Biliary Tract DiseasesNCT02310230

An Evaluation of the Utility of the ExSpiron Respiratory Variation Monitor During Upper GI Endoscopy

A study testing ExSpiron Respiratory Variation Monitor in people with Biliary Tract Diseases and Stomach Neoplasms, run by Donald Mathews at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Purpose: To assess the utility of a new medical device that monitors a patient's breathing during medical procedures in which a patient is sedated, but not mechanically ventilated. Read more about this study

Who is it for?
Ages 21 years and older
What is being tested?
ExSpiron Respiratory Variation Monitor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteUnited States
Study dates
22 Sep 2014to 9 May 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subjects undergoing upper gastrointestinal endoscopy

Who cannot join

  • Patients with a history of thoracotomy with resection of lung tissue
  • Patients with a history of severe chronic obstructive pulmonary disease (defined as an inability to climb a flight of stairs or FEV1/VC of less than 30% of predicted)
  • BMI greater than 43.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of Vermont Medical Center

    Burlington, Vermont, 05401

Other trials in United States

About this study

Purpose: To assess the utility of a new medical device that monitors a patient's breathing during medical procedures in which a patient is sedated, but not mechanically ventilated. In minor procedures, such as endoscopy (where the doctor examines a patient's digestive tract by a TV camera inserted through the mouth), patients do not require general anesthesia, in which a machine would take over their breathing while they are unconscious for surgery. However, during endoscopic procedures it is sometimes difficult for the anesthesiologist to monitor the patient's breathing-specifically, to monitor changes in breathing patterns and the adequacy of breathing. In endoscopy procedures, the room is darkened, and the patient's mouth is generally occupied by the endoscope. While the anesthesiologist can listen to the patient's breathing sounds with a stethoscope, this type of monitoring can only be done periodically, and there is limited ability to gauge the adequacy of ventilation. This study will use the ExSpiron Respiratory Volume Monitor (RVM), which measures non-invasive minute ventilation (MV), tidal volume (TV) and respiratory rate (RR), in patients undergoing an endoscopic procedure to provide additional information regarding the effects of clinical interventions such as drug administrations or airway maneuvers on the patient's respiratory status.

For patients who give informed consent, study participation means that they will have a PadSet consisting of 3 electrodes applied to the chest. Another component, a nasal cannula (a thin clear plastic tube that goes under the nose) will give patients supplemental oxygen, and is standard of care for endoscopy at UVM Medical Center. Patients will then be asked to breathe in and out of a portable spirometer (breath meter) for 30 seconds up to five times. This data will be compared to data recorded by the monitor to confirm that the monitor is recording accurately. The procedure will then go forward in the normal fashion. Patients will be randomly placed into one of two groups. In the first group during the procedure, the anesthesiologist will not be able to see the numbers (MV, TV, and RR) displayed screen of the monitor, so the data will not be used to guide the patient's clinical care. In the second group, the anesthesiologist will be able to see the RVM measurements of MV, TV, and RR to evaluate the effect of the interventions. Monitoring for both groups will continue in the recovery room, until discharge.

Read the detailed description

The purpose of this study is to assess the utility of the ExSpiron Respiratory Variation Monitor in patients undergoing an interventional procedure with anesthesia. The primary outcome measure will be the average minute ventilation of the patient during the procedure. This study will also examine the correlation between clinical interventions such as drug administrations or airway maneuvers with data from the monitor. Additionally the study may provide information about the ability of this new monitoring system to prevent hypoxemia during these procedures and to consider its utility, compared with capnography, to detect hypopnea.

Background Assessing the adequacy of ventilation during Monitored Anesthesia Care (MAC) and sedation is difficult. Agents used to provide procedural sedation can depress ventilatory drive and can interfere with airway patency, making it much more likely that the patient will hypoventilate and experience partial or complete obstruction to ventilation. [It is actually clinically easier to administer general anesthesia and insert an airway management device such as an endotracheal tube or a laryngeal mask airway , however given the superior recovery profile following sedation vs. general anesthesia, it is usually preferable to administer sedation, if the procedure can be performed with its use.] The American Society of Anesthesiologists maintains a database of closed malpractice claims which allows analysis of patterns of injury. A study considering claims from MAC/sedation cases found that 40% of the MAC claims resulted in death or brain damage, that 25% of the claims that were associated with oversedation/hypoventilation occurred in the endoscopy suite, and that 44% of the oversedation cases could have been prevented by better monitoring.1 A study comparing claims from remote locations (such as endoscopy) with operating rooms, found that 50% of remote location claims involving monitored anesthesia care, the proportion of claims for death was increased in remote location claims [54 vs. 29% (operating room claims)], respiratory damaging events were more common in remote location claims (44 vs. 20%), with inadequate oxygenation/ventilation the most common specific event (21 vs. 3% in operating room claims), and that remote location claims were more often judged as being preventable by better monitoring (32 vs. 8% for operating room claims).2

Upper endoscopy procedures, such as upper GI endoscopy and endoscopic retrograde cholangiopancreatography (ERCP), are particularly challenging where the anesthesiologist has limited access to the patient's head and is working in darkened rooms. Indeed investigators have found it very difficult to find a combination of propofol and short acting opioid that allows instrumentation of the esophagus without "intolerable ventilatory depression".3 Trying to assess ventilation by observing chest excursion or listening to ventilation with a stethoscope under these conditions can be difficult and can be done only periodically. Side-stream nasal cannula end-tidal capnography offers a possible solution, but the cannula can become dislodged and the proceduralist's endoscope often interferes with its function. End-tidal capnography in the non-intubated patient is very insensitive to changes in minute ventilation. At best, this technology can usually assess only the presence or absence of ventilation: there is limited ability to judge the adequacy of ventilation or to quantify it.4

The Study Device The ExSpiron Respiratory Volume Monitor (Respiratory Motion, Inc., Waltham MA) has FDA 501(k) clearance to be used for patient care. It consists of a proprietary PadSet that is placed on the chest in the mid-axillary line and connected to a free standing monitor. This monitor measures and analyzes the changes in thoracic electrical impedance that occur during the respiratory duty cycle. It is able to quantify respiratory rate and also determine tidal volume and minute ventilation as well as graphically display changes in lung volumes. It has been shown to accurately measure the effect of interventions (medications, airway maneuvers) in endoscopy patients.5 Preliminary work has determined optimal lead placement demonstrated excellent correlation to spirometry with an R value of 0.94-0.98 and excellent accuracy and precision.6

Preliminary work cited below has shown that the monitor provides information about the effect of medications and airway maneuvers on breathing patterns that is not available with routine monitoring. This study seeks to extend that knowledge by investigating whether using this information in real-time results in different respiratory measurements compared to patients with routine monitoring.

Being tested
ExSpiron Respiratory Variation Monitor
Keywords
Endoscopy, Upper, Minute Ventilation, Tidal Volume, Respiratory Rate
Medical subject headings
Biliary Tract Diseases, Stomach Neoplasms, Carcinoma, Pancreatic Ductal, Barrett Esophagus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ExSpiron Respiratory Variation MonitorDevice

    Non-invasive monitoring of minute ventilation, tidal volume, and respiratory rate.

Study groups in NCT02310230
Study groupRoleWhat they receive
Blinded GroupOtherData from the ExSpiron Respiratory Variation Monitor (minute ventilation, tidal volume, and respiratory rate) will not be displayed. The anesthesia provider will care for the patient in the usual manner.
Receives: Device: ExSpiron Respiratory Variation Monitor
Monitor GroupExperimentalThe ExSpiron Respiratory Variation Monitor will display continuous real-time measurements of minute ventilation, tidal volume, and respiratory rate, and the anesthesia provider will be instructed to utilize this information in the care of the patient as they deem appropriate.
Receives: Device: ExSpiron Respiratory Variation Monitor

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Average Minute Ventilation in Patients Cared for Using the ExSpiron Respiratory Variation Monitor (RVM) Compared to Patients With Routine Monitoring in Patients Undergoing Upper Gastrointestinal Endoscopy

    Minute ventilation (or respiratory minute volume) is defined as the volume of air that can be inhaled or exhaled during one minute. The ExSpiron Respiratory Variation Monitor is able to quantify respiratory rate and also determine tidal volume and minute ventilation. The monitor measures a patient's baseline minute ventilation (MV) at the beginning of the case, and then compares subsequent minute volumes to that baseline, measured as a percentage of the baseline. In that respect, the minute ventilation (MV) values can often exceed 100 percent.

    Measured: Duration of procedure: Approximately 60 minutes

Secondary outcomes (2)
  1. Incidence of Airway Maneuvers Required to Maintain Ventilation in Each Group

    Measured: Duration of procedure: Approximately 60 minutes

  2. Time With Low Minute Ventilation

    Percentage of procedure time spent with Minute Ventilation less than 40% of the Minute Ventilation Baseline. Minute ventilation (or respiratory minute volume) is defined as the volume of air that can be inhaled or exhaled during one minute. The ExSpiron Respiratory Variation Monitor is able to quantify respiratory rate and also determine tidal volume and minute ventilation.

    Measured: Duration of Procedure: Approximately 60 Minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Dec 2014 (estimated)
  2. Study start22 Sep 2014
  3. Primary completion9 May 2016
  4. Study completion9 May 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Care provider
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02310230
Sponsor's protocol ID
M14-281
Status last verified
May 2024
First submitted
18 Sep 2014
Last updated
25 Jun 2024
Data monitoring committee
No
Individual data sharing
No

Publications

  • Bhananker SM, Posner KL, Cheney FW, Caplan RA, Lee LA, Domino KB. Injury and liability associated with monitored anesthesia care: a closed claims analysis. Anesthesiology. 2006 Feb;104(2):228-34. doi: 10.1097/00000542-200602000-00005.

    PubMed 16436839
  • Metzner J, Posner KL, Domino KB. The risk and safety of anesthesia at remote locations: the US closed claims analysis. Curr Opin Anaesthesiol. 2009 Aug;22(4):502-8. doi: 10.1097/ACO.0b013e32832dba50.

    PubMed 19506473
  • LaPierre CD, Johnson KB, Randall BR, White JL, Egan TD. An exploration of remifentanil-propofol combinations that lead to a loss of response to esophageal instrumentation, a loss of responsiveness, and/or onset of intolerable ventilatory depression. Anesth Analg. 2011 Sep;113(3):490-9. doi: 10.1213/ANE.0b013e318210fc45. Epub 2011 Mar 17.

    PubMed 21415430
  • Holley K, Mathews D, Freeman J, Brayanov J, Schapiro H. The Use of a Respiratory Volume Monitor to Assess Ventilation Before & After Airway Maneuvers during Upper Endoscopy. Poster Presentation, American Society of Anesthesiologists, October 2013, San Francisco, CA

  • Voscopoulos C, Brayanov J, Ladd D, Lalli M, Panasyuk A, Freeman J. Special article: evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios. Anesth Analg. 2013 Jul;117(1):91-100. doi: 10.1213/ANE.0b013e3182918098. Epub 2013 Jun 3.

    PubMed 23733842
  • Freeman J, Lalli M, Yocum N, Panasyuk A, Panasyuk S, and Lew R, 328: Non-invasive Monitoring of Tidal Volume and Minute Ventilation in Non-intubated Patients. Critical Care Medicine, 2011. 39(12): p. 88 10.1097/01.ccm.0000408627.24229.88.

Questions about this trial

What is this clinical trial studying?

A study testing ExSpiron Respiratory Variation Monitor in people with Biliary Tract Diseases and Stomach Neoplasms, run by Donald Mathews at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 25 Jun 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Average Minute Ventilation in Patients Cared for Using the ExSpiron Respiratory Variation Monitor (RVM) Compared to Patients With Routine Monitoring in Patients Undergoing Upper Gastrointestinal Endoscopy (time frame: Duration of procedure: Approximately 60 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02310230, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jun 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in