AzTrials
AzTrials

Respiratory Distress SyndromeNCT02392806

Comparative Effectiveness Study of Bubble CPAP Devices in the NICU

A study testing Bubble CPAP- BabiPlus, Respiralogics and Bubble CPAP- B&B Bubbler, B&B Medical devices in people with Respiratory Distress Syndrome, run by Marya Strand, MD at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Multiple different devices are available to provide Bubble CPAP to preterm and newborn infants. The most significant difference between these devices is the size of the bubble produced by the exhalation limb. Read more about this study

Who is it for?
Ages 1 day to 100 days
Conditions the study is for
Respiratory Distress Syndrome
What is being tested?
Bubble CPAP- BabiPlus, Respiralogics and Bubble CPAP- B&B Bubbler, B&B Medical devices
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
43 participants
Where
1 siteUnited States
Study dates
Jan 2015to Aug 2016
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 day to 100 days
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Infant delivered at >=500 grams and <=1250 grams birth weight.
  • Infant requires intubation for mechanical ventilation within the first 48 hours following delivery.
  • Infant has received exogenous surfactant during mechanical ventilation.

Who cannot join

  • Decision by attending physician to redirect to comfort care
  • Congenital condition that precludes the use of CPAP (choanal atresia, diaphragmatic hernia, etc.)
  • Birth weight >1250 grams or <500 grams.
  • Non-English speaking parents. -

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Cardinal Glennon Children's Hospital

    St Louis, Missouri, 63104

Other trials in United States

About this study

Multiple different devices are available to provide Bubble CPAP to preterm and newborn infants. The most significant difference between these devices is the size of the bubble produced by the exhalation limb. This study will determine if one Bubble CPAP device (BabiPlus vs B\&B) is more effective in improving oxygenation and decreasing extubation failure in the extremely low birthweight population.

Read the detailed description

Primary outcome: Bubble CPAP failure (re-intubation or use of non-invasive positive pressure ventilation) within 72 hours following extubation Secondary outcome: Number of infants that reach 21% inspired oxygen during initial study period Secondary outcome: Apnea/bradycardia events in the initial study period Secondary outcome: Mean oxygen requirement following initial study period

Population: Infants born at <=1250 grams birth weight but >= 500 grams birth weight

Randomization: Equal allocation stratified by gestational age (<27 weeks, >=27 weeks)

Study diagram:

72h 24h X---------->X1----------->Y2 Y---------->Y1----------->X2 Infants will be randomly assigned to treatment X (BabiPlus, control group) or treatment Y (B\&B Bubbler, intervention group). The primary outcome is bubble CPAP failure during the first 72 hours following extubation, measured at time point 1 in the diagram. Bubble CPAP failure is defined as requiring re-intubation or non-invasive positive pressure ventilation (NIPPV), requiring FiO2 of >60% for one hour or a pCO2 measurement of >65 mm Hg. For those infants that remain on CPAP during the initial study period, the number that reach 21% inspired oxygen for >12 consecutive hours will be compared between groups. This difference will also be analyzed using a Chi square test.

Those infants that remain on CPAP following the 72 hour initial study period (e.g., did not meet primary outcome criteria) will be crossed over to the opposite treatment arm for at least 24 hours. The minimum oxygen requirement required to keep the saturations in the ordered range, per standard NICU guidelines, will be recorded and compared between time points 1 and 2.

This study design is complex due to the nature of the disease of these patients. Each day every infant's premature pulmonary disease is evolving. There is no way to control for this.

Being tested
Bubble CPAP- BabiPlus, Respiralogics, Bubble CPAP- B&B Bubbler, B&B Medical devices
Keywords
Continuous positive airway pressure, CPAP, Bubble CPAP, Extubation failure, Preterm infant
Medical subject headings
Respiratory Distress Syndrome, Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Bubble CPAP- BabiPlus, RespiralogicsDevice

    Also called Bubble Continuous Positive Airway Pressure (BCPAP)

    Infant will be randomized to BabiPlus Bubbler at time of extubation

  • Bubble CPAP- B&B Bubbler, B&B Medical devicesDevice

    Infant will be randomized to B\&B Bubbler at time of extubation

Study groups in NCT02392806
Study groupRoleWhat they receive
BabiPlus, RespiralogicsActive comparatorInfants randomized to the BabiPlus device will be extubated to BabiPlus Bubble CPAP device and after 72 hours, if the infant has remained extubated, will be crossed-over to the B\&B Bubbler device for 24 hours
Receives: Device: Bubble CPAP- BabiPlus, Respiralogics
B&B Bubbler, B&B medical TechnologiesActive comparatorInfants randomized to the B\&B Bubbler device will be extubated to B\&B Bubbler Bubble CPAP device and after 72 hours, if the infant has remained extubated, will be crossed-over to the BabiPlus device for 24 hours
Receives: Device: Bubble CPAP- B&B Bubbler, B&B Medical devices

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Extubation Failure

    Bubble CPAP failure (re-intubation or use of non-invasive positive pressure ventilation) within 72 hours following extubation

    Measured: Within 72 hours of extubation

Secondary outcomes (1)
  1. Oxygenation - Oxygen Saturation Via Pulse Oximetry Recorded Hourly

    Number of infants that reach 21% inspired oxygen during initial study period of 72 hours plus the crossover period of 24 hours

    Measured: 96 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Mar 2015 (estimated)
  2. Study startJan 2015
  3. Primary completionAug 2016
  4. Study completionAug 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
43 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02392806
Sponsor's protocol ID
SLU Protocol # 24949
Status last verified
Feb 2018
First submitted
27 Feb 2015
Last updated
9 Mar 2018
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Bubble CPAP- BabiPlus, Respiralogics and Bubble CPAP- B&B Bubbler, B&B Medical devices in people with Respiratory Distress Syndrome, run by Marya Strand, MD at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Mar 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 26 Dec 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Participants With Extubation Failure (time frame: Within 72 hours of extubation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Mar 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in