BradycardiaPhase 4MRI-rePACENCT02195024
Cardiac MRI After Pacemaker Replacement
A Phase 4 study testing cardiac MRI group in people with Bradycardia and Cardiac Pacemaker, run by Dr. Dirk Bastian at 1 site in Germany.
Trial summary
Aim of this trial is to investigate feasibility of cardiac magnetic resonance imaging (cMRI) in patients with long term implanted coradial leads upgraded to an MRI conditional pacemaker system, to assess MR-image quality and to prove the safety of MRI in this specific population in the short term as well as during… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Bradycardia, Cardiac Pacemaker, Magnetic Resonance Imaging
- What is being tested?
- cardiac MRI group
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 23 participants
- Where
- 1 siteGermany
- Study dates
- Jul 2014to May 2017
- Phase
- Phase 4
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Approved clinical indication for pectoral pacemaker exchange (e.g. elective replacement indication (ERI), end of service (EOS))
- Implantation of a CE certified / market released MRI conditional pacemaker (BSCI) consistent of
- a single or dual chamber MRI conditional pacemaker (BSCI) or
- Any comparable successor IPG (MRI conditional system, BSCI) compatible with
- Implanted Fineline-II-leads (BSCI), MRI conditional
- Leads electrically intact and with stable and normal function
Show all 18Show fewer
- The ascertained lead impedance is between 200 and 1500 Ohm.
- All pacing capture thresholds (PCT) do not exceed 2.0 V @0.4 or 0.5 ms in pacemaker dependent patients
- Adherence to the MRI conditions of use is given
- Male or female 18 years or older
- Understand the nature of the procedure
- Give written informed consent
- Able to complete all testing required by the clinical protocol
- Ability to measure atrial and/or ventricular pacing threshold(s) at 0.4 or 0.5 ms
- Patient body height greater or equal to 140 cm
- Pectoral implanted device
- Subjects who are able and willing to undergo elective cardiac magnetic resonance (MR) scanning without sedation (MRI-group)
- Subjects who are geographically stable and available for follow-up at the study center for the length of the study
Who cannot join
- • Non MRI conditional leads implanted
- Pacing threshold(s) (at 0.4 or 0.5 ms) and/or sensing amplitude(s) and/or impedance(s) are not measurable
- Meet one or more of the contraindications for MRI including Psychiatric disorders, anxiety, claustrophobia Cardiac disorders that represent a contraindication to MRI
- Cardiac surgery already scheduled in the next three months
- Have other medical implants that may interact with MRI, e.g. abandoned implantable cardioverter defibrillator (ICD) leads or pacemaker leads other than MRI conditional, lead extensions, other active medical devices, non-MRI compatible devices, mechanical valve
- Have other metallic artifacts/components in body that may interact with MRI
Show all 14Show fewer
- Subjects for whom a single dose of 1.0 milligram (mg) dexamethasone acetate may be contraindicated
- Subjects who require a legally authorized representative to obtain consent
- Subjects who are immediate candidates for an ICD
- Subjects with medical conditions that preclude the testing required by the protocol or limit study participation
- Subjects who are enrolled or intend to participate in another clinical trial (of an investigational drug or device, new indication for an approved drug or device, or requirement of additional testing beyond standard clinical practice) during this clinical study
- Being pregnant
- Have a life expectancy of less than three months
- Subjects with exclusion criteria required by local law (e.g. age, breastfeeding)
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Cardiac MRI After Replacement of Long Term Implanted PACEmakers by a MRI Conditional Pulse Generator (MRI-rePace)
Aim of this trial is to investigate feasibility of cardiac magnetic resonance imaging (cMRI) in patients with long term implanted coradial leads upgraded to an MRI conditional pacemaker system, to assess MR-image quality and to prove the safety of MRI in this specific population in the short term as well as during long term follow-up.
Read the detailed description
The trial is designed
- To investigate the cardiac MRI related adverse event-free rate in patients with long term implanted coradial pacing leads (Fineline-II) after implantable pulse generator (IPG) exchange to a MRI conditional system (short term and long term): Safety.
- To assess the technical performance of MRI conditional pacemaker systems with long term implanted coradial pacing leads, for cardiac MRI (short term and long term): Effectiveness pacemaker.
- To assess the image quality (IQ) and the diagnostic value (DV) of the cardiac MRI scans in patients with implanted MRI conditional systems: Effectiveness cardiac MRI.
- To evaluate the clinical incidence of MRI procedures in the population of long term implanted pacemaker patients (long term-follow up)
- Conditions
- Bradycardia, Cardiac Pacemaker, Magnetic Resonance Imaging
- Being tested
- cardiac MRI group
- Keywords
- pacemaker, magnetic resonance imaging, MRI conditional, pacemaker leads
- Medical subject headings
- Bradycardia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
cardiac MRI groupProcedure or surgery
- All subjects of the MRI group will undergo a predefined series of magnetic resonance heart scans ≥ six (6) weeks after device exchange
| Study group | Role | What they receive |
|---|---|---|
| cardiac MRI group | Active comparator | • All subjects of the MRI group will undergo a predefined series of magnetic resonance heart scans ≥ six (6) weeks after device exchange Receives: Procedure: cardiac MRI group |
| No MRI group | No intervention | Patients that refuse to undergo cMRI for any reason but accept to attend the trial can be further observed according to the protocol |
What is being measured
The primary outcome is the main question the study is designed to answer.
safety: cardiac MRI and pacing system related Serious Adverse Device Effects
Primary outcome measure 1 (safety):
- cMRI and pacing system related Serious Adverse Device Effect (SADE) free rate after 3 months.
- Hypothesis: MRI and pacing system related Serious Adverse Device Effect (SADE) free-Rate is greater than 90% after 3 months.
Measured: 3 months after cardiac MRI
Effectiveness cardiac MRI: cMRI image quality (IQ) and diagnostic value (DV)
Primary outcome measure 2 (Effectiveness cardiac MRI):
- cMRI image quality (IQ) and diagnostic value (DV)
- Hypothesis: cMRI IQ is "acceptable" and clinical use is not adversely affected in ≥ 90% cMRI procedures
Measured: cMRI images done ≥ six (6) weeks after device exchange
Secondary outcomes (7)
cMRI and pacing system related Adverse Device Effect
The proportion of patients with a cMRI and pacing system related Adverse Device Effect (ADE)
Measured: 1 and 3 months after cardiac MRI
Pacemaker performance under/after MRI (short and midterm) - Pacing capture threshold (PCT) rise (atrial and ventricular)
- The proportion of patients with an atrial or ventricular MRI induced pacing capture threshold rise larger than or equal to 100% voltage safety margin of the measured Pre-MRI pacing threshold at post-MRI interrogation, at 1-month and at 3 month follow- up
- The proportion of patients with an atrial or ventricular MRI induced pacing threshold rise larger than or equal to 1.0 V @ 0.4 ms or 0.5 ms between pre-MRI and at post-MRI interrogation, 1 month and at 3-month follow-up
Measured: 1 and 3 Months after cardiac MRI
Pacemaker performance under/after MRI (short and midterm): atrial or ventricular sensing amplitude
- P and R-wave sensing attenuation:
- The proportion of patients with an atrial or ventricular amplitude decrease that exceed 50% between Pre-MRI evaluation and at post-MRI interrogation, at 1-month and at 3-month follow-up
Measured: between Pre-MRI evaluation and at post-MRI interrogation at 1-month and at 3-month follow-up after cMRI
- Long term pacing capture threshold rise (atrial and ventricular)
- The proportion of patients with an atrial or ventricular MRI induced pacing capture threshold rise larger than or equal to 100% voltage safety margin of the measured Pre-MRI pacing threshold between Pre-MRI interrogation and at 2 years follow- up
- The proportion of patients with an atrial or ventricular MRI induced pacing capture threshold rise larger than or equal to 1.0 V @ 0.4 ms or 0.5 ms between Pre-MRI interrogation and at 2 years follow- up
Measured: Pre-MRI interrogation and at 2 years follow- up
- Long term P and R-wave sensing attenuation
The proportion of patients with an atrial or ventricular amplitude decrease that exceed 50% between Pre-MRI interrogation and 2 years follow-up
Measured: between Pre-MRI interrogation and 2 years follow-up
MRI procedures during long term-follow up
Clinical incidence of MRI procedures during long term-follow up, device performance after repetitive MRI procedures
Measured: during a minimum of 2 years follow-up
periprocedural cardiac troponin
Cardiac high sensitive Troponin pre- and post-MRI as marker of thermal injury
Measured: pre- and within 3 to 24 hours post-MRI
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Jul 2014 (estimated)
- Study startJul 2014
- Primary completionMay 2017
- Study completionMay 2017
Why it stopped: PI changed affiliation not beening allowed to continue the trial in further cooperation. The sub-investigators did not see any option to continue the trial and made the decision to terminate the study.
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for BradycardiaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 23 participants (actual)
Sponsor and investigators
- Lead sponsor
- Dr. Dirk Bastian
- Sponsor type
- University, hospital or other
- Collaborators
- Boston Scientific Corporation
- Responsible party
- Sponsor-investigator, Dr. Dirk Bastian, Paracelsus Medical University
- Investigators
- Dirk Bastian, MD, Principal investigator, Paracelsus Medical University Nürnberg
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02195024
- Sponsor's protocol ID
- PMUN-DB-001-MRIPM
- Acronym
- MRI-rePACE
- Status last verified
- Jan 2021
- First submitted
- 17 Jul 2014
- Last updated
- 12 Jan 2021
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 12 Jan 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Cardiac MRI After Replacement of Long Term Implanted PACEmakers by a MRI Conditional Pulse Generator (MRI-rePace)
- ClinicalTrials.gov ID
- NCT02195024
- Acronym / sponsor ID
- MRI-rePACE / PMUN-DB-001-MRIPM
- Conditions
- Bradycardia, Cardiac Pacemaker, Magnetic Resonance Imaging
- Keywords
- pacemaker, magnetic resonance imaging, MRI conditional, pacemaker leads
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- TerminatedReason stopped: PI changed affiliation not beening allowed to continue the trial in further cooperation. The sub-investigators did not see any option to continue the trial and made the decision to terminate the study.
- Enrolment
- 23 participants (actual)
- Lead sponsor
- Dr. Dirk BastianUniversity, hospital or other
- Collaborators
- Boston Scientific Corporation
- Study start
- Jul 2014
- Primary completion
- May 2017 (actual)
- Study completion
- May 2017 (actual)
- First posted
- 21 Jul 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Aim of this trial is to investigate feasibility of cardiac magnetic resonance imaging (cMRI) in patients with long term implanted coradial leads upgraded to an MRI conditional pacemaker system, to assess MR-image quality and to prove the safety of MRI in this specific population in the short term as well as during long term follow-up.
Detailed description
The trial is designed
- To investigate the cardiac MRI related adverse event-free rate in patients with long term implanted coradial pacing leads (Fineline-II) after implantable pulse generator (IPG) exchange to a MRI conditional system (short term and long term): Safety.
- To assess the technical performance of MRI conditional pacemaker systems with long term implanted coradial pacing leads, for cardiac MRI (short term and long term): Effectiveness pacemaker.
- To assess the image quality (IQ) and the diagnostic value (DV) of the cardiac MRI scans in patients with implanted MRI conditional systems: Effectiveness cardiac MRI.
- To evaluate the clinical incidence of MRI procedures in the population of long term implanted pacemaker patients (long term-follow up)
Study design
- Primary purpose
- Diagnosis
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| cardiac MRI group | Active comparator | Procedure: cardiac MRI group• All subjects of the MRI group will undergo a predefined series of magnetic resonance heart scans ≥ six (6) weeks after device exchange |
| No MRI group | No intervention | –Patients that refuse to undergo cMRI for any reason but accept to attend the trial can be further observed according to the protocol |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (18 listed)
- Approved clinical indication for pectoral pacemaker exchange (e.g. elective replacement indication (ERI), end of service (EOS))
- Implantation of a CE certified / market released MRI conditional pacemaker (BSCI) consistent of
- Implanted Fineline-II-leads (BSCI), MRI conditional
- Leads electrically intact and with stable and normal function
- Adherence to the MRI conditions of use is given
Key exclusion criteria (14 listed)
- • Non MRI conditional leads implanted
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| cardiac MRI group• All subjects of the MRI group will undergo a predefined series of magnetic resonance heart scans ≥ six (6) weeks after device exchange | Procedure or surgery | cardiac MRI group |
Primary outcome
safety: cardiac MRI and pacing system related Serious Adverse Device Effects
Time frame: 3 months after cardiac MRI
Primary outcome measure 1 (safety): * cMRI and pacing system related Serious Adverse Device Effect (SADE) free rate after 3 months. * Hypothesis: MRI and pacing system related Serious Adverse Device Effect (SADE) free-Rate is greater than 90% after 3 months.
Effectiveness cardiac MRI: cMRI image quality (IQ) and diagnostic value (DV)
Time frame: cMRI images done ≥ six (6) weeks after device exchange
Primary outcome measure 2 (Effectiveness cardiac MRI): * cMRI image quality (IQ) and diagnostic value (DV) * Hypothesis: cMRI IQ is "acceptable" and clinical use is not adversely affected in ≥ 90% cMRI procedures
7 secondary outcomes
cMRI and pacing system related Adverse Device Effect
Time frame: 1 and 3 months after cardiac MRI
Pacemaker performance under/after MRI (short and midterm) - Pacing capture threshold (PCT) rise (atrial and ventricular)
Time frame: 1 and 3 Months after cardiac MRI
Pacemaker performance under/after MRI (short and midterm): atrial or ventricular sensing amplitude
Time frame: between Pre-MRI evaluation and at post-MRI interrogation at 1-month and at 3-month follow-up after cMRI
- Long term pacing capture threshold rise (atrial and ventricular)
Time frame: Pre-MRI interrogation and at 2 years follow- up
- Long term P and R-wave sensing attenuation
Time frame: between Pre-MRI interrogation and 2 years follow-up
MRI procedures during long term-follow up
Time frame: during a minimum of 2 years follow-up
periprocedural cardiac troponin
Time frame: pre- and within 3 to 24 hours post-MRI
Results and safety
The study was stopped early (reason given: PI changed affiliation not beening allowed to continue the trial in further cooperation. The sub-investigators did not see any option to continue the trial and made the decision to terminate the study.). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 12 Jan 2021.
Related trials for Bradycardia
Active, not recruitingObservational study
Safety, Performance, and Clinical Benefit of Pacing the Left Bundle Branch Area - Post-Market Clinical Follow-up
Bradycardia, Atrioventricular Block
RecruitingObservational study
BIO|STREAM.CSP Study
Cardiac Pacing, Cardiac Pacemaker
Active, not recruiting
BIO|MASTER.CSP Study
Cardiac Pacing, Artificial, Cardiac Pacemaker, Artificial
Recruiting
SPIKE FLOW Endocardial Lead Safety and Performance Study
Acute Myocardial Infarction (AMI), Asystole
Not yet recruiting
Head-to-Head (H2H) Comparison of Ambulatory Cardiac ECG Monitors in Japan
Atrial Fibrillation (AF), Atrial Flutter
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dirk Bastian, MD principal investigator
Paracelsus Medical University Nürnberg
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing cardiac MRI group in people with Bradycardia and Cardiac Pacemaker, run by Dr. Dirk Bastian at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 18 inclusion and 14 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 12 Jan 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study was stopped early (reason given: PI changed affiliation not beening allowed to continue the trial in further cooperation. The sub-investigators did not see any option to continue the trial and made the decision to terminate the study.). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
safety: cardiac MRI and pacing system related Serious Adverse Device Effects (time frame: 3 months after cardiac MRI). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Jan 2021.