AzTrials
AzTrials

Pre EclampsiaNCT02319174

Accuracy Assessment of an Automatic Blood Pressure Measurement Device in Pregnant Women

A study testing Sphygmo in people with Pre Eclampsia, run by William Marsh Rice University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of the study is to help make a lower cost automatic blood pressure monitor device for diagnosis and monitoring of pre-eclampsia in pregnant women, where automatic blood pressure monitoring is limited or not available. Read more about this study

Who is it for?
Ages 18 years and older, women only
Conditions the study is for
Pre Eclampsia
What is being tested?
Sphygmo
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
43 participants
Where
1 siteUnited States
Study dates
Jun 2015to 4 Nov 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Pregnant women receiving antenatal care at the UT OB/GYN clinic.
  • Over the age of 18

Who cannot join

  • Women under the age of 18
  • Women unable to provide informed consent

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of Texas Health Science Center Houston

    Houston, Texas, 77030

Other trials in United States

About this study

The purpose of the study is to help make a lower cost automatic blood pressure monitor device for diagnosis and monitoring of pre-eclampsia in pregnant women, where automatic blood pressure monitoring is limited or not available. The study will compare this low cost device to a commercially available system used for pre-eclamptic women in many United States hospitals that the investigators will be bringing to Malawi as a part of this study.

The team hopes to show that this lower cost blood pressure machine works well and can help women with pre-eclampsia. The study also aims to see if this machine is easy for the nurse to use.

Read more

70 pregnant women who are either at-risk or diagnosed with pre-eclampsia will be enrolled at University of Texas Health Science Center Houston. Patient arm circumference will be measured with measurement tape.

They will be seated upright in a comfortable chair with arm at heart level and an arm blood pressure cuff from either the automatic blood pressure monitor or a manual sphygmomanometer will be placed on the left arm.

The cuff will be inflated and then deflated until measurement concludes. Heart rate will be measured with tactile arterial palpation.The process will be repeated for a total of up to nine measurements, alternating between measurements with the automatic blood pressure monitor and the manual sphygmomanometer. There will be a waiting period of 45-60 seconds between each measurement.

The results of this study will help researchers understand the performance and usability of this device in Malawi and help decide if any design changes are needed.

Read the detailed description

The research team has developed an automatic blood pressure monitor to be used for the monitoring and diagnosis of pre-eclampsia in pregnant women, particularly in low-resource settings where current monitoring is limited. This study aims to evaluate the accuracy of the device's blood pressure measurements in pregnant and pre-eclamptic women. This device must be evaluated with the above described population because blood pressure measurement devices are known to perform differently in pregnant and pre-eclamptic women than in normal healthy adults.

This study will take place at the University of Texas Health Science Center (UTHSC) where up to 70 subjects will be recruited to participate during their regularly scheduled antenatal care checkups.

  1. The Patient arm circumference will be measured with measurement tape.
  2. The Patient will be seated upright in a comfortable chair with arm at heart level.
  3. An arm blood pressure cuff from either the automatic blood pressure monitor or a manual sphygmomanometer will be placed on the left arm of the patient over the brachial artery.
  4. Cuff will be inflated to ~200 mmHg and then deflated until measurement concludes.
  5. Heart rate will be measured with Tactile Arterial Palpation.
  6. Steps 3-4 will be repeated for a total of up to nine measurements, alternating between measurements with the automatic blood pressure monitor and the manual sphygmomanometer. There will be a waiting period of 45-60 seconds between each measurement.
Conditions
Pre Eclampsia
Being tested
Sphygmo
Medical subject headings
Pre-Eclampsia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SphygmoDevice

    A team of engineers from Rice University has recently developed Sphygmo, an ambulatory, low-cost blood pressure monitor for use in the diagnosis and management of pre-eclampsia in low-resource hospitals

Study groups in NCT02319174
Study groupRoleWhat they receive
SphygmoExperimentalAll subjects will have blood pressure measured by both the research device (Sphygmo) and the commercially available device. All clinical decisions will be made using measurements from the commercially available device.
Receives: Device: Sphygmo

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Blood Pressure Readings by Sphygmo

    Mean difference of systolic and diastolic blood pressures between Sphygmo blood pressure measurements and measurements from the gold standard sphygmomanometer.

    Measured: Blood pressure was measured an average of 9 times for each participant and the average of these measurements was recorded. Each measurement period lasted approximately 30-45 minutes

  2. Percent of Sphygmo Readings That Were Within 5mmHg, 10mmHg, and 15mmHg of the Readings by the Gold Standard Sphygmomanometer.

    The British Hypertension society defines a specific criteria for the accuracy of a sphygmomanometer. Devices are graded according to the cumulative percentage of readings that have an absolute difference between the more favorable observer's mercury sphygmomanometer readings and the test device of < 5 mmHg, < 10 mmHg, and < 15 mmHg. A letter grade of "A" requires that over 60%, 85%, and 95% were achieved in the < 5 mmHg, < 10 mmHg, and <15 mmHg categories, respectively. A letter grade of "B" requires that over 50%, 75%, and 90% were achieved in the < 5 mmHg, < 10 mmHg, and <15 mmHg categories, respectively. The test device achieved a grade of (A/A) with the validation data from this study.

    Measured: Blood pressure was measured an average of 9 times for each participant during their single measurement period, and the average of those measurements was recorded. Each measurement period lasted approximately 30-45 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Dec 2014 (estimated)
  2. Study startJun 2015
  3. Primary completionJun 2015
  4. Study completion4 Nov 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
43 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02319174
Sponsor's protocol ID
14-082F-B
Status last verified
Dec 2018
First submitted
10 Dec 2014
Last updated
19 Dec 2018
Data monitoring committee
No

Publications

  • Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet Gynecol. 1999 Nov;181(5 Pt 1):1203-10. doi: 10.1016/s0002-9378(99)70109-2.

    PubMed 10561646
  • Turner JA. Diagnosis and management of pre-eclampsia: an update. Int J Womens Health. 2010 Sep 30;2:327-37. doi: 10.2147/IJWH.S8550.

    PubMed 21151680
  • Dekker G, Sibai B. Primary, secondary, and tertiary prevention of pre-eclampsia. Lancet. 2001 Jan 20;357(9251):209-15. doi: 10.1016/S0140-6736(00)03599-6.

    PubMed 11213110
  • Magee LA, Abalos E, von Dadelszen P, Sibai B, Easterling T, Walkinshaw S; CHIPS Study Group. How to manage hypertension in pregnancy effectively. Br J Clin Pharmacol. 2011 Sep;72(3):394-401. doi: 10.1111/j.1365-2125.2011.04002.x.

    PubMed 21545480
  • De Greeff A, Ghosh D, Anthony J, Shennan A. Accuracy assessment of the Dinamap ProCare 400 in pregnancy and preeclampsia. Hypertens Pregnancy. 2010 Jan;29(2):198-205. doi: 10.3109/10641950902968650.

    PubMed 20367507
  • O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, Altman DG, Bland M, Coats A, Atkins N. An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993 Jun;11(6):677-9. doi: 10.1097/00004872-199306000-00013. No abstract available.

    PubMed 8397248

Questions about this trial

What is this clinical trial studying?

A study testing Sphygmo in people with Pre Eclampsia, run by William Marsh Rice University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 19 Dec 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Blood Pressure Readings by Sphygmo (time frame: Blood pressure was measured an average of 9 times for each participant and the average of these measurements was recorded. Each measurement period lasted approximately 30-45 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02319174, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Dec 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in