Complete Mandibular Dentures With Poor RetentionNCT02203279

Evaluation of Three Hard Relining Materials in Complete Dentures

A study testing Rebase II Fast, Flexacryl and Vertex in people with Complete Mandibular Dentures With Poor Retention, run by Damascus University at 1 site in Syria.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Purpose: The purpose of this study is to evaluate three hard relining materials after 3 and 6 months of use with mandibular complete dentures. The effect of hard relining materials on supporting tissues and patients' satisfaction will also be assessed. Read more about this study

Who is it for?
Ages 47 to 78 years, men only
What is being tested?
Rebase II Fast, Flexacryl and Vertex
Could I receive a placebo?
No, everyone receives an active treatment
How many people
36 participants
Where
1 siteSyria
Study dates
Jul 2014to Sep 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 47 to 78 years
  • Men only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age between 45-80 year,
  • complete maxillary and lower dentures
  • Mandibular dentures with poor retention

Who cannot join

  • Patients with good stability of mandibular dentures.
  • Partial maxillary edentulous patients

Trial locations and contacts

1 site in 1 country.

Syria1 site
  • Department of Removable Prosthodontics, University of Damascus Dental School

    Damascus, Rif-dimashq Governorate, DM20AM18

Other trials in Syria

About this study

Official title: Evaluation of Three Hard Relining Materials in Complete Dentures: An In-vivo Study

Purpose: The purpose of this study is to evaluate three hard relining materials after 3 and 6 months of use with mandibular complete dentures. The effect of hard relining materials on supporting tissues and patients' satisfaction will also be assessed.

Materials and Methods: 36 complete edentulous patients who already have maxillary dentures and complaining of instable mandibular dentures will be invited to participate in this study. Mandibular dentures will be relined randomly by one of three relining materials: two chairside relining materials (Tokuyama Rebase II Fast, Tokuyama Dental Co, Japan), and (Flexacryl Hard, Lang Co, USA) and one heat cured acrylic resin (Vertex, Dental technology Co, Holland).

The color stability of relining material, peeling, and the effect on supporting tissue will be assessed by two separate prosthodontists after 3 and 6 months of follow up. In addition, patients will be asked to grade there overall satisfaction on a Visual Analogue Scale (VAS) ranging from 0 to 100.

Read the detailed description

Relining denture is a process of resurfacing the tissue side of a denture to make it fit more accurately Direct relining of removable dentures with hard chair-side reline materials is suitable for improving the fit of the denture bases to the supporting tissues. Chairside reline materials are more convenient than those processed in a laboratory because the direct method is faster and does not cause clinically significant dimensional changes of the reline resin. However, when autopolymerized reline resins are used with a direct method, several problems can occur as burning sensation caused by monomers, an exothermic heat reaction and an unpleasant odor.

There are three types of hard relining chair-side materials: Dual-polymerized Visible light-polymerized as Triad DuaLine, Light Liner (Hard), Astron LC (Hard).Visible light-polymerized as Lightdon-U, Triad Hi-Flow Reline Material, Triad VLC Reline Material. Finally, autopolymerized as New Truline, Tokuyama Rebase II (Fast) , GC Reline. Other concerns related to direct reline materials include patient tolerance (taste, temperature, odor), color stability, durability and ease of handling and polishing.

Few studies evaluated the effect of disinfection solutions on relining materials properties as roughness and hardness. In one study, disinfectant solutions caused a decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Depending on the examined relining materials, some materials have increased and the others have decreased surface roughness after immersion in disinfecting solutions or microwave disinfection.

All previous laboratory studies concentrated on the effects of disinfection on relining materials properties as roughness, hardness, color change. However, the clinical studies did not compare chemically cured and heat cured relining materials and their effects on supporting tissue. The aim of this study is to evaluate the clinical performance of two -chemically cured- and heat cured denture relining material after 3 and 6 months of use. In addition, the effect of hard relining materials on supporting tissues, and patients' satisfaction has not been evaluated yet.

Being tested
Rebase II Fast, Flexacryl, Vertex
Keywords
Chair-side hard relining, complete denture, patients' satisfaction, supporting tissues, autopolymerized reline resins, heat cured relining material

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Rebase II FastOther

    It is going to be used a direct relining material

  • FlexacrylOther

    This is going to be used as a second direct relining material

  • VertexOther

    This is going to be used as an indirect relining material

Study groups in NCT02203279
Study groupRoleWhat they receive
Rebase II FastExperimentalThe direct chair-side relining materiel 'Rebase II Fast' will be used.
Receives: Other: Rebase II Fast
FlexacrylExperimentalThe direct chair-side relining material Flexacryl will be used
Receives: Other: Flexacryl
VertexExperimentalVertex is a heat-cured resin material which is going to be used for indirect relining
Receives: Other: Vertex

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Supporting Alveolar Mucosa Status_3

    According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:

    Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.

    Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.

    Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.

    Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.

    Measured: This will be measured at three months following relining

  2. Supporting Alveolar Mucosa Status_6

    According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:

    Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.

    Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.

    Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.

    Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.

    Measured: This variable will be assessed at six months following relining

  3. Color Stability_3

    The color stability variable has four degrees on clinical examination:

    1. no change
    2. simple
    3. medium
    4. large

    Measured: This will be assessed at three moths following relining

Secondary outcomes (5)
  1. Color Stability_6

    The color stability variable has four degrees on clinical examination:

    no change simple medium large

    Measured: This be assessed at six months following relining

  2. Peeling_3

    This variable is going to be inspected clinically and it has two categories:

    1. peeling more than 4 mm
    2. peeling less than 4 mm

    Measured: This variable is going to be assessed at three months following relining

  3. Peeling_6

    This variable is going to be inspected clinically and it has two categories:

    1. peeling more than 4 mm
    2. peeling less than 4 mm

    Measured: This variable is going to be assessed at six months following relining

  4. Satisfaction_3

    Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.

    Measured: This is going to be measured at three months following relining

  5. Satisfaction_6

    Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.

    Measured: This is going to be measured at six months following relining

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Jul 2014 (estimated)
  2. Study startJul 2014
  3. Primary completionAug 2015
  4. Study completionSep 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
36 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02203279
Sponsor's protocol ID
UDDS-RemPro-02-2014
Status last verified
Sep 2015
First submitted
28 Jul 2014
Last updated
29 Sep 2015
Results posted
No
Data monitoring committee
Yes

Publications

  • Al Rifaiy MQ. Shear bond strength between light polymerized hard reline resin and denture base resin subjected to long term water immersion. Saudi Dent J. 2012 Jan;24(1):23-7. doi: 10.1016/j.sdentj.2011.10.004. Epub 2011 Nov 20.

    PubMed 23960524
  • Arima T, Murata H, Hamada T. Analysis of composition and structure of hard autopolymerizing reline resins. J Oral Rehabil. 1996 May;23(5):346-52. doi: 10.1111/j.1365-2842.1996.tb00863.x.

    PubMed 8736448
  • Pinto Lde R, Acosta EJ, Tavora FF, da Silva PM, Porto VC. Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins. Gerodontology. 2010 Jun;27(2):147-53. doi: 10.1111/j.1741-2358.2009.00282.x. Epub 2009 Jun 8.

    PubMed 19508322
  • Haywood J, Basker RM, Watson CJ, Wood DJ. A comparison of three hard chairside denture reline materials. Part I. Clinical evaluation. Eur J Prosthodont Restor Dent. 2003 Dec;11(4):157-63.

    PubMed 14737792
  • Hong G, Murata H, Li Y, Sadamori S, Hamada T. Influence of denture cleansers on the color stability of three types of denture base acrylic resin. J Prosthet Dent. 2009 Mar;101(3):205-13. doi: 10.1016/S0022-3913(09)60032-9.

    PubMed 19231574
  • Machado AL, Breeding LC, Vergani CE, da Cruz Perez LE. Hardness and surface roughness of reline and denture base acrylic resins after repeated disinfection procedures. J Prosthet Dent. 2009 Aug;102(2):115-22. doi: 10.1016/S0022-3913(09)60120-7.

    PubMed 19643225
  • Machado AL, Giampaolo ET, Vergani CE, Souza JF, Jorge JH. Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials. J Appl Oral Sci. 2011 Oct;19(5):521-8. doi: 10.1590/s1678-77572011000500015.

    PubMed 21986658
  • Matsumura H, Tanoue N, Kawasaki K, Atsuta M. Clinical evaluation of a chemically cured hard denture relining material. J Oral Rehabil. 2001 Jul;28(7):640-4. doi: 10.1046/j.1365-2842.2001.00701.x.

    PubMed 11422696
  • Murata H, Seo RS, Hamada T, Polyzois GL, Frangou MJ. Dynamic mechanical properties of hard, direct denture reline resins. J Prosthet Dent. 2007 Oct;98(4):319-26. doi: 10.1016/S0022-3913(07)60105-X.

    PubMed 17936130
  • Ogle RE, Sorensen SE, Lewis EA. A new visible light-cured resin system applied to removable prosthodontics. J Prosthet Dent. 1986 Oct;56(4):497-506. doi: 10.1016/0022-3913(86)90397-5.

    PubMed 3463760
  • Wyatt CC, Harrop TJ, MacEntee MI. A comparison of physical characteristics of six hard denture reline materials. J Prosthet Dent. 1986 Mar;55(3):343-6. doi: 10.1016/0022-3913(86)90117-4.

    PubMed 3457166

Questions about this trial

What is this clinical trial studying?

A study testing Rebase II Fast, Flexacryl and Vertex in people with Complete Mandibular Dentures With Poor Retention, run by Damascus University at 1 site in Syria.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Sep 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Syria. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Supporting Alveolar Mucosa Status_3 (time frame: This will be measured at three months following relining). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02203279, which also lists 11 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.