Breast CancerNCT02505698
A Data Collection Study for the Evaluation of a Novel Infra-red Breast Imaging System for Risk Assessment
An observational study of Breast Cancer, run by Real Imaging Ltd. at 1 site in Israel.
Trial summary
Three-dimensional functional Metabolic Imaging (3D MIRA) is a new infrared imaging technology using the Real Imager 8 (RI8) developed by Real Imaging. This technology generates 3D metabolic maps of the breast and based on sophisticated machine learning technology, provides objective risk assessment for the presence of… Read more about this study
- Who is it for?
- Ages 30 to 80 years, women onlyHealthy volunteers can take part
- Conditions the study is for
- Breast Cancer
- How many people
- 0 participants
- Where
- 1 siteIsrael
- Study dates
- Oct 2015to Oct 2015
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 30 to 80 years
- Women only
- Healthy volunteers accepted
- Adult, Older adult
Study population: Women aged 30 years and older, and who regardless of this clinical trial are summoned for routine breast cancer screening exam or breast biopsy due to suspicious finding in recent screening exam.
Who may be able to join
- Female
- Woman has read, understood and signed the inform consent form
- Age: 30 years and older
- Women who are asymptomatic and are scheduled to undergo routine Mx and/or US screening OR Women summoned for breast biopsy following a suspicious finding in recent screening exam and was graded 4/5/6 on BI-RADS scale
Who cannot join
- Women who have had a Mx (mammography) and/or US and/or MRI examination performed on the day of the study prior to MIRA scan
- Women who had a lumpectomy surgery preceding the study
- Women who had undergone mastectomy and/or breast reconstruction
- Women who have undergone any type of breast surgery preceding the study
- Women who have had a breast biopsy performed throughout the 10 weeks preceding the study
- Women who have a fever on the day of the MIRA imaging
Show all 11Show fewer
- Women who are pregnant
- Women who are breast-feeding
- Women with implanted pacemaker/defibrillator, implanted venous access device (portacath) or other implanted devices in the chest area
- Women who are unable to read, understand and execute written informed consent
- Women who are have had chemotherapy and/or radiotherapy throughout the 6 months preceding the study
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Data Collection Study for the Evaluation of Real Imaging's Real Imager 8 (RI-8) Developed for Risk Assessment of Breast Cancer
Three-dimensional functional Metabolic Imaging (3D MIRA) is a new infrared imaging technology using the Real Imager 8 (RI8) developed by Real Imaging. This technology generates 3D metabolic maps of the breast and based on sophisticated machine learning technology, provides objective risk assessment for the presence of malignant tumor in the breast. The procedure is non-invasive, comfortable and does not involve ionizing radiation. It is based on acquiring infrared images of the breast. Those images are processed and analyzed by computers to provide the objective risk assessment.
The technology is intended to be used as a screening tool for breast cancer and emerges as highly useful in women for whom screening mammography is sub-optimal, such as women with dense breast. 3D MIRA is unaffected by breast density and is therefore ideal for evaluating patients with mammographically dense breasts.
Read more
Real Imaging is continuously developing the technology including image acquisition hardware and objective analysis of the imaging biomarkers. To further improve and optimize this novel metabolic imaging technology, Real Imaging will introduce an improved imaging device.
The purpose of this clinical study is to collect more imaging data in order to establish superiority of the newer device over the previous one.
The investigators hypothesize is that the new device will be at least as good as the previous one.
Read the detailed description
Breast cancer remains a leading cause of cancer death among women, with an estimated 1 million new cases and over 400,000 deaths annually worldwide.
In recent years, however, improvements in survival rate have been attributed to earlier diagnosis by national screening programs and better treatments. Although mammography has been the main screening modality of early detection, its limitations such as difficulty in interpreting mammograms for woman with dense breast, are well recognized and the search for more effective technologies for early detection has been receiving increased attention.
Previous studies showed that US (Ultra Sound) can detect more breast cancers not seen on Mammography, particularly in dense breasts. However, breast US sensitivity is not very high and it is highly operator-dependent.
As opposed to US, Breast MRI is highly sensitive, however, it is not used as a screening tool for the general population. The high cost of MRI, its relatively low specificity (true negative rate), its being time consuming and its need for intravenous contrast agent make it unsuitable as a breast screening tool for the general population.
In light of these shortcomings, the use of the existing screening modalities described that are based on anatomical imaging will result in some misdiagnosis of cancer, particularly in women with dense breast tissue.There is a real need for a novel breast imaging technology that may outperform the current modalities available for women.
The use of infrared imaging for breast cancer screening is an appealing concept, as it is non-invasive, involves no ionization radiation, requires no breast compression and is not affected by breast density. Infrared imaging in the form of thermography, has been utilized in the past for breasts cancer screening with limited success. Detection of thermal asymmetry between breasts, that can point to cancerous tissue, is laborious and inaccurate when examining temperature coded images. Moreover, small focal thermal variations between the breasts causes frequent misdiagnosis.
Real Imaging developed a new infrared imaging technology called 3D MIRA ,(Three-dimensional functional Metabolic Imaging and Risk Assessment) using medical device, Real Imager 8 (RI8). The MIRA technology generates three-dimensional (3D) infrared (IR) metabolic maps of the breast and developed to enable efficient, automated computer analysis of those metabolic maps.
Metabolic imaging will detect signatures of the cancer's microenvironment (e.g angiogenesis). A breast with malignant tumor behaves differently from a healthy breast. In this regard, the breast tumor has specific signatures on the surface of the breast even if the tumor is deeply embedded inside. Metabolic imaging can overcome the limitations of current mammography screening for women with dense breasts. The infrared signal contains information on both anatomical structures and metabolic processes within the breast.
Based on those infrared signals MIRA technology can provide an objective risk assessment for the presence of malignant tumor. The risk assessment is an index that represents the likelihood that a given image dataset includes a malignant finding. The index scale ranges from -100 (normal) to 100 (abnormal). The risk model is based on training the parameters on a calibration set of clinically known cases.
The Real Imager 8.0 (RI8) is composed of two optical heads, each of which includes infrared camera digital camera and video projector. RI8 offers a non-invasive method for Metabolic Imaging and Risk Assessment (MIRA). The RI8 scan enables the determination of risk for breast cancer malignancy, based on assessment of several metabolic parameters. The device does not provide diagnosis or location of cancer. It will offer the physician a support tool to guide the patient to further imaging workup in order to locate, diagnose and characterize the tumor.
The Imaging process is as follows:
The imager is positioned at a distance of approximately 70 cm from the subject who is seated upright throughout the examination. This position will be maintained throughout the imaging session. An initial period of temperature equilibrium precede the imaging process, during which the patient sits in the dedicated imaging room with room temperature set at 18-22 degrees Celsius. Following the temperature equilibration phase, continuous infrared imaging will be acquired for a period of up to 7 minutes. Two minutes after beginning of infrared recording, a metabolic stress test will be induced by having the patient wear cold gloves (0-5 degrees Celsius), which will be removed after 1 minute. This is performed for the purpose of generating vasoconstriction in the breast vessels. The entire imaging session will last approximately 22 minutes. The procedure is comfortable, non-invasive and does not emit or involves any ionizing radiation.
Real Imaging is continuously developing the technology including image acquisition hardware and objective analysis of the imaging biomarkers. To further improve and optimize this novel metabolic imaging technology, Real Imaging will introduce an improved imaging device.
Improvements over the previous approved prototype device include higher resolution and frequency.
Therefore there is a need to collect more imaging data in order to establish superiority of the newer device over the previous one.
The Imaging data will not be used to assess the clinical health status of the volunteers. Data collected during this study is part of Real Imaging's ongoing research and development efforts aimed to create a more effective screening modality for breast cancer.
In this data collection study, approximately 300 female subjects will be enrolled at The Breast Imaging Unit of the Tel-Aviv Medical Center. MIRA's risk assessment will not be provided to the physician nor the subject.
In order to evaluate MIRA's ability to classify healthy women from those who have breast cancer, the enrollment will include two groups:
- Screening Group - healthy women with no breast findings in previous screening exams
- Pre-Biopsy Group - women with suspicious findings on recent Mammography and/or US and/or MRI exams with BI-RADS (Breast Imaging-Reporting and Data System) 4/5/6 who are summoned for biopsy for further workup.
Eligible recruited subjects who have signed an informed consent will undergo MIRA imaging prior to being imaged by any other conventional imaging method and if relevant, prior to undergoing a breast biopsy.
MIRA's data of every individual patient will be used for development purposes. The subject's personal, medical, diagnostic examination information and pathology results will be recorded in CRF (case report form) specially designed for this study. Each subject's clinical information will be followed up in order to validate MIRA's results.
- Conditions
- Breast Cancer
- Keywords
- Breast Imaging, Mammography, Anatomical Imaging
- Medical subject headings
- Breast Neoplasms
What is being measured
The primary outcome is the main question the study is designed to answer.
Sufficient number of cancer case and controls have been imaged
As this is a data collection study, end point will be reached when approximately 50 women with breast cancer and 100 healthy women (controls) are imaged by the device and sufficient for the comparison statistical analysis.
Measured: up to 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Jul 2015 (estimated)
- Study startOct 2015
- Primary completionOct 2015
- Study completionOct 2015
Why it stopped: Study initiation at this site fell through
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Breast CancerStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case-control
- Time perspective
- Prospective
- Enrolment
- 0 participants (actual)
Sponsor and investigators
- Lead sponsor
- Real Imaging Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Orit Golan, MD, Principal investigator, The Breast Imagning Unit at Tel Aviv Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02505698
- Sponsor's protocol ID
- 960-CLP-ISR-IR8
- Status last verified
- Mar 2017
- First submitted
- 4 May 2015
- Last updated
- 11 Apr 2018
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 11 Apr 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Data Collection Study for the Evaluation of Real Imaging's Real Imager 8 (RI-8) Developed for Risk Assessment of Breast Cancer
- ClinicalTrials.gov ID
- NCT02505698
- Acronym / sponsor ID
- 960-CLP-ISR-IR8
- Conditions
- Breast Cancer
- Keywords
- Breast Imaging, Mammography, Anatomical Imaging
- Study type
- Observational
- Recruitment status
- WithdrawnReason stopped: Study initiation at this site fell through
- Enrolment
- 0 participants (actual)
- Lead sponsor
- Real Imaging Ltd.Industry (pharma, biotech, devices)
- Study start
- Oct 2015 (actual)
- Primary completion
- Oct 2015 (actual)
- Study completion
- Oct 2015 (actual)
- First posted
- 22 Jul 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Three-dimensional functional Metabolic Imaging (3D MIRA) is a new infrared imaging technology using the Real Imager 8 (RI8) developed by Real Imaging. This technology generates 3D metabolic maps of the breast and based on sophisticated machine learning technology, provides objective risk assessment for the presence of malignant tumor in the breast. The procedure is non-invasive, comfortable and does not involve ionizing radiation. It is based on acquiring infrared images of the breast. Those images are processed and analyzed by computers to provide the objective risk assessment.
The technology is intended to be used as a screening tool for breast cancer and emerges as highly useful in women for whom screening mammography is sub-optimal, such as women with dense breast. 3D MIRA is unaffected by breast density and is therefore ideal for evaluating patients with mammographically dense breasts.
Real Imaging is continuously developing the technology including image acquisition hardware and objective analysis of the imaging biomarkers. To further improve and optimize this novel metabolic imaging technology, Real Imaging will introduce an improved imaging device.
The purpose of this clinical study is to collect more imaging data in order to establish superiority of the newer device over the previous one.
The investigators hypothesize is that the new device will be at least as good as the previous one.
Detailed description
Breast cancer remains a leading cause of cancer death among women, with an estimated 1 million new cases and over 400,000 deaths annually worldwide.
In recent years, however, improvements in survival rate have been attributed to earlier diagnosis by national screening programs and better treatments. Although mammography has been the main screening modality of early detection, its limitations such as difficulty in interpreting mammograms for woman with dense breast, are well recognized and the search for more effective technologies for early detection has been receiving increased attention.
Previous studies showed that US (Ultra Sound) can detect more breast cancers not seen on Mammography, particularly in dense breasts. However, breast US sensitivity is not very high and it is highly operator-dependent.
As opposed to US, Breast MRI is highly sensitive, however, it is not used as a screening tool for the general population. The high cost of MRI, its relatively low specificity (true negative rate), its being time consuming and its need for intravenous contrast agent make it unsuitable as a breast screening tool for the general population.
In light of these shortcomings, the use of the existing screening modalities described that are based on anatomical imaging will result in some misdiagnosis of cancer, particularly in women with dense breast tissue.There is a real need for a novel breast imaging technology that may outperform the current modalities available for women.
The use of infrared imaging for breast cancer screening is an appealing concept, as it is non-invasive, involves no ionization radiation, requires no breast compression and is not affected by breast density. Infrared imaging in the form of thermography, has been utilized in the past for breasts cancer screening with limited success. Detection of thermal asymmetry between breasts, that can point to cancerous tissue, is laborious and inaccurate when examining temperature coded images. Moreover, small focal thermal variations between the breasts causes frequent misdiagnosis.
Real Imaging developed a new infrared imaging technology called 3D MIRA ,(Three-dimensional functional Metabolic Imaging and Risk Assessment) using medical device, Real Imager 8 (RI8). The MIRA technology generates three-dimensional (3D) infrared (IR) metabolic maps of the breast and developed to enable efficient, automated computer analysis of those metabolic maps.
Metabolic imaging will detect signatures of the cancer's microenvironment (e.g angiogenesis). A breast with malignant tumor behaves differently from a healthy breast. In this regard, the breast tumor has specific signatures on the surface of the breast even if the tumor is deeply embedded inside. Metabolic imaging can overcome the limitations of current mammography screening for women with dense breasts. The infrared signal contains information on both anatomical structures and metabolic processes within the breast.
Based on those infrared signals MIRA technology can provide an objective risk assessment for the presence of malignant tumor. The risk assessment is an index that represents the likelihood that a given image dataset includes a malignant finding. The index scale ranges from -100 (normal) to 100 (abnormal). The risk model is based on training the parameters on a calibration set of clinically known cases.
The Real Imager 8.0 (RI8) is composed of two optical heads, each of which includes infrared camera digital camera and video projector. RI8 offers a non-invasive method for Metabolic Imaging and Risk Assessment (MIRA). The RI8 scan enables the determination of risk for breast cancer malignancy, based on assessment of several metabolic parameters. The device does not provide diagnosis or location of cancer. It will offer the physician a support tool to guide the patient to further imaging workup in order to locate, diagnose and characterize the tumor.
The Imaging process is as follows:
The imager is positioned at a distance of approximately 70 cm from the subject who is seated upright throughout the examination. This position will be maintained throughout the imaging session. An initial period of temperature equilibrium precede the imaging process, during which the patient sits in the dedicated imaging room with room temperature set at 18-22 degrees Celsius. Following the temperature equilibration phase, continuous infrared imaging will be acquired for a period of up to 7 minutes. Two minutes after beginning of infrared recording, a metabolic stress test will be induced by having the patient wear cold gloves (0-5 degrees Celsius), which will be removed after 1 minute. This is performed for the purpose of generating vasoconstriction in the breast vessels. The entire imaging session will last approximately 22 minutes. The procedure is comfortable, non-invasive and does not emit or involves any ionizing radiation.
Real Imaging is continuously developing the technology including image acquisition hardware and objective analysis of the imaging biomarkers. To further improve and optimize this novel metabolic imaging technology, Real Imaging will introduce an improved imaging device.
Improvements over the previous approved prototype device include higher resolution and frequency.
Therefore there is a need to collect more imaging data in order to establish superiority of the newer device over the previous one.
The Imaging data will not be used to assess the clinical health status of the volunteers. Data collected during this study is part of Real Imaging's ongoing research and development efforts aimed to create a more effective screening modality for breast cancer.
In this data collection study, approximately 300 female subjects will be enrolled at The Breast Imaging Unit of the Tel-Aviv Medical Center. MIRA's risk assessment will not be provided to the physician nor the subject.
In order to evaluate MIRA's ability to classify healthy women from those who have breast cancer, the enrollment will include two groups:
- Screening Group - healthy women with no breast findings in previous screening exams
- Pre-Biopsy Group - women with suspicious findings on recent Mammography and/or US and/or MRI exams with BI-RADS (Breast Imaging-Reporting and Data System) 4/5/6 who are summoned for biopsy for further workup.
Eligible recruited subjects who have signed an informed consent will undergo MIRA imaging prior to being imaged by any other conventional imaging method and if relevant, prior to undergoing a breast biopsy.
MIRA's data of every individual patient will be used for development purposes. The subject's personal, medical, diagnostic examination information and pathology results will be recorded in CRF (case report form) specially designed for this study. Each subject's clinical information will be followed up in order to validate MIRA's results.
Study design
- Observational model
- Case-control
- Time perspective
- Prospective
Who may qualify
- Ages
- 30 to 80 years
- Sex
- Female only
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Women aged 30 years and older, and who regardless of this clinical trial are summoned for routine breast cancer screening exam or breast biopsy due to suspicious finding in recent screening exam.
Key inclusion criteria (4 listed)
- Female
- Woman has read, understood and signed the inform consent form
- Age: 30 years and older
- Women who are asymptomatic and are scheduled to undergo routine Mx and/or US screening OR Women summoned for breast biopsy following a suspicious finding in recent screening exam and was graded 4/5/6 on BI-RADS scale
Key exclusion criteria (11 listed)
- Women who have had a Mx (mammography) and/or US and/or MRI examination performed on the day of the study prior to MIRA scan
- Women who had a lumpectomy surgery preceding the study
- Women who had undergone mastectomy and/or breast reconstruction
- Women who have undergone any type of breast surgery preceding the study
- Women who have had a breast biopsy performed throughout the 10 weeks preceding the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Sufficient number of cancer case and controls have been imaged
Time frame: up to 12 months
As this is a data collection study, end point will be reached when approximately 50 women with breast cancer and 100 healthy women (controls) are imaged by the device and sufficient for the comparison statistical analysis.
Results and safety
The study was withdrawn before enrolling participants, so there are no results.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 11 Apr 2018.
Related trials for Breast Cancer
Not yet recruiting
Effect of a Health Belief Model Based Digital Nudge Intervention on Breast Cancer Screening
Breast Cancer Screening, Breast Cancer Awareness
Active, not recruitingPhase 1/2
A Beta-only IL-2 ImmunoTherapY Study
Advanced Solid Tumor, Unresectable Solid Tumor
Not yet recruitingPhase 2
Low-Dose Apatinib Plus Chemotherapy in ADC-Pretreated HER2-Positive and HER2-Low Advanced Breast Cancer
Breast Neoplasms, Advanced Breast Cancer
RecruitingPhase 3
ROSETTA Breast-01: The Effects and Safety of Pumitamig in Patients With Triple-Negative Breast Cancer
Breast Neoplasms
Active, not recruitingPhase 2
Phase II Study of Dato-DXd in Triple-negative Breast Cancer Patients With Newly Diagnosed or Progressing Brain Metastases
Breast Cancer Stage IV
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Orit Golan, MD principal investigator
The Breast Imagning Unit at Tel Aviv Medical Center
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Breast Cancer, run by Real Imaging Ltd. at 1 site in Israel.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: withdrawn, as of the sponsor's last update on 11 Apr 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Israel. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was withdrawn before enrolling participants, so there are no results.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Sufficient number of cancer case and controls have been imaged (time frame: up to 12 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Apr 2018.