AzTrials
AzTrials

Osteoarthritis, KneeNCT02276118

Outcome Comparison of Two Total Knee Arthroplasty Systems: e.Motion-Pro Versus Genesis II

A study testing device: e.motion PS Pro and device : Genesis II in people with Osteoarthritis, Knee, run by Seoul National University Hospital at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Recently, E.Motion-PS-Pro (B.Braun-Aesculap, Tuttlingen, Germany), a new mobile bearing knee system with a unique ball and socket post-cam mechanism was developed for use in total knee arthroplasty. Read more about this study

Who is it for?
Ages Up to 79 years
Conditions the study is for
Osteoarthritis, Knee
What is being tested?
device: e.motion PS Pro and device : Genesis II
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
300 participants
Where
1 siteSouth Korea
Study dates
Jul 2014to Dec 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 79 years
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • patients who are decided to undergo total knee arthroplasty with diagnosis of primary osteoarthritis

Who cannot join

  • the diagnosis other than primary osteoarthritis
  • previous history of infection or trauma requiring surgical treatment on the knee which will receive total knee arthroplasty
  • patients of 80 years or older
  • patients with systemic diseases that can affect functional outcomes of TKA

Trial locations and contacts

1 site in 1 country.

Tae Kyun Kim, MD, PhD contact

82-31-787-7196

osktk@snubh.org

South Korea1 site, 1 recruiting
  • Joint Reconstruction Center, Seoul National University Bundang Hospital

    Seongnam-si, Gyeonggi-do, 463-707

    Tae Kyun Kim, MD, PhD, 82-31-787-7196, osktk@snubh.org

    Tae Kyun Kim, MD, PhD

    Recruiting

Other trials in South Korea

About this study

Official title: Comparisons of Prosthesis Fitness, Early Recovery Patterns, Functional Outcomes and Patient Satisfaction Between E.Motion-Pro, a New Mobile Bearing System and Genesis II, an Established Successful System

Recently, E.Motion-PS-Pro (B.Braun-Aesculap, Tuttlingen, Germany), a new mobile bearing knee system with a unique ball and socket post-cam mechanism was developed for use in total knee arthroplasty. This study aims to determine (1) whether the use of E.Motion-PS-Pro improves prosthesis fitness for the femur and tibia in terms of under- or over-hang incidence compared to an established successful prosthesis, Genesis II (Smith \& Nephew, Memphis, U.S.A.), (2) whether patients with this new prosthesis experience less pain and faster wound healing in early recovery phase, (3) whether patients with E.Motion-Pro reach functional plateaus faster than patients with Genesis II and the functional plateaus of patients with E.Motion-Pro are higher than those of patients with Genesis II.

Read the detailed description

Total knee arthroplasty (TKA) is a satisfactory treatment option for patients with advanced knee diseases that are intractable with other modalities in terms of pain relief, functional restoration, and deformity correction. Unfortunately, however, many patients have to go through a recovery period of several months during which they experience considerable pain and suffer from incompletely restored functions. In recent years, to improve the quality of life during early recovery period after TKA, great efforts have been made in multiple areas including the use of minimally invasive surgical technique, improved pain management protocols, and postoperative rehabilitation protocols. Nonetheless, this almost inevitable presence of painful and disabling recovery period is a major concern to patients scheduled for or considering TKA as a treatment option. Furthermore, this issue can become a more serious obstacle to very elderly patients who have to balance the benefits of remaining years with improved functions from replaced knees and the burden of recovery duration after TKA.

In theory, the use of a better fitting prosthesis with sound kinematic performance can shorten the duration of recovery period and improve the quality of life by reducing pain and facilitating functional recovery. Better fitting prostheses allegedly less involve prosthesis overhang at femoral condylar level, which can cause impingement symptoms and at anterior flange area, which can cause patellofemoral symptoms. Prosthesis providing better kinematic performance such as natural motion and joint stability throughout motion arc can reduce pain and discomfort in early recovery period and shorten the duration of recovery period.

Recently, E.Motion-PS-Pro (B.Braun-Aesculap, Tuttlingen, Germany), a new mobile bearing knee system with a unique ball and socket post-cam mechanism was developed. This new prosthesis was designed to achieve better prosthesis fitting, to minimize bone loss from box preparations for post-cam mechanism, to improve joint stability throughout motion arc, particularly in high flexion, and to reduce the risk for wear and fracture at the post by increasing contact area. If the intended design rationales work out well, this prosthesis shall reduce soft tissue impingement and provide better kinematic performances, which reduces pain and facilitates functional restoration.

Therefore, the current investigators aim to determine (1) whether the use of E.Motion-PS-Pro improves prosthesis fitness for the femur and tibia in terms of under- or over-hang incidence compared to an established successful prosthesis, Genesis II (Smith \& Nephew, Memphis, U.S.A.), (2) whether patients with this new prosthesis experience less pain and faster wound healing in early recovery phase, (3) whether patients with E.Motion-Pro reach functional plateaus faster than patients with Genesis II and the functional plateaus of patients with E.Motion-Pro are higher than those of patients with Genesis II. The investigators hypothesize that (1) E.Motion-Pro reduces the incidence of prosthesis under- or over-hang, (2) patients with E.Motion-Pro experience less pain and faster wound healing in early recovery phase, and (3) patients with E.Motion-Pro reach functional plateau faster and the functional outcomes at 1 year are better in patients with E.Motion-Pro than those with Genesis II.

Being tested
device: e.motion PS Pro, device : Genesis II
Medical subject headings
Osteoarthritis, Knee

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • device: e.motion PS ProDevice

    patients will undergo total knee arthroplasty with e.motion PS Pro implant

  • device : Genesis IIDevice

    patients will undergo total knee arthroplasty with Genesis II implant

Study groups in NCT02276118
Study groupRoleWhat they receive
e.motion PS Pro groupExperimentalthe patients who receives total knee arthroplasty with the e.motion PS pro prosthesis
Receives: Device: device: e.motion PS Pro
Genesis II groupActive comparatorthe patients who receives total knee arthroplasty with the Genesis II prosthesis
Receives: Device: device : Genesis II

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. prosthesis fit

    Component fitness will be evaluated by whether there is overhang (too wide or big) or underhang (too narrow or small) more than 2 mm at any of three sites: condyle, junction, and anterior flange

    Measured: from the start to end of surgery (expected average of 90 minutes)

  2. pain level during gait at 3 months after surgery

    Pain levels will be evaluated by asking how much pain patients feel during weight bearing gait at 3 months in 0-10 visual analog scale (0-no pain and 10-maximum pain)

    Measured: at 3 months after surgery

  3. knee swelling (circumference measured at the knee) at 3 months

    Knee swelling will be evaluated by measuring the leg circumference at the knee level (mid-patella), and the measured circumference will be compared with the preoperative circumference

    Measured: at 3 months after surgery

  4. flexion contracture and maximum flexion at 3 months

    Flexion contracture and further flexion will be measured by a single investigator using a 38-cm clinical goniometer with patients supine

    Measured: at 3 months after surgery

  5. the new American Knee Society (AKS) score at 6 months

    Patients will be evaluated at 6 months using the new scoring system of American Knee Society. The American Knee Society scoring system evaluates multiple aspects of outcomes: 1) Objective knee indicators (maximum points 80) - alignment (25), mediolateral (ML) stability (15), anteroposterior (AP) stability (10), range of motion (ROM) (30); 2) Knee score (maximum points 80) - symptoms (25), patient satisfaction (40), and expectation (15); 3) Function score (maximum points 100) - walking \& standing (30), standard activities (30), advanced activities (25), discretionary knee activities (15)

    Measured: at 6 months after surgery

Secondary outcomes (10)
  1. whether balanced gaps were achieved

    Balanced gap achievement will be called when flexion-extension and medio-lateral gaps are not beyond 2 mm difference

    Measured: from the start to end of surgery (expected average of 90 minutes)

  2. tourniquet time

    Tourniquet time will be measured as the duration in minutes from the point making skin incision to deflating tourniquet to check whether arterial bleeders are after implant fixation

    Measured: from the start to end of surgery (expected average of 90 minutes)

  3. blood volume drained via a vacuum drainage in the subcutaneous tissue

    blood volume drained via a vacuum drainage will be measured as the total amount drained from the end of surgery to removal of vacuum drainage in mL.

    Measured: from the end of surgery to removal of vacuum drainage (usually at 2 days after surgery)

  4. hemoglobin drop on postoperative 2 and 5 days

    hemoglobin drop on the 2nd and 5th postoperative days will be evaluated by subtracting hemoglobin level on the 2nd or 5th day from the preoperative level.

    Measured: at 2 and 5 days after surgery

  5. pain level during motion arc exercise at 2 and 6 weeks

    Pain levels during motion arc exercise will be evaluated at 2 and 6 weeks using 0-10 Visual Analogue Scale.

    Measured: at 2 and 6 weeks after surgery

  6. knee swelling at 2 and 6 weeks

    knee swelling will be evaluated at 2 and 6 weeks by noting the leg circumference at the mid-patella level

    Measured: at 2 and 6 weeks after surgery

  7. need for walking aid at 6 weeks

    Whether patients still need a walking aid (yes/no) will be noted at 6 weeks

    Measured: at 6 weeks after surgery

  8. patient satisfaction with early recovery pattern at 3 months

    Patient satisfaction with early recovery pattern will be evaluated at 3 month using a 0-4 Likert scales (0-disappointed, 1-less satisfactory than expected, 2 - as expected, 3- more satisfactory than expected, 4 - extremely satisfactory)

    Measured: at 3months after surgery

  9. flexion contracture and further flexion at 6 weeks, and 6, 12, 24 months

    Motion arc will be evaluated in extension deficit (flexion contracture) and maximum flexion at 6 weeks, 6 months, 12 months, and 2 years

    Measured: at 6 weeks, and 6, 12, 24 months after surgery

  10. patient satisfaction with replaced knees at 12 and 24 months

    Patients will be evaluated for their satisfaction with replaced knees at 12 and 24 months after surgery with 0-4 Likert scale and 0-10 Visual analogue scale.

    Measured: at 12 and 24 months after surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Oct 2014 (estimated)
  2. Study startJul 2014
  3. Primary completionJul 2015 (estimated)
  4. Study completionDec 2015 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
300 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02276118
Sponsor's protocol ID
E-1406/254-001
Status last verified
Jul 2014
First submitted
19 Oct 2014
Last updated
27 Oct 2014
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing device: e.motion PS Pro and device : Genesis II in people with Osteoarthritis, Knee, run by Seoul National University Hospital at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 27 Oct 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Tae Kyun Kim, MD, PhD (82-31-787-7196, osktk@snubh.org), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

prosthesis fit (time frame: from the start to end of surgery (expected average of 90 minutes)). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Oct 2014.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in