Congestive Heart FailureElectroCRTNCT02346097
Electrophysiological Optimization of Left Ventricular Lead Placement in CRT
A study testing Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead) in people with Congestive Heart Failure, run by University of Aarhus at 1 site in Denmark.
Trial summary
The purpose of this study is to investigate if "optimal electrical resynchronization" achieved by targeting left ventricular lead placement to the myocardial region with the latest electrical activation combined with post-implant pacemakersettings for narrowing the paced QRS width causes an excess improvement in the… Read more about this study
- Who is it for?
- Ages 40 years and older
- Conditions the study is for
- Congestive Heart Failure
- What is being tested?
- Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 122 participants
- Where
- 1 siteDenmark
- Study dates
- 16 Feb 2015to 7 Jun 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 40 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Symptomatic heart failure (New York Heart Association (NYHA) functional class II - IV) despite optimal medical therapy
- ECG with left bundle branch block and QRS ≥ 120 ms
- LVEF ≤ 35 %
- Age > 40 years
- Written informed consent Patients with an indwelling single- or dual chamber pacemaker and a paced QRS > 180 ms are eligible for enrollment.
Who cannot join
- Expected lifetime < 6 months
- Expected heart-surgery within the next 6 months
- Recent (< 3 months) myocardial infarction or coronary artery bypass graft (CABG)
- Pregnant or lactating
- No written informed consent Cardiac CT will not be performed in patients where this is contraindicated, i.e. in the presence of depressed renal function (estimated Glomerular Filtration Rate (eGFR) < 30 ml (milliters)/minute), thyrotoxicosis or in the case of former serious reactions to the contrast media.
Trial locations and contacts
1 site in 1 country.
Denmark1 site
Aarhus University Hospital, Skejby, Department of Cardiology
Aarhus, 8200
About this study
Official title: ElectroCRT - Left Ventricular Lead Implant and Optimization Guided by Electrocardiography in Cardiac Resynchronization Therapy
The purpose of this study is to investigate if "optimal electrical resynchronization" achieved by targeting left ventricular lead placement to the myocardial region with the latest electrical activation combined with post-implant pacemakersettings for narrowing the paced QRS width causes an excess improvement in the pumping function of the heart (the left ventricular ejection fraction) in Cardiac Resynchronization Therapy (CRT)
Read the detailed description
Background:
Cardiac resynchronization therapy (CRT) is an established therapy in patients with a left ventricular (LV) ejection fraction (EF) < 35 %, and an electrocardiogram (ECG) with prolonged QRS duration (1). The treatment is implemented by implanting a pacemaker with three pacing leads: One in the right atrium, one in the right ventricle (RV) and one in an epicardial vein through the coronary sinus, thereby establishing atrial-synchronized biventricular pacing to coordinate RV and LV contraction.
Despite the convincing effect of CRT on survival, symptoms, and LV function (2,3,4) as much as 30-40 % of the patients do not benefit clinically from the treatment, so-called non-responders (5,6). Annually around 600 CRT-systems are implanted in Denmark and about 3000 patients live with a CRT. The risk of complications associated with CRT-treatment is considerable (7), and a conservative estimate of the expenses for implanting a CRT-device is DKK 80.000. Consequently, the costs of CRT in non-responders are high, both for the patients and for the health economy.
Potential correctable reasons for non-response to CRT are non-optimal LV lead positioning and non-optimal pacemaker programming (5). At the Department of Cardiology, Aarhus University Hospital, Skejby, the clinical practice is to place the LV lead in the non-apical postero-lateral region aiming towards a myocardial segment with electrical activation occurring in the second half of the QRS complex in the surface ECG.
Retrospective studies have documented an improved response rate to CRT when the LV lead is placed in a myocardial region with late electrical activation and without scar tissue (8,9). Furthermore, lack of electrical resynchronization after CRT illustrated by unchanged or prolonged QRS duration is associated with poor clinical outcome (10) and programming the interventricular (VV) delay to obtain the narrowest QRS-complex has been suggested to increase CRT response rate (11,12).
A recent randomized controlled trial (ImagingCRT) conducted at our institution demonstrated that an imaging guided LV lead placement strategy targeting the latest mechanically activated myocardial segment (assessed by pre-implant echocardiography) and separate from scar tissue (determined by pre-implant myocardial scintigraphy) improves clinical response rate to CRT (data not yet published). This method has the potential to become routine clinical practice for LV lead placement at our institution.
Aim and hypothesis:
We aim to investigate if optimal electrical resynchronization achieved by targeting LV lead placement to the myocardial region with the latest electrical activation determined by systematic electrical mapping of all available epicardial veins combined with post-implant VV electrical optimization for narrowing the paced QRS width causes an excess improvement in LVEF after CRT.
We hypothesize that this will cause an excess increase in LVEF of 4 %, to an absolute increase in LVEF of 12 % as compared to an absolute increase in LVEF to 8 % using an imaging guided CRT-implantation strategy.
Methods:
All patients referred to CRT at Aarhus University Hospital, Skejby will be assessed for eligibility. Eligibility criteria and outcomes measures elsewhere at clinicaltrial.gov.
Study Course:
After written informed consent the patient will follow the study course as specified below.
The day before implantation of the CRT the following investigations are scheduled: Echocardiography (to asses LV function and dimensions), cardiac CT-scan (to localize all available epicardial veins), myocardial scintigraphy (82Rubidium positron emission tomography (Rb-PET)), to determine the extent and distribution of scar tissue and LVEF (13,14)), blood samples and clinical evaluation.
The patients are randomized to EITHER imgaging guided placement of the LV lead targeting the myocardial region with the latest mechanical activation and VV-interval settings programmed with simultaneous biventricular pacing (routine CRT-strategy arm) OR LV lead placement guided by procedural electrical mapping of all available cardiac veins targeting the myocardial region with the latest electrical activation combined with VV electrical optimization the day after implantation to achieve the narrowest paced QRS width (intervention arm).
The day after the implantation all patients undergo a high-pitch cardiac CT to verify LV lead position (15), pacemaker test, programming of VV-intervals and echocardiographic atrioventricular (AV) optimization.
One month after the implantation all patients have their pacemaker tested by a research nurse according to standard clinical practice.
Six months after CRT implantation the following investigations are repeated: Echocardiography, clinical evaluation, pacemaker test and blood samples. Rb-PET is also repeated to determine potential changes in myocardial perfusion and LVEF. Thereafter the patient will attend standard controls of the pacemaker every six month according to standard procedures.
Power Calculations and statistics:
We hypothesize that a CRT-strategy targeting optimal electrical resynchronization will result in an excess increase of 4 % in LVEF compared with the routine CRT-strategy, where an 8 % increase is expected. To identify this absolute increase in LVEF and to achieve a statistical power of 80 %, the study will need a sample size of 98 patients, given a standard deviation (SD) of 7 % in both groups, and a two-sided alpha value of 0.05. Furthermore, to achieve a statistical power of > 80 % with a margen of noninferiority of 20 % for the secondary endpoint of clinical non-response to CRT (assuming a 75 % clinical response rate in the control group) we will need a sample size of 116 patients (given a two-sided alpha value of 0.05 %). Taking into consideration an expected loss of follow-up in approximately 5 % of the patients, we will include 122 patients.
All analyses will be conducted according to the intention-to-treat principle. Differences between groups will be tested using Students t-test, when normality is demonstrated; otherwise a non-parametric test (Mann-Whitney) is used. Categorical variables will be analyzed by χ2 test. A two-sided P- value of <0.05 is considered significant.
Research Plan:
The Department of Cardiology, Aarhus University Hospital, have the capacity and equipment to conduct this trial. The group of investigators contributes with a deep and long-lasting experience in CRT-treatment and 150 de-novo CRT-devices are annually implanted at our institution. We plan to enroll the patients during a two and a half-year period. This study is planned to start in February 2015 as a PhD program for Charlotte Stephansen, MD. Charlotte Stephansen will be the prime investigator in charge of including the patients and she will perform all clinical evaluations and image acquisitions during the admission for CRT implantation and at the six month follow-up. She will also be in charge of analyzing data after study completion.
The results will be published in peer-reviewed international journals, and are expected to result in at least three papers. None of the investigators have any conflicts of interest to declare.
The study will be conducted according to the principles of the Helsinki Declaration II. The study will be approved by The Central Denmark Region Committees on Health Research Ethics, reported to the Danish Data Protection Agency, and registered on ClinicalTrials.gov.
Perspective:
No prospective randomized trials have previously investigated the effect of a CRT treatment-strategy targeting optimal electrical resynchronization achieved by guiding LV lead placement to the myocardial region with the latest electrical activation combined with post-implant VV electrical optimization for narrowing the paced QRS width.
It is expected that this method improves the response to CRT. The human and economic costs of CRT in non-responders are therefore expected to be reduced. If an excess increase in LVEF is achieved in this study, it will be possible to prevent and relieve invalidating symptoms and reduce mortality in selected heart failue patients in the future. The utility and potential benefits of participating in this study are expected to equalize the risks of exposure to ionizing radiation, possible side effects and inconvenience to the patient.
References:
Please refer to the reference chapter
- Conditions
- Congestive Heart Failure
- Being tested
- Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)
- Keywords
- Cardiac Resynchronization Therapy, Heart Failure, Ejection Fraction, Narrow, Pacemaker, Electrophysiology, Electrical activation mapping, Coronary Sinus, Mapping, QRS, QRS width, Pacing Interval, Left Ventricular Lead, Cardiac CT, Echocardiography, Myocardial Scintigraphy, 6 Minutes Walk Test, Imaging, Left ventricular ejection fraction, Epicardial veins
- Medical subject headings
- Heart Failure, Aortic Coarctation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)Device
Also called St. Jude Qaudripolar LV lead
Optimal electrical resynchronization vs. routine CRT strategy, imaging guided. For more details refer to ""Arm descriptions"
| Study group | Role | What they receive |
|---|---|---|
| Optimal electrical resynchronization | Experimental | Cardiac Resynchronization Therapy: LV lead implant according to electrical activation mapping of available epicardial veins to identify the latest electrical activated myocardial region. Post-implant interventricular (VV) electrical optimization for narrowing the paced QRS width. Post-implant standard pacemaker settings: Atrioventricular (AV) interval 100-130 ms and VV interval settings with simultaneous biventricular pacing.
Day 1 after implantation: ECG, AV-optimization guided by echocardiography, high-pitch cardiac CT to verify LV lead position.
Programming of the VV interval to obtain the narrowest QRS-width Receives: Device: Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead) |
| Routine CRT-strategy, imaging guided | Active comparator | Cardiac Resynchronization Therapy: LV lead implant guided by echocardiography and Rb-PET towards the latest mechanically activated myocardial segment and separate from scar. Post-implant VV electrical optimization for narrowing the paced QRS width. Standard pacemaker settings for both groups: AV-interval 100-130 ms and VV-interval settings with simultaneous biventricular pacing.
Day 1 after implantation: ECG, AV-optimization guided by echocardiography, high-pitch cardiac CT to verify LV lead position.
Continue standard interventricular pacing interval settings with simultaneous pacing in both ventricular leads. Receives: Device: Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in Left Ventricular Ejection Fraction (LVEF)
Change in LVEF determined by 2D echocardiography
Measured: The day before implantation and 6 months after implantation
Secondary outcomes (14)
All cause mortality
The patients will be asked to give permission to pass along information from their cardiovascular medical records to the primary investigator until three years after the six months follow-up evaluation
Measured: 6 months and until "3 years and 6 months" after implantation
Hospitalization for heart failure
The patients will be asked to give permission to pass along information from their cardiovascular medical records to the primary investigator until three years after the six months follow-up evaluation
Measured: 6 months and until "3 years and 6 months" after implantation
CRT-implant procedure time
During implatation procedure
Measured: The day of implantation
Procedural radiation exposure
During implantation procedure
Measured: The day of implantation
Perioperative and late complications
Procedural and retrospective. The patients will be asked to give permission to pass along information from their cardiovascular medical records to the primary investigator until three years after the six months follow-up evaluation
Measured: The day of implantation, 6 months and until "3 years and 6 months" after implantation
Changes in Quality of Life
Changes in Quality of Life Assessed by Minnesota Living With Heart Failure Questionnaire
Measured: The day before implantation and 6 months
Changes in New York Heart Association Functional Class
Changes in New York Heart Association Functional Class assesed by clinical evaluation
Measured: The day before implantation and 6 months
Changes in Six Minutes Walk Test
Measured: The day before implantation and 6 months
Changes in level of N-terminal prohormone of brain natriuretic peptide
Changes in level of N-terminal prohormone of brain natriuretic peptide blood sample
Measured: The day before implantation and 6 months
Changes in Left Ventricular End Systolic Volume
Changes in Left Ventricular End Systolic Volume assessed by 2D echocardiography and Rb-PET
Measured: The day before implantation and 6 months
Changes in Left Ventricular End Diastolic Volume
Changes in Left Ventricular End Diastolic Volume assessed by 2D echocardiography and Rb-PET
Measured: The day before implantation and 6 months
Changes in Electrode Parameters (pacing threshold, sensing value, impedance)
Changes in Electrode Parameters (pacing threshold, sensing value, impedance) assessed by pacemakertest
Measured: The day after implantation and at 1 and 6 months follow-up
Changes in Echocardiographic Dyssynchrony parameters
Determined by 2D echocardiography
Measured: The day before implantation and at 6 months follow-up
Clinical response to CRT at 6 months follow-up if the patient is: 1. Alive, and 2. Not hospitalized for heart failure, and 3. experience an improvement of NYHA Functional Class or > 10 % increase in 6MWT
The patients will be asked to give permission to pass along information from their cardiovascular medical records to the primary investigator until three years after the six months follow-up evaluation
Measured: At the 6 months follow-up.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Jan 2015 (estimated)
- Study start16 Feb 2015
- Primary completion7 Jun 2018
- Study completion7 Jun 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (16)Papers the sponsor has linked to this study.
- Other trials for Congestive Heart FailureStudies of the same condition, open and under way.
- More trials run by University of AarhusThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Quadruple blind
- Who is masked
- Participant, Care provider, Investigator, Outcomes assessor
- Enrolment
- 122 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Aarhus
- Sponsor type
- University, hospital or other
- Collaborators
- Aarhus University Hospital
- Responsible party
- Sponsor
- Investigators
- Jens Cosedis Nielsen, Professor, Study director, Aarhus University Hospital, Sekjby, Department of CardiologyMads Brix Kronborg, MD, PhD, Study director, Aarhus University Hospital, Sekjby, Department of CardiologyAnders Sommer Knudsen, MD, Study director, Aarhus University Hospital, Sekjby, Department of Cardiology
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02346097
- Sponsor's protocol ID
- Electro-1-CRT
- Acronym
- ElectroCRT
- Status last verified
- Jun 2018
- First submitted
- 12 Jan 2015
- Last updated
- 18 Jun 2018
- Results posted
- No
- Data monitoring committee
- Yes
Publications
European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013 Aug;15(8):1070-118. doi: 10.1093/europace/eut206. Epub 2013 Jun 24. No abstract available.
PubMed 23801827Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, Ellestad M, Trupp RJ, Underwood J, Pickering F, Truex C, McAtee P, Messenger J; MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002 Jun 13;346(24):1845-53. doi: 10.1056/NEJMoa013168.
PubMed 12063368Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM; Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004 May 20;350(21):2140-50. doi: 10.1056/NEJMoa032423.
PubMed 15152059Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, Tavazzi L; Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005 Apr 14;352(15):1539-49. doi: 10.1056/NEJMoa050496. Epub 2005 Mar 7.
PubMed 15753115Yu CM, Sanderson JE, Gorcsan J 3rd. Echocardiography, dyssynchrony, and the response to cardiac resynchronization therapy. Eur Heart J. 2010 Oct;31(19):2326-37. doi: 10.1093/eurheartj/ehq263. Epub 2010 Aug 13.
PubMed 20709721Kronborg MB, Mortensen PT, Kirkfeldt RE, Nielsen JC. Very long term follow-up of cardiac resynchronization therapy: clinical outcome and predictors of mortality. Eur J Heart Fail. 2008 Aug;10(8):796-801. doi: 10.1016/j.ejheart.2008.06.013. Epub 2008 Jul 10.
PubMed 18619900Kirkfeldt RE, Johansen JB, Nohr EA, Jorgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J. 2014 May;35(18):1186-94. doi: 10.1093/eurheartj/eht511. Epub 2013 Dec 17.
PubMed 24347317Gold MR, Birgersdotter-Green U, Singh JP, Ellenbogen KA, Yu Y, Meyer TE, Seth M, Tchou PJ. The relationship between ventricular electrical delay and left ventricular remodelling with cardiac resynchronization therapy. Eur Heart J. 2011 Oct;32(20):2516-24. doi: 10.1093/eurheartj/ehr329. Epub 2011 Aug 29.
PubMed 21875862Kandala J, Upadhyay GA, Altman RK, Parks KA, Orencole M, Mela T, Kevin Heist E, Singh JP. QRS morphology, left ventricular lead location, and clinical outcome in patients receiving cardiac resynchronization therapy. Eur Heart J. 2013 Aug;34(29):2252-62. doi: 10.1093/eurheartj/eht123. Epub 2013 Apr 9.
PubMed 23571836Kronborg MB, Nielsen JC, Mortensen PT. Electrocardiographic patterns and long-term clinical outcome in cardiac resynchronization therapy. Europace. 2010 Feb;12(2):216-22. doi: 10.1093/europace/eup364. Epub 2009 Nov 14.
PubMed 19915182Tamborero D, Vidal B, Tolosana JM, Sitges M, Berruezo A, Silva E, Castel M, Matas M, Arbelo E, Rios J, Villacastin J, Brugada J, Mont L. Electrocardiographic versus echocardiographic optimization of the interventricular pacing delay in patients undergoing cardiac resynchronization therapy. J Cardiovasc Electrophysiol. 2011 Oct;22(10):1129-34. doi: 10.1111/j.1540-8167.2011.02085.x. Epub 2011 Jun 2.
PubMed 21635609Tamborero D, Mont L, Sitges M, Silva E, Berruezo A, Vidal B, Delgado V, Tolosana JM, Godoy M, Castel A, Brugada J. Optimization of the interventricular delay in cardiac resynchronization therapy using the QRS width. Am J Cardiol. 2009 Nov 15;104(10):1407-12. doi: 10.1016/j.amjcard.2009.07.006.
PubMed 19892059Ypenburg C, Schalij MJ, Bleeker GB, Steendijk P, Boersma E, Dibbets-Schneider P, Stokkel MP, van der Wall EE, Bax JJ. Impact of viability and scar tissue on response to cardiac resynchronization therapy in ischaemic heart failure patients. Eur Heart J. 2007 Jan;28(1):33-41. doi: 10.1093/eurheartj/ehl379. Epub 2006 Nov 22.
PubMed 17121757Bravo PE, Chien D, Javadi M, Merrill J, Bengel FM. Reference ranges for LVEF and LV volumes from electrocardiographically gated 82Rb cardiac PET/CT using commercially available software. J Nucl Med. 2010 Jun;51(6):898-905. doi: 10.2967/jnumed.109.073858. Epub 2010 May 19.
PubMed 20484424Sommer A, Kronborg MB, Norgaard BL, Gerdes C, Mortensen PT, Nielsen JC. Left and right ventricular lead positions are imprecisely determined by fluoroscopy in cardiac resynchronization therapy: a comparison with cardiac computed tomography. Europace. 2014 Sep;16(9):1334-41. doi: 10.1093/europace/euu056. Epub 2014 Mar 30.
PubMed 24687965
Study at a glance
From the registry record, last updated by the sponsor on 18 Jun 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- ElectroCRT - Left Ventricular Lead Implant and Optimization Guided by Electrocardiography in Cardiac Resynchronization Therapy
- ClinicalTrials.gov ID
- NCT02346097
- Acronym / sponsor ID
- ElectroCRT / Electro-1-CRT
- Conditions
- Congestive Heart Failure
- Keywords
- Cardiac Resynchronization Therapy, Heart Failure, Ejection Fraction, Narrow, Pacemaker, Electrophysiology, Electrical activation mapping, Coronary Sinus
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 122 participants (actual)
- Lead sponsor
- University of AarhusUniversity, hospital or other
- Collaborators
- Aarhus University Hospital
- Study start
- 16 Feb 2015 (actual)
- Primary completion
- 7 Jun 2018 (actual)
- Study completion
- 7 Jun 2018 (actual)
- First posted
- 26 Jan 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to investigate if "optimal electrical resynchronization" achieved by targeting left ventricular lead placement to the myocardial region with the latest electrical activation combined with post-implant pacemakersettings for narrowing the paced QRS width causes an excess improvement in the pumping function of the heart (the left ventricular ejection fraction) in Cardiac Resynchronization Therapy (CRT)
Detailed description
Background:
Cardiac resynchronization therapy (CRT) is an established therapy in patients with a left ventricular (LV) ejection fraction (EF) < 35 %, and an electrocardiogram (ECG) with prolonged QRS duration (1). The treatment is implemented by implanting a pacemaker with three pacing leads: One in the right atrium, one in the right ventricle (RV) and one in an epicardial vein through the coronary sinus, thereby establishing atrial-synchronized biventricular pacing to coordinate RV and LV contraction.
Despite the convincing effect of CRT on survival, symptoms, and LV function (2,3,4) as much as 30-40 % of the patients do not benefit clinically from the treatment, so-called non-responders (5,6). Annually around 600 CRT-systems are implanted in Denmark and about 3000 patients live with a CRT. The risk of complications associated with CRT-treatment is considerable (7), and a conservative estimate of the expenses for implanting a CRT-device is DKK 80.000. Consequently, the costs of CRT in non-responders are high, both for the patients and for the health economy.
Potential correctable reasons for non-response to CRT are non-optimal LV lead positioning and non-optimal pacemaker programming (5). At the Department of Cardiology, Aarhus University Hospital, Skejby, the clinical practice is to place the LV lead in the non-apical postero-lateral region aiming towards a myocardial segment with electrical activation occurring in the second half of the QRS complex in the surface ECG.
Retrospective studies have documented an improved response rate to CRT when the LV lead is placed in a myocardial region with late electrical activation and without scar tissue (8,9). Furthermore, lack of electrical resynchronization after CRT illustrated by unchanged or prolonged QRS duration is associated with poor clinical outcome (10) and programming the interventricular (VV) delay to obtain the narrowest QRS-complex has been suggested to increase CRT response rate (11,12).
A recent randomized controlled trial (ImagingCRT) conducted at our institution demonstrated that an imaging guided LV lead placement strategy targeting the latest mechanically activated myocardial segment (assessed by pre-implant echocardiography) and separate from scar tissue (determined by pre-implant myocardial scintigraphy) improves clinical response rate to CRT (data not yet published). This method has the potential to become routine clinical practice for LV lead placement at our institution.
Aim and hypothesis:
We aim to investigate if optimal electrical resynchronization achieved by targeting LV lead placement to the myocardial region with the latest electrical activation determined by systematic electrical mapping of all available epicardial veins combined with post-implant VV electrical optimization for narrowing the paced QRS width causes an excess improvement in LVEF after CRT.
We hypothesize that this will cause an excess increase in LVEF of 4 %, to an absolute increase in LVEF of 12 % as compared to an absolute increase in LVEF to 8 % using an imaging guided CRT-implantation strategy.
Methods:
All patients referred to CRT at Aarhus University Hospital, Skejby will be assessed for eligibility. Eligibility criteria and outcomes measures elsewhere at clinicaltrial.gov.
Study Course:
After written informed consent the patient will follow the study course as specified below.
The day before implantation of the CRT the following investigations are scheduled: Echocardiography (to asses LV function and dimensions), cardiac CT-scan (to localize all available epicardial veins), myocardial scintigraphy (82Rubidium positron emission tomography (Rb-PET)), to determine the extent and distribution of scar tissue and LVEF (13,14)), blood samples and clinical evaluation.
The patients are randomized to EITHER imgaging guided placement of the LV lead targeting the myocardial region with the latest mechanical activation and VV-interval settings programmed with simultaneous biventricular pacing (routine CRT-strategy arm) OR LV lead placement guided by procedural electrical mapping of all available cardiac veins targeting the myocardial region with the latest electrical activation combined with VV electrical optimization the day after implantation to achieve the narrowest paced QRS width (intervention arm).
The day after the implantation all patients undergo a high-pitch cardiac CT to verify LV lead position (15), pacemaker test, programming of VV-intervals and echocardiographic atrioventricular (AV) optimization.
One month after the implantation all patients have their pacemaker tested by a research nurse according to standard clinical practice.
Six months after CRT implantation the following investigations are repeated: Echocardiography, clinical evaluation, pacemaker test and blood samples. Rb-PET is also repeated to determine potential changes in myocardial perfusion and LVEF. Thereafter the patient will attend standard controls of the pacemaker every six month according to standard procedures.
Power Calculations and statistics:
We hypothesize that a CRT-strategy targeting optimal electrical resynchronization will result in an excess increase of 4 % in LVEF compared with the routine CRT-strategy, where an 8 % increase is expected. To identify this absolute increase in LVEF and to achieve a statistical power of 80 %, the study will need a sample size of 98 patients, given a standard deviation (SD) of 7 % in both groups, and a two-sided alpha value of 0.05. Furthermore, to achieve a statistical power of > 80 % with a margen of noninferiority of 20 % for the secondary endpoint of clinical non-response to CRT (assuming a 75 % clinical response rate in the control group) we will need a sample size of 116 patients (given a two-sided alpha value of 0.05 %). Taking into consideration an expected loss of follow-up in approximately 5 % of the patients, we will include 122 patients.
All analyses will be conducted according to the intention-to-treat principle. Differences between groups will be tested using Students t-test, when normality is demonstrated; otherwise a non-parametric test (Mann-Whitney) is used. Categorical variables will be analyzed by χ2 test. A two-sided P- value of <0.05 is considered significant.
Research Plan:
The Department of Cardiology, Aarhus University Hospital, have the capacity and equipment to conduct this trial. The group of investigators contributes with a deep and long-lasting experience in CRT-treatment and 150 de-novo CRT-devices are annually implanted at our institution. We plan to enroll the patients during a two and a half-year period. This study is planned to start in February 2015 as a PhD program for Charlotte Stephansen, MD. Charlotte Stephansen will be the prime investigator in charge of including the patients and she will perform all clinical evaluations and image acquisitions during the admission for CRT implantation and at the six month follow-up. She will also be in charge of analyzing data after study completion.
The results will be published in peer-reviewed international journals, and are expected to result in at least three papers. None of the investigators have any conflicts of interest to declare.
The study will be conducted according to the principles of the Helsinki Declaration II. The study will be approved by The Central Denmark Region Committees on Health Research Ethics, reported to the Danish Data Protection Agency, and registered on ClinicalTrials.gov.
Perspective:
No prospective randomized trials have previously investigated the effect of a CRT treatment-strategy targeting optimal electrical resynchronization achieved by guiding LV lead placement to the myocardial region with the latest electrical activation combined with post-implant VV electrical optimization for narrowing the paced QRS width.
It is expected that this method improves the response to CRT. The human and economic costs of CRT in non-responders are therefore expected to be reduced. If an excess increase in LVEF is achieved in this study, it will be possible to prevent and relieve invalidating symptoms and reduce mortality in selected heart failue patients in the future. The utility and potential benefits of participating in this study are expected to equalize the risks of exposure to ionizing radiation, possible side effects and inconvenience to the patient.
References:
Please refer to the reference chapter
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Quadruple blind (participant, care provider, investigator, outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Optimal electrical resynchronization | Experimental | Device: Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)Cardiac Resynchronization Therapy: LV lead implant according to electrical activation mapping of available epicardial veins to identify the latest electrical activated myocardial region. Post-implant interventricular (VV) electrical optimization for narrowing the paced QRS width. Post-implant standard pacemaker settings: Atrioventricular (AV) interval 100-130 ms and VV interval settings with simultaneous biventricular pacing. Day 1 after implantation: ECG, AV-optimization guided by echocardiography, high-pitch cardiac CT to verify LV lead position. Programming of the VV interval to obtain the narrowest QRS-width |
| Routine CRT-strategy, imaging guided | Active comparator | Device: Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)Cardiac Resynchronization Therapy: LV lead implant guided by echocardiography and Rb-PET towards the latest mechanically activated myocardial segment and separate from scar. Post-implant VV electrical optimization for narrowing the paced QRS width. Standard pacemaker settings for both groups: AV-interval 100-130 ms and VV-interval settings with simultaneous biventricular pacing. Day 1 after implantation: ECG, AV-optimization guided by echocardiography, high-pitch cardiac CT to verify LV lead position. Continue standard interventricular pacing interval settings with simultaneous pacing in both ventricular leads. |
Who may qualify
- Ages
- 40 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Symptomatic heart failure (New York Heart Association (NYHA) functional class II - IV) despite optimal medical therapy
- ECG with left bundle branch block and QRS ≥ 120 ms
- LVEF ≤ 35 %
- Age > 40 years
- Written informed consent Patients with an indwelling single- or dual chamber pacemaker and a paced QRS > 180 ms are eligible for enrollment.
Key exclusion criteria (5 listed)
- Expected lifetime < 6 months
- Expected heart-surgery within the next 6 months
- Recent (< 3 months) myocardial infarction or coronary artery bypass graft (CABG)
- Pregnant or lactating
- No written informed consent Cardiac CT will not be performed in patients where this is contraindicated, i.e. in the presence of depressed renal function (estimated Glomerular Filtration Rate (eGFR) < 30 ml (milliters)/minute), thyrotoxicosis or in the case of former serious reactions to the contrast media.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead)Also: St. Jude Qaudripolar LV leadOptimal electrical resynchronization vs. routine CRT strategy, imaging guided. For more details refer to ""Arm descriptions" | Device | Optimal electrical resynchronization, Routine CRT-strategy, imaging guided |
Primary outcome
Change in Left Ventricular Ejection Fraction (LVEF)
Time frame: The day before implantation and 6 months after implantation
Change in LVEF determined by 2D echocardiography
14 secondary outcomes
All cause mortality
Time frame: 6 months and until "3 years and 6 months" after implantation
Hospitalization for heart failure
Time frame: 6 months and until "3 years and 6 months" after implantation
CRT-implant procedure time
Time frame: The day of implantation
Procedural radiation exposure
Time frame: The day of implantation
Perioperative and late complications
Time frame: The day of implantation, 6 months and until "3 years and 6 months" after implantation
Changes in Quality of Life
Time frame: The day before implantation and 6 months
Changes in New York Heart Association Functional Class
Time frame: The day before implantation and 6 months
Changes in Six Minutes Walk Test
Time frame: The day before implantation and 6 months
Changes in level of N-terminal prohormone of brain natriuretic peptide
Time frame: The day before implantation and 6 months
Changes in Left Ventricular End Systolic Volume
Time frame: The day before implantation and 6 months
Changes in Left Ventricular End Diastolic Volume
Time frame: The day before implantation and 6 months
Changes in Electrode Parameters (pacing threshold, sensing value, impedance)
Time frame: The day after implantation and at 1 and 6 months follow-up
Changes in Echocardiographic Dyssynchrony parameters
Time frame: The day before implantation and at 6 months follow-up
Clinical response to CRT at 6 months follow-up if the patient is: 1. Alive, and 2. Not hospitalized for heart failure, and 3. experience an improvement of NYHA Functional Class or > 10 % increase in 6MWT
Time frame: At the 6 months follow-up.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Jun 2018.
- Background: PubMed 23801827European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013 Aug;15(8):1070-118. doi: 10.1093/europace/eut206. Epub 2013 Jun 24. No abstract available.
- Background: PubMed 12063368Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, Ellestad M, Trupp RJ, Underwood J, Pickering F, Truex C, McAtee P, Messenger J; MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002 Jun 13;346(24):1845-53. doi: 10.1056/NEJMoa013168.
- Background: PubMed 15152059Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM; Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004 May 20;350(21):2140-50. doi: 10.1056/NEJMoa032423.
- Background: PubMed 15753115Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, Tavazzi L; Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005 Apr 14;352(15):1539-49. doi: 10.1056/NEJMoa050496. Epub 2005 Mar 7.
- Background: PubMed 20709721Yu CM, Sanderson JE, Gorcsan J 3rd. Echocardiography, dyssynchrony, and the response to cardiac resynchronization therapy. Eur Heart J. 2010 Oct;31(19):2326-37. doi: 10.1093/eurheartj/ehq263. Epub 2010 Aug 13.
- Background: PubMed 18619900Kronborg MB, Mortensen PT, Kirkfeldt RE, Nielsen JC. Very long term follow-up of cardiac resynchronization therapy: clinical outcome and predictors of mortality. Eur J Heart Fail. 2008 Aug;10(8):796-801. doi: 10.1016/j.ejheart.2008.06.013. Epub 2008 Jul 10.
- Background: PubMed 24347317Kirkfeldt RE, Johansen JB, Nohr EA, Jorgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J. 2014 May;35(18):1186-94. doi: 10.1093/eurheartj/eht511. Epub 2013 Dec 17.
- Background: PubMed 21875862Gold MR, Birgersdotter-Green U, Singh JP, Ellenbogen KA, Yu Y, Meyer TE, Seth M, Tchou PJ. The relationship between ventricular electrical delay and left ventricular remodelling with cardiac resynchronization therapy. Eur Heart J. 2011 Oct;32(20):2516-24. doi: 10.1093/eurheartj/ehr329. Epub 2011 Aug 29.
- Background: PubMed 23571836Kandala J, Upadhyay GA, Altman RK, Parks KA, Orencole M, Mela T, Kevin Heist E, Singh JP. QRS morphology, left ventricular lead location, and clinical outcome in patients receiving cardiac resynchronization therapy. Eur Heart J. 2013 Aug;34(29):2252-62. doi: 10.1093/eurheartj/eht123. Epub 2013 Apr 9.
- Background: PubMed 19915182Kronborg MB, Nielsen JC, Mortensen PT. Electrocardiographic patterns and long-term clinical outcome in cardiac resynchronization therapy. Europace. 2010 Feb;12(2):216-22. doi: 10.1093/europace/eup364. Epub 2009 Nov 14.
- Background: PubMed 21635609Tamborero D, Vidal B, Tolosana JM, Sitges M, Berruezo A, Silva E, Castel M, Matas M, Arbelo E, Rios J, Villacastin J, Brugada J, Mont L. Electrocardiographic versus echocardiographic optimization of the interventricular pacing delay in patients undergoing cardiac resynchronization therapy. J Cardiovasc Electrophysiol. 2011 Oct;22(10):1129-34. doi: 10.1111/j.1540-8167.2011.02085.x. Epub 2011 Jun 2.
- Background: PubMed 19892059Tamborero D, Mont L, Sitges M, Silva E, Berruezo A, Vidal B, Delgado V, Tolosana JM, Godoy M, Castel A, Brugada J. Optimization of the interventricular delay in cardiac resynchronization therapy using the QRS width. Am J Cardiol. 2009 Nov 15;104(10):1407-12. doi: 10.1016/j.amjcard.2009.07.006.
Related trials for Congestive Heart Failure
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Not yet recruitingPhase 2
A Study of Bimagrumab in Participants With HFpEF
Heart Failure, Diastolic, Diastolic Heart Failure
Recruiting
Evaluation of a French Hospital Discharge Therapeutic Education Program by Nurses for Heart Failure Patient (EduSor)
Heart Failure
Active, not recruiting
Assessment of Combined CCM and ICD Device in HFrEF
Heart Failure, Heart Failure With Reduced Ejection Fraction
Not yet recruiting
RELIEVE-HFrEF TRIAL: REducing Lung congestIon Symptoms Using the v-wavE Shunt in adVancEd Heart Failure With Reduced EF
Heart Failure and Reduced Ejection Fraction, Heart Failure Chronic
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jens Cosedis Nielsen, Professor study director
Aarhus University Hospital, Sekjby, Department of Cardiology
Mads Brix Kronborg, MD, PhD study director
Aarhus University Hospital, Sekjby, Department of Cardiology
Anders Sommer Knudsen, MD study director
Aarhus University Hospital, Sekjby, Department of Cardiology
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Cardiac Resynchronization Therapy (St. Jude Qaudripolar LV lead) in people with Congestive Heart Failure, run by University of Aarhus at 1 site in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 18 Jun 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in Left Ventricular Ejection Fraction (LVEF) (time frame: The day before implantation and 6 months after implantation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02346097, which also lists 16 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jun 2018.