InfertilityNCT02399501
Sonohysterography , 3D Ultrasonography and Hysteroscopy in Assessment of Uterine Factor in Cases of Female Infertility
A study testing hysteroscopy, two dimensional ultrasound and saline sonohysterography in people with Infertility, run by Cairo University at 1 site in Egypt.
Trial summary
Prospective comparative study including 100 infertile patients with suspected uterine lesion. 2D ultrasound, sonohysterography , 3D ultrasound and hysteroscopy will be done to evaluate uterine cavity. Read more about this study
- Who is it for?
- Ages 20 to 40 years, women only
- Conditions the study is for
- Infertility
- What is being tested?
- hysteroscopy, two dimensional ultrasound and saline sonohysterography
- Type of treatment
- Injection or infusion, Medical device, Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- 1 siteEgypt
- Study dates
- Mar 2015to Jan 2016
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 40 years
- Women only
- No healthy volunteers
- Adult
Who may be able to join
- Suspected uterine factor of infertility
Who cannot join
- tubal, ovarian or male factor of infertility
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Sonohysterography and 3D Ultrasonography Versus Diagnostic Hysteroscopy in Assessment of Uterine Factor in Cases of Female Infertility
Prospective comparative study including 100 infertile patients with suspected uterine lesion. 2D ultrasound, sonohysterography , 3D ultrasound and hysteroscopy will be done to evaluate uterine cavity.
Read the detailed description
All patients will be examined by 2D transvaginal ultrasound using a 6.5 MHz probe (Sonoace 5000, Medison Co. Ltd, korea). Examination is performed after emptying of the bladder in dorsal lithotomy position.
Three dimensional ultrasound will be performed using Medison, Voulson 530 D-MT ultrasound machine (Medison Co. Ltd, Korea). The uterus is visualized in the longitudinal plane, the ultrasound probe is kept steady and the patient is asked to lie still on the examination bed.
Sonohysterography will be done after introduction of the catheter into the cervix, a twenty milliliter syringe which is prefilled with the distending media (saline) is then fitted to the catheter. The speculum is removed and endovaginal probe is introduced in the posterior vaginal fornix. The uterus is then visualized in the longitudinal plane to demonstrate the endometrial cavity and the catheter. Once this is possible, sterile saline is slowly injected through the catheter into the uterine cavity; up to ten milliliter of saline is usually enough for the procedure.
Hysteroscopy will be done under general anesthesia. The hysteroscopy is rigid continuous flow diagnostic hysteroscopy . It has a 30º panoramic optic which is 4 mm in diameter and the diagnostic continuous flow outer sheath is 6.5 mm in diameter.
- Conditions
- Infertility
- Being tested
- hysteroscopy, two dimensional ultrasound, saline sonohysterography, three dimensional ultrasound
- Keywords
- 2D ultrasound, 3D ultrasound, sonohysterography, hysteroscopy, Uterine factor of infertility
- Medical subject headings
- Infertility
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
hysteroscopyProcedure or surgery
Hysteroscopy is done under general anesthesia. The hysteroscopy used is rigid continuous flow diagnostic hysteroscopy (Tuttligen, Karl Storz, Germany). It has a 30º panoramic optic which is 4 mm in diameter and the diagnostic continuous flow outer sheath is 6.5 mm in diameter.
two dimensional ultrasoundDevice
Also called (Sonoace 5000)
Examination is performed after emptying of the bladder in dorsal lithotomy position .The probe is introduced into the posterior fornix of the vagina, then the following structures are examined, the uterus for site, size and mobility, the myometrium for fibroids and adenomyosis, the endometrium for uniformity, polyps, submucous fibroids and intrauterine adhesions, the cervix for nabothian follicles and polyps, the adenexa and ovaries for site, size, mobility, follicles, cysts and corpus luteum
saline sonohysterographyDevice
Also called (Sonoace 5000)
sterile speculum is introduced and the vagina and cervix is cleaned with povidone iodine 10%. Cook ET (embryo transfer) catheter is used. . After introduction of the catheter into the cervix, a twenty milliliter syringe which will be prefilled with the distending media (saline) then fitted to the catheter. The speculum is removed and endovaginal probe is introduced in the posterior vaginal fornix
three dimensional ultrasoundDevice
Also called (Medison, Voulson 530 D-MT ultrasound machine)
The uterus is visualized in the longitudinal plane, the ultrasound probe is kept steady and the patient is asked to lie still on the examination bed. The volume mode is switched on. Three D volume is generated by the automatic rotation of the mechanical transducer through 360º. The acquired volume is in the shape of a transacted cone with a depth of 4.3 - 8.6 cm and a vertical angle α = 90º. Using the medium line density, the typical acquisition time is a round 10 seconds
| Study group | Role | What they receive |
|---|---|---|
| uterine lesion ultrasound, hysteroscopy | Experimental | evaluation of female with proved uterine lesion by two dimensional ultrasound, three dimensional ultrasound, saline sonohysterography and hysteroscopy Receives: Procedure: hysteroscopy; Device: two dimensional ultrasound; Device: saline sonohysterography; Device: three dimensional ultrasound |
What is being measured
The primary outcome is the main question the study is designed to answer.
detection of uterine lesion
Measured: at time of hystroscopy
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Mar 2015 (estimated)
- Study startMar 2015
- Primary completionJan 2016
- Study completionJan 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for InfertilityStudies of the same condition, open and under way.
- More trials run by Cairo UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 100 participants (actual)
Sponsor and investigators
- Lead sponsor
- Cairo University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Ahmed Maged, Cairo University
- Investigators
- Ahmed Maged, MD, Principal investigator, Kasr Alainy medical school
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02399501
- Sponsor's protocol ID
- 132
- Status last verified
- Mar 2017
- First submitted
- 5 Mar 2015
- Last updated
- 21 Mar 2017
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 21 Mar 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Sonohysterography and 3D Ultrasonography Versus Diagnostic Hysteroscopy in Assessment of Uterine Factor in Cases of Female Infertility
- ClinicalTrials.gov ID
- NCT02399501
- Acronym / sponsor ID
- 132
- Conditions
- Infertility
- Keywords
- 2D ultrasound, 3D ultrasound, sonohysterography, hysteroscopy, Uterine factor of infertility
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 100 participants (actual)
- Lead sponsor
- Cairo UniversityUniversity, hospital or other
- Study start
- Mar 2015 (actual)
- Primary completion
- Jan 2016 (actual)
- Study completion
- Jan 2016 (actual)
- First posted
- 26 Mar 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Prospective comparative study including 100 infertile patients with suspected uterine lesion. 2D ultrasound, sonohysterography , 3D ultrasound and hysteroscopy will be done to evaluate uterine cavity.
Detailed description
All patients will be examined by 2D transvaginal ultrasound using a 6.5 MHz probe (Sonoace 5000, Medison Co. Ltd, korea). Examination is performed after emptying of the bladder in dorsal lithotomy position.
Three dimensional ultrasound will be performed using Medison, Voulson 530 D-MT ultrasound machine (Medison Co. Ltd, Korea). The uterus is visualized in the longitudinal plane, the ultrasound probe is kept steady and the patient is asked to lie still on the examination bed.
Sonohysterography will be done after introduction of the catheter into the cervix, a twenty milliliter syringe which is prefilled with the distending media (saline) is then fitted to the catheter. The speculum is removed and endovaginal probe is introduced in the posterior vaginal fornix. The uterus is then visualized in the longitudinal plane to demonstrate the endometrial cavity and the catheter. Once this is possible, sterile saline is slowly injected through the catheter into the uterine cavity; up to ten milliliter of saline is usually enough for the procedure.
Hysteroscopy will be done under general anesthesia. The hysteroscopy is rigid continuous flow diagnostic hysteroscopy . It has a 30º panoramic optic which is 4 mm in diameter and the diagnostic continuous flow outer sheath is 6.5 mm in diameter.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| uterine lesion ultrasound, hysteroscopy | Experimental | Procedure: hysteroscopy, Device: two dimensional ultrasound, Device: saline sonohysterography, Device: three dimensional ultrasoundevaluation of female with proved uterine lesion by two dimensional ultrasound, three dimensional ultrasound, saline sonohysterography and hysteroscopy |
Who may qualify
- Ages
- 20 to 40 years
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (1 listed)
- Suspected uterine factor of infertility
Key exclusion criteria (1 listed)
- tubal, ovarian or male factor of infertility
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| hysteroscopyHysteroscopy is done under general anesthesia. The hysteroscopy used is rigid continuous flow diagnostic hysteroscopy (Tuttligen, Karl Storz, Germany). It has a 30º panoramic optic which is 4 mm in diameter and the diagnostic continuous flow outer sheath is 6.5 mm in diameter. | Procedure or surgery | uterine lesion ultrasound, hysteroscopy |
| two dimensional ultrasoundAlso: (Sonoace 5000)Examination is performed after emptying of the bladder in dorsal lithotomy position .The probe is introduced into the posterior fornix of the vagina, then the following structures are examined, the uterus for site, size and mobility, the myometrium for fibroids and adenomyosis, the endometrium for uniformity, polyps, submucous fibroids and intrauterine adhesions, the cervix for nabothian follicles and polyps, the adenexa and ovaries for site, size, mobility, follicles, cysts and corpus luteum | Device | uterine lesion ultrasound, hysteroscopy |
| saline sonohysterographyAlso: (Sonoace 5000)sterile speculum is introduced and the vagina and cervix is cleaned with povidone iodine 10%. Cook ET (embryo transfer) catheter is used. . After introduction of the catheter into the cervix, a twenty milliliter syringe which will be prefilled with the distending media (saline) then fitted to the catheter. The speculum is removed and endovaginal probe is introduced in the posterior vaginal fornix | Device | uterine lesion ultrasound, hysteroscopy |
| three dimensional ultrasoundAlso: (Medison, Voulson 530 D-MT ultrasound machine)The uterus is visualized in the longitudinal plane, the ultrasound probe is kept steady and the patient is asked to lie still on the examination bed. The volume mode is switched on. Three D volume is generated by the automatic rotation of the mechanical transducer through 360º. The acquired volume is in the shape of a transacted cone with a depth of 4.3 - 8.6 cm and a vertical angle α = 90º. Using the medium line density, the typical acquisition time is a round 10 seconds | Device | uterine lesion ultrasound, hysteroscopy |
Primary outcome
detection of uterine lesion
Time frame: at time of hystroscopy
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Mar 2017.
Related trials for Infertility
RecruitingObservational study
International Pilot Study for Dual Non-invasive Assesment of Embryo Development
Infertility
Active, not recruitingObservational study
Retrieval of Sperm From Men With Azoospermia Using Ultrasound-guided Rete Testis Aspiration
Azoospermia, Nonobstructive, Infertility, Male
Not yet recruiting
Spinery Basivertebral Nerve Ablation for Vertebrogenic Chronic Low Back Pain
Low Back Pain, Chronic Low Back Pain (CLBP)
RecruitingObservational study
Impact of Infertility on the Sexual Sphere in Couples Undergoing Assisted Reproduction
Sexual Health Quality of Life, Infertile Patients
RecruitingObservational study
Pilot Study of Discarded Blastocysts
Infertility (IVF Patients)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Ahmed Maged, MD principal investigator
Kasr Alainy medical school
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing hysteroscopy, two dimensional ultrasound and saline sonohysterography in people with Infertility, run by Cairo University at 1 site in Egypt.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 21 Mar 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
detection of uterine lesion (time frame: at time of hystroscopy). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Mar 2017.