Labor PainNCT02274467

Response Patterns to the Electric Stimulation of Epidural Catheters in Term Pregnant Women

A study testing Trans-catheter electric stimulation test in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Lumbar epidural analgesia is commonly used for labor pain relief due to its effectiveness and safety. Despite its very high success rate, the epidural technique remains a rather blind technique and failures continue to occur. Read more about this study

Who is it for?
Ages 18 to 50 years, women onlyHealthy volunteers can take part
Conditions the study is for
Labor Pain
What is being tested?
Trans-catheter electric stimulation test
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
48 participants
Where
1 siteCanada
Study dates
Nov 2014to Jan 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Women over 18 years of age requesting an epidural for labor and delivery
  • Able to communicate in English
  • Informed consent

Who cannot join

  • Refusal to provide written informed consent
  • Unable to communicate in English
  • Allergy or hypersensitivity to lidocaine, bupivacaine or fentanyl
  • Abnormal vertebral anatomy, including previous spine surgery and scoliosis
  • Coexisting neurological disorders
  • Implanted electronic devices

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Mount Sinai Hospital

    Toronto, Ontario, M5G1X5

Other trials in Canada

About this study

Official title: Response Patterns to the Electric Stimulation of Epidural Catheters in Term Pregnant Women: A Randomized Controlled Trial of Uniport Versus Multiport Catheters.

Lumbar epidural analgesia is commonly used for labor pain relief due to its effectiveness and safety. Despite its very high success rate, the epidural technique remains a rather blind technique and failures continue to occur. The correct placement of an epidural catheter, however, remains a clinical problem, since there is no imaging technique that could be used at the bedside to determine the exact positioning of the catheter. The technique of a trans-catheter electric stimulation test (TCEST) has been successfully used to detect the proper epidural catheter location for pediatric, post-operative and laboring obstetric patients. The response to the TCEST with the uniport (single hole) epidural catheters has been well described. There is a growing body of evidence that multiport epidural catheters provide an advantage to uniport catheters, since additional ports likely allow for an enhanced distribution of the local anesthetic solution. This was shown to result in a lower incidence of inadequate analgesia, including unilateral sensory blockade and missed sensory segments. The characteristics of the TCEST response using a multiport catheter remain to be determined. The aim of this study is to compare the response patterns to the TCEST using a single port versus multiport wire reinforced epidural catheters. The hypothesis of this study is that the incidence of a bilateral response to the TCEST will be higher in the multiport catheter as compared to the uniport catheter.

Read the detailed description

This will be a randomized double-blind controlled study. After recruitment of the patient, epidural anesthesia will be performed in the standard fashion employed in the investigators institution by a resident, fellow, or staff. Spinal ultrasound will be used prior to performing the epidural catheter insertion. Patients will be randomly allocated into two different groups to receive either a 19 gauge uniport catheter or a 19 gauge multiorifice catheter (Arrow Flextip plus, Arrow International Inc., Reading, PA). After securement of the catheter, the TCEST will be performed. The test will be repeated at 5 minutes, following a test dose, to determine the change in intensity of current required to elicit the motor response. Following the second testing, a loading dose of the standard anesthetic solution will be administered. The sensory level to ice will be tested at 20 minutes following injection of the loading dose of bupivacaine and fentanyl. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally Failure of the epidural analgesia will be assessed, defined as no evidence of a sensory block to ice and absent pain relief. The need for catheter replacement will be determined within 2 hours of the completion of the loading dose.

Conditions
Labor Pain
Being tested
Trans-catheter electric stimulation test
Keywords
Tsui Test, Labour, Epidural catheter
Medical subject headings
Labor Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Trans-catheter electric stimulation testDevice

    Also called Tsui test

Study groups in NCT02274467
Study groupRoleWhat they receive
Uniport catheterActive comparator19 gauge uniport epidural catheter
Receives: Device: Trans-catheter electric stimulation test
Multiport catheterActive comparator19 gauge multiorifice epidural catheter
Receives: Device: Trans-catheter electric stimulation test

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Motor response pattern

    Motor response pattern to the electrical stimulation of the epidural catheter, either unilateral or bilateral

    Measured: 5 minutes

Secondary outcomes (4)
  1. Current (mA)

    The current (mA) needed to elicit a motor response at control and at 5 minutes after the test dose

    Measured: 5 minutes

  2. Sensory level

    The sensory level to ice at 20 minutes following injection of the standard epidural loading dose. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally

    Measured: 20 minutes

  3. Epidural block failure

    Failure of the epidural analgesia, defined as no evidence of a sensory block to ice and absent pain relief

    Measured: 20 minutes

  4. Catheter replacement

    Need for catheter replacement within 2 hours of the completion of the loading dose

    Measured: 2 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Oct 2014 (estimated)
  2. Study startNov 2014
  3. Primary completionJan 2015
  4. Study completionJan 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Quadruple blind
Who is masked
Participant, Care provider, Investigator, Outcomes assessor
Enrolment
48 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02274467
Sponsor's protocol ID
14-05
Status last verified
Feb 2015
First submitted
9 Oct 2014
Last updated
19 Feb 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Trans-catheter electric stimulation test in people with Labor Pain, run by Samuel Lunenfeld Research Institute, Mount Sinai Hospital at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Feb 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Motor response pattern (time frame: 5 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Feb 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in