Diabetes Mellitus, Type 1NCT02283411

Effectiveness and Safety Study of the Abbott Sensor Based Glucose Monitoring Systems

A study testing Abbott Sensor Based Glucose Monitoring System in people with Diabetes Mellitus, Type 1 and Diabetes Mellitus, Type 2, run by Abbott Diabetes Care at 6 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of the study is to evaluate the safety and effectiveness of the Abbott Sensor Based Glucose Monitoring System Personal (System-P) and Abbott Sensor Based Glucose Monitoring System Professional (System-Pro) when used as an adjunct to blood glucose testing over a 14-day wear period in adult subjects. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
Abbott Sensor Based Glucose Monitoring System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
156 participants
Where
6 sitesUnited States
Study dates
Nov 2014to Mar 2015
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Subject must be at least 18 years of age.
  • Subject must have a diagnosis of type 1 or type 2 diabetes mellitus.
  • Use one of the following for their diabetes management:
  • intensive insulin therapy (insulin therapy through an insulin pump and/or multiple daily insulin injections) or
  • non-intensive insulin therapy (Basal insulin, injectable non-insulin anti-diabetic agents such as a pramlintide or GLP-1 agonists, NPH insulin either alone or in combination with regular insulin or fast acting insulin analogue, or oral medication)
  • Intensive-insulin using (IIT) subjects only - During one of the in-clinic sessions, subject is willing to have their blood glucose levels manipulated into high and low glucose levels. Insulin-to-carbohydrate ratio and insulin sensitivity formula must be documented prior to having blood glucose levels manipulated. NIT subjects will only be observed during each in-clinic session.
Show all 12Show fewer
  • For subjects that exercise routinely (at least 3 times per week), willing to exercise during at least one of the in-clinic sessions, if asked.
  • Willing to perform a minimum of 8 finger sticks per day during the study.
  • Subject must be able to read and understand English.
  • In the investigator's opinion, the subject must be able to follow the instructions provided to him/her by the study site and perform all study tasks as specified by the protocol.
  • Subject must be available to participate in all study visits.
  • Subject must be willing and able to provide written signed and dated informed consent.

Who cannot join

  • Subject has known allergy to medical grade adhesive or isopropyl alcohol used to disinfect skin.
  • Subject is pregnant, is attempting to conceive or is not willing and able to practice birth control during the study duration (applicable to female subjects only).
  • Subject has extensive skin changes/diseases at the proposed application sites that could interfere with device placement or the accuracy of interstitial glucose measurements. Such conditions include, but are not limited to extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, dermatitis herpetiformis, skin lesions, redness, infection or edema.
  • Subject is on dialysis.
  • Subject has a history of untreated hypothyroidism, adrenal gland failure or insufficiency, celiac disease, renal failure, cystic fibrosis, unstable coronary heart disease, or serious psychiatric disorders.
  • Subjects with a history of hypoglycemia unawareness, hypoglycemic seizures or unconsciousness.
Show all 20Show fewer
  • Subjects who have experienced diabetes-related complications requiring assistance from another person in the last six months.
  • Subject currently is participating in another clinical trial.
  • Subject has donated blood within 112 days (3.7 months) prior to the beginning of the study activities.
  • Subject is anemic.
  • Subject does not have a known insulin to carbohydrate ratio at the time of enrollment (IIT subjects only).
  • Subject has concomitant medical condition which, in the opinion of the investigator, could interfere with the study or present a risk to the safety or welfare of the subject or study staff. Such conditions include but are not limited to:
  • History of HIV, Hepatitis B or C
  • Subject has X-ray, MRI or CT appointment scheduled during the period of study participation, and the appointment cannot be rescheduled for a time before study participation starts or after study participation ends.
  • Subject has an abnormal EKG, unless cleared for study participation by a cardiologist.
  • Subject is unsuitable for participation due to any other cause as determined by the Investigator.
  • Additional Criteria
  • The following subjects may participate in the study but will be excluded from all glycemic and exercise challenges:
  • Subject's taking medications known to mask symptoms or hypoglycemia, such as beta blockers;
  • Subjects with any of the following: clinically significant history of cardiovascular or cerebrovascular disease, cardiac arrhythmia, neurological disorders such as seizures, CVA, or syncope, or hypokalemia.

Trial locations and contacts

6 sites in 1 country.

6 sites in 1 country

United States6 sites
  • Atlanta Diabetes Associates

    Atlanta, Georgia, 30318

  • Rocky Mountain Diabetes & Osteoporosis Center

    Idaho Falls, Idaho, 83404

  • Rainier Clinical Research Center

    Renton, Washington, 98057

  • Clinical Trials of Texas

    San Antonio, Texas, 78229

  • William Sansum Diabetes Center

    Santa Barbara, California, 93105

  • Diablo Clinical Research

    Walnut Creek, California, 94598

Other trials in United States

About this study

Official title: Effectiveness and Safety Study of the Abbott Sensor Based Glucose Monitoring System - Personal and Abbott Sensor Based Glucose Monitoring System - Professional

The purpose of the study is to evaluate the safety and effectiveness of the Abbott Sensor Based Glucose Monitoring System Personal (System-P) and Abbott Sensor Based Glucose Monitoring System Professional (System-Pro) when used as an adjunct to blood glucose testing over a 14-day wear period in adult subjects. The Abbott Sensor Based Glucose Monitoring System - Professional Sensors will be worn by adult subjects over a 14-day wear period.

The primary objective is to characterize the Systems performance with respect to Yellow Spring Instrument (YSI) reference venous sample measurements. The device performance will be primarily evaluated in terms of point and rate accuracy of the Abbott Sensor Based Glucose Monitoring Systems in reference to YSI.

Read more

Safety of the Abbott Sensor Based Glucose Monitoring Systems will be characterized by Adverse Device Effects and Serious Adverse Device Effects experienced by study participants.

240 subjects will be enrolled and additional healthy subjects may also be enrolled in the study as training subjects.

Read the detailed description

Sensors are inserted into the back of the subject's upper arm for up to fourteen (14) days. The subjects are expected to perform capillary BG tests during the 14-day sensor wear. Three in clinic visits are scheduled during the 14-day sensor wear period. During each in-clinic visit, study staff performed IV blood draws to obtain venous blood for YSI reference glucose measurements.

Being tested
Abbott Sensor Based Glucose Monitoring System
Medical subject headings
Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Abbott Sensor Based Glucose Monitoring SystemDevice

    Subjects will wear the Abbott Sensor Based Glucose Monitoring Systems and will receive no treatment except for safety purposes.

Study groups in NCT02283411
Study groupRoleWhat they receive
Diabetes Mellitus, Type 1 and Type 2OtherSubjects will wear the Abbott Sensor Based Glucose Monitoring Systems and will receive no treatment except for safety purposes.
Receives: Device: Abbott Sensor Based Glucose Monitoring System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The Device Performance Was Evaluated in Terms of Point Accuracy of the Abbott Sensor Based Glucose Monitoring Systems in Reference to Yellow Spring Instrument (YSI).

    Point accuracy of the system was evaluated as the proportion of System readings that are within ±20% of the YSI reference value for glucose levels ≥ 80 mg/dL and within ±20 mg/dL for YSI glucose levels <80 mg/dL. All 125 subjects wore both System-P and System-Pro Sensors and were included in the outcome measure. System P, the Personal System which is intended for single patient use and System Pro is intended for use by healthcare professionals (HCP). Each subject had up to 136 YSI samples collected during the study which were paired with sensor glucose readings measured at the same time. Point accuracy of the system was evaluated as the percentage of sensor glucose readings that are within ±20% of the YSI reference value for glucose levels ≥ 80 mg/dL and within ±20 mg/dL for YSI glucose levels <80 mg/dL.

    Measured: 14 days

  2. Safety of the Abbott Sensor Based Glucose Monitoring Systems Was Characterized by Adverse Device Effects and Serious Adverse Device Effects Experienced by Study Participants.

    Safety of the Abbott Sensor Based Glucose Monitoring Systems, including adverse device effects and serious adverse device effects were assessed for all participants enrolled in the study.

    Measured: Safety was evaluated throughout the subject's study participation.

Secondary outcomes (3)
  1. The Trend Accuracy of the System P Device Performance Was Evaluated.

    Trend accuracy of the device performance was assessed by comparing of the glucose rate of change results between the sensor glucose readings and YSI reference results for System P only.

    Measured: 14 days

  2. The Temporal System Accuracy at Different Glucose Rates of Change and Different Glucose Ranges (Hypoglycemic, Euglycemic, and Hyperglycemic Ranges) Was Evaluated.

    The Continuous Glucose Error Grid Analysis (CG-EGA) in the Hypoglycemic range (YSI ≤ 70 mg/dL), in the Euglycemic range (70 < YSI ≤ 180 mg/dL) and in the Hyperglycemic range (YSI > 180 mg/dL) were evaluated.

    Measured: 14 days

  3. The Point Accuracy of the Device Performance Was Evaluated in Reference to Capillary Blood Glucose (BG).

    Point accuracy of the system was evaluated as the proportion of System readings that are within ±20% of the capillary blood glucose (BG) value for glucose levels ≥ 80 mg/dL and within ±20 mg/dL for capillary blood glucose (BG) levels <80 mg/dL. All 125 subjects wore both System-P and System-Pro Sensors and were included in the outcome measure. System P, the Personal System which is intended for single patient use and System Pro is intended for use by healthcare professionals (HCP). Each subject had approximately112 capillary blood glucose (BG) samples collected during the study which were paired with sensor glucose readings measured at the same time. Point accuracy of the system was evaluated as the percentage of sensor glucose readings that are within ±20% of the BG value for glucose levels ≥ 80 mg/dL and within ±20 mg/dL for BG levels <80 mg/dL.

    Measured: 14 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Nov 2014 (estimated)
  2. Study startNov 2014
  3. Primary completionMar 2015
  4. Study completionMar 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
156 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02283411
Sponsor's protocol ID
ADC-US-VAL-14135
Status last verified
Jan 2018
First submitted
31 Oct 2014
Last updated
22 Feb 2018
Data monitoring committee
No
Individual data sharing
Undecided: Undecided to whether to make individual participant data available.

Questions about this trial

What is this clinical trial studying?

A study testing Abbott Sensor Based Glucose Monitoring System in people with Diabetes Mellitus, Type 1 and Diabetes Mellitus, Type 2, run by Abbott Diabetes Care at 6 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 12 inclusion and 20 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Feb 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 22 Feb 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The Device Performance Was Evaluated in Terms of Point Accuracy of the Abbott Sensor Based Glucose Monitoring Systems in Reference to Yellow Spring Instrument (YSI). (time frame: 14 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Feb 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in