DiabetesCGMNCT02572856
Continuous Glucose Monitoring During and After Surgery
A study testing Continuous Glucose Monitor (CGM) in people with Diabetes, run by University of Washington at 1 site in United States.
Trial summary
During surgery and after surgery elevated blood glucose levels can lead to poor outcome such as wound infections. Current technology does not allow close monitoring of glucose levels often resulting in poor management of glucose levels. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Diabetes
- What is being tested?
- Continuous Glucose Monitor (CGM)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Aug 2018to 16 Nov 2021
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Adult (≥ 18 years) diabetic (both Type 1 \& 2) patients who are self-monitoring glucose levels (via finger stick measurements) two to three times daily.
- Scheduled to have elective general surgery at UW Medical Center. Preferably target Surgery A- Orthopedic/GYN surgery/Bariatric patients.
- Proposed case duration > 2 hour case.
Who cannot join
- Pregnant and lactating females
- MRI, CT \& Diathermy procedure
Trial locations and contacts
1 site in 1 country.
United States1 site
University of Washington Medical Center
Seattle, Washington, 98195
About this study
During surgery and after surgery elevated blood glucose levels can lead to poor outcome such as wound infections. Current technology does not allow close monitoring of glucose levels often resulting in poor management of glucose levels. In this study, the investigators will evaluate the feasibility of using a continuous glucose monitor (Dexcom Gen 6 Professional) during and after surgery. Such a monitor has the potential of monitoring glucose levels continuously and in real-time, thus allowing better glucose management
Read the detailed description
During surgery high blood glucose levels, termed hyperglycemia, are commonly encountered due to the physiological stress. Hyperglycemia has been associated with complications such as surgical site infections, adverse cardiovascular and pulmonary events. Optimal glucose control targeted at preventing hyperglycemia has been shown to reduce the risk of complications. However, performing optimal glycemic management during and after surgery is a significant challenge because varying effects of surgical stress and anesthesia interventions produce rapid changes in glucose levels. The current method of manually measuring blood glucose every hour or less is grossly inadequate to track changes in glucose levels. Continuous Glucose Monitors (CGMs) have the ability to automatically measure blood glucose levels in near continuous fashion. Integrating CGMs as part of a glycemic control protocol can lead to better management of glucose levels with fewer hyperglycemia episodes and lower glucose level variability resulting in better post-surgical outcome. The viability of using a CGM in during and after surgery has only been minimally studied, that too with older generation systems. The investigators propose a study that aims to evaluate viability of using a current generation CGM in surgery patients.
The primary goal of this study is to evaluate the feasibility and accuracy of a Continuous Glucose Monitor (CGM) in measuring blood glucose levels and trends in surgery patients. The secondary goal is to observe and analyze trends in perioperative blood glucose levels to understand the dynamic effects of surgical stress and anesthetic agents on blood glucose levels. This information will allow development of better intraoperative glucose management strategies and protocols. The specific aims of the study are outlined below:
- Compare glucose measurements made by a next generation, investigational Continuous Glucose Monitor (Dexcom Gen 6 Professional CGM) against point of care (POC) glucose meter (Accu Chek Inform II, Roche Diagnostics), during the intraoperative and postoperative periods.
- Correlate the trends in glucose levels measured by a CGM against surgery and anesthesia events (Induction, Incision, Emergence) and factors, and administration of anesthetic drugs (inhalational agents, steroids, etc)
The study protocol is described below:
CGM:
Dexcom Gen 6 Professional CGM will be used for the proposed study. The Gen 6 CGM is FDA approved for non-hospital use. Its use for the study will be off-label as it will be used in a hospital setting. However, for this study the CGM will be used as a secondary monitor not intended for patient care. The anesthesia provider and nurse practitioner will continue to use the existing manual glucose measurements (Point of care glucose meters or laboratory measurements) for clinical care. The measurements made by the Dexcom Gen 6 CGM will be blinded (not displayed) so that the providers and the patients cannot see or use the measured values.
The sensor will be placed on the upper arm. Sensor location will be consistent across all patients. Because CGM makes interstitial glucose measurement, any interference from IV infusions is anticipated to be minimal. However, to minimize any potential interaction with an infusion (Dextrose) the placement of the sensor will be on the arm different from the IV arm, if possible. After placement, the CGM sensor requires a warm-up period of 2 hours before which measurements cannot be made.
Study protocol:
The study will be conducted in a single phase at the University of Washington Medical Center. However, after the first 4 patients, a safety evaluation will be performed. Study will be continued only if the CGM is determined to be safe and able to make glucose measurements that are comparable to those made by the standard point of care (POC) glucose meter.
Screening and Consenting:
Potential patients will be identified through a surgery schedule report or at surgeon's clinic with assistance from PCC (Patient care coordinator) who will notify a research coordinator. The research coordinator will screen the patient to make sure that he/she meets the eligibility criteria. If a patient meets eligibility criteria, the research coordinator will approach the candidate patient either via mail or during the History \& Physical visit to communicate study details and provide the consent form. If an eligible patient expresses interest, research coordinator will arrange an appointment to place the CGM sensor about 2-4 hours prior to surgery.
The research coordinator will contact (by phone/email) the patient prior to surgery to answer any study related questions and to enquire about the patient's decision to participate in the study. If the candidate patient wishes to participate, the coordinator will make arrangements to obtain signed consent and enroll the patient in the study prior to surgery.
The research coordinator will meet with the eligible patient at the time of the sensor placement and collect the signed consent form, thus officially enrolling the patient for the study. The patient will be given a gift card ($50) as a token of appreciation for enrolling in the study.
Placement of the CGM sensor and calibration:
The CGM sensor has a warm-up period of 2 hours before which measurements cannot be made. CGM sensor will be applied on consented patients about 2.5 hours prior to surgery. The CGM monitor will be configured to not display the glucose measurements and trends (blinded mode). Lastly, the CGM clock will be synchronized to the hospital computer clock.
During surgery:
The institutional protocol for glucose management will be followed using the POC and lab glucose measurements as reference. The measurements made by the CGM will be blinded and the anesthesia provider will not be able to see or use the CGM values for clinical care. In the OR, the CGM monitor will placed on top platform of the anesthesia machine beside the POC glucose meter base. This location will ensure that the monitor is within 20 feet of the sensor and within the control of the anesthesia providers. Hourly blood glucose measurements performed by the POC glucose meter (Roche Diagnostics Inform II) or laboratory meter (part of arterial blood gas panel) will be automatically acquired and documented in the electronic anesthesia record. The CGM keeps a log of the continuous glucose measurements every 5 minutes for retrospective download and review. The anesthesia information system will also document the patient demographics (Age, Gender, BMI, etc), medications and fluid, anesthetic agent's concentrations, temperature, surgical and anesthesia events. These data elements can be retrospectively downloaded for analysis.
After surgery (PACU/ICU/Wards):
The institutional protocol for glucose management will be continued after surgery in PACU, surgical ICU or surgical wards. Glucose will continue to be monitored every 1-6 hours. In addition to POC measurements, blood samples taken for venous or arterial collection will be automatically documented in the inpatient electronic medical record. The CGM measurements will continue to be blinded to the nurse practitioner. CGM use will be continued for a total period of 72 hours after surgery or until the patient is discharged from the hospital whichever occurs earlier.
CGM monitor disconnect \& cleaning:
The CGM sensor and monitor will be removed at the end of the study period by either the research coordinator or the bedside nurse. The CGM will be covered in a protective shield and cleaned per procedures approved for the CGM. After cleaning procedures are complete the monitor will be used on a new patient. Additionally, the CGM measurements will be downloaded by the principal investigator into a data file for later analysis.
Safety and feasibility check:
A safety and feasibility check will be performed after the CGM has been applied on 4 patients. The primary outcome measure at the safety check point will be the ability of the sensor to make measurements and transmit the results to the monitor without data drops (without significant interruptions during electrocautery and other surgical interventions, anesthetic interventions and medication administration). Additionally, the feasibility of applying, maintaining and using the sensor in an OR environment will be evaluated for any potential issues. Lastly, the study will also observe any unexpected incidence of patient safety issues - potential infection, rash, or swelling of the area where the sensor is applied, potential RF interference etc.
The study will be continued only after successful completion of the safety check, and only if there is reasonable assurance that the CGM can be used safely and reliably in the operating room and postoperative areas with acceptable accuracy (Mean Absolute Relative Difference ~ 20%) without significant interference from anesthetic drugs, electrocautery, edema and other surgery and anesthesia factors.
Data extraction and analysis:
The CGM glucose measurements made every 5 minutes will be downloaded from the monitor to a computer file using a software program provided by Dexcom Inc. Patient demographics (Age, Gender, BMI, DM status), preoperative labs (glucose, HbA1c), anesthesia and surgery events, POC glucose measurements, medication data (including insulin), temperature and anesthetic agent information will be extracted from the Anesthesia Information Management System (AIMS) database. Post-operative glucose measurements and medication information will be collected from Hospital Electronic Medical Record and Data warehouse system (AMALGA, Microsoft Inc. Redmond, WA).
Data analysis will focus on three aspects:
- Test of equivalence: Paired CGM-POC measurements will be compared to determine mean bias (mean difference) and SD. The investigators will report the 95% limits of agreement, calculated as mean bias ± 1.96 X SD, the recommended statistic for assessing agreement between two methods of measurement. Data will be presented on Bland-Altman plots.
- CGM accuracy and bias: The CGM measurements will be compared against the corresponding POC glucose measurements to evaluate accuracy. MARD (Mean Absolute Relative Difference) will be used as the main accuracy measure. Effect of confounding factors - body temperature, BMI, Diabetes status, inotrope score, anesthetic agents, medications and use of electrocautery on CGM functionality and measurement accuracy will be evaluated. CGM accuracy assessment will be performed via the following steps:
- Pearson correlation coefficient between the CGM and POC glucose paired values
- Clarke Error Grid analysis relating CGM-POC glucose measurement pairs to evaluate clinical accuracy (% measurements in zones A \& B)
- MARD ranges for all paired CGM-POC glucose measurements for the following glucose ranges <100, 100-140, 140-180, > 180 mg/dL
- Trends and changes in blood glucose levels:
Trends and changes in blood glucose levels through the course of surgery and immediate postoperative phase (24 hours) will be analyzed across patients to determine consistent trend indicators (anesthesia and surgery events, use of medications, anesthetic agents etc). Specifically, multivariate analysis of glucose trends adjusted for covariates will be conducted to determine the effect of surgical stress, anesthesia and medications on blood glucose levels. CGM measurements will be used to evaluate the percentage of time glucose levels are within the desired range (100-140 mg/dL and 100-180 mg/dL) and evaluate the level of glucose excursions between hourly POC glucose measurements.
- Conditions
- Diabetes
- Being tested
- Continuous Glucose Monitor (CGM)
- Keywords
- Feasibility, continuous glucose monitor, surgery
- Medical subject headings
- Diabetes Mellitus
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Continuous Glucose Monitor (CGM)Device
Apply Dexcom Gen 6 Professional CGM sensor at least 2.5 hours prior to surgery Configure CGM so that its measurements are blinded. Setup CGM to make continuous glucose measurements during and after surgery. Download CGM measurement data after study and compare measurements against glucose measurements made for clinical care.
| Study group | Role | What they receive |
|---|---|---|
| CGM patients | Experimental | Apply continuous glucose monitor, calibrate and make glucose measurements. Measurements are blinded to the care provider Receives: Device: Continuous Glucose Monitor (CGM) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Safety and Feasibility Evaluation - Number of Unanticipated Safety Issues
After CGM has been applied on the first 4 patients, the study team will evaluate the safety and feasibility of using CGM. Specifically, the team will check whether there are unanticipated adverse events such as rashes or discomfort
Measured: After 4 patients (2 months)
Mean Absolute Relative Difference for CGM and POC Glucose Measurements
Compare glucose measurements made by a Dexcom G4 Professional Continuous Glucose Monitor (CGM) against point of care glucose meter (Accu-Check Inform II, Roche Diagnostics), during the intraoperative and postoperative phases. Measured as mean absolute relative difference (MARD) for CGM glucose values compared with the POC glucose measurements.
Measured: 10 months
Feasibility of Instrument: Count of CGM Instrument Issues
After 4 participants (2 months), the study team will assess the number of instrument breaks
Measured: After 4 participants (2 months)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Oct 2015 (estimated)
- Study start1 Aug 2018
- Primary completion31 May 2019
- Study completion16 Nov 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for DiabetesStudies of the same condition, open and under way.
- More trials run by University of WashingtonThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Washington
- Sponsor type
- University, hospital or other
- Collaborators
- DexCom, Inc.
- Responsible party
- Principal investigator, David Flum, University of Washington
- Investigators
- Irl B Hirsch, MD, Study chair, University of WashingtonDavid Flum, Principal investigator, University of Washington
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02572856
- Sponsor's protocol ID
- STUDY00003457
- Other IDs
- IIS-2014-028
- Acronym
- CGM
- Status last verified
- Aug 2023
- First submitted
- 5 Oct 2015
- Last updated
- 31 Aug 2023
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 31 Aug 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Continuous Glucose Monitoring During and After Surgery
- ClinicalTrials.gov ID
- NCT02572856
- Acronym / sponsor ID
- CGM / STUDY00003457
- Conditions
- Diabetes
- Keywords
- Feasibility, continuous glucose monitor, surgery
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- University of WashingtonUniversity, hospital or other
- Collaborators
- DexCom, Inc.
- Study start
- 1 Aug 2018 (actual)
- Primary completion
- 31 May 2019 (actual)
- Study completion
- 16 Nov 2021 (actual)
- First posted
- 9 Oct 2015 (estimated)
- Results
- Posted 31 Aug 2023
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
During surgery and after surgery elevated blood glucose levels can lead to poor outcome such as wound infections. Current technology does not allow close monitoring of glucose levels often resulting in poor management of glucose levels. In this study, the investigators will evaluate the feasibility of using a continuous glucose monitor (Dexcom Gen 6 Professional) during and after surgery. Such a monitor has the potential of monitoring glucose levels continuously and in real-time, thus allowing better glucose management
Detailed description
During surgery high blood glucose levels, termed hyperglycemia, are commonly encountered due to the physiological stress. Hyperglycemia has been associated with complications such as surgical site infections, adverse cardiovascular and pulmonary events. Optimal glucose control targeted at preventing hyperglycemia has been shown to reduce the risk of complications. However, performing optimal glycemic management during and after surgery is a significant challenge because varying effects of surgical stress and anesthesia interventions produce rapid changes in glucose levels. The current method of manually measuring blood glucose every hour or less is grossly inadequate to track changes in glucose levels. Continuous Glucose Monitors (CGMs) have the ability to automatically measure blood glucose levels in near continuous fashion. Integrating CGMs as part of a glycemic control protocol can lead to better management of glucose levels with fewer hyperglycemia episodes and lower glucose level variability resulting in better post-surgical outcome. The viability of using a CGM in during and after surgery has only been minimally studied, that too with older generation systems. The investigators propose a study that aims to evaluate viability of using a current generation CGM in surgery patients.
The primary goal of this study is to evaluate the feasibility and accuracy of a Continuous Glucose Monitor (CGM) in measuring blood glucose levels and trends in surgery patients. The secondary goal is to observe and analyze trends in perioperative blood glucose levels to understand the dynamic effects of surgical stress and anesthetic agents on blood glucose levels. This information will allow development of better intraoperative glucose management strategies and protocols. The specific aims of the study are outlined below:
- Compare glucose measurements made by a next generation, investigational Continuous Glucose Monitor (Dexcom Gen 6 Professional CGM) against point of care (POC) glucose meter (Accu Chek Inform II, Roche Diagnostics), during the intraoperative and postoperative periods.
- Correlate the trends in glucose levels measured by a CGM against surgery and anesthesia events (Induction, Incision, Emergence) and factors, and administration of anesthetic drugs (inhalational agents, steroids, etc)
The study protocol is described below:
CGM:
Dexcom Gen 6 Professional CGM will be used for the proposed study. The Gen 6 CGM is FDA approved for non-hospital use. Its use for the study will be off-label as it will be used in a hospital setting. However, for this study the CGM will be used as a secondary monitor not intended for patient care. The anesthesia provider and nurse practitioner will continue to use the existing manual glucose measurements (Point of care glucose meters or laboratory measurements) for clinical care. The measurements made by the Dexcom Gen 6 CGM will be blinded (not displayed) so that the providers and the patients cannot see or use the measured values.
The sensor will be placed on the upper arm. Sensor location will be consistent across all patients. Because CGM makes interstitial glucose measurement, any interference from IV infusions is anticipated to be minimal. However, to minimize any potential interaction with an infusion (Dextrose) the placement of the sensor will be on the arm different from the IV arm, if possible. After placement, the CGM sensor requires a warm-up period of 2 hours before which measurements cannot be made.
Study protocol:
The study will be conducted in a single phase at the University of Washington Medical Center. However, after the first 4 patients, a safety evaluation will be performed. Study will be continued only if the CGM is determined to be safe and able to make glucose measurements that are comparable to those made by the standard point of care (POC) glucose meter.
Screening and Consenting:
Potential patients will be identified through a surgery schedule report or at surgeon's clinic with assistance from PCC (Patient care coordinator) who will notify a research coordinator. The research coordinator will screen the patient to make sure that he/she meets the eligibility criteria. If a patient meets eligibility criteria, the research coordinator will approach the candidate patient either via mail or during the History \& Physical visit to communicate study details and provide the consent form. If an eligible patient expresses interest, research coordinator will arrange an appointment to place the CGM sensor about 2-4 hours prior to surgery.
The research coordinator will contact (by phone/email) the patient prior to surgery to answer any study related questions and to enquire about the patient's decision to participate in the study. If the candidate patient wishes to participate, the coordinator will make arrangements to obtain signed consent and enroll the patient in the study prior to surgery.
The research coordinator will meet with the eligible patient at the time of the sensor placement and collect the signed consent form, thus officially enrolling the patient for the study. The patient will be given a gift card ($50) as a token of appreciation for enrolling in the study.
Placement of the CGM sensor and calibration:
The CGM sensor has a warm-up period of 2 hours before which measurements cannot be made. CGM sensor will be applied on consented patients about 2.5 hours prior to surgery. The CGM monitor will be configured to not display the glucose measurements and trends (blinded mode). Lastly, the CGM clock will be synchronized to the hospital computer clock.
During surgery:
The institutional protocol for glucose management will be followed using the POC and lab glucose measurements as reference. The measurements made by the CGM will be blinded and the anesthesia provider will not be able to see or use the CGM values for clinical care. In the OR, the CGM monitor will placed on top platform of the anesthesia machine beside the POC glucose meter base. This location will ensure that the monitor is within 20 feet of the sensor and within the control of the anesthesia providers. Hourly blood glucose measurements performed by the POC glucose meter (Roche Diagnostics Inform II) or laboratory meter (part of arterial blood gas panel) will be automatically acquired and documented in the electronic anesthesia record. The CGM keeps a log of the continuous glucose measurements every 5 minutes for retrospective download and review. The anesthesia information system will also document the patient demographics (Age, Gender, BMI, etc), medications and fluid, anesthetic agent's concentrations, temperature, surgical and anesthesia events. These data elements can be retrospectively downloaded for analysis.
After surgery (PACU/ICU/Wards):
The institutional protocol for glucose management will be continued after surgery in PACU, surgical ICU or surgical wards. Glucose will continue to be monitored every 1-6 hours. In addition to POC measurements, blood samples taken for venous or arterial collection will be automatically documented in the inpatient electronic medical record. The CGM measurements will continue to be blinded to the nurse practitioner. CGM use will be continued for a total period of 72 hours after surgery or until the patient is discharged from the hospital whichever occurs earlier.
CGM monitor disconnect \& cleaning:
The CGM sensor and monitor will be removed at the end of the study period by either the research coordinator or the bedside nurse. The CGM will be covered in a protective shield and cleaned per procedures approved for the CGM. After cleaning procedures are complete the monitor will be used on a new patient. Additionally, the CGM measurements will be downloaded by the principal investigator into a data file for later analysis.
Safety and feasibility check:
A safety and feasibility check will be performed after the CGM has been applied on 4 patients. The primary outcome measure at the safety check point will be the ability of the sensor to make measurements and transmit the results to the monitor without data drops (without significant interruptions during electrocautery and other surgical interventions, anesthetic interventions and medication administration). Additionally, the feasibility of applying, maintaining and using the sensor in an OR environment will be evaluated for any potential issues. Lastly, the study will also observe any unexpected incidence of patient safety issues - potential infection, rash, or swelling of the area where the sensor is applied, potential RF interference etc.
The study will be continued only after successful completion of the safety check, and only if there is reasonable assurance that the CGM can be used safely and reliably in the operating room and postoperative areas with acceptable accuracy (Mean Absolute Relative Difference ~ 20%) without significant interference from anesthetic drugs, electrocautery, edema and other surgery and anesthesia factors.
Data extraction and analysis:
The CGM glucose measurements made every 5 minutes will be downloaded from the monitor to a computer file using a software program provided by Dexcom Inc. Patient demographics (Age, Gender, BMI, DM status), preoperative labs (glucose, HbA1c), anesthesia and surgery events, POC glucose measurements, medication data (including insulin), temperature and anesthetic agent information will be extracted from the Anesthesia Information Management System (AIMS) database. Post-operative glucose measurements and medication information will be collected from Hospital Electronic Medical Record and Data warehouse system (AMALGA, Microsoft Inc. Redmond, WA).
Data analysis will focus on three aspects:
- Test of equivalence: Paired CGM-POC measurements will be compared to determine mean bias (mean difference) and SD. The investigators will report the 95% limits of agreement, calculated as mean bias ± 1.96 X SD, the recommended statistic for assessing agreement between two methods of measurement. Data will be presented on Bland-Altman plots.
- CGM accuracy and bias: The CGM measurements will be compared against the corresponding POC glucose measurements to evaluate accuracy. MARD (Mean Absolute Relative Difference) will be used as the main accuracy measure. Effect of confounding factors - body temperature, BMI, Diabetes status, inotrope score, anesthetic agents, medications and use of electrocautery on CGM functionality and measurement accuracy will be evaluated. CGM accuracy assessment will be performed via the following steps:
- Pearson correlation coefficient between the CGM and POC glucose paired values
- Clarke Error Grid analysis relating CGM-POC glucose measurement pairs to evaluate clinical accuracy (% measurements in zones A \& B)
- MARD ranges for all paired CGM-POC glucose measurements for the following glucose ranges <100, 100-140, 140-180, > 180 mg/dL
- Trends and changes in blood glucose levels:
Trends and changes in blood glucose levels through the course of surgery and immediate postoperative phase (24 hours) will be analyzed across patients to determine consistent trend indicators (anesthesia and surgery events, use of medications, anesthetic agents etc). Specifically, multivariate analysis of glucose trends adjusted for covariates will be conducted to determine the effect of surgical stress, anesthesia and medications on blood glucose levels. CGM measurements will be used to evaluate the percentage of time glucose levels are within the desired range (100-140 mg/dL and 100-180 mg/dL) and evaluate the level of glucose excursions between hourly POC glucose measurements.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| CGM patients | Experimental | Device: Continuous Glucose Monitor (CGM)Apply continuous glucose monitor, calibrate and make glucose measurements. Measurements are blinded to the care provider |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adult (≥ 18 years) diabetic (both Type 1 \& 2) patients who are self-monitoring glucose levels (via finger stick measurements) two to three times daily.
- Scheduled to have elective general surgery at UW Medical Center. Preferably target Surgery A- Orthopedic/GYN surgery/Bariatric patients.
- Proposed case duration > 2 hour case.
Key exclusion criteria (2 listed)
- Pregnant and lactating females
- MRI, CT \& Diathermy procedure
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Continuous Glucose Monitor (CGM)Apply Dexcom Gen 6 Professional CGM sensor at least 2.5 hours prior to surgery Configure CGM so that its measurements are blinded. Setup CGM to make continuous glucose measurements during and after surgery. Download CGM measurement data after study and compare measurements against glucose measurements made for clinical care. | Device | CGM patients |
Primary outcome
Safety and Feasibility Evaluation - Number of Unanticipated Safety Issues
Time frame: After 4 patients (2 months)
After CGM has been applied on the first 4 patients, the study team will evaluate the safety and feasibility of using CGM. Specifically, the team will check whether there are unanticipated adverse events such as rashes or discomfort
Mean Absolute Relative Difference for CGM and POC Glucose Measurements
Time frame: 10 months
Compare glucose measurements made by a Dexcom G4 Professional Continuous Glucose Monitor (CGM) against point of care glucose meter (Accu-Check Inform II, Roche Diagnostics), during the intraoperative and postoperative phases. Measured as mean absolute relative difference (MARD) for CGM glucose values compared with the POC glucose measurements.
Feasibility of Instrument: Count of CGM Instrument Issues
Time frame: After 4 participants (2 months)
After 4 participants (2 months), the study team will assess the number of instrument breaks
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 31 Aug 2023.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Diabetes
Not yet recruitingPhase 3
Efficacy and Safety of Once-Weekly SHR-3167 Compared With Once-Daily Insulin Glargine in Adults With Insulin-Naive Type 2 Diabetes
Type 2 Diabetes
Active, not recruiting
Digital Reinforcement of Motivational Interviewing Micro-Skills Among Primary Care Healthcare Professionals
Hypertension (Without Type 2 Diabetes Mellitus)
Recruiting
Effects of Lean Pork Loin Intake on Protein Homeostasis and Glucose Regulation in Prediabetic Adults
Hyperglycaemia (Non Diabetic), Prediabetes
Recruiting
PAW-Hydrogel for Chronic Wound Healing
Diabetic Foot Ulcer (DFU), Pressure Ulcer (PU)
Recruiting
Investigating Vascular Properties of HEMI and SPG Signals in Individuals With or at Risk for Chronic Kidney Disease
Chronic Kidney Disease, Hypertension (HTN)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Irl B Hirsch, MD study chair
University of Washington
David Flum principal investigator
University of Washington
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Continuous Glucose Monitor (CGM) in people with Diabetes, run by University of Washington at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 31 Aug 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 31 Aug 2023). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Safety and Feasibility Evaluation - Number of Unanticipated Safety Issues (time frame: After 4 patients (2 months)). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.