Trial summary

The purpose of this study is to compare an investigational contact lens care product (FID 109182) to a commercially available contact lens product (Opti-Free Plus®) for corneal staining when used with Acuvue® Oasys® contact lenses. Read more about this study

Who is it for?
Ages 20 years and older
Conditions the study is for
Corneal Staining
What is being tested?
FID 109182, Opti-Free Plus and Senofilcon A contact lens
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
36 participants
Where
No sites listed yet
Study dates
Nov 2013to May 2014
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Soft contact lenses habitual wearer, both eyes.
  • Voluntarily sign Informed Consent.
  • Other protocol-defined inclusion criteria may apply.

Who cannot join

  • Unable to tolerate the ingredients in Opti-Free® and similar contact lens care products.
  • Potential use of eye drops during the study, including over-the-counter products, except for artificial tear eye drops.
  • Eye infection, blepharitis, iris inflammation, or severe eye inflammation.
  • Corneal staining greater than Grade 1 at baseline.
  • Pregnant, lactating, or intend to become pregnant during study period.
  • Other protocol-defined exclusion criteria may apply.

About this study

Official title: Clinical Evaluation of Opti-Free III Compared to Opti-Free Plus®

The purpose of this study is to compare an investigational contact lens care product (FID 109182) to a commercially available contact lens product (Opti-Free Plus®) for corneal staining when used with Acuvue® Oasys® contact lenses. The contact lenses will be pre-soaked in the products for 24-48 hours prior to a 2-hour contralateral wear period.

Being tested
FID 109182, Opti-Free Plus, Senofilcon A contact lens
Keywords
contact lenses, contact lens solution, corneal staining, fluorescein

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • FID 109182Device

    Also called Opti-Free III

    Investigational multipurpose contact lens cleaning and disinfecting solution

  • Opti-Free PlusDevice

    Also called Opti-Free Plus®

    Commercially available multipurpose contact lens cleaning and disinfecting solution

  • Senofilcon A contact lensDevice

    Also called Acuvue® Oasys®

    Commercially available silicone hydrogel contact lens

Study groups in NCT02251561
Study groupRoleWhat they receive
FID 109182ExperimentalSenofilcon A contact lens pre-soaked in FID 109182 worn in the right or left eye as randomized for 2 hours
Receives: Device: FID 109182; Device: Senofilcon A contact lens
Opti-Free PlusActive comparatorSenofilcon A contact lens pre-soaked in Opti-Free Plus worn in the fellow eye for 2 hours
Receives: Device: Opti-Free Plus; Device: Senofilcon A contact lens

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Proportion of Participants Scoring ≥ 2 for Corneal Staining Density With Fluorescein

    The contact lens was removed, the cornea was stained with fluorescein (ophthalmic dye), and pictures of the corneal surface were taken. Corneal staining density was evaluated for each eye individually against representative pictures and scored on a 0-3 scale (0=No staining; 1=Staining with low density; 2=Staining with moderate density; 3=Staining with severe density). Proportion of participants is reported as a percentage.

    Measured: Day 1, after 2 hours of wear

Secondary outcomes (1)
  1. Proportion of Participants Scoring ≥ 2 for Corneal Staining Area With Fluorescein

    The contact lens was removed, the cornea was stained with fluorescein (ophthalmic dye), and pictures of the corneal surface were taken. Corneal staining area was evaluated for each eye individually against representative pictures and scored on a 0-3 scale [0=No staining; 1=Staining with small area (1 to 25% of corneal surface); 2=Staining with medium area (26 to 50% of corneal surface); 3=Staining with large area (51% of corneal surface or greater)]. Proportion of participants is reported as a percentage.

    Measured: Day 1, after 2 hours of wear

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Sep 2014 (estimated)
  2. Study startNov 2013
  3. Primary completionMay 2014
  4. Study completionMay 2014

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Allocation
Randomised
Intervention model
Single group
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
36 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02251561
Sponsor's protocol ID
CVKK2013-01
Status last verified
Jun 2015
First submitted
25 Sep 2014
Last updated
10 Jun 2015
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing FID 109182, Opti-Free Plus and Senofilcon A contact lens in people with Corneal Staining, run by Alcon Research.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Jun 2015. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 10 Jun 2015). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Proportion of Participants Scoring ≥ 2 for Corneal Staining Density With Fluorescein (time frame: Day 1, after 2 hours of wear). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Jun 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in