Aneurysm of Aortic ArchNCT02264977

Early Feasibility of the Branched TAG® Device in the Treatment of Aortic Arch Aneurysms

A study testing GORE® TAG® Thoracic Branch Endoprosthesis in people with Aneurysm of Aortic Arch, run by W.L.Gore & Associates at 6 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

The purpose of this study is to assess the early feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the aortic arch Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aneurysm of Aortic Arch
What is being tested?
GORE® TAG® Thoracic Branch Endoprosthesis
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
9 participants
Where
6 sitesUnited States
Study dates
Apr 2015to Mar 2022
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Presence of aortic aneurysm involving the aortic arch deemed to warrant surgical repair which requires proximal graft placement in Zone 0 or Zone 1:
  • Fusiform (≥ 55 mm), or
  • Fusiform (>2 times native aortic diameter), or
  • Saccular (no diameter criteria)
  • Subject is considered a high risk candidate for conventional open surgical repair at the discretion of the Investigator
  • Age ≥18 years at time of informed consent signature
Show all 22Show fewer
  • Subject is capable of complying with protocol requirements, including follow-up
  • Informed Consent Form (ICF) is signed by Subject or legal representative
  • Must have appropriate proximal aortic landing zone, defined as:
  • Must require placement of the proximal extent of the Aortic Component in Zone 0 or Zone 1 for exclusion of the lesion
  • Acceptable proximal landing zone outer curvature length for the required device
  • Landing zone inner diameters between 16-48 mm in Zone 1 Subjects and 24-48mm in Zone 0 Subjects
  • Landing zone, which must include either the brachiocephalic or left common carotid native ostium, cannot be aneurysmal, heavily calcified, or heavily thrombosed
  • Must have appropriate distal aortic landing zone, defined as:
  • Outer curvature length must be ≥2cm proximal to the celiac artery
  • Aortic inner diameters between 16-48 mm (diameter must be between 16-42mm if using distal TAG® Device extension)
  • Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed
  • Landing zone in native aorta or previously implanted GORE® TAG® Device
  • Must have appropriate target branch vessel landing zone, defined as:
  • Length of ≥3 cm proximal to first major branch vessel if using Aortic Component with 8 mm portal diameter, or length of ≥2.5 cm proximal to first major branch vessel if using Aortic Component with 12 mm portal diameter (required for Zone 0 Subjects)
  • Target branch vessel inner diameters of 6-15 mm if using Aortic Component with 8mm portal diameter, or inner diameters of 11-18 mm if using Aortic Component with 12mm portal diameter (required for Zone 0 Subjects)
  • Target branch vessel landing zone must be in native aorta that cannot be aneurysmal, heavily calcified, or heavily thrombosed

Who cannot join

  • Concomitant aneurysm/disease of the ascending aorta, or abdominal aorta requiring repair
  • Previous endovascular repair of the ascending aorta
  • Previous endovascular repair of the DTA with a non-Gore device
  • Surgery within 30 days of treatment
  • Infected aorta
  • Dissection of the aorta
Show all 24Show fewer
  • Intramural hematoma of the aortic arch or DTA without aneurysm
  • Life expectancy <2 years
  • Myocardial infarction or stroke within 6 weeks prior to treatment
  • Patient has a systemic infection and may be at increased risk of endovascular graft infection
  • Pregnant female at time of informed consent signature
  • Degenerative connective tissue disease, e.g. Marfan's or Ehler-Danlos Syndrome
  • Participation in another drug or medical device study within one year of study enrollment
  • Known history of drug abuse within one year of treatment
  • Significant thrombus or atheroma in the aortic arch
  • Tortuous or stenotic iliac and/or femoral arteries preventing introducer sheath insertion and the inability to use a conduit for vascular access
  • Planned coverage of celiac artery
  • Patient has known sensitivities or allergies to the device materials
  • Patient has known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment
  • Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin
  • Diameter taper outside of the device sizing range between proximal and distal landing zones of aorta and the inability to use additional devices of different diameters to compensate for the taper
  • Mycotic aneurysm
  • Persistent refractory shock (systolic blood pressure <90 mm Hg)
  • Patient has body habitus or other medical condition which prevents adequate visualization of the aorta

Trial locations and contacts

6 sites in 1 country.

6 sites in 1 country

United States6 sites
  • University of Michigan

    Ann Arbor, Michigan, 48109

  • The Hitchcock Foundation (Dartmouth Hitchcock Medical Center)

    Lebanon, New Hampshire, 03756

  • Hospital at University of Pennsylvania

    Philadelphia, Pennsylvania, 19104

  • Univerisity of Pittsburgh Medical Center

    Pittsburgh, Pennsylvania, 15232

  • Mayo Clinic Rochester

    Rochester, Minnesota, 55905

  • Leland Stanford Junior University

    Stanford, California, 94305-5407

Other trials in United States

About this study

Official title: Evaluation of the GORE® TAG® Thoracic Branch Endoprosthesis (Branched TAG® Device) in the Treatment of Aortic Arch Aneurysms

The purpose of this study is to assess the early feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the aortic arch

Read the detailed description

The GORE® TAG® Thoracic Endoprosthesis (TAG® Device) received premarket approval (PMA) for use in endovascular aneurysm repair of the descending thoracic aorta (DTA) on 23-Mar-2005 under P040043, and design changes that resulted in the conformable GORE® TAG® Thoracic Endoprosthesis (CTAG) received premarket approval for the treatment of aneurysms of the DTA on 23-Aug-2011 (P040043/S039). The TAG® Device and CTAG are intended to exclude an aneurysm from the blood circulation in patients diagnosed with DTA aneurysms. However, endovascular treatment options for patients with aortic arch aneurysms are limited as current stent graft technology would require coverage of aortic arch vessels. This prompted the creation of the GORE® TAG® Thoracic Branch Endoprosthesis (previously known as Branched TAG® Device), which was being evaluated under IDE G130120 for Zone 2 aneurysms when this clinical investigation was initiated to evaluate the GORE® TAG® Thoracic Branch Endoprosthesis for the treatment of Zone 0 and Zone 1 aneurysms of the aortic arch.

Being tested
GORE® TAG® Thoracic Branch Endoprosthesis
Medical subject headings
Aneurysm, Aortic Arch

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • GORE® TAG® Thoracic Branch EndoprosthesisDevice

Study groups in NCT02264977
Study groupRoleWhat they receive
Branched TAG® DeviceExperimentalTreatment with the GORE® TAG® Thoracic Branch Endoprosthesis
Receives: Device: GORE® TAG® Thoracic Branch Endoprosthesis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Successful Study Device Access

    Access to the aneurysm and target landing zone location is obtained via conventional vascular access and endovascular techniques.

    Measured: During treatment procedure (day 0)

  2. Number of Participants With Successful Study Device Deployment

    Absence of deployment failure will be considered a successful deployment. Deployment failure will be considered the failure of any Branched TAG® Device component (Aortic Component, Aortic Extender, or SB Component) to be released from the delivery catheter resulting in a serious adverse event (SAE) due to mechanical failure or use error.

    Measured: During treatment procedure (day 0)

  3. Number of Participants With Primary Procedural Side Branch Patency

    The presence of forward flow through the implanted Side Branch Component into the target branch vessel.

    Measured: At conclusion of the treatment procedure (day 0)

Secondary outcomes (2)
  1. Number of Participants With 1 Month Side Branch Primary Patency Assessed by an Independent Core Lab

    Measured: 1 Month

  2. Number of Participants Without 1 Month Device Related Endoleaks Assessed by an Independent Core Lab

    Device-related endoleaks are defined as the presence of contrast within the aneurysm sac originating from the junction between any Branched TAG® Device component and the landing zone (Type IA or IB) or the junction between the Aortic Component and either the Side Branch Component or the Aortic Extender (Type III).

    Measured: 1 Month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Oct 2014 (estimated)
  2. Study startApr 2015
  3. Primary completionJul 2016
  4. Study completionMar 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
9 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02264977
Sponsor's protocol ID
SSB 11-03
Status last verified
Aug 2022
First submitted
8 Oct 2014
Last updated
14 Sep 2022
Data monitoring committee
Yes

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in