Diabetes Mellitus, Type 1NCT02463682
Early Feasibility Study of Zone-MPC and HMS With DiAs in the Outpatient Setting
A study testing CGM and Insulin Pump in people with Diabetes Mellitus, Type 1, run by Sansum Diabetes Research Institute at 3 sites in United States.
Trial summary
This is a feasibility study of an artificial pancreas (AP) system with our previously validated Zone-MPC and Health Monitoring System (HMS) algorithms (ClinicalTraisl.gov: NCT01929798) integrated into the Diabetes Assistant (DiAs) system. Read more about this study
- Who is it for?
- Ages 21 to 65 years
- Conditions the study is for
- Diabetes Mellitus, Type 1
- What is being tested?
- CGM and Insulin Pump
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 9 participants
- Where
- 3 sitesUnited States
- Study dates
- May 2015to Oct 2015
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 21 to 65 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Clinical diagnosis, based on investigator assessment, of type 1 diabetes for at least one year and using insulin for at least 1 year and an insulin pump for at least 6 months
- Willing to wear the study CGM device for the duration of the study
- Age ≥21 to <65 years
- HbA1c <10.0%; if HbA1c <6.0% then total daily insulin must be ≥0.5 U/kg
- For females, not currently known to be pregnant If female and sexually active, must agree to use a form of contraception to prevent pregnancy while a participant in the study. A negative urine pregnancy test will be required for all premenopausal women who are not surgically sterile. Subjects who become pregnant will be discontinued from the study.
- Demonstration of proper mental status and cognition for the study
Show all 12Show fewer
- Currently using insulin-to-carbohydrate ratio to calculate meal bolus sizes
- Hypoglycemia awareness as demonstrated by a Clarke Hypoglycemia Unawareness score of 2 or lower
- Access to internet and cell phone service at home, and a computer for downloading device data
- Availability of care partner committed to participating in training activities, knowledgeable at all times of the participant's location, and being present and available to provide assistance when system is being used at night
- Commitment to maintaining uninterrupted availability via cell phone and avoiding any overnight travel for the duration the period using the closed-loop system
- An understanding of and willingness to follow the protocol and sign the informed consent
Who cannot join
- Admission for diabetic ketoacidosis in the 12 months prior to enrollment
- Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
- History of a seizure disorder (except hypoglycemic seizure), unless written clearance is received from a neurologist
- Coronary artery disease or heart failure, unless written clearance is received from a cardiologist
- History of cardiac arrhythmia (except for benign premature atrial contractions and benign premature ventricular contractions which are permitted)
- Cystic fibrosis
Show all 23Show fewer
- A known medical condition that in the judgment of the investigator might interfere with the completion of the protocol such as the following examples:
- Inpatient psychiatric treatment in the past 6 months for either the subject or the subject's primary care giver (i.e., parent or guardian)
- Presence of a known adrenal disorder
- Abnormal liver function test results (Transaminase >2 times the upper limit of normal); testing required for subjects taking medications known to affect liver function or with diseases known to affect liver function
- Abnormal renal function test results (calculated GFR <60 mL/min/1.73m2); testing required for subjects with diabetes duration of greater than 5 years post onset of puberty
- Active gastroparesis
- If on antihypertensive, thyroid, anti-depressant or lipid lowering medication, lack of stability on the medication for the past 2 months prior to enrollment in the study
- Uncontrolled thyroid disease (TSH undetectable or >10 mlU/L); testing required within three months prior to admission for subjects with a goiter or who are on thyroid hormone replacement, and within one year otherwise
- Abuse of alcohol or recreational drugs
- Infectious process not anticipated to resolve prior to study procedures (e.g. meningitis, pneumonia, osteomyelitis)
- A recent injury to body or limb, muscular disorder, use of any medication, any carcinogenic disease, or other significant medical disorder if that injury, medication or disease in the judgment of the investigator will affect the completion of the protocol
- Current use of the following drugs and supplements:
- Acetaminophen
- Any medication being taken to lower blood glucose, such as Pramlintide, Metformin,GLP-1 Analogs such as Liraglutide, and nutraceuticals intended to lower blood glucose
- Beta blockers
- Oral or injectable glucocorticoids
- Any other medication that the investigator believes is a contraindication to the subject's participation
Trial locations and contacts
3 sites in 1 country.
United States3 sites
University of Virginia
Charlottesville, Virginia, 22903
Mayo Clinic
Rochester, Minnesota, 55905
William Sansum Diabetes Center
Santa Barbara, California, 93111
About this study
Official title: Early Feasibility Study of a Zone-Model Predictive Control (MPC) Controller and a Health Monitoring System (HMS) With the Diabetes Assistant (DiAS) in the Outpatient Setting
This is a feasibility study of an artificial pancreas (AP) system with our previously validated Zone-MPC and Health Monitoring System (HMS) algorithms (ClinicalTraisl.gov: NCT01929798) integrated into the Diabetes Assistant (DiAs) system.
Read the detailed description
This is a feasibility study of an artificial pancreas (AP) system with our previously validated Zone-MPC and Health Monitoring System (HMS) algorithms (ClinicalTraisl.gov: NCT01929798) integrated into the Diabetes Assistant (DiAs) system. The system will be evaluated on 2-3 subjects per site (n=6-9 subjects) for 2 weeks at 3 different sites (William Sansum Diabetes Center, University of Virginia, and Mayo Clinic, Rochester, MN). Basal rates will be adjusted in a run-to-run manner by study physicians prior to the closed-loop phase for a maximum of 3 weeks. Subjects will then complete 2 weeks at home use of the Zone-MPC/HMS system using the DIAs platform for a closed-loop feasibility trial. The purpose of this pilot study is to establish that safe day-and-night use of the Zone-MPC/HMS system integrated into the DiAs is achievable in the home environment, to analyze and learn to improve upon the run-to- run optimization process, and to collect efficacy data to inform a future larger study.
- Conditions
- Diabetes Mellitus, Type 1
- Being tested
- CGM and Insulin Pump, Closed-Loop Control System
- Keywords
- Artificial Pancreas, Diabetes Mellitus, Type 1, Autoimmune Diseases, Diabetes Mellitus, Endocrine System Diseases, Glucose Metabolism Disorders, Immune System Diseases, Metabolic Diseases
- Medical subject headings
- Diabetes Mellitus, Type 1, Autoimmune Diseases, Diabetes Mellitus, Endocrine System Diseases, Glucose Metabolism Disorders, Immune System Diseases, Metabolic Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CGM and Insulin PumpDevice
Dexcom G4 Platinum CGM with Share AP Receiver Roche Accu-Chek insulin pump
Closed-Loop Control SystemDevice
The devices that will be used in the Closed-Loop Control System include the following components:
DiAs - a smart-phone medical platform; Dexcom Dexcom G4 Platinum connected to DiAs via Bluetooth CGM receiver; Roche Accu-Chek insulin pump connected to DiAs via wireless Bluetooth; Remote Monitoring Server connected to DiAs via 3G or local Wi-Fi network, and Zone-MPC and HMS algorithms running on DiAs (MPC and HMS)
| Study group | Role | What they receive |
|---|---|---|
| Sensor-Augmented Pump Open-Loop Care (Week 1) | Active comparator | The subjects Sensor-Augmented Pump Open-Loop Care for the first week of the study before any adjustments to pump settings. Receives: Device: CGM and Insulin Pump |
| Closed-Loop Control System with Zone MPC and HMS | Experimental | The artificial pancreas system will be allowed to employ its Model Predictive Control algorithm to make decisions about insulin delivery based on measured glucose levels. The Health Monitoring System algorithm uses the same CGM data as the MPC control algorithm but utilizes a separate algorithm for trending and predictions of future glucose values. Using a redundant and independent algorithm is an important safety feature of the overall AP device. Receives: Device: Closed-Loop Control System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Safety and efficacy of the system, as assessed by the composite outcome of time in range for glucose levels of 70-180 mg/dL and time < 70 mg/dL.
The primary endpoint for this pilot study will be to determine the safety and efficacy of the system, as assessed by the composite outcome of time in range for glucose levels of 70-180 mg/dL and time < 70 mg/dL, comparing between sensor-augmented pump use (open loop care) (week 1) to closed-loop care (final week), so as to determine the feasibility of eventual long-term use of the system.
Measured: 1 Week
Secondary outcomes (9)
Time in range for glucose 80-140 mg/dL
Time in range for glucose 80-140 mg/dL at all times unless described otherwise.
Measured: 1 Week
Time in range for glucose during the nocturnal period
Time in range for glucose 70-180 mg/dL during the nocturnal period.
Measured: 1 week
Time in Range Postprandial
Time in range for glucose 70-180 mg/dL postprandial, for 5 hours following all meals
Measured: 1 Week
Markers of hypo- and hyperglycemia
Markers of hypo- and hyperglycemia.
Measured: 1 Week
Insulin Doses Given
Change in insulin doses given between the open and closed-loop phases of the study.
Measured: 1 Week
Treatments for hypoglycemia
Treatments for hypoglycemia between the open and closed-loop phases of the study.
Measured: 1 week
Number of alerts given by the HMS to prevent hypoglycemia
Number of alerts given by the HMS to prevent hypoglycemia during closed-Loop control.
Measured: 2 Weeks
Outside interventions needed
Outside interventions needed to aid with treatment during closed-Loop control.
Measured: 2 Weeks
Failure analysis of the devices/connectivity issues that may occur.
Failure analysis of the devices/connectivity issues that may occur during closed-Loop control.
Measured: 2 Weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Jun 2015 (estimated)
- Study startMay 2015
- Primary completionOct 2015
- Study completionOct 2015
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Diabetes Mellitus, Type 1Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Enrolment
- 9 participants (actual)
Sponsor and investigators
- Lead sponsor
- Sansum Diabetes Research Institute
- Sponsor type
- University, hospital or other
- Collaborators
- University of California, Santa Barbara, Mayo Clinic, University of Virginia, University of Padova
- Responsible party
- Sponsor
- Investigators
- Francis J Doyle III, PhD, Principal investigator, University of California, Santa Barbara/William Sansum Diabetes CenterEyal Dassau, PhD, Principal investigator, University of California, Santa Barbara/William Sansum Diabetes CenterJordan E Pinsker, MD, Principal investigator, Sansum Diabetes Research InstituteAnanda Basu, MD, Principal investigator, Mayo Clinic, Rochester, MNYogish Kudva, MD, Principal investigator, Mayo Clinic, Rochester, MNBoris Kovatchev, PhD, Principal investigator, University of VirginiaSue Brown, MD, Principal investigator, University of VirginiaStephen Patek, PhD, Principal investigator, University of Virginia
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02463682
- Sponsor's protocol ID
- 99796-JPIN
- Status last verified
- Apr 2016
- First submitted
- 28 May 2015
- Last updated
- 11 Apr 2016
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 11 Apr 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Early Feasibility Study of a Zone-Model Predictive Control (MPC) Controller and a Health Monitoring System (HMS) With the Diabetes Assistant (DiAS) in the Outpatient Setting
- ClinicalTrials.gov ID
- NCT02463682
- Acronym / sponsor ID
- 99796-JPIN
- Conditions
- Diabetes Mellitus, Type 1
- Keywords
- Artificial Pancreas, Diabetes Mellitus, Type 1, Autoimmune Diseases, Diabetes Mellitus, Endocrine System Diseases, Glucose Metabolism Disorders, Immune System Diseases, Metabolic Diseases
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 9 participants (actual)
- Lead sponsor
- Sansum Diabetes Research InstituteUniversity, hospital or other
- Collaborators
- University of California, Santa Barbara, Mayo Clinic, University of Virginia, University of Padova
- Study start
- May 2015
- Primary completion
- Oct 2015 (actual)
- Study completion
- Oct 2015 (actual)
- First posted
- 4 Jun 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a feasibility study of an artificial pancreas (AP) system with our previously validated Zone-MPC and Health Monitoring System (HMS) algorithms (ClinicalTraisl.gov: NCT01929798) integrated into the Diabetes Assistant (DiAs) system.
Detailed description
This is a feasibility study of an artificial pancreas (AP) system with our previously validated Zone-MPC and Health Monitoring System (HMS) algorithms (ClinicalTraisl.gov: NCT01929798) integrated into the Diabetes Assistant (DiAs) system. The system will be evaluated on 2-3 subjects per site (n=6-9 subjects) for 2 weeks at 3 different sites (William Sansum Diabetes Center, University of Virginia, and Mayo Clinic, Rochester, MN). Basal rates will be adjusted in a run-to-run manner by study physicians prior to the closed-loop phase for a maximum of 3 weeks. Subjects will then complete 2 weeks at home use of the Zone-MPC/HMS system using the DIAs platform for a closed-loop feasibility trial. The purpose of this pilot study is to establish that safe day-and-night use of the Zone-MPC/HMS system integrated into the DiAs is achievable in the home environment, to analyze and learn to improve upon the run-to- run optimization process, and to collect efficacy data to inform a future larger study.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Sensor-Augmented Pump Open-Loop Care (Week 1) | Active comparator | Device: CGM and Insulin PumpThe subjects Sensor-Augmented Pump Open-Loop Care for the first week of the study before any adjustments to pump settings. |
| Closed-Loop Control System with Zone MPC and HMS | Experimental | Device: Closed-Loop Control SystemThe artificial pancreas system will be allowed to employ its Model Predictive Control algorithm to make decisions about insulin delivery based on measured glucose levels. The Health Monitoring System algorithm uses the same CGM data as the MPC control algorithm but utilizes a separate algorithm for trending and predictions of future glucose values. Using a redundant and independent algorithm is an important safety feature of the overall AP device. |
Who may qualify
- Ages
- 21 to 65 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (12 listed)
- Clinical diagnosis, based on investigator assessment, of type 1 diabetes for at least one year and using insulin for at least 1 year and an insulin pump for at least 6 months
- Willing to wear the study CGM device for the duration of the study
- Age ≥21 to <65 years
- HbA1c <10.0%; if HbA1c <6.0% then total daily insulin must be ≥0.5 U/kg
- For females, not currently known to be pregnant If female and sexually active, must agree to use a form of contraception to prevent pregnancy while a participant in the study. A negative urine pregnancy test will be required for all premenopausal women who are not surgically sterile. Subjects who become pregnant will be discontinued from the study.
Key exclusion criteria (23 listed)
- Admission for diabetic ketoacidosis in the 12 months prior to enrollment
- Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
- History of a seizure disorder (except hypoglycemic seizure), unless written clearance is received from a neurologist
- Coronary artery disease or heart failure, unless written clearance is received from a cardiologist
- History of cardiac arrhythmia (except for benign premature atrial contractions and benign premature ventricular contractions which are permitted)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CGM and Insulin PumpDexcom G4 Platinum CGM with Share AP Receiver Roche Accu-Chek insulin pump | Device | Sensor-Augmented Pump Open-Loop Care (Week 1) |
| Closed-Loop Control SystemThe devices that will be used in the Closed-Loop Control System include the following components: DiAs - a smart-phone medical platform; Dexcom Dexcom G4 Platinum connected to DiAs via Bluetooth CGM receiver; Roche Accu-Chek insulin pump connected to DiAs via wireless Bluetooth; Remote Monitoring Server connected to DiAs via 3G or local Wi-Fi network, and Zone-MPC and HMS algorithms running on DiAs (MPC and HMS) | Device | Closed-Loop Control System with Zone MPC and HMS |
Primary outcome
Safety and efficacy of the system, as assessed by the composite outcome of time in range for glucose levels of 70-180 mg/dL and time < 70 mg/dL.
Time frame: 1 Week
The primary endpoint for this pilot study will be to determine the safety and efficacy of the system, as assessed by the composite outcome of time in range for glucose levels of 70-180 mg/dL and time < 70 mg/dL, comparing between sensor-augmented pump use (open loop care) (week 1) to closed-loop care (final week), so as to determine the feasibility of eventual long-term use of the system.
9 secondary outcomes
Time in range for glucose 80-140 mg/dL
Time frame: 1 Week
Time in range for glucose during the nocturnal period
Time frame: 1 week
Time in Range Postprandial
Time frame: 1 Week
Markers of hypo- and hyperglycemia
Time frame: 1 Week
Insulin Doses Given
Time frame: 1 Week
Treatments for hypoglycemia
Time frame: 1 week
Number of alerts given by the HMS to prevent hypoglycemia
Time frame: 2 Weeks
Outside interventions needed
Time frame: 2 Weeks
Failure analysis of the devices/connectivity issues that may occur.
Time frame: 2 Weeks
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 11 Apr 2016.
Related trials for Diabetes Mellitus, Type 1
Not yet recruitingPhase 3
A Study to Evaluate the Effectiveness and Safety of the Drug AZD6234 for Managing Weight in Adults Who Are Obese or Overweight. These Participants May or May Not Also Have Type 2 Diabetes
Obesity, Overweight
RecruitingPhase 1
Pharmacokinetics, Safety, and Immunogenicity Comparison of Bmab1700 and Opdivo® as Adjuvant Monotherapy in Participants With Melanoma
Melanoma
Active, not recruitingPhase 2
A Study of Botensilimab and Balstilimab for the Treatment of Colorectal Cancer
Metastatic Colorectal Cancer
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Francis J Doyle III, PhD principal investigator
University of California, Santa Barbara/William Sansum Diabetes Center
Eyal Dassau, PhD principal investigator
University of California, Santa Barbara/William Sansum Diabetes Center
Jordan E Pinsker, MD principal investigator
Sansum Diabetes Research Institute
3 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing CGM and Insulin Pump in people with Diabetes Mellitus, Type 1, run by Sansum Diabetes Research Institute at 3 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 12 inclusion and 23 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 11 Apr 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Safety and efficacy of the system, as assessed by the composite outcome of time in range for glucose levels of 70-180 mg/dL and time < 70 mg/dL. (time frame: 1 Week). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2016.