IVUS Controlled Stenting

A study testing Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent) and Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent) in people with Coronary Angioplasty and Stenting and Single de Novo Coronary Artery Stenoses, run by Sydney South West Area Health Service at 1 site in Australia.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Stent placement is now widely accepted to improve the results of angioplasty (an operation to widen the blood vessel) and decreasing the need for further surgery. Despite their worldwide acceptance, stent usage is still limited by renarrowing which occurs within the stent (restenosis) in some patients within the first… Read more about this study

Who is it for?
Ages 18 to 85 years
What is being tested?
Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent) and Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteAustralia
Study dates
Feb 2014to Nov 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 85 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients who are scheduled for a coronary angioplasty and stenting
  • Single de novo artery stenosis are eligible for this study
  • Target lesion needs to be less than 30mm long and located in a vessel more than 2.5 mm in diameter

Who cannot join

  • Contraindication to antiplatelet therapy;
  • Ostial lesion;
  • Excessive vessel tortuosity;
  • Lesion at a significant bifurcation (subbranch ≥ 2mm in diameter);
  • Suspected intracoronary thrombus.

Trial locations and contacts

1 site in 1 country.

Australia1 site
  • Department of Cardiology

    Liverpool, New South Wales, 2170

Other trials in Australia

About this study

Official title: Expansion of Intracoronary Stents by Low Pressure Oversizing Versus High Pressure Inflation: A Randomised Intracoronary Ultrasound Controlled Study

Stent placement is now widely accepted to improve the results of angioplasty (an operation to widen the blood vessel) and decreasing the need for further surgery. Despite their worldwide acceptance, stent usage is still limited by renarrowing which occurs within the stent (restenosis) in some patients within the first six months. In addition there still exists a small risk of heart attacks soon after the stent is placed.

The purpose of this study is to test the safety and tolerability of trying to place the stents using a different strategy of using low pressure oversized balloon inflations as opposed to the usual high pressure balloon inflations. This may reduce injury to the artery and reduce the chance of renarrowing of the stent. In order to ensure this is a safe and effective way of performing the procedure the investigators intend to use an Intravascular ultrasound (IVUS) catheter to look from inside the artery at the stents. IVUS has proven to be the best way of ensuring optimal stent placement.

Read more

Primary hypothesis: Stents will be equally well expanded and apposed using a strategy of oversized stenting at normal inflation pressures ( < 10 atmospheres ) as compared to high pressure inflation (≥14 atmospheres) as guided by intravascular ultrasound imaging.

Secondary Hypothesis: There will be no difference in acute clinical endpoints (death, myocardial infarction, urgent revascularisation or stent thrombosis) using a strategy of oversized stenting at normal inflation pressure as compared to high pressure inflation.

Tertiary Hypothesis: If the above is shown to be true the investigators would hope to expand the study in order to reveal a decrease in stent restenosis using a strategy of lower pressure balloon inflations. The investigators will assess the deployment characteristics of drug eluting versus bare metal stents

Being tested
Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent), Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)
Keywords
Patients scheduled to undergo coronary angioplasty and stenting because of symptoms related to a single de novo coronary artery stenoses

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)Device

    Stent can include both bare metal stents and drug eluting stents. Depending on availabilities, different stent brands may be used.

  • Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)Device

    Stent can include both bare metal stents and drug eluting stents. Depending on availabilities, different stent brands may be used.

Study groups in NCT02128412
Study groupRoleWhat they receive
Stent oversize groupActive comparatorOversized stent deployed at low pressure: A stent premounted on a balloon with a nominal diameter halfway between the lumen diameter and the true vessel diameter (approximated by external elastic lamina) as assessed by IVUS. This will be based on the smallest of the vessel reference diameters proximal and distal to the lesion. In addition the vessel diameter must be greater than this diameter throughout the length of the lesion. This stent will be implanted at an inflation pressure of 10 atmospheres or less for at least 15 seconds and a second IVUS will be performed to assess the end point.
Receives: Device: Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)
High pressure groupActive comparatorStent deployed at high pressure: A stent premounted on a balloon with a nominal diameter approximately equal to the vessel segment lumen reference diameter as previously assessed by IVUS will be used. This stent will be implanted at an inflation pressure of 14 atmospheres or more for at least 15 seconds and a second IVUS will be performed to assess the end point
Receives: Device: Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of stents which are optimally deployed as assessed against the MUSIC criteria

    The criteria for optimal stent expansion are:

    1. Complete apposition of the stent over its entire length against the vessel wall.

    2a. In stent minimal luminal area (MLA) >= 90% of the average reference luminal area or >=100% of lumen area of the reference segment with the lowest lumen area.

    In stent lumen area of proximal stent entrance >= 90% of proximal lumen area. 2b. Where the instent luminal area is in excess of 9.0 mm2 , the following criteria apply: In stent MLA > 80% of the average reference lumen area or >=90% of lumen area of the reference segment with the lowest lumen area.

    In stent lumen area of proximal stent entrance >= 90% of proximal lumen area. 3. Symmetric stent expansion defined by lumen diameter (LD)min / LD max >= 0.7

    A less rigorous criteria for stent expansion will also be assessed:

    1. In stent MLA > 80% of the average reference lumen area; \&
    2. Complete apposition of the stent over its entire length against the vessel wall

    Measured: Immediately after stent is deployed until optimal deployment is achieved

Secondary outcomes (1)
  1. Clinical endpoints including death, myocardial infarction, coronary artery bypass surgery, repeat percutaneous intervention, stent thrombosis, myonecrosis

    Measured: 1-3 days following procedure and at 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 May 2014 (estimated)
  2. Study startFeb 2014
  3. Primary completionOct 2016
  4. Study completionNov 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
40 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02128412
Sponsor's protocol ID
2013/167
Status last verified
Oct 2016
First submitted
28 Apr 2014
Last updated
17 Oct 2016
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Oversized stent deployed at low pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent) and Stent deployed at high pressure (Multi-Link Bare Metal Stent or Xience Prime Evenolimus Eluting Stent) in people with Coronary Angioplasty and Stenting and Single de Novo Coronary Artery Stenoses, run by Sydney South West Area Health Service at 1 site in Australia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Oct 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Australia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of stents which are optimally deployed as assessed against the MUSIC criteria (time frame: Immediately after stent is deployed until optimal deployment is achieved). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.