Trial summary

Thermodilution cardiac output measurement is a reliable method, but it is an invasive one. PiCCO device requires cannulation of central vein and peripheral artery. Impedance method requires only attachment of special electrodes. Non-invasive methods are less accurate. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiovascular Diagnostic Techniques
What is being tested?
PICCO and NICCOMO
Type of treatment
Medical device
How many people
50 participants
Where
1 sitePoland
Study dates
May 2014to Mar 2021
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: patients treated in intensive therapy unit, mechanically ventilated, haemodynamics monitored with PiCCO technique

Who may be able to join

  • critically ill patients
  • patients on mechanical ventilation
  • circulatory insufficiency (present or in the past) monitored with with PiCCO device

Who cannot join

  • morbid obesity,
  • short neck,
  • severe pneumonia,
  • inability to NICCOMO electrodes attachment,
  • massive tissue oedema,
  • non-sinus cardiac rhythm,
Show all 15Show fewer
  • tachycardia,
  • low cardiac output,
  • septic shock,
  • heart valve pathologies,
  • severe atherosclerosis,
  • aortic prosthesis,
  • severe hypertension,
  • extremes of height and weight,
  • intraaortic pump

Trial locations and contacts

1 site in 1 country.

Magdalena A Wujtewicz contact

+48583493357

magwuj@gumed.edu.pl

Radoslaw Owczuk contact

605408140

r.owczuk@gumed.edu.pl

Poland1 site, 1 recruiting
  • Medical University of Gdansk

    Gdansk, 80-214

    Magdalena A Wujtewicz, +48583493357, magwuj@gumed.edu.pl

    Radoslaw Owczuk, 605408140, r.owczuk@gumed.edu.pl

    Recruiting

Other trials in Poland

About this study

Official title: Assessment of Reliability of Cardiac Output Measurement Based on Impedance (NICCOMO) - Method of Noninvasive Cardiac Output Measurement, Compared to Transthoracic Thermodilution (PiCCO) at Different PEEP Levels

Thermodilution cardiac output measurement is a reliable method, but it is an invasive one. PiCCO device requires cannulation of central vein and peripheral artery. Impedance method requires only attachment of special electrodes. Non-invasive methods are less accurate. Aim of study is to assess accuracy and reliability of impedance method ( using NICCOMO device) in comparison of thermodilution method ( using PiCCO device) at different PEEP levels.

Read the detailed description

Echocardiography is performed prior to measurement to exclude patients with heart valve abnormalities.

Patients without spontaneous ventilation ( deeply unconscious, sedated or sedated and paralysed), ventilated with controlled mechanical ventilation mode with tidal volume 6-8 ml/ideal body weight, resulting in EtCO2 35-45 mmHg, with PiCCO catheters implemented have additionally NICCOMO device attached. Fraction of inspired oxygen (FiO2) is set to achieve saturation >96% at positive end expiratory pressure (PEEP) 0 cmH2O.

Measurement of cardiac output are performed on expiration at PEEP 0, 5, 10, 15 20 cmH2O and at optimal PEEP (obtained from P-V curve). Simultaneously CO value from impedance device is noted. Other haemodynamic parameters, calculated by both devices are also noted - stroke volume (SV), stroke volume variation (SVV), Cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI).

Being tested
PICCO, NICCOMO

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • PICCODevice

    measurements based on thermodilution

  • NICCOMODevice

    measurements based on impedance

Study groups in NCT02572739
Study groupRoleWhat they receive
haemodynamics measuringthose with already implemented PICCO device get impedance device (NICCOMO) attached
Receives: Device: PICCO; Device: NICCOMO

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Numbers of measurements of haemodynamic parameters (CO, CI, SV, SVV, CI, SVR, SVRI) obtained with impedance, that differ from those obtained with thermodilution

    measurements taken with impedance and thermodilution simultaneously, at PEEP 0, 5, 10, 15, 20 and at optimal PEEP

    Measured: up to 90 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Oct 2015 (estimated)
  2. Study startMay 2014
  3. Primary completionDec 2020 (estimated)
  4. Study completionMar 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Cross-sectional
Enrolment
50 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02572739
Sponsor's protocol ID
GUMed-Wu-002
Status last verified
Apr 2020
First submitted
23 Sep 2015
Last updated
13 Apr 2020
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Cardiovascular Diagnostic Techniques, run by Medical University of Gdansk at 1 site in Poland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 13 Apr 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Magdalena A Wujtewicz (+48583493357, magwuj@gumed.edu.pl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Numbers of measurements of haemodynamic parameters (CO, CI, SV, SVV, CI, SVR, SVRI) obtained with impedance, that differ from those obtained with thermodilution (time frame: up to 90 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Apr 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in