Coronary Artery DiseaseNCT02351050
Sonolysis in Risk Reduction of Symptomatic and Silent Brain Infarctions During Coronary Stenting
A study testing Sonolysis in people with Coronary Artery Disease, run by University Hospital Ostrava at 1 site in Slovakia.
Trial summary
The aim of the project is to demonstrate a fibrinolytic effect of sonothrombolysis (continual transcranial Doppler monitoring) using 2 MHz diagnostic probe on the reduction of risk of brain infarctions due to the activation of endogenous fibrinolytic system during angioplasty and stenting of coronary arteries. Read more about this study
- Who is it for?
- Ages 35 to 90 years
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- Sonolysis
- Type of treatment
- Medical device
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 144 participants
- Where
- 1 siteSlovakia
- Study dates
- Apr 2015to Nov 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 35 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- age 35-90 years
- sufficient temporal bone window for TCD with detectable blood flow in MCA
- independent patient (modified Rankin score 0-2)
- informed consent signed by the patient
- coronary angioplasty and stenting will be performed as an elective procedure
Who cannot join
- contra-indication for MRI examination (pace-maker, implanted metal material, claustrophobia)
- emergent coronary angioplasty and stenting
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Sonolysis in Risk Reduction of Symptomatic and Silent Brain Infarctions During Coronary Stenting Due to Ultrasound Activation of Endogenous Fibrinolytic System Using Transcranial Doppler Monitoring
The aim of the project is to demonstrate a fibrinolytic effect of sonothrombolysis (continual transcranial Doppler monitoring) using 2 MHz diagnostic probe on the reduction of risk of brain infarctions due to the activation of endogenous fibrinolytic system during angioplasty and stenting of coronary arteries. 120 patients indicated for coronary angioplasty and stenting will be enrolled into the study in order to demonstrate a twenty-percent risk reduction of number and volume of brain infarctions detected using MRI examination 24 hours after cardiac endovascular treatment in 5% level of significance. Patients will be randomized - subgroup 1 will undergo a 40-240 minute non-diagnostic TCD monitoring during endovascular procedure, subgroup 2 will undergo interventions without TCD monitoring.
Confirmation of our hypothesis that sonothrombolysis is able to activate endogenous fibrinolytic system during coronary angioplasty and stenting with consecutive reduction of the number and volume of brain infarcts, can lead to the increase of the safety these patients. We can presume that up to 50% of patients indicated for endovasular heart treatment can be treated using these methods in the future.
Read the detailed description
AIM OF THE PROJECT The aim of the project is to demonstrate an effect of continual TCD monitoring using 2 MHz diagnostic probe with maximal diagnostic energy on the reduction of risk of brain microinfarctions due to the activation of endogenous fibrinolytic system and mechanical effect on emboli during coronary stenting.
HYPOTHESIS Sonothrombolysis lead to activation of fibrinolytic system in both healthy volunteers and acute stroke patients. In acute stroke patients, mechanical effect of sonothrombolysis is the second effect leading to acceleration of occluded artery recanalization. We hypothesize that combination of mechanical effect and activation of fibrinolytic system during sonothrombolysis (TCD monitoring) during coronary stenting will lead to recanalization of small arterial occlusions caused by microembolization during intervention. The result will be reduction of volume and the number of brain infarctions.
120 patients indicated for coronary stenting will be enrolled into the study in order to demonstrate a twenty-percent risk reduction of number and volume of brain infarctions detected using MRI examination 24 hours after procedure in 5% level of statistical significance. Patients will be randomized into 2 subgroups. Subgroup 1 will undergo non-diagnostic bilateral TCD monitoring during coronary stenting. Subgroup 2 will undergo coronary stenting without TCD monitoring.
PATIENTS AND METHODS Patients: 120 patients indicated for coronary angioplasty and stenting will be enrolled into the study during a 3-year period. All 120 patients will be randomized for standard coronary angioplasty and stenting and TCD monitored.
Clinical examinations: Physical and neurological examinations including evaluating of neurological impairment of neurological deficit in NIHSS scale, modified Rankin scale and cognitive testing (Mini Mental State Examination, Clock drawing test) will be performed before and 24 - 72 hours after coronary angioplasty and stenting.
Randomization: Randomization using computer generated random allocation will be used.
Sonothrombolysis: In patients randomized into sonothrombolysis subgroup, bilateral MCA segment in depth 55 mm will be monitored for 40 - 240 minutes using a diagnostic 2 MHz probe with maximal diagnostic energy. Non-diagnostic TCD monitoring will be performed without detection of microembolic signals or detection of changes in blood flow. The second (control) subgroup will undergo a standard coronary angioplasty and stenting without sonothrombolysis.
MRI protocol will consists of 4 sequences: 1. Localizer; 2. T2TSE; 3. FLAIR; 4. DWI. Sequences 1-3 will be applied in the same level, they will have the same slice thickness and the same cut number. The slice thickness comprises its own cut thickness (5 mm) + distant factor (30%). Standard number of slices is 19. Standard slice level is considered to be a modified level of skull base due to the minimalization of distant artifacts EPI sequence. T2TSE: TR=4000/TE=99/ETL=9, FOV 230, FOV ph. 75%, matrix 256x256. FLAIR: 8050/112/ETL=21/2 conc., FOV 230, FOV ph. 76,6%, matrix 256x151. EPI-DWI: 4200/139/EPI f.=96/6 av., FOV 230, FOV ph. 100%, phase enc. direction A-P, matrix 128x96 with interpolation, phase partial Fourier 6/8, Bw 1346 Hz/Px, echo spacing 0.83 ms, TA. Sequence called "trace" with three types of MR pictures in every slice: (a) T2*EPI b=0; (b) DWI b=500; (c) DWI b=1000. The fourth type of images automatically created an ADC map (in-line postprocessing). DWI show a middle (average) diffusivity of every point of examined brain tissue when b value is 500 and 1000. This sequence is applied in order to assess hemorrhage (T2*EPI) and monitor sites of reduced diffusion (DWI, b=500 and 1000). New infarctions will be evaluated in the all of brain territories.
Adverse effects: All adverse effects during 1 month after UM will be registered, especially all causes for new admissions to the hospital, worsening of neurological symptoms (>4 points in NIH stroke scale), brain edema, symptomatic and asymptomatic intracranial bleeding detected in control brain MRI.
Study protocol has been approved by the Ethics Committees in accordance with the principles and guidelines of the Declaration of Helsinki, 1975.
- Conditions
- Coronary Artery Disease
- Being tested
- Sonolysis, Sham procedure
- Keywords
- sonolysis, brain infarction, coronary angioplasty
- Medical subject headings
- Coronary Artery Disease, Brain Infarction
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
SonolysisDevice
Also called sonothrombolysis, sonothrombotripsy
continual transcranial Doppler monitoring of middle cerebral artery
Sham procedureOther
sham transcranial Doppler monitoring of middle cerebral artery
| Study group | Role | What they receive |
|---|---|---|
| Sonolysis | Experimental | continual transcranial Doppler monitoring with maximal intensity during endovascular procedure Receives: Device: Sonolysis |
| placebo | Placebo comparator | sham transcranial Doppler monitoring during endovascular procedure Receives: Other: Sham procedure |
What is being measured
The primary outcome is the main question the study is designed to answer.
New infarction
New brain infarction detected using magnetic resonance diffusion weighted images (MRI-DWI)
Measured: 24 hours after intervention
Secondary outcomes (5)
Cognitive functions changes, measured by ADAS, MMSE, Clock Drawing Test and Verbal Fluency Test
Cognitive decline measured by ADAS, MMSE, Clock Drawing Test and Verbal Fluency Test
Measured: 7 and 30 days after interventions
Large new infarction, infarction ≥0.5 mL detected using magnetic resonance diffusion weighted images (MRI-DWI)
New brain infarction ≥0.5 mL detected using magnetic resonance diffusion weighted images (MRI-DWI)
Measured: 24 hours after intervention
Volume of new brain infarction, detected using magnetic resonance diffusion weighted images (MRI-DWI)
Volume of new brain infarctions detected using magnetic resonance diffusion weighted images (MRI-DWI)
Measured: 24 hours after intervention
30-days morbidity and mortality
stroke, TIA, myocardial infarctions and death during 30 days after intervention
Measured: 30 days after intervention
Symptomatic intracerebral hemorrhage, detected using magnetic resonance (MRI)
Intracerebral hemorrhage with worsening of neurological status (≥ 4 points in NIHSS scale) detected using magnetic resonance (MRI)
Measured: 24 hours after intervention
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 Jan 2015 (estimated)
- Study startApr 2015
- Primary completionSep 2017
- Study completionNov 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 144 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital Ostrava
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- David Skoloudik, MD, Prof, Study chair, University Hospital Ostrava
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02351050
- Sponsor's protocol ID
- 13595
- Status last verified
- Mar 2018
- First submitted
- 23 Nov 2014
- Last updated
- 26 Mar 2018
- Results posted
- No
- Data monitoring committee
- Yes
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 26 Mar 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Sonolysis in Risk Reduction of Symptomatic and Silent Brain Infarctions During Coronary Stenting Due to Ultrasound Activation of Endogenous Fibrinolytic System Using Transcranial Doppler Monitoring
- ClinicalTrials.gov ID
- NCT02351050
- Acronym / sponsor ID
- 13595
- Conditions
- Coronary Artery Disease
- Keywords
- sonolysis, brain infarction, coronary angioplasty
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 144 participants (actual)
- Lead sponsor
- University Hospital OstravaUniversity, hospital or other
- Study start
- Apr 2015 (actual)
- Primary completion
- Sep 2017 (actual)
- Study completion
- Nov 2017 (actual)
- First posted
- 30 Jan 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of the project is to demonstrate a fibrinolytic effect of sonothrombolysis (continual transcranial Doppler monitoring) using 2 MHz diagnostic probe on the reduction of risk of brain infarctions due to the activation of endogenous fibrinolytic system during angioplasty and stenting of coronary arteries. 120 patients indicated for coronary angioplasty and stenting will be enrolled into the study in order to demonstrate a twenty-percent risk reduction of number and volume of brain infarctions detected using MRI examination 24 hours after cardiac endovascular treatment in 5% level of significance. Patients will be randomized - subgroup 1 will undergo a 40-240 minute non-diagnostic TCD monitoring during endovascular procedure, subgroup 2 will undergo interventions without TCD monitoring.
Confirmation of our hypothesis that sonothrombolysis is able to activate endogenous fibrinolytic system during coronary angioplasty and stenting with consecutive reduction of the number and volume of brain infarcts, can lead to the increase of the safety these patients. We can presume that up to 50% of patients indicated for endovasular heart treatment can be treated using these methods in the future.
Detailed description
AIM OF THE PROJECT The aim of the project is to demonstrate an effect of continual TCD monitoring using 2 MHz diagnostic probe with maximal diagnostic energy on the reduction of risk of brain microinfarctions due to the activation of endogenous fibrinolytic system and mechanical effect on emboli during coronary stenting.
HYPOTHESIS Sonothrombolysis lead to activation of fibrinolytic system in both healthy volunteers and acute stroke patients. In acute stroke patients, mechanical effect of sonothrombolysis is the second effect leading to acceleration of occluded artery recanalization. We hypothesize that combination of mechanical effect and activation of fibrinolytic system during sonothrombolysis (TCD monitoring) during coronary stenting will lead to recanalization of small arterial occlusions caused by microembolization during intervention. The result will be reduction of volume and the number of brain infarctions.
120 patients indicated for coronary stenting will be enrolled into the study in order to demonstrate a twenty-percent risk reduction of number and volume of brain infarctions detected using MRI examination 24 hours after procedure in 5% level of statistical significance. Patients will be randomized into 2 subgroups. Subgroup 1 will undergo non-diagnostic bilateral TCD monitoring during coronary stenting. Subgroup 2 will undergo coronary stenting without TCD monitoring.
PATIENTS AND METHODS Patients: 120 patients indicated for coronary angioplasty and stenting will be enrolled into the study during a 3-year period. All 120 patients will be randomized for standard coronary angioplasty and stenting and TCD monitored.
Clinical examinations: Physical and neurological examinations including evaluating of neurological impairment of neurological deficit in NIHSS scale, modified Rankin scale and cognitive testing (Mini Mental State Examination, Clock drawing test) will be performed before and 24 - 72 hours after coronary angioplasty and stenting.
Randomization: Randomization using computer generated random allocation will be used.
Sonothrombolysis: In patients randomized into sonothrombolysis subgroup, bilateral MCA segment in depth 55 mm will be monitored for 40 - 240 minutes using a diagnostic 2 MHz probe with maximal diagnostic energy. Non-diagnostic TCD monitoring will be performed without detection of microembolic signals or detection of changes in blood flow. The second (control) subgroup will undergo a standard coronary angioplasty and stenting without sonothrombolysis.
MRI protocol will consists of 4 sequences: 1. Localizer; 2. T2TSE; 3. FLAIR; 4. DWI. Sequences 1-3 will be applied in the same level, they will have the same slice thickness and the same cut number. The slice thickness comprises its own cut thickness (5 mm) + distant factor (30%). Standard number of slices is 19. Standard slice level is considered to be a modified level of skull base due to the minimalization of distant artifacts EPI sequence. T2TSE: TR=4000/TE=99/ETL=9, FOV 230, FOV ph. 75%, matrix 256x256. FLAIR: 8050/112/ETL=21/2 conc., FOV 230, FOV ph. 76,6%, matrix 256x151. EPI-DWI: 4200/139/EPI f.=96/6 av., FOV 230, FOV ph. 100%, phase enc. direction A-P, matrix 128x96 with interpolation, phase partial Fourier 6/8, Bw 1346 Hz/Px, echo spacing 0.83 ms, TA. Sequence called "trace" with three types of MR pictures in every slice: (a) T2*EPI b=0; (b) DWI b=500; (c) DWI b=1000. The fourth type of images automatically created an ADC map (in-line postprocessing). DWI show a middle (average) diffusivity of every point of examined brain tissue when b value is 500 and 1000. This sequence is applied in order to assess hemorrhage (T2*EPI) and monitor sites of reduced diffusion (DWI, b=500 and 1000). New infarctions will be evaluated in the all of brain territories.
Adverse effects: All adverse effects during 1 month after UM will be registered, especially all causes for new admissions to the hospital, worsening of neurological symptoms (>4 points in NIH stroke scale), brain edema, symptomatic and asymptomatic intracranial bleeding detected in control brain MRI.
Study protocol has been approved by the Ethics Committees in accordance with the principles and guidelines of the Declaration of Helsinki, 1975.
Study design
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Sonolysis | Experimental | Device: Sonolysiscontinual transcranial Doppler monitoring with maximal intensity during endovascular procedure |
| placebo | Placebo comparator | Other: Sham proceduresham transcranial Doppler monitoring during endovascular procedure |
Who may qualify
- Ages
- 35 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- age 35-90 years
- sufficient temporal bone window for TCD with detectable blood flow in MCA
- independent patient (modified Rankin score 0-2)
- informed consent signed by the patient
- coronary angioplasty and stenting will be performed as an elective procedure
Key exclusion criteria (2 listed)
- contra-indication for MRI examination (pace-maker, implanted metal material, claustrophobia)
- emergent coronary angioplasty and stenting
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| SonolysisAlso: sonothrombolysis, sonothrombotripsycontinual transcranial Doppler monitoring of middle cerebral artery | Device | Sonolysis |
| Sham proceduresham transcranial Doppler monitoring of middle cerebral artery | Other | placebo |
Primary outcome
New infarction
Time frame: 24 hours after intervention
New brain infarction detected using magnetic resonance diffusion weighted images (MRI-DWI)
5 secondary outcomes
Cognitive functions changes, measured by ADAS, MMSE, Clock Drawing Test and Verbal Fluency Test
Time frame: 7 and 30 days after interventions
Large new infarction, infarction ≥0.5 mL detected using magnetic resonance diffusion weighted images (MRI-DWI)
Time frame: 24 hours after intervention
Volume of new brain infarction, detected using magnetic resonance diffusion weighted images (MRI-DWI)
Time frame: 24 hours after intervention
30-days morbidity and mortality
Time frame: 30 days after intervention
Symptomatic intracerebral hemorrhage, detected using magnetic resonance (MRI)
Time frame: 24 hours after intervention
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 26 Mar 2018.
- Individual participant dataSharing planned: Undecided
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
David Skoloudik, MD, Prof study chair
University Hospital Ostrava
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Sonolysis in people with Coronary Artery Disease, run by University Hospital Ostrava at 1 site in Slovakia.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 26 Mar 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Slovakia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
New infarction (time frame: 24 hours after intervention). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Mar 2018.