Atrial FibrillationUniforceNCT02520960
Unipolar Atrial Electrogram Modification Combined to the Contact Force Sensing Technology for Pulmonary Vein Isolation
An observational study of Atrial Fibrillation and Arrhythmia, run by Hôpital Privé Les Franciscaines at 1 site in France.
Trial summary
Prospective observational multicentric study evaluating the efficacy of considering unipolar signal modification during radio frequency catheter ablation of patients with symptomatic paroxysmal atrial fibrillation in France between November 2013 and January 2015. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Atrial Fibrillation, Arrhythmia
- How many people
- 215 participants
- Where
- 1 siteFrance
- Study dates
- Nov 2013to Jan 2016
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Consecutive patients referred to the participating institutions, from November 2013 to January 2015, for catheter ablation of symptomatic and drug resistant PAF. Paroxysmal AF was considered any episode of AF that terminates spontaneously in less than seven days.
Who may be able to join
- Paroxysmal symptomatic and drug resistant atrial fibrillation (AF). Paroxysmal AF was considered any episode of AF that terminates spontaneously in less than seven days.
Who cannot join
- age <18 or >80 year-old
- left atrial volume >200 ml
- presence of a mechanical mitral valve prosthesis
- impaired thyroid function
- left ventricular ejection fraction <40%
- patient under guardianship
Show all 10Show fewer
- contraindication to anticoagulant therapy
- current malignancy
- prior catheter or surgical AF ablation
- persistent or long-standing persistent AF
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Pulmonary Vein Isolation for the Treatment of Paroxysmal Atrial Fibrillation by Combining the Analysis of the Unipolar Atrial Electrogram Modification With the Contact Force Sensing Technology: The Uniforce Study
Prospective observational multicentric study evaluating the efficacy of considering unipolar signal modification during radio frequency catheter ablation of patients with symptomatic paroxysmal atrial fibrillation in France between November 2013 and January 2015. All procedures were conducted according to the standard clinical care and current guidelines. Pulmonary vein isolation was guided according to force (at least 10 grams) and application vector (perpendicular to the wall) developed until the atrial unipolar electrogram recording became a complete positive signal. Patients were discharged from hospital free of any anti-arrhythmic drugs. Recurrence of arrhythmias at 12 months (primary outcome) was assessed by continuous 48-hour Holter at 1, 3, 6, 9 and 12 months post-catheter ablation.
Read the detailed description
Patients and Setting: Consecutive patients referred to the participating institutions, from November 2013 to January 2015, for catheter ablation of symptomatic and drug resistant paroxysmal atrial fibrillation (AF) were enrolled in this observational 12-follow up study. Paroxysmal AF was defined as any episode of AF that terminates spontaneously in less than seven days. Eligibility criteria, as well as outcome measures have been detailed in other sections.
Radiofrequency catheter ablation for AF: All procedures were conducted according to the standard clinical care and North American and European guidelines. Of note, the investigators did not assign specific interventions to the subjects of the study, and all interventions (trans-oesophageal echocardiography, pulmonary vein isolation) are recommended by American Heart Association and European Society of Cardiology. AF catheter ablation were conducted under efficient vitamin K antagonists (INR 2-3) and general anesthesia without discontinuation of anti-arrhythmic drugs (AAD). Trans-esophageal echocardiography was performed for each patient within 48 hours before the procedure to exclude any intra-cardiac thrombi. Two long sheaths (Preface™, Biosense Webster, Diamond Bar, CA or SLO™, Saint Jude Medical, Minnetonka, MN) were advanced into the LA after two trans-septal punctures. Intravenous heparin was administered with a target activated clotting time beyond 320 seconds. Three catheters, inserted through the right femoral vein, were used for mapping and ablation: a 6F non deflectable hexapolar 2.5-2.5-2.5-2.5-247.5 mm interspacing electrodes catheter placed at the high right atrium (RA) or into the coronary sinus (CS) whenever possible (Curve: A-Josephson type, Biosense Webster), with its proximal electrode placed at the level of the inferior vena cava, a 7F circular decapolar mapping catheter (Lasso™) placed into the LA through one of the constantly perfused long sheaths and used to monitor PVI, and a 3.5 mm 7F externally irrigated-tip ablation contact force sensing catheter (SmartTouch™), placed within the LA through the second constantly irrigated long sheath. A LA anatomy shell was created with the aid of the Carto3 system (Biosense Webster). This shell was merged or not with 3D computed tomography scan acquired prior to the ablation procedure depending on operator's choice. Pulmonary veins were isolated two-by-two at their antral level by creating a continuous circular lesion. The carina regions were targeted only if PVs could not be isolated despite complete circular lesion creation around PVs ostia. Radiofrequency ablation settings used were: 30 W/48°C/17 ml per minute except for the posterior LA wall (25W/48°C/17 ml per min) and the ridge (35W/48°C/30 ml per min). Thirty minutes after PVI, entrance and exit blocks were rechecked for each PV. In case of PV reconnection, supplemental RF applications were performed in order to re-isolate PVs following a two-step approach.
Evaluation of the unipolar signal modification: every radiofrequency (RF) delivery was performed with a minimal 10 g of force, through the entire RF application and lasted 10 seconds after the unipolar atrial electrogram, recorded by the ablation catheter, which always demonstrated positive-negative morphology before ablation, became complete positive signal (except on the posterior LA wall where 5 supplemental seconds only were added). During individual RF applications, the modification of the unipolar atrial electrogram was monitored in real-time with the Carto™ system at a sweep speed of 200mm/s. Reference annotation signal was recorded from the bipolar signal of either electrodes 1-2 or 3-4 of the non-deflectable 6F hexapolar catheter, depending on whether the latter was placed into the CS or at the high RA. Unipolar signal was recorded from the 3.5mm distal electrode of the ablation catheter and was filtered on the Carto™ system with a [0.5-120] Hz band-pass filter and displayed in the Carto™ annotation viewer. The indifferent electrode was used as the cathode and was located at the level of the inferior vena cava.
Post-ablation Management and Follow-up: All patients were discharged home within 3 days, and enrolled in a 12-month follow-up. Post-procedure, AAD were discontinued while vitamin K antagonists were prescribed for 3 months. Subsequently, vitamin K antagonists were continued or not, depending on the CHA2DS2-VASc score of each patient. Patients were evaluated pre-discharge, at 1, 3, 6, 9 and 12 months post-procedure. Information collected included details of cardiac medications, NYHA functional class and history of any arrhythmias or other adverse events. In addition, a 12-lead ECG and 24-hour Holter monitoring were systematically obtained at each visit. Echocardiography was performed in all cases the day after procedure. No antiarrhythmic medication was prescribed following ablation. If there was documented recurrence of symptomatic AF during the 3-month blanking period and the patient required antiarrhythmic drug therapy, a previously ineffective but tolerated class 1 or class 3 (sotalol) drug was the preferred option. Atrial tachycardia/AF recurrence was considered, any episode lasting > 30 s (either symptomatic or asymptomatic) subsequent to a 3-month blanking period.
- Conditions
- Atrial Fibrillation, Arrhythmia
- Keywords
- Catheter Ablation, Pulmonary Vein Isolation, Radiofrequency
- Medical subject headings
- Atrial Fibrillation, Arrhythmias, Cardiac
What is being measured
The primary outcome is the main question the study is designed to answer.
Recurrence of Atrial Arrhythmias
Measured: 12 months
Secondary outcomes (1)
Frequency of Pulmonary Vein Reconnection
Recurrence of the electrical conduction between atria and pulmonary veins
Measured: 30 mins
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Aug 2015 (estimated)
- Study startNov 2013
- Primary completionJan 2016
- Study completionJan 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Atrial FibrillationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 215 participants (actual)
Sponsor and investigators
- Lead sponsor
- Hôpital Privé Les Franciscaines
- Sponsor type
- University, hospital or other
- Collaborators
- Clinique St Pierre, Perpignan, France, Clinique Ambroise Paré, Neuilly sur Seine, France, Hôpital Privé Clairval, Marseille, France, Infirmerie Protestante de Lyon, Lyon, France, Centre Hospitalo-Universitaire de Brabois, Vandoeuvre Les Nancy, France, Centre Hospitalier Régional Universitaire Montpellier, Paris Cardiovascular Research Center (Inserm U970), Clinique Pasteur
- Responsible party
- Principal investigator, Agustin Bortone, MD, Hôpital Privé Les Franciscaines
- Investigators
- Agustin Bortone, MD, Principal investigator, Service de Cardiologie, Hôpital Privé Les Franciscaines, Nîmes, France
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02520960
- Sponsor's protocol ID
- 2014-30605
- Other IDs
- 2014
- Acronym
- Uniforce
- Status last verified
- Aug 2016
- First submitted
- 4 Aug 2015
- Last updated
- 19 Aug 2016
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Bortone A, Brault-Noble G, Appetiti A, Marijon E. Elimination of the negative component of the unipolar atrial electrogram as an in vivo marker of transmural lesion creation: acute study in canines. Circ Arrhythm Electrophysiol. 2015 Aug;8(4):905-11. doi: 10.1161/CIRCEP.115.002894. Epub 2015 Jun 19.
PubMed 26092576Bortone A, Appetiti A, Bouzeman A, Maupas E, Ciobotaru V, Boulenc JM, Pujadas-Berthault P, Rioux P. Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium: prospective study in humans in the setting of paroxysmal atrial fibrillation catheter ablation. Circ Arrhythm Electrophysiol. 2013 Dec;6(6):1095-102. doi: 10.1161/CIRCEP.113.000749. Epub 2013 Oct 4.
PubMed 24097371Bortone A, Lagrange P, Cauchemez B, Durand C, Dieuzaide P, Prevot S, Mechulan A, Pambrun T, Martin R, Parlier P, Masse A, Marijon E, Albenque JP. Elimination of the negative component of the unipolar electrogram as a local procedural endpoint during paroxysmal atrial fibrillation catheter ablation using contact-force sensing: the UNIFORCE study. J Interv Card Electrophysiol. 2017 Sep;49(3):299-306. doi: 10.1007/s10840-017-0264-4. Epub 2017 Jun 22.
PubMed 28643171
Study at a glance
From the registry record, last updated by the sponsor on 19 Aug 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Pulmonary Vein Isolation for the Treatment of Paroxysmal Atrial Fibrillation by Combining the Analysis of the Unipolar Atrial Electrogram Modification With the Contact Force Sensing Technology: The Uniforce Study
- ClinicalTrials.gov ID
- NCT02520960
- Acronym / sponsor ID
- Uniforce / 2014-30605
- Conditions
- Atrial Fibrillation, Arrhythmia
- Keywords
- Catheter Ablation, Pulmonary Vein Isolation, Radiofrequency
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 215 participants (actual)
- Lead sponsor
- Hôpital Privé Les FranciscainesUniversity, hospital or other
- Collaborators
- Clinique St Pierre, Perpignan, France, Clinique Ambroise Paré, Neuilly sur Seine, France, Hôpital Privé Clairval, Marseille, France, Infirmerie Protestante de Lyon, Lyon, France, Centre Hospitalo-Universitaire de Brabois, Vandoeuvre Les Nancy, France, Centre Hospitalier Régional Universitaire Montpellier, Paris Cardiovascular Research Center (Inserm U970), Clinique Pasteur
- Study start
- Nov 2013
- Primary completion
- Jan 2016 (actual)
- Study completion
- Jan 2016 (actual)
- First posted
- 13 Aug 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Prospective observational multicentric study evaluating the efficacy of considering unipolar signal modification during radio frequency catheter ablation of patients with symptomatic paroxysmal atrial fibrillation in France between November 2013 and January 2015. All procedures were conducted according to the standard clinical care and current guidelines. Pulmonary vein isolation was guided according to force (at least 10 grams) and application vector (perpendicular to the wall) developed until the atrial unipolar electrogram recording became a complete positive signal. Patients were discharged from hospital free of any anti-arrhythmic drugs. Recurrence of arrhythmias at 12 months (primary outcome) was assessed by continuous 48-hour Holter at 1, 3, 6, 9 and 12 months post-catheter ablation.
Detailed description
Patients and Setting: Consecutive patients referred to the participating institutions, from November 2013 to January 2015, for catheter ablation of symptomatic and drug resistant paroxysmal atrial fibrillation (AF) were enrolled in this observational 12-follow up study. Paroxysmal AF was defined as any episode of AF that terminates spontaneously in less than seven days. Eligibility criteria, as well as outcome measures have been detailed in other sections.
Radiofrequency catheter ablation for AF: All procedures were conducted according to the standard clinical care and North American and European guidelines. Of note, the investigators did not assign specific interventions to the subjects of the study, and all interventions (trans-oesophageal echocardiography, pulmonary vein isolation) are recommended by American Heart Association and European Society of Cardiology. AF catheter ablation were conducted under efficient vitamin K antagonists (INR 2-3) and general anesthesia without discontinuation of anti-arrhythmic drugs (AAD). Trans-esophageal echocardiography was performed for each patient within 48 hours before the procedure to exclude any intra-cardiac thrombi. Two long sheaths (Preface™, Biosense Webster, Diamond Bar, CA or SLO™, Saint Jude Medical, Minnetonka, MN) were advanced into the LA after two trans-septal punctures. Intravenous heparin was administered with a target activated clotting time beyond 320 seconds. Three catheters, inserted through the right femoral vein, were used for mapping and ablation: a 6F non deflectable hexapolar 2.5-2.5-2.5-2.5-247.5 mm interspacing electrodes catheter placed at the high right atrium (RA) or into the coronary sinus (CS) whenever possible (Curve: A-Josephson type, Biosense Webster), with its proximal electrode placed at the level of the inferior vena cava, a 7F circular decapolar mapping catheter (Lasso™) placed into the LA through one of the constantly perfused long sheaths and used to monitor PVI, and a 3.5 mm 7F externally irrigated-tip ablation contact force sensing catheter (SmartTouch™), placed within the LA through the second constantly irrigated long sheath. A LA anatomy shell was created with the aid of the Carto3 system (Biosense Webster). This shell was merged or not with 3D computed tomography scan acquired prior to the ablation procedure depending on operator's choice. Pulmonary veins were isolated two-by-two at their antral level by creating a continuous circular lesion. The carina regions were targeted only if PVs could not be isolated despite complete circular lesion creation around PVs ostia. Radiofrequency ablation settings used were: 30 W/48°C/17 ml per minute except for the posterior LA wall (25W/48°C/17 ml per min) and the ridge (35W/48°C/30 ml per min). Thirty minutes after PVI, entrance and exit blocks were rechecked for each PV. In case of PV reconnection, supplemental RF applications were performed in order to re-isolate PVs following a two-step approach.
Evaluation of the unipolar signal modification: every radiofrequency (RF) delivery was performed with a minimal 10 g of force, through the entire RF application and lasted 10 seconds after the unipolar atrial electrogram, recorded by the ablation catheter, which always demonstrated positive-negative morphology before ablation, became complete positive signal (except on the posterior LA wall where 5 supplemental seconds only were added). During individual RF applications, the modification of the unipolar atrial electrogram was monitored in real-time with the Carto™ system at a sweep speed of 200mm/s. Reference annotation signal was recorded from the bipolar signal of either electrodes 1-2 or 3-4 of the non-deflectable 6F hexapolar catheter, depending on whether the latter was placed into the CS or at the high RA. Unipolar signal was recorded from the 3.5mm distal electrode of the ablation catheter and was filtered on the Carto™ system with a [0.5-120] Hz band-pass filter and displayed in the Carto™ annotation viewer. The indifferent electrode was used as the cathode and was located at the level of the inferior vena cava.
Post-ablation Management and Follow-up: All patients were discharged home within 3 days, and enrolled in a 12-month follow-up. Post-procedure, AAD were discontinued while vitamin K antagonists were prescribed for 3 months. Subsequently, vitamin K antagonists were continued or not, depending on the CHA2DS2-VASc score of each patient. Patients were evaluated pre-discharge, at 1, 3, 6, 9 and 12 months post-procedure. Information collected included details of cardiac medications, NYHA functional class and history of any arrhythmias or other adverse events. In addition, a 12-lead ECG and 24-hour Holter monitoring were systematically obtained at each visit. Echocardiography was performed in all cases the day after procedure. No antiarrhythmic medication was prescribed following ablation. If there was documented recurrence of symptomatic AF during the 3-month blanking period and the patient required antiarrhythmic drug therapy, a previously ineffective but tolerated class 1 or class 3 (sotalol) drug was the preferred option. Atrial tachycardia/AF recurrence was considered, any episode lasting > 30 s (either symptomatic or asymptomatic) subsequent to a 3-month blanking period.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Consecutive patients referred to the participating institutions, from November 2013 to January 2015, for catheter ablation of symptomatic and drug resistant PAF. Paroxysmal AF was considered any episode of AF that terminates spontaneously in less than seven days.
Key inclusion criteria (1 listed)
- Paroxysmal symptomatic and drug resistant atrial fibrillation (AF). Paroxysmal AF was considered any episode of AF that terminates spontaneously in less than seven days.
Key exclusion criteria (10 listed)
- age <18 or >80 year-old
- left atrial volume >200 ml
- presence of a mechanical mitral valve prosthesis
- impaired thyroid function
- left ventricular ejection fraction <40%
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Recurrence of Atrial Arrhythmias
Time frame: 12 months
1 secondary outcome
Frequency of Pulmonary Vein Reconnection
Time frame: 30 mins
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Aug 2016.
- Results publication: PubMed 26092576Bortone A, Brault-Noble G, Appetiti A, Marijon E. Elimination of the negative component of the unipolar atrial electrogram as an in vivo marker of transmural lesion creation: acute study in canines. Circ Arrhythm Electrophysiol. 2015 Aug;8(4):905-11. doi: 10.1161/CIRCEP.115.002894. Epub 2015 Jun 19.
- Results publication: PubMed 24097371Bortone A, Appetiti A, Bouzeman A, Maupas E, Ciobotaru V, Boulenc JM, Pujadas-Berthault P, Rioux P. Unipolar signal modification as a guide for lesion creation during radiofrequency application in the left atrium: prospective study in humans in the setting of paroxysmal atrial fibrillation catheter ablation. Circ Arrhythm Electrophysiol. 2013 Dec;6(6):1095-102. doi: 10.1161/CIRCEP.113.000749. Epub 2013 Oct 4.
- Derived from this study: PubMed 28643171Bortone A, Lagrange P, Cauchemez B, Durand C, Dieuzaide P, Prevot S, Mechulan A, Pambrun T, Martin R, Parlier P, Masse A, Marijon E, Albenque JP. Elimination of the negative component of the unipolar electrogram as a local procedural endpoint during paroxysmal atrial fibrillation catheter ablation using contact-force sensing: the UNIFORCE study. J Interv Card Electrophysiol. 2017 Sep;49(3):299-306. doi: 10.1007/s10840-017-0264-4. Epub 2017 Jun 22.
Related trials for Atrial Fibrillation
Active, not recruiting
VOLT CE Mark Study
Atrial Arrhythmia, Atrial Fibrillation
RecruitingObservational study
AI-Based Cardiac Analysis Using 12-Lead and 1-Lead ECG
Heart Failure, Atrial Fibrillation (AF)
RecruitingObservational study
Observational Study of Cardiac Arrhythmias During Treatment With BTK Inhibitors or Venetoclax
Chronic Lymphocytic Leukemia (CLL), Waldenstr(SqrRoot)(Delta)m s Macroglobulinemia
Not yet recruiting
CATCH AF - Atrial Fibrillation Detection in Cryptogenic Stroke
Atrial Fibrillation (AF)
Active, not recruiting
ARIADNE Clinical Trial
Persistent Atrial Fibrillation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Agustin Bortone, MD principal investigator
Service de Cardiologie, Hôpital Privé Les Franciscaines, Nîmes, France
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Atrial Fibrillation and Arrhythmia, run by Hôpital Privé Les Franciscaines at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Aug 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Recurrence of Atrial Arrhythmias (time frame: 12 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02520960, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Aug 2016.