Retrospective / Prospective Clinical Study of AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric Intraocular Lenses

A study testing AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL in people with Cataract and Presbyopia, run by Alcon Research.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to characterize the safety and effectiveness of the ACRYSOF IQ ReSTOR +2.5 diopter (D) Multifocal Toric Intraocular Lens (IOL) in subjects at least 3 months and no more than 14 months after IOL implantation. Read more about this study

Who is it for?
Ages 21 years and older
Conditions the study is for
Cataract, Presbyopia, Corneal Astigmatism
What is being tested?
AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
37 participants
Where
No sites listed yet
Study dates
21 Jul 2014to 22 Aug 2014
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Must sign an informed consent form and be willing to come in for a visit at least 3 months and not more than 14 months after IOL implantation with the AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL (Models SV25T2, SV25T3, SV25T4 and SV25T5);
  • Must be implanted with the correct lens based on preoperative corneal astigmatism as specified in the protocol;
  • Must complete a visit within 10 days after IOL implantation;
  • Successful capsular bag implantation with no surgical complications;
  • Other protocol-specified inclusion criteria may apply.

Who cannot join

  • IOL implanted prior to the AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL;
  • Ocular or intraocular infection or inflammation at the time of the preoperative visit;
  • Any ocular surgery or intraocular laser procedure at or prior to the surgical visit;
  • Any conditions affecting the cornea (eg. corneal dystrophy, severe dry eye) at the preoperative visit;
  • Retinal conditions (e.g. degenerative retinal conditions, history of retinal detachment, diabetic retinopathy) at the preoperative visit;
  • Known history of Type 1 or 2 diabetes for more than 5 years;
Show all 11Show fewer
  • Any ocular or systemic co-morbidity at the preoperative visit;
  • Pregnant at the preoperative visit or at the time of Postoperative Visit 2;
  • Preoperative corneal astigmatism ≤ 0.50 D;
  • Participation in another clinical study at the preoperative visit or at the time of the final study visit;
  • Other protocol-specified exclusion criteria may apply.

About this study

The purpose of this study is to characterize the safety and effectiveness of the ACRYSOF IQ ReSTOR +2.5 diopter (D) Multifocal Toric Intraocular Lens (IOL) in subjects at least 3 months and no more than 14 months after IOL implantation.

Read the detailed description

This is a retrospective and prospective clinical study comprised of a retrospective chart review for preoperative, surgical and early postoperative data, and a prospective postoperative visit conducted at least 3 months but not more than 14 months after IOL implantation.

Being tested
AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL
Keywords
Cataract, Intraocular lens, ACRYSOF IQ ReSTOR + 2.5 D Multifocal Toric IOL
Medical subject headings
Cataract, Presbyopia, Astigmatism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOLDevice

    Also called Model SV25T2, Model SV25T3, Model SV25T4, Model SV25T5

    Multifocal IOL with extended secondary focal point and astigmatism correction implanted for long-term use over the lifetime of the cataract patient

Study groups in NCT02176343
Study groupRoleWhat they receive
ReSTOR Toric +2.5ExperimentalAcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL previously implanted during cataract surgery
Receives: Device: AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean Percent Reduction in Cylinder

    Manifest refraction cylinder was measured monocularly (each eye separately) with best correction (phoropter or trial lenses) under photopic (well-lit) lighting conditions using a 100% contrast ETDRS chart at 4 meters (m) from the subject. Percent reduction in cylinder was calculated as the difference between the postoperative magnitude of manifest refractive cylinder and the preoperative magnitude of keratometric cylinder divided by the intended reduction in cylinder [defined as the difference between the intended (from toric calculator) magnitude of the postoperative manifest refractive cylinder and the preoperative keratometric cylinder], multiplied by 100%. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  2. Percentage of Subjects With Manifest Refraction Cylinder ≤ 0.50 D

    Manifest refraction cylinder was measured monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m from the subject. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  3. Percentage of Subjects (With Preoperative Astigmatism > 1.00 D) With Manifest Refraction Cylinder ≤ 1.00 D

    Manifest refraction cylinder was measured monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m from the subject. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  4. Mean Uncorrected Distance Visual Acuity

    Visual Acuity (VA) was tested monocularly without visual correction under photopic (well-lit) conditions using a 100% contrast ETDRS chart positioned 4 m from the subject. A +0.25 D spherical power additional lens was used to correct for optical infinity. VA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  5. Mean Uncorrected Near Visual Acuity

    VA was tested monocularly without visual correction under photopic lighting conditions using a 100% contrast near ETDRS chart set at 40 cm on the nearpoint rod of the phoropter. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  6. Mean Uncorrected Intermediate Visual Acuity

    VA was tested monocularly without visual correction under photopic lighting conditions using a 100% contrast near ETDRS chart set at 53 cm on the nearpoint rod of the phoropter. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  7. Mean Best Corrected Distance Visual Acuity (BCDVA)

    VA was tested monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m away from the subject. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

  8. Mean IOL Rotation

    Lens axis orientation (position of the lens within the capsular bag) as indicated by indentations on the IOL was assessed during slit lamp examination. IOL rotation (the difference between the achieved lens axis orientation at visit and achieved axis placement at surgery) was measured in degrees. One eye (primary eye) contributed to the analysis.

    Measured: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Jun 2014 (estimated)
  2. Study start21 Jul 2014
  3. Primary completion22 Aug 2014
  4. Study completion22 Aug 2014

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
37 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02176343
Sponsor's protocol ID
C-14-005
Status last verified
May 2017
First submitted
25 Jun 2014
Last updated
2 Jul 2018
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL in people with Cataract and Presbyopia, run by Alcon Research.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 2 Jul 2018. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 29 Jun 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean Percent Reduction in Cylinder (time frame: Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)). The study lists 8 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Jul 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in