Cigarette AddictionVAPECIG 2NCT02398487
Personal Vaporizer vs Cigalike
A study testing cigalike with nicotine and Personal Vaporizer with nicotine in people with Cigarette Addiction, run by University of Catania at 1 site in Italy.
Trial summary
This is a pilot study to compare efficiency and tolerability of a personal vaporizers (PV) new generation electronic cigarette loaded with nicotine e-liquid with cigalike new generation electronic cigarette loaded with nicotine and usual smoking habits, in a group of well characterized regular smokers unwilling to… Read more about this study
- Who is it for?
- Ages 18 to 70 yearsHealthy volunteers can take part
- Conditions the study is for
- Cigarette Addiction
- What is being tested?
- cigalike with nicotine and Personal Vaporizer with nicotine
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 200 participants
- Where
- 1 siteItaly
- Study dates
- Oct 2014to Dec 2015
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- in good general health
- committed to follow the trial procedures
Who cannot join
- recent vaping history (stopped vaping less than 3 months ago)
- use of any other form of non combustible nicotine containing products (chewable tobacco or nicotine replacement therapy) symptomatic cardiovascular disease
- clinical history of asthma and chronic obstructive pulmonary disease (COPD)
- regular psychotropic medication use
- current or past history of alcohol abuse
- use of smokeless tobacco or nicotine replacement therapy, and pregnancy or breastfeeding.
Trial locations and contacts
1 site in 1 country.
Italy1 site
Centro per la Prevenzione e Cura del Tabagismo University of Catania
Catania, Catania, 95100
About this study
Official title: Head-To-Head Comparision of Personal Vaporizers Versus Cigalike: Prospective 6-Month Randomized Control Design Study
This is a pilot study to compare efficiency and tolerability of a personal vaporizers (PV) new generation electronic cigarette loaded with nicotine e-liquid with cigalike new generation electronic cigarette loaded with nicotine and usual smoking habits, in a group of well characterized regular smokers unwilling to quit.
Read the detailed description
RATIONALE
The results of ECLAT - the first randomized controlled trial addressing the impact of electronic cigarette use in relation to smoking reduction, smoking abstinence and safety long-term - have revealed important and persistent modifications in the smoking habits of 300 smokers (not intending to quit) with significant reduction in tobacco cigarettes' consumption (1).
Surprisingly, the reduction in cig/day use in ECLAT was not much different among study groups, with the non-nicotine study group performing much like both high and low nicotine study groups. This was because, with the products used in ECLAT, saliva cotinine levels were well below the concentration threshold considered to be representative for regular smokers (2) or experienced electronic cigarette users (3) in both high and low nicotine study groups. Specifically, the model under investigation in ECLAT is not very efficient at delivering nicotine (4).
With this in mind, we have designed a pilot study to compare efficiency and tolerability of a personal vaporizers (PV) new generation electronic cigarette loaded with nicotine e-liquid with cigalike new generation electronic cigarette loaded with nicotine and usual smoking habits, in a group of well characterized regular smokers unwilling to quit.
STUDY OBJECTIVES
Aims of this pilot study are:
- to assess if a Personal Vaporizers (PV) can effectively reduce tobacco smoking
- to compare if efficacy data with PV E-cigs are better than "cigalike" efficacy
- to evaluate if PV E-cigs are safe to use
METHODS
Study Population 200 regular smokers (smoking ≥ 10 cigarettes per day for at least the past 5 years; eCO ≥ 10 ppm), with an age of 18-70 years, in good general health; and committed to follow the trial procedures will be recruited following placement of advertisements in local newspapers and radio/TV network. Exclusion criteria will include: recent vaping history (stopped vaping less than 3 months ago); use of any other form of non combustible nicotine containing products (chewable tobacco or nicotine replacement therapy) symptomatic cardiovascular disease; clinical history of asthma and chronic obstructive pulmonary disease (COPD); regular psychotropic medication use; current or past history of alcohol abuse; use of smokeless tobacco or nicotine replacement therapy, and pregnancy or breastfeeding.
Study Products
Personal Vaporizer electronic cigarette This new generation device consist of a large lithium battery part (capacity of 2600 mAh) with an internal electronic circuit which includes a current stabilizer and allows the user to manually adjust the energy applied to the atomizer. A new-generation atomizer will be used and will be filled with approximately 2 ml of liquid. The Energy delivery to the atomizer will be set to 9 watts.
These electronic cigarettes will be provided free of charge by the manufacturer.
The liquid will be provided free of charge by the manufacturer Alterna Farmaceutici, Francia Farmaceutici group.
"Cigarette-like Electronic Cigarette" The Cigalike e-Cigarette is a disposable battery-powered electronic nicotine delivery device (ENDD) - that closely resembles the shape of a tobacco cigarette - designed for the purpose of nicotine (and/or aroma) delivery, where no tobacco or combustion is necessary for its operation. This e-Cigarette contains a propylene glycol-free liquid consisting of distilled water, FCC grade vegetable glycerin, natural flavors, artificial flavors, citric acid and may also contain pharmaceutical grade nicotine. The lithium battery has a capacity of 250 mAh and will be fully charged before use. Cartomizers will be filled with approximately 1 ml of a nicotine containing liquid.These electronic cigarettes will be provided free of charge by the manufacturer.
Study Design and Procedures Two hundred regular smokers, (not willing to quit) will be recruited in our center following placement of advertisements in local newspapers and radio/TV network. At baseline, participants will be randomized into three separate study groups. Fifty participants randomized in study group A will receive a "Personal Vaporizer electronic cigarette" and 24-weeks supply of e-liquid (active group); fifty subjects in study group B, 24-week supply of "Cigarette-like Electronic Cigarette" (active group); one hundred participants in study group C will continue usual smoking (control group).
Study Schedule Participants will attend their study visits at the smoking cessation clinic at approximately the same time of day. With the exception of the baseline study day, most visits will take approximately 10-15 minutes.
At baseline (study visit 1), socio-demographic factors, a detailed smoking history and craving will be annotated and individual pack-years (pack/yrs) calculated. Eligible participants will be invited to sign an informed consent form. Cigarette dependence will be measured by Fagerstrom Test for Cigarette Dependence (FTCD). Additionally, levels of carbon monoxide in exhaled breath (eCO) will be measured using a portable device (Micro CO, Micro Medical Ltd, UK). Vital signs (HR and BP), body weight, and adverse events will be also recorded at baseline.
Participants in group A and B will be given a free supply of electronic smoking (on average 2-week supply of ecigs) and instructed on how to correctly use them. Key troubleshooting support will be provided and phone numbers will be supplied for medical assistance. They will also be requested to fill a 2-weeks' study diary recording adverse events. No emphasis on encouragement, motivation and reward for the smoking cessation effort will be provided since this study was intended to monitor smokers (unwilling to quit) using in three different situations.
Baseline visit (Visit 1) in brief
- Informed consent
- Inclusion/exclusion criteria
- CRF (smoking Hx, FTND, eCO, HR, BP, weight, AEs)
- Craving/VAS
- Randomization into either study group A (with Nic) or B (no Nic)
- Provide PV Ecig or Cigalike and dispense 2-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense 2-weeks' study diary for AEs
By and large, at week-2 (study visit 2), week-4 (study visit 3), week-8, week-12, and week-24, participants will a) receive further study diaries for the residual study periods, b) have their eCO levels and vital signs recorded, c) return their completed study diaries and used study products. Additionally, saliva samples will be collected at week-12 and at week-24 for cotinine measurement in those who stated they had not smoked (not even a puff) and with an eCO ≤ 7ppm. Cotton rolls will be placed into polypropylene tubes and stored at -20°C until use. Saliva samples will be analysed in duplicate for cotinine analysis by gas chromatography. At the end of week-24 study visit, no more products will be provided by the investigators.
Week-2 visit (Visit 2) in brief
- Collect 2-weeks' study diary for AEs
- CRF (no. cig/day, eCO, HR, BP)
- Craving/VAS
- Smokers' product preference survey
- Dispense next 2-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 2-weeks' study diary for AEs
Week-4/8 visit (Visits 3 and 4) in brief
- Collect study diary for AEs
- CRF (no. cig/day, eCO, HR, BP)
- Craving/VAS
- Dispense next 4-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 4-weeks' study diary for AEs
Week-12 visit (Visit 5) in brief
- Collect study diary for AEs
- CRF (no. cig/day, eCO, HR, BP and weight)
- Craving/VAS
- Collect saliva sample* (only in those with zero cig/day and eCO ≤ 7ppm, * Times of saliva sampling requires standardization, e.g. same time of the day, within 2 hrs from last vape)
- Dispense next 12-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 12-weeks' study diary for AEs
Week-24 visit (Visit 6)
- Collect study diary for AEs
- CRF (physical examination, no. cig/day, eCO, HR, BP and weight)
- Craving/VAS
- Collect saliva sample* (only in those with zero cig/day and eCO ≤ 7ppm, * Times of saliva sampling requires standardization, e.g. same time of the day, within 2 hrs from last vape)
- Smokers' product preference survey
Study Outcome Measures A ≥50% reduction in the number of cig/day from baseline, defined as self-reported reduction in the number of cig/day (≥50%) compared to baseline (together with an eCO levels reduction, to objectively document a reduction from baseline), will be calculated at each study visit ("reducers").
Abstinence from smoking, defined as complete self-reported abstinence from tobacco smoking - not even a puff (together with an eCO concentration of ≤7 ppm), will be calculated at each study visit ("quitters"). Failing to meet the above criteria defines smoking reduction/cessation failure.
Adverse events, symptoms thought to be related to tobacco smoking and e-Cigarette use and to withdrawal from nicotine will be annotated at baseline and at each subsequent study visit on the adverse event page of the study diary. Vital signs will be also recorded. Participants' perception and liking of the product will be assessed by asking to rate their level of satisfaction with the products compared to their own cigarettes using a visual analogue scale (VAS) from 0 to 10 points (0 = being 'completely unsatisfied', 10 being = 'fully satisfied'); using the same scale, they will also rate how much they miss their own brand (0 = being 'did not miss it at all', 10 being = 'missed too much') and whether they would recommend it to a friend/relative (0 = being 'not recommended at all', 10 being = 'absolutely recommended').
- Conditions
- Cigarette Addiction
- Being tested
- cigalike with nicotine, Personal Vaporizer with nicotine
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
cigalike with nicotineDevice
cigalike 24 mg nicotine or 16 mg nicotine
Personal Vaporizer with nicotineDevice
Personal Vaporizer 16 mg nicotine or 9 mg nicotine
| Study group | Role | What they receive |
|---|---|---|
| Personal Vaporizer | Active comparator | Personal Vaporizer loaded with nicotine Receives: Device: Personal Vaporizer with nicotine |
| Cigalike | Active comparator | Cigalike loaded with nicotine Receives: Device: cigalike with nicotine |
| Usual smoking | No intervention | Not described |
What is being measured
The primary outcome is the main question the study is designed to answer.
Smoking Reduction
50% reduction of cigarette smoked compared to baseline
Measured: 24 week
Secondary outcomes (1)
Smoking Cessation
complete abstinence
Measured: 24 week
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted25 Mar 2015 (estimated)
- Study startOct 2014
- Primary completionDec 2015
- Study completionDec 2015
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Cigarette AddictionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 200 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Catania
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Riccardo Polosa, University of Catania
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02398487
- Sponsor's protocol ID
- VAPECIG 2
- Acronym
- VAPECIG 2
- Status last verified
- Dec 2015
- First submitted
- 9 Jun 2014
- Last updated
- 2 Dec 2015
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 2 Dec 2015. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Head-To-Head Comparision of Personal Vaporizers Versus Cigalike: Prospective 6-Month Randomized Control Design Study
- ClinicalTrials.gov ID
- NCT02398487
- Acronym / sponsor ID
- VAPECIG 2 / VAPECIG 2
- Conditions
- Cigarette Addiction
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 200 participants (actual)
- Lead sponsor
- University of CataniaUniversity, hospital or other
- Study start
- Oct 2014
- Primary completion
- Dec 2015 (actual)
- Study completion
- Dec 2015 (actual)
- First posted
- 25 Mar 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a pilot study to compare efficiency and tolerability of a personal vaporizers (PV) new generation electronic cigarette loaded with nicotine e-liquid with cigalike new generation electronic cigarette loaded with nicotine and usual smoking habits, in a group of well characterized regular smokers unwilling to quit.
Detailed description
RATIONALE
The results of ECLAT - the first randomized controlled trial addressing the impact of electronic cigarette use in relation to smoking reduction, smoking abstinence and safety long-term - have revealed important and persistent modifications in the smoking habits of 300 smokers (not intending to quit) with significant reduction in tobacco cigarettes' consumption (1).
Surprisingly, the reduction in cig/day use in ECLAT was not much different among study groups, with the non-nicotine study group performing much like both high and low nicotine study groups. This was because, with the products used in ECLAT, saliva cotinine levels were well below the concentration threshold considered to be representative for regular smokers (2) or experienced electronic cigarette users (3) in both high and low nicotine study groups. Specifically, the model under investigation in ECLAT is not very efficient at delivering nicotine (4).
With this in mind, we have designed a pilot study to compare efficiency and tolerability of a personal vaporizers (PV) new generation electronic cigarette loaded with nicotine e-liquid with cigalike new generation electronic cigarette loaded with nicotine and usual smoking habits, in a group of well characterized regular smokers unwilling to quit.
STUDY OBJECTIVES
Aims of this pilot study are:
- to assess if a Personal Vaporizers (PV) can effectively reduce tobacco smoking
- to compare if efficacy data with PV E-cigs are better than "cigalike" efficacy
- to evaluate if PV E-cigs are safe to use
METHODS
Study Population 200 regular smokers (smoking ≥ 10 cigarettes per day for at least the past 5 years; eCO ≥ 10 ppm), with an age of 18-70 years, in good general health; and committed to follow the trial procedures will be recruited following placement of advertisements in local newspapers and radio/TV network. Exclusion criteria will include: recent vaping history (stopped vaping less than 3 months ago); use of any other form of non combustible nicotine containing products (chewable tobacco or nicotine replacement therapy) symptomatic cardiovascular disease; clinical history of asthma and chronic obstructive pulmonary disease (COPD); regular psychotropic medication use; current or past history of alcohol abuse; use of smokeless tobacco or nicotine replacement therapy, and pregnancy or breastfeeding.
Study Products
Personal Vaporizer electronic cigarette This new generation device consist of a large lithium battery part (capacity of 2600 mAh) with an internal electronic circuit which includes a current stabilizer and allows the user to manually adjust the energy applied to the atomizer. A new-generation atomizer will be used and will be filled with approximately 2 ml of liquid. The Energy delivery to the atomizer will be set to 9 watts.
These electronic cigarettes will be provided free of charge by the manufacturer.
The liquid will be provided free of charge by the manufacturer Alterna Farmaceutici, Francia Farmaceutici group.
"Cigarette-like Electronic Cigarette" The Cigalike e-Cigarette is a disposable battery-powered electronic nicotine delivery device (ENDD) - that closely resembles the shape of a tobacco cigarette - designed for the purpose of nicotine (and/or aroma) delivery, where no tobacco or combustion is necessary for its operation. This e-Cigarette contains a propylene glycol-free liquid consisting of distilled water, FCC grade vegetable glycerin, natural flavors, artificial flavors, citric acid and may also contain pharmaceutical grade nicotine. The lithium battery has a capacity of 250 mAh and will be fully charged before use. Cartomizers will be filled with approximately 1 ml of a nicotine containing liquid.These electronic cigarettes will be provided free of charge by the manufacturer.
Study Design and Procedures Two hundred regular smokers, (not willing to quit) will be recruited in our center following placement of advertisements in local newspapers and radio/TV network. At baseline, participants will be randomized into three separate study groups. Fifty participants randomized in study group A will receive a "Personal Vaporizer electronic cigarette" and 24-weeks supply of e-liquid (active group); fifty subjects in study group B, 24-week supply of "Cigarette-like Electronic Cigarette" (active group); one hundred participants in study group C will continue usual smoking (control group).
Study Schedule Participants will attend their study visits at the smoking cessation clinic at approximately the same time of day. With the exception of the baseline study day, most visits will take approximately 10-15 minutes.
At baseline (study visit 1), socio-demographic factors, a detailed smoking history and craving will be annotated and individual pack-years (pack/yrs) calculated. Eligible participants will be invited to sign an informed consent form. Cigarette dependence will be measured by Fagerstrom Test for Cigarette Dependence (FTCD). Additionally, levels of carbon monoxide in exhaled breath (eCO) will be measured using a portable device (Micro CO, Micro Medical Ltd, UK). Vital signs (HR and BP), body weight, and adverse events will be also recorded at baseline.
Participants in group A and B will be given a free supply of electronic smoking (on average 2-week supply of ecigs) and instructed on how to correctly use them. Key troubleshooting support will be provided and phone numbers will be supplied for medical assistance. They will also be requested to fill a 2-weeks' study diary recording adverse events. No emphasis on encouragement, motivation and reward for the smoking cessation effort will be provided since this study was intended to monitor smokers (unwilling to quit) using in three different situations.
Baseline visit (Visit 1) in brief
- Informed consent
- Inclusion/exclusion criteria
- CRF (smoking Hx, FTND, eCO, HR, BP, weight, AEs)
- Craving/VAS
- Randomization into either study group A (with Nic) or B (no Nic)
- Provide PV Ecig or Cigalike and dispense 2-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense 2-weeks' study diary for AEs
By and large, at week-2 (study visit 2), week-4 (study visit 3), week-8, week-12, and week-24, participants will a) receive further study diaries for the residual study periods, b) have their eCO levels and vital signs recorded, c) return their completed study diaries and used study products. Additionally, saliva samples will be collected at week-12 and at week-24 for cotinine measurement in those who stated they had not smoked (not even a puff) and with an eCO ≤ 7ppm. Cotton rolls will be placed into polypropylene tubes and stored at -20°C until use. Saliva samples will be analysed in duplicate for cotinine analysis by gas chromatography. At the end of week-24 study visit, no more products will be provided by the investigators.
Week-2 visit (Visit 2) in brief
- Collect 2-weeks' study diary for AEs
- CRF (no. cig/day, eCO, HR, BP)
- Craving/VAS
- Smokers' product preference survey
- Dispense next 2-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 2-weeks' study diary for AEs
Week-4/8 visit (Visits 3 and 4) in brief
- Collect study diary for AEs
- CRF (no. cig/day, eCO, HR, BP)
- Craving/VAS
- Dispense next 4-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 4-weeks' study diary for AEs
Week-12 visit (Visit 5) in brief
- Collect study diary for AEs
- CRF (no. cig/day, eCO, HR, BP and weight)
- Craving/VAS
- Collect saliva sample* (only in those with zero cig/day and eCO ≤ 7ppm, * Times of saliva sampling requires standardization, e.g. same time of the day, within 2 hrs from last vape)
- Dispense next 12-weeks supply of electronic smoking (depending on the study arm allocation)
- Dispense next 12-weeks' study diary for AEs
Week-24 visit (Visit 6)
- Collect study diary for AEs
- CRF (physical examination, no. cig/day, eCO, HR, BP and weight)
- Craving/VAS
- Collect saliva sample* (only in those with zero cig/day and eCO ≤ 7ppm, * Times of saliva sampling requires standardization, e.g. same time of the day, within 2 hrs from last vape)
- Smokers' product preference survey
Study Outcome Measures A ≥50% reduction in the number of cig/day from baseline, defined as self-reported reduction in the number of cig/day (≥50%) compared to baseline (together with an eCO levels reduction, to objectively document a reduction from baseline), will be calculated at each study visit ("reducers").
Abstinence from smoking, defined as complete self-reported abstinence from tobacco smoking - not even a puff (together with an eCO concentration of ≤7 ppm), will be calculated at each study visit ("quitters"). Failing to meet the above criteria defines smoking reduction/cessation failure.
Adverse events, symptoms thought to be related to tobacco smoking and e-Cigarette use and to withdrawal from nicotine will be annotated at baseline and at each subsequent study visit on the adverse event page of the study diary. Vital signs will be also recorded. Participants' perception and liking of the product will be assessed by asking to rate their level of satisfaction with the products compared to their own cigarettes using a visual analogue scale (VAS) from 0 to 10 points (0 = being 'completely unsatisfied', 10 being = 'fully satisfied'); using the same scale, they will also rate how much they miss their own brand (0 = being 'did not miss it at all', 10 being = 'missed too much') and whether they would recommend it to a friend/relative (0 = being 'not recommended at all', 10 being = 'absolutely recommended').
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Personal Vaporizer | Active comparator | Device: Personal Vaporizer with nicotinePersonal Vaporizer loaded with nicotine |
| Cigalike | Active comparator | Device: cigalike with nicotineCigalike loaded with nicotine |
| Usual smoking | No intervention | – |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- in good general health
- committed to follow the trial procedures
Key exclusion criteria (6 listed)
- recent vaping history (stopped vaping less than 3 months ago)
- use of any other form of non combustible nicotine containing products (chewable tobacco or nicotine replacement therapy) symptomatic cardiovascular disease
- clinical history of asthma and chronic obstructive pulmonary disease (COPD)
- regular psychotropic medication use
- current or past history of alcohol abuse
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| cigalike with nicotinecigalike 24 mg nicotine or 16 mg nicotine | Device | Cigalike |
| Personal Vaporizer with nicotinePersonal Vaporizer 16 mg nicotine or 9 mg nicotine | Device | Personal Vaporizer |
Primary outcome
Smoking Reduction
Time frame: 24 week
50% reduction of cigarette smoked compared to baseline
1 secondary outcome
Smoking Cessation
Time frame: 24 week
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Dec 2015.
Related trials for Cigarette Addiction
Active, not recruiting
THE EFFECT OF A TRANSTHEORETICAL MODEL-BASED CHATBOT SUPPORT INTERVENTION ON SMOKING BEHAVIOR IN UNIVERSITY STUDENTS
Smoking ( Cigarette), Smoking (Tobacco) Addiction
Recruiting
Impact of Novel vs. Usual Brand Menthol Cigarettes on Abuse Liability
Cigarette Addiction, Tobacco Use Disorder
Recruiting
A Study Evaluating the Use of an Indoor Air Quality Monitor to Promote a Smoke-free Home
Smoking, Smoking Cessation
Recruiting
Implementation of Tobacco Cessation Programming at Community Behavioral Health Sites
Nicotine Use Disorder, Smoking Cessation
Recruiting
PASCAL Feasibility Study
Smoking Cessation, Smoking (Tobacco) Addiction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing cigalike with nicotine and Personal Vaporizer with nicotine in people with Cigarette Addiction, run by University of Catania at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Dec 2015. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Smoking Reduction (time frame: 24 week). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Dec 2015.