AzTrials
AzTrials

Persistent Atrial FibrillationNCT02217657

SmartTouch Catheter for Left Anterior Line - SmarT Line Study

A study testing Thermocool Smart Touch Catheter in people with Persistent Atrial Fibrillation, run by LMU Klinikum at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This prospective, randomized study will investigate, if information of the catheter force during ablation of a left anterior line does reduce total RF application time by prevention of ineffective lesions. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Persistent Atrial Fibrillation
What is being tested?
Thermocool Smart Touch Catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
75 participants
Where
1 siteGermany
Study dates
Aug 2013to Dec 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with symptomatic atrial fibrillation and additional substrate modification or perimitral flutter
  • Patients with persistent atrial fibrillation
  • Patients with perimitral flutter
  • Patients with recurrence after a circumferential PV isolation procedure
  • Patients with paroxysmal atrial fibrillation and AF episodes lasting > 7 days
  • Patients (>18 und <80 Jahre)

Who cannot join

  • moderate to severe valvular heart disease,
  • congenital heart disease
  • reduced left ventricular function (ejection fraction <35%)
  • any reversible cause for atrial fibrillation (e.g. hyperthyroidism)
  • intracardiac thrombi documented by transesophageal echocardiography
  • myocardial infarction within 3 months, cardiac surgery in the previous three months

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Munich University Clinic, Campus Großhadern

    Munich, Bavaria, 81377

Other trials in Germany

About this study

Official title: "Bidirectional Conduction Block of Left Atrial Anterior Line in Patients With Left Atrial Ablation - Reduction of RF Applications Using the Thermocool SmartTouch Contact Force Sensing Catheter

This prospective, randomized study will investigate, if information of the catheter force during ablation of a left anterior line does reduce total RF application time by prevention of ineffective lesions.

Read the detailed description

Catheter ablation has emerged as a realistic therapeutic option for symptomatic atrial fibrillation (AF).

The three main techniques described for ablation of persistent AF include pulmonary vein (PV) isolation, ablation based on electrogram analysis, and left atrial (LA) linear lesions.

The ideal endpoint of linear lesions should be complete electrical block; however, this is technically challenging, time consuming, and potentially hazardous. The ST catheter combined with 3D mapping and navigation software, gives physicians a real-time, objective measure of tip-to-tissue contact force during the catheter ablation procedure and will allow physicians to more safely and effectively treat atrial fibrillation.

Being tested
Thermocool Smart Touch Catheter
Keywords
Smart-Touch, Contact force
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Thermocool Smart Touch CatheterDevice

    Physician informed to contact force

Study groups in NCT02217657
Study groupRoleWhat they receive
operator informed to contact forceActive comparatorThermocool Smart Touch Catheter, operator informed to contact force (Biosense Webster)
Receives: Device: Thermocool Smart Touch Catheter
operator blinded to contact forceExperimentalThermocool Smart Touch catheter, operator blinded to contact force information (Biosense Webster)
Receives: Device: Thermocool Smart Touch Catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Duration of total RF application until bidirectional conduction block across the anterior line is achieved (including a waiting period of 30 minutes)

    Measured: 30 minutes

Secondary outcomes (1)
  1. Achievement of primary endpoint (bidirectional conduction block at an anterior line)

    Achievement of primary endpoint (bidirectional conduction block at an anterior line). Procedure Duration. Reduction of local potential amplitude during SR or atrial fibrillation after 60 seconds of ablation. Freedom of any atrial tachyarrhythmia at 7 day holter 3 and 6 months after a single ablation procedure. Freedom of any symptoms of atrial arrhythmias 6 months after ablation (except during blanking period of 6 weeks). Confirmation of gap-freeness in MRI (3-6 months after ablation). Quality of Life (atrial fibrillation symptom checklist und major depression index) pre, 3 and 6 months after Ablation. Safety (bleeding, pericardial effusion, thrombembolic events).

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Aug 2014 (estimated)
  2. Study startAug 2013
  3. Primary completionDec 2016
  4. Study completionDec 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
75 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02217657
Sponsor's protocol ID
MucM001-13
Status last verified
Feb 2021
First submitted
14 Aug 2014
Last updated
25 Feb 2021
Results posted
No
Data monitoring committee
No
Individual data sharing
No

Publications

  • Fichtner S, Wakili R, Rizas K, Siebermair J, Sinner MF, Wiktor T, Lackermair K, Schuessler F, Olesch L, Rainer S, Kaab S, Curta A, Kramer H, Estner HL. Benefit of Contact Force Sensing Catheter Technology for Successful Left Atrial Anterior Line Formation: A Prospective Randomized Trial. Biomed Res Int. 2018 Sep 18;2018:9784259. doi: 10.1155/2018/9784259. eCollection 2018.

    PubMed 30320138

Questions about this trial

What is this clinical trial studying?

A study testing Thermocool Smart Touch Catheter in people with Persistent Atrial Fibrillation, run by LMU Klinikum at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 Feb 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Duration of total RF application until bidirectional conduction block across the anterior line is achieved (including a waiting period of 30 minutes) (time frame: 30 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02217657, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Feb 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in