Coronary Artery DiseaseACIST-FFRNCT02577484
Assessment of Catheter-based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement
An observational study of Coronary Artery Disease, run by Acist Medical Systems at 12 sites in United States.
Trial summary
This study will assess the differences between Fractional Flow Reserve (FFR) measurements made by the Navvus catheter and a commercially available pressure guidewire in up to 240 subjects where FFR is clinically indicated. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- RXi System and Pressure Wire
- Type of treatment
- Medical device
- How many people
- 240 participants
- Where
- 12 sitesUnited States
- Study dates
- Nov 2015to Jan 2017
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Subjects 18 years of age or older, with single or multi-vessel CAD for whom FFR measurement is indicated to guide percutaneous coronary intervention strategy.
General Inclusion Criteria:
- Subject is 18 years of age or older
- Subject has a clinical indication for coronary angiography
- Subject or subject's legal representative has the ability to understand and provide signed consent for participating in the study
Angiographic Inclusion Criteria:
- Vessel has a TIMI flow = 3
- Subject has de novo lesion which physician has determined has a clinical indication for FFR measurement
- RVD of the target lesion is assessed by the operator to be ≥2.25 mm.
General Exclusion Criteria:
- Subjects with acute ST-elevation or non-ST-elevation myocardial infarction as the indication for coronary angiography
- NYHA Class 4 severe heart failure
Angiographic Exclusion Criteria:
- Target vessel has angiographically visible or suspected thrombus.
- Target lesion is within a bypass graft.
- Angiographic evidence of a dissection prior to initiation of PW measurements.
- Target vessel contains excessive tortuosity or calcification.
Trial locations and contacts
12 sites in 1 country.
12 sites in 1 country
United States12 sites
University of Chicago Medicine
Chicago, Illinois, 60637
Lindner Research Center at The Christ Hospital
Cincinnati, Ohio, 45219
Cleveland Cllinic Foundation
Cleveland, Ohio, 44195
Scripps Green Hospital
La Jolla, California, 92037
Long Beach VA Medical Center
Long Beach, California, 90822
Metropolitan Cardiology Heart and Vascular Institute
Minneapolis, Minnesota, 55433
University of Minnesota
Minneapolis, Minnesota, 55455
Columbia University Medical Center / New York Presbyterian Hospital
New York, New York, 10032
Saint Louis University
St Louis, Missouri, 63110
Stanford School of Medicine
Stanford, California, 94305
Medstart Washington Hospital Center
Washington D.C., District of Columbia, 20010
Iowa Heart Center
West Des Moines, Iowa, 50266
About this study
Official title: Assessment of Catheter-based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement: the ACIST-FFR Study
This study will assess the differences between Fractional Flow Reserve (FFR) measurements made by the Navvus catheter and a commercially available pressure guidewire in up to 240 subjects where FFR is clinically indicated. All subjects will receive diagnostic treatment according to clinical indications and center standard practice.
Read the detailed description
The ACIST-FFR study is a prospective, open label, observational, multi-center study designed to assess the differences, if any, between FFR measured by the Navvus catheter and a commercially available 0.014-inch pressure guidewire (St. Jude Medical, Volcano, hereafter referred to as the PW) in subjects with coronary artery disease (CAD) undergoing coronary angiography. This will be accomplished by comparing the FFR measurement obtained with the ACIST Medical Systems RXi System and Navvus catheter with the FFR measurement obtained by using a PW within the same subject across the same target lesion at the same time.
- Conditions
- Coronary Artery Disease
- Being tested
- RXi System, Pressure Wire
- Keywords
- Fractional Flow Reserve, Rapid Exchange, Catheter
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
RXi SystemDevice
Also called ACIST Medical Systems RXi System, Navvus Catheter
Provide hemodynamic information for the diagnosis and treatment of coronary and peripheral artery disease. The system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display fractional flow reserve or FFR.
Measurement of FFR requires simultaneously monitoring the blood pressures proximal and distal to a lesion. The RXi system includes a single use catheter (Navvus) with a pressure sensor for acquisition of the distal pressure. The proximal pressure is acquired by the guide catheter via an interface to the hospital hemodynamic monitor.
The Navvus catheter interfaces to the RXi system console which includes embedded software, a user interface touch screen and associated electronics.
Pressure WireDevice
Also called St. Jude PressueWire Aeris Guidewire, St. Jude PressureWire Certus Guidewire, Volcano PrimeWire Prestige
Provide hemodynamic information for the diagnosis and treatment of coronary and peripheral artery disease. The system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display fractional flow reserve or FFR.
| Study group | Role | What they receive |
|---|---|---|
| Participants | Subjects who satisfy both general and angiographic inclusion/exclusion criteria, and who have the pressure measurement taken with the Navvus catheter. Receives: Device: RXi System; Device: Pressure Wire |
What is being measured
The primary outcome is the main question the study is designed to answer.
FFR Measurements
Bias between Navvus and PW FFR measurements, as assessed by Bland-Altman analysis
Measured: Duration of FFR Procedure
Secondary outcomes (14)
Slope of Passing-Bablok
Slope of Passing-Bablok fit between paired FFR measurements by Navvus and PW
Measured: Duration of FFR Procedure
Intercept of Passing-Bablok
Intercept of Passing-Bablok fit between paired FFR measurements by Navvus and PW
Measured: Duration of FFR Procedure
Comparability of FFR Measurements
Comparability of PW FFR and Navvus FFR measurements at PW FFR=0.80, by Passing-Bablok analysis.
Measured: Duration of FFR Procedure
Diagnostic FFR concurrence of stenosis significance
Concurrence of Navvus FFR diagnostic accuracy of stenosis significance, using PW FFR ≤0.80 as the standard.
Measured: Duration of FFR Procedure
Device success rate
Device success rate, defined as a valid FFR reading, for each system individually, and comparison between the two systems.
Measured: Duration of FFR Procedure
Mean drift
Mean drift, defined as the absolute difference between Pd/Pa at the equalization position after pullback and 1.00, for each system individually, and comparison between the two systems.
Measured: Duration of FFR Procedure
Rate of clinically significant drift
Rate of clinically significant drift, defined as drift >0.03, for each system individually, and comparison between the two systems.
Measured: Duration of FFR Procedure
Rate of device-related adverse effects
Rate of device-related adverse effects, for each system individually, and comparison between the two systems.
Measured: Duration of FFR Procedure
PW FFR measurements with Navvus across and not across lesion
Comparisons between PW FFR measurements with Navvus across lesion and with Navvus not across lesion, including bias as assessed by Bland-Altman analysis.
Measured: Duration of FFR Procedure
Comparison of FFR Measurements including bias
Comparisons between PW (with Navvus present in lesion) and Navvus FFR measurements, including bias assessed by Bland-Altman analysis.
Measured: Duration of FFR Procedure
Correlation between Navvus diagnostic accuracy, bias, and angiographic characteristics
Relationship between Navvus diagnostic accuracy, bias, and angiographic characteristics such as lesion length and reference vessel diameter.
Measured: Duration of FFR Procedure
PW Pd/Pa diagnostic concurrence of stenosis signficance
PW Pd/Pa diagnostic accuracy (concurrence) of stenosis significance, using PW FFR ≤0.80 as the standard.
Measured: Duration of FFR Procedure
PW Pd/Pa measurements with Navvus across and not across lesion
Comparisons between PW Pd/Pa measurements with Navvus across lesion and with Navvus not across lesion, including bias as assessed by Bland-Altman analysis.
Measured: Duration of FFR Procedure
Comparison of Pd/Pa Measurements including bias
Comparisons between PW (with Navvus present in lesion) and Navvus Pd/Pa measurements, including bias assessed by Bland-Altman analysis.
Measured: Duration of FFR Procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted16 Oct 2015 (estimated)
- Study startNov 2015
- Primary completionJan 2017 (estimated)
- Study completionJan 2017 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 240 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Acist Medical Systems
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- William Fearon, MD, Principal investigator, Stanford Cardiovascular Medical ClinicMatthew Price, MD, Principal investigator, Scripps Green Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02577484
- Sponsor's protocol ID
- US100
- Acronym
- ACIST-FFR
- Status last verified
- Oct 2016
- First submitted
- 13 Oct 2015
- Last updated
- 6 Dec 2016
- Results posted
- No
- Data monitoring committee
- No
Publications
Fearon WF, Bornschein B, Tonino PA, Gothe RM, Bruyne BD, Pijls NH, Siebert U; Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) Study Investigators. Economic evaluation of fractional flow reserve-guided percutaneous coronary intervention in patients with multivessel disease. Circulation. 2010 Dec 14;122(24):2545-50. doi: 10.1161/CIRCULATIONAHA.109.925396. Epub 2010 Nov 29.
PubMed 21126973Fearon WF, Tonino PA, De Bruyne B, Siebert U, Pijls NH; FAME Study Investigators. Rationale and design of the Fractional Flow Reserve versus Angiography for Multivessel Evaluation (FAME) study. Am Heart J. 2007 Oct;154(4):632-6. doi: 10.1016/j.ahj.2007.06.012.
PubMed 17892983King SB 3rd, Smith SC Jr, Hirshfeld JW Jr, Jacobs AK, Morrison DA, Williams DO, Feldman TE, Kern MJ, O'Neill WW, Schaff HV, Whitlow PL; ACC/AHA/SCAI; Adams CD, Anderson JL, Buller CE, Creager MA, Ettinger SM, Halperin JL, Hunt SA, Krumholz HM, Kushner FG, Lytle BW, Nishimura R, Page RL, Riegel B, Tarkington LG, Yancy CW. 2007 focused update of the ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: a report of the American College of Cardiology/American Heart Association Task Force on Practice guidelines. J Am Coll Cardiol. 2008 Jan 15;51(2):172-209. doi: 10.1016/j.jacc.2007.10.002. No abstract available.
PubMed 18191745Pijls NH, Fearon WF, Tonino PA, Siebert U, Ikeno F, Bornschein B, van't Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, De Bruyne B; FAME Study Investigators. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) study. J Am Coll Cardiol. 2010 Jul 13;56(3):177-84. doi: 10.1016/j.jacc.2010.04.012. Epub 2010 May 28.
PubMed 20537493Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van' t Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, Fearon WF; FAME Study Investigators. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med. 2009 Jan 15;360(3):213-24. doi: 10.1056/NEJMoa0807611.
PubMed 19144937Fearon WF, Chambers JW, Seto AH, Sarembock IJ, Raveendran G, Sakarovitch C, Yang L, Desai M, Jeremias A, Price MJ; ACIST-FFR Study Investigators. ACIST-FFR Study (Assessment of Catheter-Based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement). Circ Cardiovasc Interv. 2017 Dec;10(12):e005905. doi: 10.1161/CIRCINTERVENTIONS.117.005905.
PubMed 29246917
Study at a glance
From the registry record, last updated by the sponsor on 6 Dec 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Assessment of Catheter-based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement: the ACIST-FFR Study
- ClinicalTrials.gov ID
- NCT02577484
- Acronym / sponsor ID
- ACIST-FFR / US100
- Conditions
- Coronary Artery Disease
- Keywords
- Fractional Flow Reserve, Rapid Exchange, Catheter
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 240 participants (estimated)
- Lead sponsor
- Acist Medical SystemsIndustry (pharma, biotech, devices)
- Study start
- Nov 2015
- Primary completion
- Jan 2017 (estimated)
- Study completion
- Jan 2017 (estimated)
- First posted
- 16 Oct 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study will assess the differences between Fractional Flow Reserve (FFR) measurements made by the Navvus catheter and a commercially available pressure guidewire in up to 240 subjects where FFR is clinically indicated. All subjects will receive diagnostic treatment according to clinical indications and center standard practice.
Detailed description
The ACIST-FFR study is a prospective, open label, observational, multi-center study designed to assess the differences, if any, between FFR measured by the Navvus catheter and a commercially available 0.014-inch pressure guidewire (St. Jude Medical, Volcano, hereafter referred to as the PW) in subjects with coronary artery disease (CAD) undergoing coronary angiography. This will be accomplished by comparing the FFR measurement obtained with the ACIST Medical Systems RXi System and Navvus catheter with the FFR measurement obtained by using a PW within the same subject across the same target lesion at the same time.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Participants | – | Device: RXi System, Device: Pressure WireSubjects who satisfy both general and angiographic inclusion/exclusion criteria, and who have the pressure measurement taken with the Navvus catheter. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Subjects 18 years of age or older, with single or multi-vessel CAD for whom FFR measurement is indicated to guide percutaneous coronary intervention strategy.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| RXi SystemAlso: ACIST Medical Systems RXi System, Navvus CatheterProvide hemodynamic information for the diagnosis and treatment of coronary and peripheral artery disease. The system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display fractional flow reserve or FFR. Measurement of FFR requires simultaneously monitoring the blood pressures proximal and distal to a lesion. The RXi system includes a single use catheter (Navvus) with a pressure sensor for acquisition of the distal pressure. The proximal pressure is acquired by the guide catheter via an interface to the hospital hemodynamic monitor. The Navvus catheter interfaces to the RXi system console which includes embedded software, a user interface touch screen and associated electronics. | Device | Participants |
| Pressure WireAlso: St. Jude PressueWire Aeris Guidewire, St. Jude PressureWire Certus Guidewire, Volcano PrimeWire PrestigeProvide hemodynamic information for the diagnosis and treatment of coronary and peripheral artery disease. The system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display fractional flow reserve or FFR. | Device | Participants |
Primary outcome
FFR Measurements
Time frame: Duration of FFR Procedure
Bias between Navvus and PW FFR measurements, as assessed by Bland-Altman analysis
14 secondary outcomes
Slope of Passing-Bablok
Time frame: Duration of FFR Procedure
Intercept of Passing-Bablok
Time frame: Duration of FFR Procedure
Comparability of FFR Measurements
Time frame: Duration of FFR Procedure
Diagnostic FFR concurrence of stenosis significance
Time frame: Duration of FFR Procedure
Device success rate
Time frame: Duration of FFR Procedure
Mean drift
Time frame: Duration of FFR Procedure
Rate of clinically significant drift
Time frame: Duration of FFR Procedure
Rate of device-related adverse effects
Time frame: Duration of FFR Procedure
PW FFR measurements with Navvus across and not across lesion
Time frame: Duration of FFR Procedure
Comparison of FFR Measurements including bias
Time frame: Duration of FFR Procedure
Correlation between Navvus diagnostic accuracy, bias, and angiographic characteristics
Time frame: Duration of FFR Procedure
PW Pd/Pa diagnostic concurrence of stenosis signficance
Time frame: Duration of FFR Procedure
PW Pd/Pa measurements with Navvus across and not across lesion
Time frame: Duration of FFR Procedure
Comparison of Pd/Pa Measurements including bias
Time frame: Duration of FFR Procedure
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Dec 2016.
- Background: PubMed 21126973Fearon WF, Bornschein B, Tonino PA, Gothe RM, Bruyne BD, Pijls NH, Siebert U; Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) Study Investigators. Economic evaluation of fractional flow reserve-guided percutaneous coronary intervention in patients with multivessel disease. Circulation. 2010 Dec 14;122(24):2545-50. doi: 10.1161/CIRCULATIONAHA.109.925396. Epub 2010 Nov 29.
- Background: PubMed 17892983Fearon WF, Tonino PA, De Bruyne B, Siebert U, Pijls NH; FAME Study Investigators. Rationale and design of the Fractional Flow Reserve versus Angiography for Multivessel Evaluation (FAME) study. Am Heart J. 2007 Oct;154(4):632-6. doi: 10.1016/j.ahj.2007.06.012.
- Background: PubMed 18191745King SB 3rd, Smith SC Jr, Hirshfeld JW Jr, Jacobs AK, Morrison DA, Williams DO, Feldman TE, Kern MJ, O'Neill WW, Schaff HV, Whitlow PL; ACC/AHA/SCAI; Adams CD, Anderson JL, Buller CE, Creager MA, Ettinger SM, Halperin JL, Hunt SA, Krumholz HM, Kushner FG, Lytle BW, Nishimura R, Page RL, Riegel B, Tarkington LG, Yancy CW. 2007 focused update of the ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: a report of the American College of Cardiology/American Heart Association Task Force on Practice guidelines. J Am Coll Cardiol. 2008 Jan 15;51(2):172-209. doi: 10.1016/j.jacc.2007.10.002. No abstract available.
- Background: PubMed 20537493Pijls NH, Fearon WF, Tonino PA, Siebert U, Ikeno F, Bornschein B, van't Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, De Bruyne B; FAME Study Investigators. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) study. J Am Coll Cardiol. 2010 Jul 13;56(3):177-84. doi: 10.1016/j.jacc.2010.04.012. Epub 2010 May 28.
- Background: PubMed 19144937Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van' t Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, Fearon WF; FAME Study Investigators. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med. 2009 Jan 15;360(3):213-24. doi: 10.1056/NEJMoa0807611.
- Derived from this study: PubMed 29246917Fearon WF, Chambers JW, Seto AH, Sarembock IJ, Raveendran G, Sakarovitch C, Yang L, Desai M, Jeremias A, Price MJ; ACIST-FFR Study Investigators. ACIST-FFR Study (Assessment of Catheter-Based Interrogation and Standard Techniques for Fractional Flow Reserve Measurement). Circ Cardiovasc Interv. 2017 Dec;10(12):e005905. doi: 10.1161/CIRCINTERVENTIONS.117.005905.
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
William Fearon, MD principal investigator
Stanford Cardiovascular Medical Clinic
Matthew Price, MD principal investigator
Scripps Green Hospital
12 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Coronary Artery Disease, run by Acist Medical Systems at 12 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 6 Dec 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 12 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
FFR Measurements (time frame: Duration of FFR Procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02577484, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Dec 2016.