AzTrials
AzTrials

Accidental FallsGFD1NCT02272933

Operability and Implementation of a Patient Motion Monitoring System Using Wireless Body Worn Sensors

A study testing Smart Slipper and Belt-Clip Sensor in people with Accidental Falls and Gait, Unsteady, run by Texas Tech University Health Sciences Center at 1 site in United States.

Withdrawn

Withdrawn. The study stopped before anyone enrolled.

Official record
Search all trials

Trial summary

In this observational study, a motion monitoring system including body-worn sensors, communication portals, data capture system, and algorithms will be tested with geriatric patients in Garrison Geriatric Education and Care Center (Lubbock, TX). Read more about this study

Who is it for?
Ages 45 to 85 yearsHealthy volunteers can take part
Conditions the study is for
Accidental Falls, Gait, Unsteady
What is being tested?
Smart Slipper and Belt-Clip Sensor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
1 siteUnited States
Study dates
Aug 2014to Oct 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 45 to 85 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • At least 30 day resident of Garrison.
  • Deemed mentally competent by primary care provider to make decisions regarding their daily shoe wear.
  • A resident prone to falls is eligible.
  • Willing to wear shoes and offer high level of compliance to study
  • Able to provide informed consent
  • Able to complete survey
  • Age range: 45-85 yrs

Who cannot join

  • 1. Unwilling to participate 2. Not mentally competent to provide informed consent
  • -

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Garrison Geriatric Education and Care Center

    Lubbock, Texas, 79415

Other trials in United States

About this study

In this observational study, a motion monitoring system including body-worn sensors, communication portals, data capture system, and algorithms will be tested with geriatric patients in Garrison Geriatric Education and Care Center (Lubbock, TX). The study is part of a long-term effort to improve the quality of life and safety of geriatric patients by using autonomous systems that can alert care givers of mobility issues and falls.

Read the detailed description

Medical monitoring systems have become an important area of research and development due to the possibility of allowing improved quality of life and care while reducing overall medical costs.

Significance of the study:

The study is significant because it will allow researchers to understand the efficacy of the autonomous sensor system used with actual residents of a geriatric care center. This study is one of the first attempts to monitor movements of geriatric residents as they go about their activities of daily living. This type of system has the potential to improve the quality of life and safety of geriatric patients.

Goals:

The development of autonomous patient monitoring technologies that will eventually improve the quality of life and safety of patients in geriatric care facilities and other environments.

Determine the performance and usability of the wearable sensor system in a geriatric care facility with actual residents going about their daily lives.

Specific Aims:

  1. Determine performance of motion data collect ion system for monitoring geriatric residents as they go about their daily life in a geriatric center
  2. Determine tolerability of wearing sensors by geriatric residents
  3. Understand how medical staff interacts with monitored residents and the sensor devices
  4. Determine if the sensor system's algorithms can identify falls

Objectives:

  1. Analyze the motion data generated by the system to determine system performance. The list of performance metrics will include: (a) system up-time, (b) continuity of data collection (c) sensor device failure rate, (d) sensor device battery life (e) simultaneous collection of data when multiple monitored residents are in the same localized area.
  2. Assess the tolerability of wearing the devices over the course of a day using a survey administered to residents.
  3. Assess the usability of the sensor system using a survey administered to care givers.
  4. Compare events flagged as falls by system algorithms with the fall log produced by Garrison staff, cross-verified against personal fall logs, to determine the ability of the system to detect falls.
Being tested
Smart Slipper, Belt-Clip Sensor
Medical subject headings
Gait Disorders, Neurologic

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Smart SlipperDevice

    The shoe measures foot pressure and motion allowing gait to be quantified.

  • Belt-Clip SensorDevice

    The sensor measures acceleration of the body allowing falls to be detected.

Study groups in NCT02272933
Study groupRoleWhat they receive
Wireless Body-Worn SensorsExperimentalElderly patients will wear sensors (Smart Slippers and a belt-clip sensor) as they go about their daily life in a geriatric care center.
Receives: Device: Smart Slipper; Device: Belt-Clip Sensor

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Detection of Fall Incidences

    Participants will be monitored for falls. The detection of fall events as determined by the sensors will be compared to the fall log kept by Garrison Geriatric Center.

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Oct 2014 (estimated)
  2. Study startAug 2014
  3. Primary completionOct 2017
  4. Study completionOct 2017

Why it stopped: No Study Enrollment

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02272933
Sponsor's protocol ID
L14-125
Acronym
GFD1
Status last verified
Dec 2019
First submitted
21 Oct 2014
Last updated
13 Dec 2019
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Smart Slipper and Belt-Clip Sensor in people with Accidental Falls and Gait, Unsteady, run by Texas Tech University Health Sciences Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 13 Dec 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Detection of Fall Incidences (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Dec 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in