Osteoarthritis of KneeNCT02579174

Total Knee Replacement Component Alignment Using Manual Versus Custom Instrumentation

A study testing Medacta GMK Sphere in people with Osteoarthritis of Knee, run by Northwestern University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

1. To determine whether the low-dose, biplanar x-ray imaging (EOS) has the same accuracy as computed axial tomography (CT) 2. To validate low-dose, biplanar x-ray imaging (EOS) as a tool to evaluate 3-dimensional alignment of Total Knee Replacement implants. 3. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Osteoarthritis of Knee
What is being tested?
Medacta GMK Sphere
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
112 participants
Where
1 siteUnited States
Study dates
Jan 2015to 30 Nov 2020
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Radiographically confirmed diagnosis of osteoarthritis (OA)
  • Failure of non-operative treatment for the diagnosis of symptomatic osteoarthritis
  • Age greater than 18 years
  • Desire to proceed with elective TKR
  • Completion of informed consent and signature of written consent form

Who cannot join

  • Ligamentous instability that may necessitate a constrained TKR implant
  • Retained hardware in the distal femur or proximal tibia of the operative extremity
  • Medical contraindication to undergo preoperative CT, or inability to tolerate preoperative CT

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Northwestern Medicine Department of Orthopaedic Surgery

    Chicago, Illinois, 60611

Other trials in United States

About this study

  1. To determine whether the low-dose, biplanar x-ray imaging (EOS) has the same accuracy as computed axial tomography (CT)
  2. To validate low-dose, biplanar x-ray imaging (EOS) as a tool to evaluate 3-dimensional alignment of Total Knee Replacement implants.
  3. To evaluate differences in total knee replacement implant alignment in patients whose arthroplasty is performed using manual or custom instrumentation derived from preoperative CT
Read the detailed description

Achieving optimal prosthetic alignment of the femoral, tibial and patellar components during Total Knee Replacement (TKR) is of great importance as it contributes to better function, less pain and improved quality of life.TKR requires accuracy in the execution of bone cuts in the correct orientation to the coronal, sagittal and axial planes. Malposition potentially leads to increased mechanical stress on the bearing surfaces and inevitably to earlier loosening.

Computed Axial Tomography (CT) is the gold standard technique to evaluate implant alignment in the coronal, sagittal and axial planes. As such, CT has imaging has been used to create custom instrumentation with purported likely improvement in surgical outcomes. Customized instrumentation created from a preoperative CT has been shown to be safe and effective, with no reported difference in patient outcomes and similar total knee arthroplasty component alignment. However, taking into consideration CT's high levels of radiation, cost expenses and its inability to obtain images of the limb in weight-bearing position, CT scan cannot be used routinely as a postoperative tool to evaluate TKR implant positioning.

The imaging system manufactured by EOS Imaging (formerly Biospace Med, Paris) is a biplanar, low-dose radiation, full body, high resolution, radiological imaging system allowing simultaneous acquisition in the coronal and sagittal planes and in standing position.EOS' main benefits are the considerable reduction in radiation dose (up to 1000 times less than for CT and ten times less than the plain radiography) by using a gaseous detector. George Charpak, the inventor, was awarded the Nobel Prize in 1992 for this work. Moreover, the EOS system can provide 3D images by using the appropriate software algorithms, thus providing a low-radiation alternative to CT.

Being tested
Medacta GMK Sphere
Medical subject headings
Osteoarthritis, Knee

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Medacta GMK SphereDevice

Study groups in NCT02579174
Study groupRoleWhat they receive
Manual (tibia) and manual (femur)OtherKnee replacement with Medacta GMK Sphere implants using manual instrumentation for both the tibia component and the femur component
Receives: Device: Medacta GMK Sphere
Manual (tibia) and custom (femur)OtherKnee replacement with Medacta GMK Sphere implants using manual instrumentation for the tibia component and custom instrumentation for the femur component
Receives: Device: Medacta GMK Sphere
Custom (tibia) and custom (femur)OtherKnee replacement with Medacta GMK Sphere implants using custom instrumentation for both the tibia component and the femur component
Receives: Device: Medacta GMK Sphere
Custom (tibia) and manual (femur)OtherKnee replacement with Medacta GMK Sphere implants using custom instrumentation for the tibia component and manual instrumentation for the femur component
Receives: Device: Medacta GMK Sphere

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Post-Operative Hip-Knee-Angle (HKA)

    Measured HKA change from pre-operative EOS longstanding X-ray to post-operative EOS at 6wks. comparing groups receiving manual instrumentation versus custom instrumentation

    Measured: Pre-operative, 6 wks. post-op

Secondary outcomes (3)
  1. Tibial Varus Deformity

    Measured change between pre-operative planning report \& post-operative EOS longstanding radiograph in varus deformity of the operative joint

    Measured: Pre-operative, 6 wks. post-op

  2. Femoral Valgus Deformity

    Measured change between pre-operative planning report \& post-operative EOS longstanding radiograph in varus deformity of the operative joint

    Measured: Pre-operative, 6 wks. post-op

  3. Tibial Posterior Slope (Mean Deviation)

    Deviation from pre-operative planning template \& 6 wk. post-operative longstanding EOS radiograph

    Measured: Pre-Operative - 6 wk. Post-Operative

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Oct 2015 (estimated)
  2. Study startJan 2015
  3. Primary completion8 Sep 2020
  4. Study completion30 Nov 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Factorial
Masking
Single blind
Who is masked
Participant
Enrolment
112 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02579174
Sponsor's protocol ID
STU00200223
Status last verified
Oct 2022
First submitted
13 Oct 2015
Last updated
15 Nov 2022
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Medacta GMK Sphere in people with Osteoarthritis of Knee, run by Northwestern University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Nov 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 15 Nov 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Post-Operative Hip-Knee-Angle (HKA) (time frame: Pre-operative, 6 wks. post-op). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Nov 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in