AzTrials
AzTrials

Atrial FibrillationPhase 1/2NCT02493075

Ablation of Paroxysmal Atrial Fibrillation Using the Appropriate Contact Force in a Chinese Population

A Phase 1/2 study testing The operator blinded to the contact force data or not. in people with Atrial Fibrillation, run by Sir Run Run Shaw Hospital at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The objective of the study is:Phase I: To validate or otherwise determine the Chinese-specific appropriate contact force during PVI in PAF.Phase II: To evaluate the effectiveness and safety of ablation guided by the appropriate contact force. Read more about this study

Who is it for?
Ages 18 to 75 years
Conditions the study is for
Atrial Fibrillation
What is being tested?
The operator blinded to the contact force data or not.
Could I receive a placebo?
No, everyone receives an active treatment
How many people
140 participants
Where
1 siteChina
Study dates
Mar 2015to Jun 2018
Phase
Phase 1/2
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age: 18 - 75 years
  • Symptomatic PAF refractory to at least one antiarrhythmic drug
  • Minimum of two episodes of recurrent self-terminating AF within prior 12 months and with latest documented episode within 6 months prior ablation procedure
  • First catheter ablation
  • Patient is able and willing to provide written informed consent.

Who cannot join

  • Persistent or long-standing persistent AF
  • >4 cardioversions in prior 12 months
  • Myocardial infarction(MI), coronary artery bypass grafting(CABG) or percutaneous coronary intervention (PCI) within preceding 3 months
  • Left atrial diameter >5.0 cm or <3.5 cm
  • Left ventricular ejection fraction by echocardiography <40%
  • New York Heart Association(NYHA)class III or IV
Show all 9Show fewer
  • History of heart surgery or any previous ablation for AF
  • Intracardiac thrombus
  • Females who are pregnant or breast feeding.

Trial locations and contacts

1 site in 1 country.

Chenyang Jiang, MD contact

+86 13857190051

jiangchenyang@gmail.com

China1 site, 1 recruiting
  • Sir Run Run Shaw Hospital

    Hangzhou, Zhejiang, 310016

    Chenyang Jiang, MD, +86 13857190051, jiangchenyang@gmail.com

    Recruiting

Other trials in China

About this study

Official title: Ablation of Paroxysmal Atrial Fibrillation Using the Appropriate Contact Force in a Chinese Population: A Prospective Randomized Single-center Trial

The objective of the study is:Phase I: To validate or otherwise determine the Chinese-specific appropriate contact force during PVI in PAF.Phase II: To evaluate the effectiveness and safety of ablation guided by the appropriate contact force.

Read the detailed description

Background: Atrial fibrillation (AF) is a major cause of substantial mortality and morbidity from thromboembolism, heart failure (HF), and cognitive dysfunction. With the aging of the population and improved survival after myocardial infarction and HF, AF is emerging as a major public health concern.

Recently, significant progress has been made in treatment of AF with catheter ablation, emerging as an increasingly important technique. According to the current guidelines, catheter ablation can be considered as the first-line treatment of choice for patients with drug refractory paroxysmal AF (PAF). Circumferential PV isolation (CPVI) is a widely accepted cornerstone of this procedure, but limited by an unacceptable recurrence rate, mainly due to recovery of pulmonary vein (PV) conduction.

Durable, continuous, transmural isolation of PV is one of the most important goals of radiofrequency catheter ablation (RFCA) for PAF. The contact force (CF) between the ablation catheter and target tissue was considered closely related to the ablation effectiveness. Appropriate CF should be able to generate enough tissue lesions, and avoid the complications, such as cardiac perforation, atrial-esophageal fistula. Nowadays, irrigated ablation catheters are widely used, but the CF is mostly dependent on operators' experience and feeling, unable to be precisely measured. The tissue lesion produced would be variable in different operators, and the learning curve would be time consuming.

The newly approved CF catheter enables measurement of catheter tip contact force and force vector, providing the real-time CF during ablation. It would be helpful, not only for effective lesions formation, but also for the prevention from complications.

Studies from Western-population indicated that higher long-term successful rate could be achieved by using CF catheter, and CF between 10 to 20g was adopted in most centers. It would be important to find the appropriate range of CF for Chinese populations, because of various factors including for instance thinner and smaller atrial chambers among Chinese.

Objectives Phase I: To validate or otherwise determine the Chinese-specific appropriate CF during PVI in PAF.

Phase II: To evaluate the effectiveness and safety of ablation guided by the appropriate CF Trial design and Treatment of Subjects Phase I Instrument: CARTO™, Biosense Webster, Electrophysiology(EP)recording system, Thermocool® SmartTouch™ Catheter,Lasso/Navi-Lasso catheter, etc.

NO. of cases: 20 Study duration: 2 months Strategy:Circumferential pulmonary vein isolation Procedure: Local anaesthesia, Sedation Catheters are advanced through the right/left femoral vein. After double transseptal punctures, 8F or 8.5F SL1 Swartz sheath and Steerable sheath (e.g. Agilis, St Jude) will be placed in left atrium (LA), followed by PVs' venography Establishment of the anatomical model of LA and all PVs: Respiratory gating, Point-by-Point or Fast Anatomical Mapping (FAM). When using Point-by-Point, CF would be controlled between 5 to 10g. When using FAM, the model around PVs would be adjusted by SmartTouch catheter with CF 5-10g.

Parameter setting: Power-anterior wall 35W, posterior wall 30W; Irrigated flow rate = 17-30ml/min;Impendence - up to 170Ω; Operator: Dr. Chenyang Jiang Ablation catheter could be moved if, electrical activity amplitude decrease >80%, impedance decrease >10Ω, or ablation time more than 20s.

Endpoint: Bi-directional block between left atrial and pulmonary vein (LA-PV), and no capture along CPVI line.

The operator will be blinded to CF data, which would be monitored by the assistant. When the CF is higher than 40g, the operator will be warned.

Parameters: total procedure time, model reconstruction time, power, ablation time, impedance, CF, force-time integral (FTI).

Introduction for PV ablation:

Perform circumferential PV ablation in the order.

  1. When PV is isolated after circular linear ablation without touch-up ablation, 30min waiting time + isoproterenol(ISP)/adenosine triphosphate(ATP) induction would be performed to detect the acute reconnection. If there's no reconnection, each segment will be identified as "isolated segment", and the ablation CF, time, FTI, and the power of each segment will be recorded.
  2. When PV isolated initially, but reconnected by 30min+ISP/ATP observation, re-isolation would be performed, and the segment with conduction gaps(GAP) will be identified as "acute reconnected segment(s)".
  3. If PV isolation not achieved by initial circumferential ablation, additional ablation along the circular lesion will be performed until PV isolated, and the segment(s) re-ablated will be identified as "unisolated segment(s)", record the parameters. 30min+ISP/ATP detection will be performed after isolation, "isolated segment(s)" and "acute reconnected segment(s)" will be identified, as described above in a. and b. If the "acute reconnected segment(s)" is the same segment(s) as "unisolated segment(s)", classify to the latter group.

Analysis for appropriate CF For each segment, single variable and multiple regression analysis will be performed between the three groups ("isolated segment"," acute reconnected segment ", and "unisolated segment"), to define an "appropriate CF". The sensitivity and specificity of the "appropriate CF" will be analyzed.

Phase II:

Instrument: CARTO™, Biosense Webster, EP recording system, Thermocool® SmartTouch™ Catheter,Lasso/Navi-Lasso catheter, etc.

NO. of cases: 120 Study duration: enrollment - 12 months, follow-up - 12 months, Data analysis and papers preparation - 3 months.

Strategy:Circumferential pulmonary vein isolation Patients will be randomized with 1:1 ratio into one of the two following groups: "CF guided group" and "usual ablation group".

Procedure: The preparation, including anaesthesia, sedation, vascular access, transseptal puncture, is the same as described in phase I.

CF guided group:

After the establishment of the anatomical model of LA and all PVs (the same as phase I), ablation will be performed with the guidance of real-time CF, ablation time, FTI, etc. CF will be controlled in the range of "appropriate CF", which has been defined in phase I. Circumferential PV ablation will be performed orderly, "isolated segment"," acute reconnected segment ", and "unisolated segment" will be also identified as described in phase I.

Endpoint: bi-directional block between LA-PV, and no capture along CPVI line. Parameters recording: total procedure time, model reconstruction time, power, ablation time, impedance, CF, FTI.

Usual ablation group:

Operator will be blinded to CF data, the procedure performance is the same as described in phase I.

Follow-up Warfarin or new oral anticoagulants will be administered to all patients for at least 3months after the procedure. The international normalized ratio will be controlled between 2.0 and 3.0 if warfarin prescribed.

After discharge, patients will be followed up at 1, 3, 6, 9, 12months post ablation. Patients' experiences, 12-lead electrocardiograms (ECGs) and Holter monitoring (non-required at 1, 9 months) will be recorded to evaluate recurrence at each appointment (not including 1 and 3 month visit post procedure) and any visits when the patient experience symptoms that suggestive of arrhythmia. The first 3 months is considered as a blanking period.

Recurrence is defined as AF/flutter/tachycardia, lasting longer than 30s, that documented by an ECG or Holter recording, or highly suggestive symptoms, after 3 months post-procedure.

Primary end point: Freedom from AF recurrence on the ECGs and Holter monitoring at each visit during the period from 3 months to 1 years after procedure, independent of antiarrhythmic drug(AAD) therapy.

Secondary end points: (1) Freedom from AF recurrence, dependent of AAD therapy; (2)Freedom of arrhythmia-related symptoms; (3)Safety Outcomes, contain mortality (death overall and procedure-related), vascular access complications (bleeding, hematoma, pseudoaneurysm, arteriovenous fistula), periprocedural events (stroke, transient ischemic attack, cardiac tamponade, pulmonary embolism, deep vein thrombosis, other embolism, LA-esophageal fistula, Other fistula, pericardial effusion, PV stenosis, atrioventricular block, heart failure exacerbation, need for a pacemaker, phrenic nerve injury, acute coronary artery occlusion, valve injury).

Follow-up will terminate after a maximum follow-up period of 12 months. Data Management Requirements for investigators on data entry The investigator ensures that data are entered into the medical records and the Case Report Forms (CRFs) truthfully, precisely, completely, timely and legally.

Information on all patients who signed the Informed Consent Form and enter the trial when considered eligible through screening should be closely observed and recorded in the CRFs without any field left blank or missing.

All data on the CRFs should be checked against the source records for consistency.

As source documents, the CRFs should be revised only by drawing a single line with the investigator's signature and date of revision added.

Source laboratory test reports (or their copies) should be adhered to the field for adhering laboratory test reports in the medical records.

Data that are significantly high or low or outside the clinically acceptable range should be carefully verified and reviewed, and necessary explanations should be given by the investigator.

Requirements for monitors on data monitoring The monitors should pay regular visits to the sites to examine the status of signing of informed consent, screening and enrollment.

Ensure that all the CRFs are correctly filled out and are consistent with the source data.

Ensure that all the errors or missing data have been corrected or explained, and have been signed and dated by the investigator.

Changes in treatment, concomitant medications, intercurrent conditions and ECG recording should be confirmed and recorded for each subject.

Discontinuations and loss-to-follow-ups of each subject should be indicated in the CRFs.

Confirm that all the adverse events (AEs) have been filed. Establishment of database and data entry Establishment of database:A study-specific database system will be established as per the items on the CRF.

Data entry: Data will be entered concurrently by data managers through double entry.

Data review: Each data item should be verified and the discrepancies be reported. The source forms should be verified on an item-by-item basis and the errors be corrected.

In case of any doubt during data entry, the data manager may fill out a Data Query Form which will be returned to the monitor. When the investigator has resolved in writing the queries in the query form and signed, the form will be sent back to the data managers. Data Query Forms should be appropriately stored.Selection and withdrawal of subjects

Statistical analysis Phase I For each segment, single variable and multiple regression analysis will be performed between the three groups ("isolated segment"," acute reconnected segment ", and "unisolated segment"), to define an "appropriate CF". The sensitivity and specificity of the "appropriate CF" will be analyzed.

Phase II Log-rank test will be used for inter-group comparison of recurrence. Kaplan-Meier method will be used for the estimation of currency curves for all points. When considering the central effects and the important prognostic factors, Cox proportional risk model will be used to estimate the risks compared with blank with the confidence intervals.

More data for "initially-isolated segment", "initially- nonisolated segment", and "additionally-isolated segment" will be collected, and the "appropriated CF" will be re-analyzed.

Being tested
The operator blinded to the contact force data or not.
Keywords
atrial fibrillation, Catheter Ablation, contact force, Chinese-specific
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The operator blinded to the contact force data or not.Behavioural

    CF guided group: ablation will be performed with the guidance of real-time CF, ablation time, FTI, etc. CF will be controlled in the range of "appropriate CF", which has been defined in phase I. Circumferential PV ablation will be performed orderly, "isolated segment"," acute reconnected segment ", and "unisolated segment" will be also identified as described in phase I.

    Usual ablation group:

    Operator will be blinded to CF data, the procedure performance is the same as described in phase I.

Study groups in NCT02493075
Study groupRoleWhat they receive
CF guided groupExperimentalAblation will be performed with smart-touch catheter.The operator will kown the real-time contact force (CF), ablation time, FTI, etc during the procedure.
Receives: Behavioral: The operator blinded to the contact force data or not.
Usual ablation groupActive comparatorAlthough we use the same catheter,operator will be blinded to CF data during the procedure.
Receives: Behavioral: The operator blinded to the contact force data or not.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Atrial fibrillation (AF) recurrence rate

    Patients will be followed up at 1, 3, 6, 9, 12months post ablation. Patients' experiences, 12-lead electrocardiograms (ECGs) and Holter monitoring (non-required at 1, 9 months) will be recorded to evaluate recurrence at each appointment (not including 1 and 3 month visit post procedure) and any visits when the patient experience symptoms that suggestive of arrhythmia. The first 3 months is considered as a blanking period.Recurrence is defined as AF/flutter/tachycardia, lasting longer than 30s, that documented by an ECG or Holter recording, or highly suggestive symptoms, after 3 months post-procedure.

    Measured: one year

Secondary outcomes (2)
  1. Time Data related with procedure

    Total procedure time, model reconstruction time, ablation time.

    Measured: intraoperative

  2. Number of participants with Mortality and complications

    Safety Outcomes, contain mortality (death overall and procedure-related), vascular access complications (bleeding, hematoma, pseudoaneurysm, arteriovenous fistula), periprocedural events (stroke,cardiac tamponade, pulmonary embolism, deep vein thrombosis, other embolism, LA-esophageal fistula, Other fistula, pericardial effusion, PV stenosis, atrioventricular block, heart failure exacerbation, need for a pacemaker, phrenic nerve injury, acute coronary artery occlusion, valve injury).

    Measured: one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Jul 2015 (estimated)
  2. Study startMar 2015
  3. Primary completionJan 2018 (estimated)
  4. Study completionJun 2018 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 1/2
Primary purpose
Screening
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Investigator
Enrolment
140 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02493075
Sponsor's protocol ID
IIs-304
Status last verified
Jul 2015
First submitted
25 Jun 2015
Last updated
9 Jul 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A Phase 1/2 study testing The operator blinded to the contact force data or not. in people with Atrial Fibrillation, run by Sir Run Run Shaw Hospital at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Jul 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this combined phase mean?

Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Chenyang Jiang, MD (+86 13857190051, jiangchenyang@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Atrial fibrillation (AF) recurrence rate (time frame: one year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jul 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in