ProlapseNCT02156687
Randomized Trial of Y Mesh vs Dual Mesh
A study testing Y mesh and Dual flat mesh in people with Prolapse, run by The Cleveland Clinic at 1 site in United States.
Trial summary
The primary objective of the proposed study is to determine the difference in suturing time when using the restorelle Y mesh versus the restorelle dual flat mesh at the time of laparoscopic and robotic-assisted laparoscopic sacrocolpopexy. Read more about this study
- Who is it for?
- Ages 18 to 100 years, women only
- Conditions the study is for
- Prolapse
- What is being tested?
- Y mesh and Dual flat mesh
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 59 participants
- Where
- 1 siteUnited States
- Study dates
- 14 Apr 2014to 1 Apr 2020
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 100 years
- Women only
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age ≥ 18, who are to undergo laparoscopic or robotic laparoscopic sacrocolpopexy for pelvic organ prolapse
- Other concomitant laparoscopic or prolapse and anti-incontinence procedures (e.g., laparoscopic supracervical hysterectomy, cystocele repair, rectocele repair or mid-urethral sling procedures) will be performed at the primary surgeon's discretion.
Who cannot join
- Inability to comprehend written and/or spoken English
- Inability to provide informed consent
- Medical illness precluding laparoscopy
- Need for concomitant surgeries not related to pelvic organ prolapse or incontinence
- Sacrocolpoperineopexy
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Prospective Randomized Trial Comparing Restorelle Y Mesh vs. Restorelle Dual Flat Mesh for Laparoscopic and Robotic-assisted Laparoscopic Sacrocolpopexy
The primary objective of the proposed study is to determine the difference in suturing time when using the restorelle Y mesh versus the restorelle dual flat mesh at the time of laparoscopic and robotic-assisted laparoscopic sacrocolpopexy.
Hypothesis: Suturing time when using the restorelle Y mesh will be faster than when using the restorelle dual flat mesh at the time of laparoscopic and robotic-assisted laparoscopic sacrocolpopexy.
Read the detailed description
Study Design: Randomized single-blind prospective clinical trial
Primary Outcomes:
- Total Suturing time for mesh placement = time from insertion of Y mesh or first flat mesh arm into pelvis to last sacral suture placed
- Total Case time = Incision to end of closure
Secondary Outcomes:
Post-operative patient outcomes at 24-months
- Pelvic Floor Dysfunction Inventory (PFDI-20)
- Pelvic Organ Prolapse Distress Inventory (POPDI)
- Colorectal Anal Distress Inventory (CRADI)
- Urogenital Distress Inventory (UDI)
- Objective Recurrence (POP-Q)
- Subjective Recurrence (vaginal bulge)
- Reported mesh erosion
Study Population: Study subjects will be recruited from patients that present to the Center of Urogynecology and Pelvic Floor Disorders in the Department of Obstetrics and Gynecology at the Cleveland Clinic main campus, Hillcrest Hospital and Fairview Hospital, and their surgeries will be performed at either one of these sites.
Study Procedures:
Study Identification and Recruitment Potential subjects will be identified by members of the Center for Urogynecology and Pelvic Reconstructive Surgery at the Cleveland Clinic main campus and Fairview Hospital. Eligible patients that agree to participate will be provided written informed consent administered by the collaborators listed on this Investigational Research Board (IRB) proposal at Cleveland Clinic Main campus and Fairview Hospitals.
Randomization All subjects will be predetermined by their surgeon to undergo either a laparoscopic or robotic assisted laparoscopic sacrocolpopexy depending upon their clinical evaluation. The participants will then be randomized to either Y mesh or dual flat mesh sacrocolpopexy according to a computer-generated randomization schedule with random block sizes with the use of the SAS statistical software package (SAS Institute, Cary, NC). Randomization will be carried out by provider. All patients will be blinded to their assignment.
Office Interventions In addition to a standardized evaluation including the history and physical examination, patients will be asked to complete the Pelvic Floor Distress Inventory (PFDI-20) questionnaire at the pre-operative visit as well as the 6, 12 and 24-month postoperative visit. Completion of these questionnaire is the only additional assessment that is specific to participation in this study and is not usually included as part of the standard care of sacrocolpopexy. It should take no more than 10-15 minutes to complete the questionnaire. The study subjects will not be exposed to any additional risk by participating in this study except for the inconvenience of completing the questionnaire.
Surgical Interventions Laparoscopic sacrocolpopexy will be performed using four ports: an umbilical port for the laparoscope, two ports (either 5 or 10/12 mm) in the bilateral lower quadrants, and one 5-mm port placed at the level of the umbilicus, lateral to the rectus muscle on either side for retraction. The robotic-assisted hysterectomy will be performed using the da Vinci Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) using five ports: a 12mm umbilical port for the laparoscopic, two 8 mm robotic ports placed 2cm inferior and 9-10cm lateral to the umbilicus bilaterally, an 8mm robotic port placed in the left axillary line at the level of the umbilicus, and a 8mm or 10/12mm accessory port either in the right upper quadrant approximately 3cm distal from the costal margin, or in the right lower quadrant, 2cm above and medial to the anterior superior iliac spine.
If a supracervical hysterectomy is to be performed, it will be done in a standard fashion. A uterine manipulator will be placed inside of the uterus. The round ligaments will be transected using cautery. The fallopian tubes and ovaries will be left in situ or removed at the time of hysterectomy depending upon the preoperative decision made between the surgeon and patient. The uterine arteries and cardinal ligaments will be cauterized laparoscopically. The uterus will be amputated at the level of the internal cervical os and the endocervical canal will be cauterized.
The sacrocolpopexy will also be performed and in a standard fashion. An end-to-end anastomosis (EEA) sizer will be placed in the vagina for manipulation of the apex as well as in the rectum for delineation of the rectovaginal septum. First, the presacral dissection will be performed with a longitudinal peritoneal incision over the sacral promontory and there is identification of the anterior longitudinal ligament. Dissection is then done caudally through the peritoneum and subperitoneal fat down to the level of the posterior cul-de-sac. The vagina is elevated cephalad using the EEA sizer and the peritoneum overlying the anterior vaginal apex is incised transversely, and the bladder is dissected off the anterior vagina using sharp dissection, creating a 4 to 5 cm pocket. If this plane is difficult to establish, the bladder will be filled in a retrograde fashion to find the correct dissection plane. Similarly, the peritoneum overlying the posterior vagina is incised, and dissection is then done overlying the vagina and extending into the posterior cul-de-sac, creating a 4 to 5 cm pocket. Once dissection is complete, the mesh graft is prepared. Subjects will have been randomized to either one of two mesh grafts:
- Restorelle Y mesh
- The mesh is introduced into the pelvis through one of the ports.
- First, either then anterior or the posterior arm is fixed to the anterior or posterior vaginal wall using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The opposing arm of the graft is then attached to either the anterior or posterior vaginal wall, depending on which arm was placed first, in a similar fashion using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The stem portion of the graft is then brought to the sacral promontory and sutured to the anterior longitudinal ligament using 2 permanent (prolene) No. 0 sutures. The excess mesh is then trimmed.
- Restorelle dual flat mesh: 2 pieces of 15 x 4 cm mesh
- One mesh arm is introduced into the pelvis through one of the ports.
- The arm is fixed to the anterior or posterior vaginal wall using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The second mesh arm is then introduced into the pelvis through one of the ports.
- The arm is fixed to either the anterior or posterior vaginal wall, depending on where the first arm was placed, using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The two arms are then brought to the sacral promontory and sutured together to the anterior longitudinal ligament using 2 permanent (prolene) No. 0 sutures. The excess mesh is then trimmed.
The peritoneum is then closed over the exposed graft with absorbable suture. Routine cystoscopy will also be performed in order to assess for lower urinary tract injury. A vaginal exam is performed, and an anterior and/or posterior colporrhaphy and perineorrhaphy are performed if needed. Anti-incontinence procedures may also be performed if needed.
**In laparoscopic cases, all suturing will be done extracorporeally while intracorporeal knot-tying technique will be performed in robot assisted laparoscopic cases.
- Conditions
- Prolapse
- Being tested
- Y mesh, Dual flat mesh
- Medical subject headings
- Prolapse
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Y meshDevice
Also called Cololast, Inc. Restorell Y mesh
Y mesh
Dual flat meshDevice
Also called Coloplast, Inc. Restorelle Dual flat mesh
Dual flat mesh
| Study group | Role | What they receive |
|---|---|---|
| Cololast, Inc. Restorell Y mesh | Active comparator | Y mesh Receives: Device: Y mesh |
| Coloplast, Inc. Restorelle Dual flat mesh | Active comparator | Dual flat mesh Receives: Device: Dual flat mesh |
What is being measured
The primary outcome is the main question the study is designed to answer.
Total Suturing Time for Mesh Placement = Time From Insertion of Y Mesh or First Flat Mesh Arm Into Pelvis to Last Sacral Suture Placed
Measured: one day intraoperative
Total OR Time = Operating Room Time of Entry and Exit
Measured: one day intraoperative
Secondary outcomes (6)
Post-operative Mean Difference POPDI at 24 Months
Mean difference between baseline (pre-procedure) and 24-months post-procedure. The POPDI is a six-item measure from the PFDI-20 which measures 6 different pelvic organ prolapse symptoms and degree of bother. The scale exists from 0-100 (0=no symptoms, 100=worse symptoms).
Measured: 24 months
Postoperative Mean Difference CRADI at 24 Months
Mean difference between baseline (pre-procedure) and 24-months post-procedure. The CRADI is a eight-item measure from the PFDI-20 which measures 8 different pelvic organ prolapse symptoms and degree of bother. The scale exists from 0-100 (0=no symptoms, 100=worse symptoms).
Measured: 24 months
Postoperative Mean Difference UDI at 24 Months
Mean difference between baseline (pre-procedure) and 24-months post-procedure. The UDI is a six-item measure from the PFDI-20 which measures 6 different pelvic organ prolapse symptoms and degree of bother. The scale exists from 0-100 (0=no symptoms, 100=worse symptoms).
Measured: 24 months
Postoperative Subjective Recurrence at 24 Months
Subjective Recurrence was defined as patients who complained of vaginal bulge symptoms (Question #3 on the PFDI-20).
Measured: 24 months
Postoperative Objective Recurrence at 24 Months
Objective Recurrence
Measured: 24 months
Reported Mesh Erosion at 24 Months
Mesh Erosion was defined as presence of eroded mesh in the vagina on examination postoperatively up to 24-months after surgery.
Measured: 24 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted5 Jun 2014 (estimated)
- Study start14 Apr 2014
- Primary completion7 Nov 2019
- Study completion1 Apr 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for ProlapseStudies of the same condition, open and under way.
- More trials run by The Cleveland ClinicThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 59 participants (actual)
Sponsor and investigators
- Lead sponsor
- The Cleveland Clinic
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Cecile Unger, M.D., Principal investigator, The Cleveland Clinic
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02156687
- Sponsor's protocol ID
- 14-354
- Status last verified
- Nov 2020
- First submitted
- 2 Jun 2014
- Last updated
- 24 Nov 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 24 Nov 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective Randomized Trial Comparing Restorelle Y Mesh vs. Restorelle Dual Flat Mesh for Laparoscopic and Robotic-assisted Laparoscopic Sacrocolpopexy
- ClinicalTrials.gov ID
- NCT02156687
- Acronym / sponsor ID
- 14-354
- Conditions
- Prolapse
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 59 participants (actual)
- Lead sponsor
- The Cleveland ClinicUniversity, hospital or other
- Study start
- 14 Apr 2014 (actual)
- Primary completion
- 7 Nov 2019 (actual)
- Study completion
- 1 Apr 2020 (actual)
- First posted
- 5 Jun 2014 (estimated)
- Results
- Posted 29 Oct 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The primary objective of the proposed study is to determine the difference in suturing time when using the restorelle Y mesh versus the restorelle dual flat mesh at the time of laparoscopic and robotic-assisted laparoscopic sacrocolpopexy.
Hypothesis: Suturing time when using the restorelle Y mesh will be faster than when using the restorelle dual flat mesh at the time of laparoscopic and robotic-assisted laparoscopic sacrocolpopexy.
Detailed description
Study Design: Randomized single-blind prospective clinical trial
Primary Outcomes:
- Total Suturing time for mesh placement = time from insertion of Y mesh or first flat mesh arm into pelvis to last sacral suture placed
- Total Case time = Incision to end of closure
Secondary Outcomes:
Post-operative patient outcomes at 24-months
- Pelvic Floor Dysfunction Inventory (PFDI-20)
- Pelvic Organ Prolapse Distress Inventory (POPDI)
- Colorectal Anal Distress Inventory (CRADI)
- Urogenital Distress Inventory (UDI)
- Objective Recurrence (POP-Q)
- Subjective Recurrence (vaginal bulge)
- Reported mesh erosion
Study Population: Study subjects will be recruited from patients that present to the Center of Urogynecology and Pelvic Floor Disorders in the Department of Obstetrics and Gynecology at the Cleveland Clinic main campus, Hillcrest Hospital and Fairview Hospital, and their surgeries will be performed at either one of these sites.
Study Procedures:
Study Identification and Recruitment Potential subjects will be identified by members of the Center for Urogynecology and Pelvic Reconstructive Surgery at the Cleveland Clinic main campus and Fairview Hospital. Eligible patients that agree to participate will be provided written informed consent administered by the collaborators listed on this Investigational Research Board (IRB) proposal at Cleveland Clinic Main campus and Fairview Hospitals.
Randomization All subjects will be predetermined by their surgeon to undergo either a laparoscopic or robotic assisted laparoscopic sacrocolpopexy depending upon their clinical evaluation. The participants will then be randomized to either Y mesh or dual flat mesh sacrocolpopexy according to a computer-generated randomization schedule with random block sizes with the use of the SAS statistical software package (SAS Institute, Cary, NC). Randomization will be carried out by provider. All patients will be blinded to their assignment.
Office Interventions In addition to a standardized evaluation including the history and physical examination, patients will be asked to complete the Pelvic Floor Distress Inventory (PFDI-20) questionnaire at the pre-operative visit as well as the 6, 12 and 24-month postoperative visit. Completion of these questionnaire is the only additional assessment that is specific to participation in this study and is not usually included as part of the standard care of sacrocolpopexy. It should take no more than 10-15 minutes to complete the questionnaire. The study subjects will not be exposed to any additional risk by participating in this study except for the inconvenience of completing the questionnaire.
Surgical Interventions Laparoscopic sacrocolpopexy will be performed using four ports: an umbilical port for the laparoscope, two ports (either 5 or 10/12 mm) in the bilateral lower quadrants, and one 5-mm port placed at the level of the umbilicus, lateral to the rectus muscle on either side for retraction. The robotic-assisted hysterectomy will be performed using the da Vinci Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) using five ports: a 12mm umbilical port for the laparoscopic, two 8 mm robotic ports placed 2cm inferior and 9-10cm lateral to the umbilicus bilaterally, an 8mm robotic port placed in the left axillary line at the level of the umbilicus, and a 8mm or 10/12mm accessory port either in the right upper quadrant approximately 3cm distal from the costal margin, or in the right lower quadrant, 2cm above and medial to the anterior superior iliac spine.
If a supracervical hysterectomy is to be performed, it will be done in a standard fashion. A uterine manipulator will be placed inside of the uterus. The round ligaments will be transected using cautery. The fallopian tubes and ovaries will be left in situ or removed at the time of hysterectomy depending upon the preoperative decision made between the surgeon and patient. The uterine arteries and cardinal ligaments will be cauterized laparoscopically. The uterus will be amputated at the level of the internal cervical os and the endocervical canal will be cauterized.
The sacrocolpopexy will also be performed and in a standard fashion. An end-to-end anastomosis (EEA) sizer will be placed in the vagina for manipulation of the apex as well as in the rectum for delineation of the rectovaginal septum. First, the presacral dissection will be performed with a longitudinal peritoneal incision over the sacral promontory and there is identification of the anterior longitudinal ligament. Dissection is then done caudally through the peritoneum and subperitoneal fat down to the level of the posterior cul-de-sac. The vagina is elevated cephalad using the EEA sizer and the peritoneum overlying the anterior vaginal apex is incised transversely, and the bladder is dissected off the anterior vagina using sharp dissection, creating a 4 to 5 cm pocket. If this plane is difficult to establish, the bladder will be filled in a retrograde fashion to find the correct dissection plane. Similarly, the peritoneum overlying the posterior vagina is incised, and dissection is then done overlying the vagina and extending into the posterior cul-de-sac, creating a 4 to 5 cm pocket. Once dissection is complete, the mesh graft is prepared. Subjects will have been randomized to either one of two mesh grafts:
- Restorelle Y mesh
- The mesh is introduced into the pelvis through one of the ports.
- First, either then anterior or the posterior arm is fixed to the anterior or posterior vaginal wall using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The opposing arm of the graft is then attached to either the anterior or posterior vaginal wall, depending on which arm was placed first, in a similar fashion using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The stem portion of the graft is then brought to the sacral promontory and sutured to the anterior longitudinal ligament using 2 permanent (prolene) No. 0 sutures. The excess mesh is then trimmed.
- Restorelle dual flat mesh: 2 pieces of 15 x 4 cm mesh
- One mesh arm is introduced into the pelvis through one of the ports.
- The arm is fixed to the anterior or posterior vaginal wall using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The second mesh arm is then introduced into the pelvis through one of the ports.
- The arm is fixed to either the anterior or posterior vaginal wall, depending on where the first arm was placed, using 5 delayed- absorbable (PDS) No. 2-0 sutures in an interrupted fashion, 1 to 2 cm apart from each other.
- The two arms are then brought to the sacral promontory and sutured together to the anterior longitudinal ligament using 2 permanent (prolene) No. 0 sutures. The excess mesh is then trimmed.
The peritoneum is then closed over the exposed graft with absorbable suture. Routine cystoscopy will also be performed in order to assess for lower urinary tract injury. A vaginal exam is performed, and an anterior and/or posterior colporrhaphy and perineorrhaphy are performed if needed. Anti-incontinence procedures may also be performed if needed.
**In laparoscopic cases, all suturing will be done extracorporeally while intracorporeal knot-tying technique will be performed in robot assisted laparoscopic cases.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Cololast, Inc. Restorell Y mesh | Active comparator | Device: Y meshY mesh |
| Coloplast, Inc. Restorelle Dual flat mesh | Active comparator | Device: Dual flat meshDual flat mesh |
Who may qualify
- Ages
- 18 to 100 years
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Age ≥ 18, who are to undergo laparoscopic or robotic laparoscopic sacrocolpopexy for pelvic organ prolapse
- Other concomitant laparoscopic or prolapse and anti-incontinence procedures (e.g., laparoscopic supracervical hysterectomy, cystocele repair, rectocele repair or mid-urethral sling procedures) will be performed at the primary surgeon's discretion.
Key exclusion criteria (5 listed)
- Inability to comprehend written and/or spoken English
- Inability to provide informed consent
- Medical illness precluding laparoscopy
- Need for concomitant surgeries not related to pelvic organ prolapse or incontinence
- Sacrocolpoperineopexy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Y meshAlso: Cololast, Inc. Restorell Y meshY mesh | Device | Cololast, Inc. Restorell Y mesh |
| Dual flat meshAlso: Coloplast, Inc. Restorelle Dual flat meshDual flat mesh | Device | Coloplast, Inc. Restorelle Dual flat mesh |
Primary outcome
Total Suturing Time for Mesh Placement = Time From Insertion of Y Mesh or First Flat Mesh Arm Into Pelvis to Last Sacral Suture Placed
Time frame: one day intraoperative
Total OR Time = Operating Room Time of Entry and Exit
Time frame: one day intraoperative
6 secondary outcomes
Post-operative Mean Difference POPDI at 24 Months
Time frame: 24 months
Postoperative Mean Difference CRADI at 24 Months
Time frame: 24 months
Postoperative Mean Difference UDI at 24 Months
Time frame: 24 months
Postoperative Subjective Recurrence at 24 Months
Time frame: 24 months
Postoperative Objective Recurrence at 24 Months
Time frame: 24 months
Reported Mesh Erosion at 24 Months
Time frame: 24 months
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Nov 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Prolapse
Active, not recruitingObservational study
Return to Physical Activity After Retropublic Transvaginal Sling and Laparoscopic Sacrocolpopexy
Stress Urinary Incontinence, Pelvic Organ Prolapse
Not yet recruiting
Early Feasibility Study of NeoChord Transcatheter Mitral Repair System
Degenerative Mitral Regurgitation, Degenerative Mitral Regurgitation (MR) Due to Leaflet Prolapse
Active, not recruitingPhase 3
Effect and Safety of Flecainide and Metoprolol Versus Metoprolol Alone to Suppress Ventricular Arrhythmias in Arrhythmic Mitral Valve Prolapse
Mitral Valve Prolapse, Ventricular Arrhythmias and Cardiac Arrest
Active, not recruitingObservational study
i-Stitch for Bilateral Sacrospinous Ligament Fixation (SSLF)
Pelvic Organ Prolapse, Genital Prolapse
RecruitingObservational study
Blepharoptosis After Repeated Intravitreal Anti-VEGF Injections: A Prospective Study
Blepharoptosis, Age-Related Macular Degeneration
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Cecile Unger, M.D. principal investigator
The Cleveland Clinic
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Y mesh and Dual flat mesh in people with Prolapse, run by The Cleveland Clinic at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 24 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 29 Oct 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Total Suturing Time for Mesh Placement = Time From Insertion of Y Mesh or First Flat Mesh Arm Into Pelvis to Last Sacral Suture Placed (time frame: one day intraoperative). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Nov 2020.