PET-CT After Nellix Implantation

An observational study of Aortic Aneurysm and Endovascular Repair, run by Rijnstate Hospital at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To determine FDG uptake following uncomplicated EVAR using the Nellix endoprosthesis. Does uncomplicated EVAR using the nellix endoprosthesis result in increased FDG uptake and false positive PET imaging? Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Aneurysm, Endovascular Repair
What is being tested?
Nellix Endoprosthesis
Type of treatment
Medical device
How many people
10 participants
Where
1 siteNetherlands
Study dates
Jan 2015to 30 Aug 2016
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: Patients with abdominal aortic aneurysms eligible for EVAS with Nellix endoprosthesis.

Who may be able to join

  • Patients treated with Nellix endoprosthesis

Who cannot join

  • Diabetes Mellitus (Type 1 and type 2)
  • Current known inflammation or malignancy

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Rijnstate Ziekenhuis

    Arnhem, Gelderland, 6815AD

Other trials in Netherlands

About this study

Official title: Clinical Relevance of Positron Emission Tomography (PET) Imaging Following Endovascular Aneurysm Repair Using the Nellix Endoprosthesis

To determine FDG uptake following uncomplicated EVAR using the Nellix endoprosthesis. Does uncomplicated EVAR using the nellix endoprosthesis result in increased FDG uptake and false positive PET imaging?

Read the detailed description

One of the most devastating complications following endovascular aneurysm repair (EVAR) is infection of the used endoprosthesis. Because of the high mortality of secondary surgery following infection, patients with a possible endoprosthesis infection are treated using broadspectrum antibiotics during months, years or even life-long. Unfortunately, the diagnosis of an endoprosthesis infection is difficult and based upon clinical suspicion and non-specific symptoms (e.g. fever and weigth loss) only. Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is often used as a diagnostic tool to identify infection following EVAR. Like infection, sterile physiologic inflammation following EVAR is also associated with increased metabolism and FDG uptake. This could result in (false-)positive PET imaging resulting in diagnostic errors and antibiotic overuse.

The Nellix endoprosthesis is a relatively new device used for EVAR. In present literature there is no data on the degree of physiologic inflammation following implantation of a Nellix device and the value of postoperative FDG-PET imaging to detect infection is not known. This makes the diagnosis of infection following Nellix implantation extremely difficult. This pilot is designed to determine physiologic FDG uptake following uncomplicated EVAR using the Nellix endoprosthesis.

Being tested
Nellix Endoprosthesis
Medical subject headings
Aortic Aneurysm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Nellix EndoprosthesisDevice

    Implantation of Nellix

Study groups in NCT02349100
Study groupRoleWhat they receive
Treated groupPatient group treated with Nellix Endoprosthesis.
Receives: Device: Nellix Endoprosthesis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference in physiological FDG uptake following Nellix EVAS implantation in patients without known infections or malignancies as measured by standard uptake values (SUV)

    Comparing pre- and post-implantation FDG uptake with ROI set at the aneurysm and stent. Measured SUV from FDG emission will be compared and subtracted and the difference will be reported (in MBq/kg).

    Measured: 1 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Jan 2015 (estimated)
  2. Study startJan 2015
  3. Primary completion13 Jul 2016
  4. Study completion30 Aug 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Prospective
Enrolment
10 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02349100
Sponsor's protocol ID
1093
Status last verified
Apr 2017
First submitted
12 Jan 2015
Last updated
11 Apr 2017
Results posted
No
Data monitoring committee
No

Publications

  • Groot Jebbink E, van Den Ham LH, van Woudenberg BBJ, Slart RHJA, Zeebregts CJ, Rijnders TJM, Lardenoije JHP, Reijnen MMPJ. Physiological Appearance of Hybrid FDG-Positron Emission Tomography/Computed Tomography Imaging Following Uncomplicated Endovascular Aneurysm Sealing Using the Nellix Endoprosthesis. J Endovasc Ther. 2020 Jun;27(3):509-515. doi: 10.1177/1526602820913888. Epub 2020 Apr 15.

    PubMed 32295455

Questions about this trial

What is this clinical trial studying?

An observational study of Aortic Aneurysm and Endovascular Repair, run by Rijnstate Hospital at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference in physiological FDG uptake following Nellix EVAS implantation in patients without known infections or malignancies as measured by standard uptake values (SUV) (time frame: 1 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02349100, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2017.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
PET-CT After Nellix Implantation (NCT02349100) | AzTrials