AzTrials
AzTrials

Cardiac ArrestCPR_NURSENCT02294721

Pediatric Resuscitation With Feedback Devices

A study testing Standard BLS, The CPREazy and TrueCPR in people with Cardiac Arrest, run by International Institute of Rescue Research and Education at 1 site in Poland.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of this study was to compare four different CPR feedback devices to standard BLS in terms of the quality of single rescuer pediatric resuscitation. Therefore, the investigators hypothesis was that there would be no difference between CPR methods in terms of chest compression quality parameters. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Cardiac Arrest
What is being tested?
Standard BLS, The CPREazy and TrueCPR
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
1 sitePoland
Study dates
Nov 2014to Dec 2014
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • give voluntary consent to participate in the study
  • medical profession (nurses)

Who cannot join

  • not meet the above criteria
  • wrist or low back diseases

Trial locations and contacts

1 site in 1 country.

Poland1 site, 1 recruiting
  • International Institute of Rescue Research and Education

    Warsaw, Masovia, 03-122

    Lukasz Szarpak

    Andrzej Kurowski

    Recruiting

Other trials in Poland

About this study

Official title: Quality of Pediatric Chest Compression: Comparing Four CPR Feedback Devices With Standard BLS by a Single Rescuer: A Randomised Controlled Manikin Trial

The aim of this study was to compare four different CPR feedback devices to standard BLS in terms of the quality of single rescuer pediatric resuscitation. Therefore, the investigators hypothesis was that there would be no difference between CPR methods in terms of chest compression quality parameters.

Read the detailed description

Cardiac arrest is a leading cause of death worldwide. High-quality chest compressions are of paramount importance for survival and good neurological outcome. Unfortunately, even health professionals have difficulty performing effective CPR. Chest compression (CC) is often too shallow, compression ratio is inadequate, and hands-off time is too long. CPR feedback devices might be an option for rescuers to in order to increase CC efficiency.

Conditions
Cardiac Arrest
Being tested
Standard BLS, The CPREazy, TrueCPR, The CPR PRO APP, The CardioPump
Medical subject headings
Heart Arrest

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard BLSDevice

    Resuscitation without feedback devices, standard manual standard basic life support

  • The CPREazyDevice

    feedback device-1

  • TrueCPRDevice

    feedback device -2

  • The CPR PRO APPDevice

    feedback device -3

  • The CardioPumpDevice

    feedback device- 4

Study groups in NCT02294721
Study groupRoleWhat they receive
Without feedbackExperimentalParticipants compress the chest of the manikin without CPR feedback device
Receives: Device: Standard BLS
With feedbackExperimentalParticipants compress the chest of the manikin with CPR feedback device.
Receives: Device: The CPREazy; Device: TrueCPR; Device: The CPR PRO APP; Device: The CardioPump

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Effective compressions

    Effective compressions was defined as compression with correct depth (40-50mm), correct hand position and complete decompressions

    Measured: 1 day

Secondary outcomes (7)
  1. Chest compression depth

    To measure chest compression depth during 8 minutes. Chest compression depth will be measured using the software connected to the manikin and computer

    Measured: 1 day

  2. Chest compression rate

    To measure the chest compression rate during 8 minutes. Chest compression rate will be measured using the software connected to the manikin and computer

    Measured: 1 day

  3. effective compressions ratio

    effective compressions ratio was defined as effective compressions [%] multiplied by flow time [%]

    Measured: 1day

  4. Flow time was defined as the sum of all periods during which chest compressions were performed

    flow time was defined as the sum of all periods during which chest compressions were performed.

    Measured: 1 day

  5. absolute hands-off time

    absolute hands-off time (HOT) was defined as the sum of all periods without chest compressions or ventilation

    Measured: 1 day

  6. VAS (visual analogue scale)

    after having completed the 8 min testing period, the study participants were asked how challenging they had experienced standard BLS or resuscitation which the respective feedback device. answers were rated on a 10-point Lickert scale (most difficult = 1 to easiest = 10)

    Measured: 1 day

  7. Prefered CPR device

    after having completed the 8 min testing period, the study participants were asked how chellenging whitch method they would preferred. answers were rated on a 10-point Lickert scale (lower preferred = 1 to most preferred = 10)

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Nov 2014 (estimated)
  2. Study startNov 2014
  3. Primary completionDec 2014 (estimated)
  4. Study completionDec 2014 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02294721
Sponsor's protocol ID
CPR/2014/10
Acronym
CPR_NURSE
Status last verified
Nov 2014
First submitted
16 Nov 2014
Last updated
19 Nov 2014
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Standard BLS, The CPREazy and TrueCPR in people with Cardiac Arrest, run by International Institute of Rescue Research and Education at 1 site in Poland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 19 Nov 2014. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Andrzej Kurowski (+48500186225, andrzejkurowski987@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Effective compressions (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Nov 2014.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Pediatric Resuscitation With Feedback Devices | AzTrials