Pulmonary CongestionNCT02364193
Thoracic Fluid Assessment by Contrast-enhanced Magnetic Resonance Imaging and Bioimpedance
A study testing MRI, Gd-CA and BIS ImpediMed™ SFB7 in people with Pulmonary Congestion, run by Catharina Ziekenhuis Eindhoven at 1 site in Netherlands.
Trial summary
Heart failure (HF) is a major health problem, which is characterized by reduced cardiac function leading to pulmonary congestion. Most episodes of acute HF requiring unplanned hospitalization are due to pulmonary congestion. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Pulmonary Congestion
- What is being tested?
- MRI, Gd-CA and BIS ImpediMed™ SFB7
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 14 participants
- Where
- 1 siteNetherlands
- Study dates
- Mar 2015to Jun 2015
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Age >18 years
- Informed consent.
- Body mass index between 18 and 25
Who cannot join
- End-stage renal or hepatic disease
- Pregnancy
- Mild or moderate renal insufficiency, (GFR<60 mL/min);
- Risk for developing nephrogenic systemic fibrosis;
- General contra-indications to magnetic resonance imaging
- Pro-inflammatory state, vascular endothelial dysfunction
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Thoracic Fluid Assessment by Dynamic Contrast-enhanced Magnetic Resonance Imaging and Bioimpedance Spectroscopy: An Explorative Study in Healthy Subjects
Heart failure (HF) is a major health problem, which is characterized by reduced cardiac function leading to pulmonary congestion. Most episodes of acute HF requiring unplanned hospitalization are due to pulmonary congestion. There is an urgent clinical need for quantitative, reproducible, minimally invasive, and noninvasive methods to assess thoracic fluid status. The potential value of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to this end has been suggested and demonstrated in-vitro. In this study the investigators aim to compare intra-thoracic fluid volume assessed by DCE- MRI using bolus kinetic parameters of the indicator dilution theory and bioimpedance spectroscopy (BIS).
Primary objectives: This study evaluates the correlation between change in BIS and change in bolus kinetic parameters in response to a fluid challenge.
Read more
Secondary objectives: The sensitivity of the bolus kinetic parameters to fluid challenges and the normal range DCE-MRI bolus kinetic parameters is evaluated in healthy subjects.
Study design: Prospective nonrandomized pilot study.
Study population: Healthy volunteers.
Intervention: The subjects will receive an intra-venous injection of gadolinium, a MRI contrast agent. External pressure will be applied by means of a leg-compression device in order to induce a rapid increase of the preload by blood auto-transfusion.
Main study parameters: Pulmonary transit time (PTT), skewness of the indicator dilution curve which is a measure of trans-pulmonary dilution, intrathoracic blood volume (ITBV), changes in bolus kinetic parameters, and thoracic impedance in response to fluid challenges. The correlation between changes in bolus kinetic parameters and thoracic impedance in response to fluid challenges.
Read the detailed description
HF is a major health problem that affects 6.5 million people in Europe and 200.000 in the Netherlands. HF is characterized by frequent and often costly hospitalizations. Most hospitalizations for acute heart failure are due to pulmonary congestion rather than low cardiac output syndrome. Congestion is one of the clinical targets for current therapeutic approaches. Therefore, the assessment of fluid status is crucial for diagnosis, management, stratification and follow-up of HF patients.
Existing HF diagnostic tools:
Congestion is usually assessed by clinical signs such as dyspnea, oedema, rales, and jugular venous distension. Semi-quantitative scores have been developed, which may be used to follow-up response to HF therapy. However, these scores offer limited added clinical value because of the lack of an acceptable reproducibility, specificity, and sensitivity.
Indicator dilution theory and bolus kinetic analysis:
Assessment of congestion is possible by kinetic analysis of a bolus of a suitable indicator. Circulation tests based on this principle are well-known techniques to diagnose cardiac failure. Lower cardiac output (CO) and large lung blood volumes result in prolongation of circulation times.
Using the indicator dilution theory, bolus kinetic analysis can provide absolute volume measurement. The volume between injection and detection site or between different detection sites can be obtained by multiplying the difference in mean transit time of the indicator between the two sites and the flow rate of the dilution system. Furthermore, in case the indicator leaks from a membrane during the dilution process, kinetic parameters such as skewness of the indicator dilution curve may indicate the status of the membrane. The method was in principle applied by radionuclide angiography. Main limitations were the burden for the patient due to the use of radioactive tracers and the limitation of the method to the vessels, as it was not applicable for a large blood pool such as the heart ventricles. Other indicators such as dyes or cold saline require central vessel catheterization, an invasive procedure that results in severe additional risks for the patient.
DCE-MRI allows minimally invasive measurement of indicator dilution curves, with the advantage of simultaneous sampling in the different heart chambers. DCE-MRI has been proposed and validated in-vitro for volume measurement. It is a minimally invasive procedure that may advantage from automated post-processing techniques.
A small dose of gadolinium (Gd-CA) is used to ensure the linearity between the obtained MRI signal and the concentration of Gd-CA, for the indicator dilution theory. This bolus is much smaller than normally used for standard MRI protocols, this minimizes the risk for Gd-CA associated complications.
Compared to similar approaches in magnetic resonance angiography, DCE-MRI provides single heart beat resolution. Short post-processing time is required to derive physiological parameters since automated image processing and fitting routines are available.
Most studies focus only on left ventricle (LV) enhancement curve. This neglects right ventricle (RV) enhancement curve dilution system and therefore the hemodynamic status of the injection site to RV circulatory tree. Most studies only focus on the interpeak distance. A model-based curve fitting approach leads to more accurate results, not limited to the imaging sampling rate; which may lead to further estimation of additional parameters, possibly related to the lung circulation and its extravasation.
Pulmonary transit time (PTT) measured by DCE-MRI has been shown to be a good measure of preload and the LV filling pressure. The PTT was prolonged and correlated with alternative indirect congestion measures. Extravascular lung water (EVLW) currently can be assessed by chest X-ray, invasive thermodilution, or ultrasound comets. DCE-MRI based bolus kinetic offers a potential method for quantification of EVLW since due to their molecular weight, Gd-CAs are known to extravasate from the pulmonary circulation.
Impedance-based measurements:
An alternative approach to quantify thoracic fluids relies on transthoracic impedance measurements. These measurements can be performed non-invasive and continuous, which makes this a potential interesting monitoring tool for clinical practice to follow the trend of fluid redistribution towards pulmonary congestion. Previous evidences have shown that a decrease in thoracic impedance anticipates the need for hospitalization in HF patients.
Bio-impedance spectroscopy (BIS) is multi-frequency spectroscopy impedance measurement technique. All impedance-based measurements are limited to changes in volume and therefore need individual calibration to produce accurate absolute volumes. Moreover, several patient related characteristics, such as adiposity, height, and lung characteristics can also alter impedance-derived parameters. Therefore, because of the resultant high inter and intra-subject variability, only relative changes over time are significant. Impedance has been shown to be sensitive to fluid displacement in response to postural manoeuvres.
DCE-MRI and BIS provide complementary information. A monitoring strategy based on MRI at baseline and consecutive follow-up with BIS would satisfy the requirements for a clinically useful measurement technique that allows to reliably monitor the transition towards cardiopulmonary congestion even before clinical signs are present.
Goal of the study:
In this study the investigators aim to investigate whether changes in intrathoracic volumes can reliably be quantified by DCE-MRI and BIS measurements. The investigators hypothesize that such change in thoracic fluid distribution induced by fluid challenges can be detected in a minimally invasive way by DCE-MRI and by BIS, with agreement between the results of the two measurement techniques.
- Conditions
- Pulmonary Congestion
- Being tested
- MRI, Gd-CA, BIS ImpediMed™ SFB7, Autotransfusion Lympamat Digital Gradient system
- Keywords
- Intrathoracic blood volume, Extravascular lung water
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
MRIDevice
Cardiac MRI for LVEF and segmentation.
- Phase-contrast MRI for CO in aorta and each pulmonary vein.
- DCE-MRI for bolus kinetic parameter analysis.
Gd-CADrug
Bolus kinetic parameter analysis, different doses of Gd-CA (Dotarem by Guerbet) ranging between 0.1 and 0.5 mmol will be injected intravenously after dilution in 5 milliliter saline by an injector at a speed of 5 ml/s.
BIS ImpediMed™ SFB7Device
BIS will be measured by Bio-impedance spectroscopy will be performed using ImpediMed™ SFB7 (ImpediMed Limited 2008).
Impedance will be measured continuously during the fluid challenge and for maximum 600 seconds before and after the fluid challenge.
Currents of different frequencies will be applied; the resulting voltage will be recorded, with a time resolution for the complete frequency span not lower than 2 seconds.
Autotransfusion Lympamat Digital Gradient systemDevice
Lympamat Digital Gradient system (Bosl, Aachen) inflatable leg compression trousers will induce an autotransfusion by compressing the legs with a maximum of 90 mmHg for a maximum of 300 seconds
| Study group | Role | What they receive |
|---|---|---|
| Thoracic fluid status assessment | Experimental | Cardiac MRI by a 1.5 Tesla scanner:
* Left ventricular ejection fraction (LVEF), tracing short axis endocardial borders.
* CO, phase contrast angiography.
* Fluid challenge by auto-transfusion by distal leg compression using inflatable cuffs (Lympamat Digital Gradient system).
* DCE-MRI, bolus injection of Gd-CA intravenously by an injector. Each subject will receive repeated injections (10% of maximum dose).
* BIS, impedance will be measured continuously using ImpediMed-SFB7 and surface electrodes on the thorax. . Receives: Device: MRI; Drug: Gd-CA; Device: BIS ImpediMed™ SFB7; Device: Autotransfusion Lympamat Digital Gradient system |
What is being measured
The primary outcome is the main question the study is designed to answer.
Bolus kinetic parameters using Contrast-enhanced-MRI and BIS
Correlation between changes in PTT and skewness of transpulmonary dilution system by DCE-MRI and changes in extravascular resistance measured by bio-impedance spectroscopy
Measured: 30 minutes
Secondary outcomes (3)
Fluid challenge response
Changes in PTT and skewness of transpulmonary dilution curve measured by DCE-MRI in response to fluid challenge/autotransfusion
Measured: 15 minutes
Bolus kinetic parameters (Optimal DCE-MRI imaging sequence and range of normal values for ITBV, PTT and skewness of transpulmonary circulation measured by DCE-MRI in healthy subjects)
Optimal DCE-MRI imaging sequence and range of normal values for ITBV, PTT and skewness of transpulmonary circulation measured by DCE-MRI in healthy subjects.
Measured: 5 minutes
Bolus kinetic parameters and hemodynamic parameters.
Correlation between ITBV, PTT and CMR functional parameters in volunteers by pearson correlation/linear regression- and Bland-Altman analyses. ITBV [milliliter] and PTT [seconds] will be correlated to the cardiac output [l/min], ejection fraction [%], and end-diastolic volume [ml] measured all by CMR.
Measured: 5 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Feb 2015 (estimated)
- Study startMar 2015
- Primary completionJun 2015
- Study completionJun 2015
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Pulmonary CongestionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 14 participants (actual)
Sponsor and investigators
- Lead sponsor
- Catharina Ziekenhuis Eindhoven
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Ingeborg Herold, Catharina Ziekenhuis Eindhoven
- Investigators
- Massimo Mischi, Msc PhD, Study director, Eindhoven University of Technology
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02364193
- Sponsor's protocol ID
- NL50327.060.14
- Status last verified
- Jan 2016
- First submitted
- 16 Jan 2015
- Last updated
- 28 Jan 2016
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 28 Jan 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Thoracic Fluid Assessment by Dynamic Contrast-enhanced Magnetic Resonance Imaging and Bioimpedance Spectroscopy: An Explorative Study in Healthy Subjects
- ClinicalTrials.gov ID
- NCT02364193
- Acronym / sponsor ID
- NL50327.060.14
- Conditions
- Pulmonary Congestion
- Keywords
- Intrathoracic blood volume, Extravascular lung water
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 14 participants (actual)
- Lead sponsor
- Catharina Ziekenhuis EindhovenUniversity, hospital or other
- Study start
- Mar 2015
- Primary completion
- Jun 2015 (actual)
- Study completion
- Jun 2015 (actual)
- First posted
- 18 Feb 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Heart failure (HF) is a major health problem, which is characterized by reduced cardiac function leading to pulmonary congestion. Most episodes of acute HF requiring unplanned hospitalization are due to pulmonary congestion. There is an urgent clinical need for quantitative, reproducible, minimally invasive, and noninvasive methods to assess thoracic fluid status. The potential value of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to this end has been suggested and demonstrated in-vitro. In this study the investigators aim to compare intra-thoracic fluid volume assessed by DCE- MRI using bolus kinetic parameters of the indicator dilution theory and bioimpedance spectroscopy (BIS).
Primary objectives: This study evaluates the correlation between change in BIS and change in bolus kinetic parameters in response to a fluid challenge.
Secondary objectives: The sensitivity of the bolus kinetic parameters to fluid challenges and the normal range DCE-MRI bolus kinetic parameters is evaluated in healthy subjects.
Study design: Prospective nonrandomized pilot study.
Study population: Healthy volunteers.
Intervention: The subjects will receive an intra-venous injection of gadolinium, a MRI contrast agent. External pressure will be applied by means of a leg-compression device in order to induce a rapid increase of the preload by blood auto-transfusion.
Main study parameters: Pulmonary transit time (PTT), skewness of the indicator dilution curve which is a measure of trans-pulmonary dilution, intrathoracic blood volume (ITBV), changes in bolus kinetic parameters, and thoracic impedance in response to fluid challenges. The correlation between changes in bolus kinetic parameters and thoracic impedance in response to fluid challenges.
Detailed description
HF is a major health problem that affects 6.5 million people in Europe and 200.000 in the Netherlands. HF is characterized by frequent and often costly hospitalizations. Most hospitalizations for acute heart failure are due to pulmonary congestion rather than low cardiac output syndrome. Congestion is one of the clinical targets for current therapeutic approaches. Therefore, the assessment of fluid status is crucial for diagnosis, management, stratification and follow-up of HF patients.
Existing HF diagnostic tools:
Congestion is usually assessed by clinical signs such as dyspnea, oedema, rales, and jugular venous distension. Semi-quantitative scores have been developed, which may be used to follow-up response to HF therapy. However, these scores offer limited added clinical value because of the lack of an acceptable reproducibility, specificity, and sensitivity.
Indicator dilution theory and bolus kinetic analysis:
Assessment of congestion is possible by kinetic analysis of a bolus of a suitable indicator. Circulation tests based on this principle are well-known techniques to diagnose cardiac failure. Lower cardiac output (CO) and large lung blood volumes result in prolongation of circulation times.
Using the indicator dilution theory, bolus kinetic analysis can provide absolute volume measurement. The volume between injection and detection site or between different detection sites can be obtained by multiplying the difference in mean transit time of the indicator between the two sites and the flow rate of the dilution system. Furthermore, in case the indicator leaks from a membrane during the dilution process, kinetic parameters such as skewness of the indicator dilution curve may indicate the status of the membrane. The method was in principle applied by radionuclide angiography. Main limitations were the burden for the patient due to the use of radioactive tracers and the limitation of the method to the vessels, as it was not applicable for a large blood pool such as the heart ventricles. Other indicators such as dyes or cold saline require central vessel catheterization, an invasive procedure that results in severe additional risks for the patient.
DCE-MRI allows minimally invasive measurement of indicator dilution curves, with the advantage of simultaneous sampling in the different heart chambers. DCE-MRI has been proposed and validated in-vitro for volume measurement. It is a minimally invasive procedure that may advantage from automated post-processing techniques.
A small dose of gadolinium (Gd-CA) is used to ensure the linearity between the obtained MRI signal and the concentration of Gd-CA, for the indicator dilution theory. This bolus is much smaller than normally used for standard MRI protocols, this minimizes the risk for Gd-CA associated complications.
Compared to similar approaches in magnetic resonance angiography, DCE-MRI provides single heart beat resolution. Short post-processing time is required to derive physiological parameters since automated image processing and fitting routines are available.
Most studies focus only on left ventricle (LV) enhancement curve. This neglects right ventricle (RV) enhancement curve dilution system and therefore the hemodynamic status of the injection site to RV circulatory tree. Most studies only focus on the interpeak distance. A model-based curve fitting approach leads to more accurate results, not limited to the imaging sampling rate; which may lead to further estimation of additional parameters, possibly related to the lung circulation and its extravasation.
Pulmonary transit time (PTT) measured by DCE-MRI has been shown to be a good measure of preload and the LV filling pressure. The PTT was prolonged and correlated with alternative indirect congestion measures. Extravascular lung water (EVLW) currently can be assessed by chest X-ray, invasive thermodilution, or ultrasound comets. DCE-MRI based bolus kinetic offers a potential method for quantification of EVLW since due to their molecular weight, Gd-CAs are known to extravasate from the pulmonary circulation.
Impedance-based measurements:
An alternative approach to quantify thoracic fluids relies on transthoracic impedance measurements. These measurements can be performed non-invasive and continuous, which makes this a potential interesting monitoring tool for clinical practice to follow the trend of fluid redistribution towards pulmonary congestion. Previous evidences have shown that a decrease in thoracic impedance anticipates the need for hospitalization in HF patients.
Bio-impedance spectroscopy (BIS) is multi-frequency spectroscopy impedance measurement technique. All impedance-based measurements are limited to changes in volume and therefore need individual calibration to produce accurate absolute volumes. Moreover, several patient related characteristics, such as adiposity, height, and lung characteristics can also alter impedance-derived parameters. Therefore, because of the resultant high inter and intra-subject variability, only relative changes over time are significant. Impedance has been shown to be sensitive to fluid displacement in response to postural manoeuvres.
DCE-MRI and BIS provide complementary information. A monitoring strategy based on MRI at baseline and consecutive follow-up with BIS would satisfy the requirements for a clinically useful measurement technique that allows to reliably monitor the transition towards cardiopulmonary congestion even before clinical signs are present.
Goal of the study:
In this study the investigators aim to investigate whether changes in intrathoracic volumes can reliably be quantified by DCE-MRI and BIS measurements. The investigators hypothesize that such change in thoracic fluid distribution induced by fluid challenges can be detected in a minimally invasive way by DCE-MRI and by BIS, with agreement between the results of the two measurement techniques.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Thoracic fluid status assessment | Experimental | Device: MRI, Drug: Gd-CA, Device: BIS ImpediMed™ SFB7, Device: Autotransfusion Lympamat Digital Gradient systemCardiac MRI by a 1.5 Tesla scanner: * Left ventricular ejection fraction (LVEF), tracing short axis endocardial borders. * CO, phase contrast angiography. * Fluid challenge by auto-transfusion by distal leg compression using inflatable cuffs (Lympamat Digital Gradient system). * DCE-MRI, bolus injection of Gd-CA intravenously by an injector. Each subject will receive repeated injections (10% of maximum dose). * BIS, impedance will be measured continuously using ImpediMed-SFB7 and surface electrodes on the thorax. . |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Age >18 years
- Informed consent.
- Body mass index between 18 and 25
Key exclusion criteria (6 listed)
- End-stage renal or hepatic disease
- Pregnancy
- Mild or moderate renal insufficiency, (GFR<60 mL/min);
- Risk for developing nephrogenic systemic fibrosis;
- General contra-indications to magnetic resonance imaging
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| MRICardiac MRI for LVEF and segmentation. * Phase-contrast MRI for CO in aorta and each pulmonary vein. * DCE-MRI for bolus kinetic parameter analysis. | Device | Thoracic fluid status assessment |
| Gd-CABolus kinetic parameter analysis, different doses of Gd-CA (Dotarem by Guerbet) ranging between 0.1 and 0.5 mmol will be injected intravenously after dilution in 5 milliliter saline by an injector at a speed of 5 ml/s. | Drug | Thoracic fluid status assessment |
| BIS ImpediMed™ SFB7BIS will be measured by Bio-impedance spectroscopy will be performed using ImpediMed™ SFB7 (ImpediMed Limited 2008). Impedance will be measured continuously during the fluid challenge and for maximum 600 seconds before and after the fluid challenge. Currents of different frequencies will be applied; the resulting voltage will be recorded, with a time resolution for the complete frequency span not lower than 2 seconds. | Device | Thoracic fluid status assessment |
| Autotransfusion Lympamat Digital Gradient systemLympamat Digital Gradient system (Bosl, Aachen) inflatable leg compression trousers will induce an autotransfusion by compressing the legs with a maximum of 90 mmHg for a maximum of 300 seconds | Device | Thoracic fluid status assessment |
Primary outcome
Bolus kinetic parameters using Contrast-enhanced-MRI and BIS
Time frame: 30 minutes
Correlation between changes in PTT and skewness of transpulmonary dilution system by DCE-MRI and changes in extravascular resistance measured by bio-impedance spectroscopy
3 secondary outcomes
Fluid challenge response
Time frame: 15 minutes
Bolus kinetic parameters (Optimal DCE-MRI imaging sequence and range of normal values for ITBV, PTT and skewness of transpulmonary circulation measured by DCE-MRI in healthy subjects)
Time frame: 5 minutes
Bolus kinetic parameters and hemodynamic parameters.
Time frame: 5 minutes
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Jan 2016.
Related trials for Pulmonary Congestion
Not yet recruiting
RELIEVE-HFrEF TRIAL: REducing Lung congestIon Symptoms Using the v-wavE Shunt in adVancEd Heart Failure With Reduced EF
Heart Failure and Reduced Ejection Fraction, Heart Failure Chronic
RecruitingPhase 4
DECONGEST-AHF: Vasodilatation or Loop Diuretics in Acute Heart Failure
Pulmonary Edema, Congestive Heart Failure
RecruitingObservational study
Association Between Changes in Aortic Valve Area and Pulmonary Congestion After Transcatheter Aortic Valve Implantation
Aortic Stenosis
RecruitingObservational study
Congestion and LActate at diScHarge in Acute Heart Failure
Heart Failure Acute, Discharge Follow-up Phone Calls
Not yet recruitingObservational study
Relationship Between the Level of Positive End-expiratory Pressure and Venous Congestion During Acute Respiratory Distress Syndrome.
Mechanical Ventilation, Acute Respiratory Distress Syndrome (ARDS)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Massimo Mischi, Msc PhD study director
Eindhoven University of Technology
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing MRI, Gd-CA and BIS ImpediMed™ SFB7 in people with Pulmonary Congestion, run by Catharina Ziekenhuis Eindhoven at 1 site in Netherlands.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 28 Jan 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Bolus kinetic parameters using Contrast-enhanced-MRI and BIS (time frame: 30 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jan 2016.