven v daily weaning screen and spontaneous breathing trial).

    Measured: From June 2011 to April 2012 an 11 month period

Secondary outcomes (2)
  1. weaning success

    Evaluate the rate of weaning success of patients under mechanical ventilation. Success defined as patient not needing re-intubation up to 48 hours after extubation.

    Measured: From June 2011 to April 2012 an 11 month period

  2. re-intubation rate

    Evaluate the re-intubation rate of patients that were extubated.

    Measured: From June 2011 to April 2012 an 11 month period

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Apr 2014 (estimated)
  2. Study startJun 2011
  3. Primary completionApr 2012
  4. Study completionMay 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
70 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02122016
Sponsor's protocol ID
SmartCare\HIAE11
Status last verified
Apr 2014
First submitted
27 Aug 2013
Last updated
24 Apr 2014
Results posted
No
Data monitoring committee
No

Publications

  • Taniguchi C, Victor ES, Pieri T, Henn R, Santana C, Giovanetti E, Saghabi C, Timenetsky K, Caserta Eid R, Silva E, Matos GF, Schettino GP, Barbas CS. Smart Care versus respiratory physiotherapy-driven manual weaning for critically ill adult patients: a randomized controlled trial. Crit Care. 2015 Jun 11;19(1):246. doi: 10.1186/s13054-015-0978-6.

    PubMed 26580673

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing SmartCare and Conventional weaning protocol in people with Weaning Failure, run by Hospital Israelita Albert Einstein at 2 sites in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 24 Apr 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Weaning time from mechanical ventilation (time frame: From June 2011 to April 2012 an 11 month period). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02122016, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Apr 2014.