AzTrials
AzTrials

Aortic Valve StenosisPhase 4PNPNCT02498639

The Pacing vs No Pacing Study - PNP Study

A Phase 4 study testing percutaneous balloon aortic valvuloplasty in people with Aortic Valve Stenosis, run by IRCCS Azienda Ospedaliero-Universitaria di Bologna at 1 site in Italy.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Pilot interventional study, without drug, randomized 1: 1, open-label comparison of efficacy and safety between the technique of percutaneous balloon aortic valvuloplasty without rapid ventricular pacing vs valvuloplasty during rapid ventricular pacing (using a temporary pacemaker device with CE mark). Read more about this study

Who is it for?
Ages 70 years and older
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
percutaneous balloon aortic valvuloplasty
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteItaly
Study dates
Apr 2015to Jan 2016
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 70 years and older
  • All sexes
  • No healthy volunteers
  • Older adult

Who may be able to join

  • diagnosis of severe symptomatic aortic valve stenosis.
  • no immediate indication to aortic valve replacement (AVR).
  • indication to balloon aortic valvuloplasty (BAV).
  • written expression of informed consent.

Who cannot join

  • clinical presentation in cardiogenic shock at the time of BAV.
  • clinical presentation in acute pulmonary edema not previously stabilized by medical therapy.

Trial locations and contacts

1 site in 1 country.

Antonio Marzocchi, MD contact

00390512144475

antonio.marzocchi@tin.it

Francesco Saia, MD contact

00390512144475

francescosaia@hotmail.com

Italy1 site, 1 recruiting
  • Institute of Cardiology, Azienda Ospedaliero-Universitaria di Bologna

    Bologna, 40138

    Francesco Saia, MD, 00390512144475, francescosaia@hotmail.com

    Gianni Dall'Ara, MD, 00390512144475, dallara.gianni@gmail.com

    Recruiting

Other trials in Italy

About this study

Official title: Comparison of Safety and Efficacy of Percutaneous Balloon Aortic Valvuloplasty Performed With or Without Rapid Ventricular Pacing - The Pacing vs No Pacing Study (PNP Study)

Pilot interventional study, without drug, randomized 1: 1, open-label comparison of efficacy and safety between the technique of percutaneous balloon aortic valvuloplasty without rapid ventricular pacing vs valvuloplasty during rapid ventricular pacing (using a temporary pacemaker device with CE mark). It is expected to enroll 100 patients. Randomization is done through a dedicated computer program.

Read the detailed description

The aim is to compare, in terms of procedural success and safety, the procedure of percutaneous balloon aortic valvuloplasty (BAV) without rapid ventricular pacing with the same procedure carried out with the aid of rapid ventricular pacing.

It is a pilot study with the objective to enroll 100 consecutive patients matching inclusion and exclusion criteria who are randomized 1:1 in two arms: in the first patients undergo procedure of BAV without rapid pacing, in the second BAV with rapid ventricular pacing able to help in balloon stabilization during inflations.

Efficacy will be studied analysing changes in transvalvular gradient from baseline to post-BAV. Safety outcomes will be collected both at discharge and at 30-day. Other procedural data will be object of direct comparison.

Being tested
percutaneous balloon aortic valvuloplasty
Keywords
balloon aortic valvuloplasty, rapid ventricular pacing, outcome
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • percutaneous balloon aortic valvuloplastyProcedure or surgery

    Percutaneous BAV is performed according to the standard retrograde technique. The measurement of the trans-aortic gradient is given by two catheters placed one in the left ventricle, the other in ascending aorta. An extra stiff wire is placed in the left ventricular cavity. A balloon (size fitting the valve annulus) is inserted over the wire and a series of three inflations is performed at nominal pressure.

    The procedure terminates in case of:

    1. Reduction of the mean aortic gradient ≥50%.
    2. Aortic pressure drop during the inflations, indicative of valve orifice sealing.
    3. Intraprocedural complication.
    4. Poor compliance of the patient. If none is met, the balloon is changed with a bigger one and a new series of three inflations performed. Aortic gradient is finally recorded.
Study groups in NCT02498639
Study groupRoleWhat they receive
BAV without pacingActive comparatorPatients undergo percutaneous balloon aortic valvuloplasty (BAV) without previous insertion of a temporary pacemaker lead in the right ventricle. Stabilization of the balloon during inflation is done without rapid pacing.
Receives: Procedure: percutaneous balloon aortic valvuloplasty
BAV with pacingActive comparatorPatients undergo percutaneous balloon aortic valvuloplasty (BAV) after previous insertion of a temporary pacemaker lead in the right ventricle. Stabilization of the balloon during inflation is done under rapid pacing.
Receives: Procedure: percutaneous balloon aortic valvuloplasty

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Efficacy endpoint: trans-aortic gradient reduction ≥ 50% measured with echocardiography from baseline to post BAV (analysis intention to treat).

    Echocardiography performed 30 minutes after the procedure.

    Measured: Post-procedural, on average 30 minutes after the procedure.

  2. Composite safety endpoint: death, myocardial infarction, stroke, acute aortic valve insufficiency, major bleeding (BARC classification ≥3)

    Measured: 30-day

Secondary outcomes (12)
  1. Trans-aortic gradient reduction ≥ 50% measured with echocardiography from baseline to post BAV (analysis per treatment).

    Echocardiography performed 30 minutes after the procedure.

    Measured: Post-procedural, on average 30 minutes after the procedure.

  2. Trans-aortic gradient reduction from 30 to 49%

    Echocardiography performed 30 minutes after the procedure.

    Measured: Post-procedural, on average 30 minutes after the procedure.

  3. Haemodynamic trans-aortic gradient reduction ≥ 50%

    Measured: Just after last balloon inflation, on average 3 minutes after BAV

  4. Haemodynamic trans-aortic gradient reduction from 30 to 49%

    Measured: Just after last balloon inflation, on average 3 minutes after BAV

  5. Overall mortality

    Measured: 30-day

  6. Cardiovascular mortality

    Measured: 30-day

  7. Ictus incidence

    Measured: 30-day

  8. Acute myocardial infarction

    Measured: 30-day

  9. Acute severe aortic insufficiency

    Measured: Just after last balloon inflation, on average few seconds after BAV

  10. Major bleeding (BARC ≥3)

    Measured: 30-day

  11. New cardiovascular hospital admission

    Measured: 30-day

  12. Evaluation of variations of the aortic valve area, and the maximum and averageaortic gradient by echocardiography from pre to post procedure

    Measured: Post-procedural, on average 30 minutes after the procedure.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Jul 2015 (estimated)
  2. Study startApr 2015
  3. Primary completionDec 2015 (estimated)
  4. Study completionJan 2016 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02498639
Sponsor's protocol ID
CE41/2015/O/Sper
Acronym
PNP
Status last verified
Jul 2015
First submitted
10 Jul 2015
Last updated
15 Jul 2015
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing percutaneous balloon aortic valvuloplasty in people with Aortic Valve Stenosis, run by IRCCS Azienda Ospedaliero-Universitaria di Bologna at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 15 Jul 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Antonio Marzocchi, MD (00390512144475, antonio.marzocchi@tin.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Efficacy endpoint: trans-aortic gradient reduction ≥ 50% measured with echocardiography from baseline to post BAV (analysis intention to treat). (time frame: Post-procedural, on average 30 minutes after the procedure.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jul 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in