Tremor, LimbPRDBRS2NCT02585583
Deep Brain Frameless Radiosurgery for Drug Resistant Invalidating Tremor. Dose Escalation Pilot Study
A study testing Thalamotomy in people with Tremor, Limb, run by Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta at 1 site in Italy.
Trial summary
The gamma knife radiosurgical thalamotomy to treat many movement disorders is recently becoming a new and well defined treatment paradigm. The CyberKnife if compared to the frame-based radiosurgery, is a pain free procedure which offers the advantage of a better patient's compliance by avoiding local anaesthesia and… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Tremor, Limb
- What is being tested?
- Thalamotomy
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 8 participants
- Where
- 1 siteItaly
- Study dates
- May 2015to 31 Dec 2021
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients affected by severe upper limb tremor refractory to medical therapy and who are less than optimal candidate for a deep brain stimulation (DBS) procedure.
- Age ≥ 18 years old
- Refusal of DBS procedure
- Written consent
Who cannot join
- Pregnancy
- CT/MRI contraindication
- Illiteracy
Trial locations and contacts
1 site in 1 country.
About this study
The gamma knife radiosurgical thalamotomy to treat many movement disorders is recently becoming a new and well defined treatment paradigm.
The CyberKnife if compared to the frame-based radiosurgery, is a pain free procedure which offers the advantage of a better patient's compliance by avoiding local anaesthesia and the discomfort due to wearing the frame for the period of time needed for the whole procedure.
Read more
Unfortunately the subtle but substantial differences about the 3D dose distribution and the dose fall-off features between GK and CK made mandatory investigations about the effectiveness and the safety when the cyberknife is used.
Particularly the minimum effective and safety dose have to be defined yet A previous study (NCT02095600) failed in demonstrating the efficacy of 75 Gy, 80 Gy, 90 Gy.
The aim of the present study is to investigate about the effectiveness of 100 Gy, 120 Gy, 130 Gy and 140 Gy.
The safety and the targeting methodology will be also in investigated.
Read the detailed description
BACKGROUND The stereotactic lesioning of thalamus and basal ganglia for the treatment of tremor is a well-known procedure which, before the introduction of deep brain stimulation ( DBS), was usually performed using stereotactic surgical procedures.[16] Consistent positive experience in functional radiosurgery using the Gamma Knife or linear accelerators was reported since the first report by Leksell in 1951.[4, 8, 11, 13, 14, 17, 18, 19, 21, 24, 25, 26, 27] CyberKnife (CK), (Accuray Inc., Sunnyvale, California, USA) allows a real frameless stereotactic radiosurgery of recognizable intracranial targets such as arteriovenous malformations (AVMs), tumours, and trigeminal nerve for the treatment of trigeminal neuralgia.[1, 2, 3, 7, 9, 23] When compared to the frame-based radiosurgery , frameless radiosurgery is a pain free procedure which offers the advantage of a better patient's compliance by avoiding local anaesthesia and the discomfort due to wearing the frame for the period of time needed for the whole procedure.
The present literature on functional frame-based radiosurgery (mainly based on Gamma Knife treatments) shows that, while a mean dose of 140 Gy has been effectively used, toxicity increases with higher doses. Moreover the minimal effective dose has never been reported [8, 10, 15, 25 ].
Based on the fact that the 3D dose distribution with Gamma Knife shows some subtle but substantial differences with the Cyberknife, the investigators chose a lower prescription dose compared to the literature data when performing our first attempts to treat movement disorders.
Particularly the prescription dose as the minimum effective dose for a functional disorder such as trigeminal neuralgia was identified.
At that time no previous CyberKnife experiences had been reported. The first two patients treated at our Institution by using these lower treatment doses (75 and 90 Gy respectively) [28] had remarkably positive results thus bringing us to consider the real relative effectiveness of low doses.
The minimum effective dose to perform a thalamotomy was chosen accordingly , by drawing a dose escalation clinical trial rather than a de-escalation dose protocol.
Particularly, the protocol started with a dose of 75 Gy and reached a dose of 90 Gy.
The analysis of the results from this trial highlighted the absence of tremor control but also confirmed the absolute safety of the selected doses (no reported toxicity).
For this the aim of the present study is to continue the experience to define the minimum effective dose when performing a safe frameless radiosurgical thalamotomy.
Moreover radiosurgery of invisible targets to treat movement disorders and intractable pain are so far still the domain of frame-based procedures, due to the need of a solid reference system registered to the anterior commissure-posterior commissure (AC-PC) line, which allows the use of stereotactic atlases.
In this study the investigators want to confirm the precision of the previously defined mathematical method (that uses atlas-derived stereotactic coordinates) to perform safe frameless radiosurgery of invisible targets.
STUDY DESIGN Longitudinal, interventional study. The project is a dose escalation study (phase II study). The effect of the treatment in term of tremor control will be evaluated.
Particularly, the differences between pre and post-treatment tremor item score will be evaluated.
The radiological (MRI/CT) appearance of a radiation necrosis at the treatment site as well as the toxicities will be also considered.
The study will finish when the 4 dose levels will be delivered.
PRE-TREATMENT EVALUATION Prior medical history and physical examination. Complete history, physical examination including a detailed neurological examination and evaluation of Karnofsky Performance Status will be performed.
The Fahn Tolosa Marin tremor rating scale (FTMTRS) will be assessed for all patients.
The unified Parkinson disease rating scale motor score will be utilize to define the severity of symptoms only in case of Parkinson's disease Unresponsiveness to conservative treatment will be verified. Any prior surgery, prior radiation therapy and/or radiosurgery of the brain will be recorded.
Prior surgery at the site of the lesion, prior radiation therapy and/or radiosurgery of the brain will not prevent the patient from participating in the protocol.
Risk analysis of surgery procedure will be express by a skilled neurological surgeon.
PRE-TREATMENT IMAGING PROCEDURE A 1 mm thickness high quality CT Scan and a dedicated MRI will be always acquired.
When possible a 3tesla MRI will be utilized. The multimodality images will be fused and then exported to the CK treatment planning system (TPS).
CYBERKNIFE RADIOSURGERY The target selection. The preferentially selected target of treatment will be the VoO-VoP nuclei of the Thalamous The choice of VoA (12-13 mm lateral to the midline, 2 mm anterior to the midcommissural point and 2 mm superior to the commissural plane ) was intended to lessen the risk of anatomical variability in these patients. In fact, this target is relatively far from the motor fibres running in the posterior limb of the internal capsule and far from other "eloquent" nuclei.
The VIM nuclei can be considered because the similarity of the main features. Target definition and stereotactic atlas registration of the CT images. During CT scanning it is critical that the patient's head remains in a fixed position in order to avoid movement artefacts. For the patients high-quality images will be obtained by restraining the patient's head using a standard thermoplastic mask and acquiring the images very rapidly, always less than 40 seconds with the CT equipment in our possession (Light Speed Ultra, General Electric, Fairfield, Connecticut, USA). Mild sedation may be necessary in some cases with head tremor. In more severe cases, in which body and/or head movements could prevent an optimal image acquisition, administration of low-dosage of Midazolam under anaesthesiological control is mandatory. If the head is immobile the CT gantry behaves like a solid reference system with fixed relationships to the brain structures. In other words the CT screen may be seen as a bi-dimensional stereotactic frame and each pixel of the CT screen represents a discrete part of the brain identified by X lateral and Y antero-posterior coordinates to the screen origin. The slice containing the anterior commissure (AC) is arbitrarily assigned to depth = 0 (Z coordinate); the depth of each slice is calculated relative to this point (the slices are 1.25 mm thickness). The system calculate the AC X, Y, and Z coordinates (Z = 0) and the coordinates of the posterior commissure (PC) where Z is the distance in mm from slice zero. In cases in which the AC and PC lie on the same slice, AC and PC Z coordinates are both equal zero and the calculations are easier. Finally the values in pixels are converted into millimetres based on the matrix/FOV ratio of the CT screen. In other words X and Y value of each pixel of the brain image on the CT screen are obtained and Z is derived as the depth of the slice measured as the vertical distance from the slice 0. Finally the investigators calculate the coordinates of the AC-PC midpoint, which is the origin of the stereotactic atlas, and a simple rototranslation between the origin of the screen and the origin of the stereotactic atlas allows us to obtain atlas-registered X, Y, and Z coordinates in millimeters of each point on the CT axial brain slices (Fig. 1).
Target coordinates of Voa/Vop complex ( X = +/-12 mm , Y = 2 mm , Z = 2 mm) derived from the stereotactic atlases registered to the mid-commissural point are easily transposed onto the corresponding CT slice and the target is drawn on the treatment planning system (Multiplan, Accuray Inc.). In other words, the axes roto-translation between the CT screen and the commissural system of the patient allows the use of atlas-derived stereotactic coordinates to make the invisible functional target visible. The CT images will be also be fused with MRI to obtain more anatomic details about the anatomical structures surrounding the estimated target.
High quality control of CT couch movements is of course mandatory for the above described procedure and possible undesired movements of the CT couch during the examination could affect the precision of the Z coordinate; even if the Voa/Vop complex is relatively close (slice + 2mm) to the slice containing the anterior commissure (slice 0) , possible errors must be taken into account.
A MRI (1 mm slice, T1 sequence ) will be performed and merged with TC images . Radiosurgical planning. After than the target volume will be identified and the critical normal structures will be contoured, in conjunction with a physicist, inverse planning using the CyberKnife Treatment planning system (TPS) will be performed to yield a treatment plan.
The treatment plan used for each treatment will be based on an analysis of the volumes and doses including dose-volume histogram (DVH) analyses of the PTV and critical normal structures.
Doses selection The aim of this procedure is to cause a lesion confined to the estimated target. The first 2 patient will be treated with a dose of 100 Gy to the 100% isodose line, the 3rd and the 4th patient will be escalated with 120 Gy to the 100% isodose line, the 5th and 6th patient will be treated with 130 Gy to the 100% isodose line and then the dose will be escalated to140 Gy will be utilized (7th and 8th).
Treatment will be delivered as a single shot radiosurgery.
PATIENT ASSESSMENTS Evaluation During Treatment Patients will be seen and evaluated during CyberKnife radiosurgery with documentation of tolerance, including acute reaction.
Evaluation Following Treatment Patients will be followed as follows 3, 6, 12, 18 and 24 months after radiosurgery Images (CT and/or MRI) will be performed and the modification of target size will be measured.
The FTMTRS and/or UPDRS score will be assessed. At each follow-up visits, toxicity will be evaluated and documented Criteria for tremor response The tremor control assessment will be based on the quantitative/qualitative analysis of pre and post-treatment tremor rating scale score/graphical features.
The quantitative analysis will be based on the numerical differences between pre and post-treatment FTMTRS score.
The qualitative analysis was mainly based on the visual judgement of the Jancovich spiral drawing from the FTMTRS..
UPDRS motor will be also evaluated for patients affected by Parkinson Disease (PD).
DISEASE RELATED DRUG ADMINISTRATION DURING THE TREATMENT AND FOLLOW-UP PERIOD Levodopa equivalent daily dosage (LEDD) will be tentatively maintained during all the observation period. LEDD could be modified for a relevant worsening of symptoms (akinesia and/or rigidity not for tremor).
STATISTICAL CONSIDERATION Descriptive statistic (mean, percentage, frequency, etc.) will be performed on quantitative variables
ADVERSE EVENTS AND RADIOSURGERY TOXICITY Adverse events will be graded and registered according to National Cancer Institute, Common Terminology Criteria for Adverse Events (NCI-CTCAE) version 4.
Serious Adverse Event stopping criteria. The study will be closed if more than 2 patients will show a serious adverse events related to or suspected for a relation with the treatment.
DATA COLLECTION Patients will be allocated a number and their data will be collected on a Case Report Forms. Data will include information from each protocol visit and will be completed on a timely manner.
- Conditions
- Tremor, Limb
- Being tested
- Thalamotomy
- Keywords
- Deep Brain, Essential tremor, Parkinson Disease, Tremor, Radiosurgery, Thalamotomy, deep brain stimulation, DBS, intractable, drug resistant, invalidating tremor
- Medical subject headings
- Tremor, Essential Tremor, Parkinson Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ThalamotomyRadiation
VoA-Vop complex of the thalamous or VIM nucleus will be targeted. 100 Gy, 120 Gy, 130 Gy, 140 Gy will be the foreseen prescription dose. CyberKnife will be always used to perform the procedure.
| Study group | Role | What they receive |
|---|---|---|
| Radiosurgical thalamotomy | Other | Patients will undergo to radiosurgical thalamotomy by Cyberknife system. Receives: Radiation: Thalamotomy |
What is being measured
The primary outcome is the main question the study is designed to answer.
Minimun effective dose (presence/absence of visible MRI thalamotomy)
The aim of this study is to define the minimum effective dose to obtain a tremor control
Measured: 18 months
Secondary outcomes (2)
Targeting validation (post treatment thalamotomy merge the target plan)
Targeting methodology validation (the lesions position, if present, will be compared to the treatment plan target position, deviations will be registered).
Measured: 18 months
Toxicity (according to NCI CTCAE v4.0)
Number and grade of adverse events
Measured: 24 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Oct 2015 (estimated)
- Study startMay 2015
- Primary completion31 Dec 2021
- Study completion31 Dec 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Tremor, LimbStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 8 participants (actual)
Sponsor and investigators
- Lead sponsor
- Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Marcello Marchetti, MD, Principal investigator, Fondazione Irccs Istituto Neurologico Carlo Besta
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02585583
- Sponsor's protocol ID
- PR DB RS2
- Acronym
- PRDBRS2
- Status last verified
- Feb 2020
- First submitted
- 15 Oct 2015
- Last updated
- 8 Nov 2024
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Nov 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Deep Brain Frameless Radiosurgery for Drug Resistant Invalidating Tremor. Dose Escalation Pilot Study
- ClinicalTrials.gov ID
- NCT02585583
- Acronym / sponsor ID
- PRDBRS2 / PR DB RS2
- Conditions
- Tremor, Limb
- Keywords
- Deep Brain, Essential tremor, Parkinson Disease, Tremor, Radiosurgery, Thalamotomy, deep brain stimulation, DBS
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 8 participants (actual)
- Lead sponsor
- Fondazione I.R.C.C.S. Istituto Neurologico Carlo BestaUniversity, hospital or other
- Study start
- May 2015 (actual)
- Primary completion
- 31 Dec 2021 (actual)
- Study completion
- 31 Dec 2021 (actual)
- First posted
- 23 Oct 2015 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The gamma knife radiosurgical thalamotomy to treat many movement disorders is recently becoming a new and well defined treatment paradigm.
The CyberKnife if compared to the frame-based radiosurgery, is a pain free procedure which offers the advantage of a better patient's compliance by avoiding local anaesthesia and the discomfort due to wearing the frame for the period of time needed for the whole procedure.
Unfortunately the subtle but substantial differences about the 3D dose distribution and the dose fall-off features between GK and CK made mandatory investigations about the effectiveness and the safety when the cyberknife is used.
Particularly the minimum effective and safety dose have to be defined yet A previous study (NCT02095600) failed in demonstrating the efficacy of 75 Gy, 80 Gy, 90 Gy.
The aim of the present study is to investigate about the effectiveness of 100 Gy, 120 Gy, 130 Gy and 140 Gy.
The safety and the targeting methodology will be also in investigated.
Detailed description
BACKGROUND The stereotactic lesioning of thalamus and basal ganglia for the treatment of tremor is a well-known procedure which, before the introduction of deep brain stimulation ( DBS), was usually performed using stereotactic surgical procedures.[16] Consistent positive experience in functional radiosurgery using the Gamma Knife or linear accelerators was reported since the first report by Leksell in 1951.[4, 8, 11, 13, 14, 17, 18, 19, 21, 24, 25, 26, 27] CyberKnife (CK), (Accuray Inc., Sunnyvale, California, USA) allows a real frameless stereotactic radiosurgery of recognizable intracranial targets such as arteriovenous malformations (AVMs), tumours, and trigeminal nerve for the treatment of trigeminal neuralgia.[1, 2, 3, 7, 9, 23] When compared to the frame-based radiosurgery , frameless radiosurgery is a pain free procedure which offers the advantage of a better patient's compliance by avoiding local anaesthesia and the discomfort due to wearing the frame for the period of time needed for the whole procedure.
The present literature on functional frame-based radiosurgery (mainly based on Gamma Knife treatments) shows that, while a mean dose of 140 Gy has been effectively used, toxicity increases with higher doses. Moreover the minimal effective dose has never been reported [8, 10, 15, 25 ].
Based on the fact that the 3D dose distribution with Gamma Knife shows some subtle but substantial differences with the Cyberknife, the investigators chose a lower prescription dose compared to the literature data when performing our first attempts to treat movement disorders.
Particularly the prescription dose as the minimum effective dose for a functional disorder such as trigeminal neuralgia was identified.
At that time no previous CyberKnife experiences had been reported. The first two patients treated at our Institution by using these lower treatment doses (75 and 90 Gy respectively) [28] had remarkably positive results thus bringing us to consider the real relative effectiveness of low doses.
The minimum effective dose to perform a thalamotomy was chosen accordingly , by drawing a dose escalation clinical trial rather than a de-escalation dose protocol.
Particularly, the protocol started with a dose of 75 Gy and reached a dose of 90 Gy.
The analysis of the results from this trial highlighted the absence of tremor control but also confirmed the absolute safety of the selected doses (no reported toxicity).
For this the aim of the present study is to continue the experience to define the minimum effective dose when performing a safe frameless radiosurgical thalamotomy.
Moreover radiosurgery of invisible targets to treat movement disorders and intractable pain are so far still the domain of frame-based procedures, due to the need of a solid reference system registered to the anterior commissure-posterior commissure (AC-PC) line, which allows the use of stereotactic atlases.
In this study the investigators want to confirm the precision of the previously defined mathematical method (that uses atlas-derived stereotactic coordinates) to perform safe frameless radiosurgery of invisible targets.
STUDY DESIGN Longitudinal, interventional study. The project is a dose escalation study (phase II study). The effect of the treatment in term of tremor control will be evaluated.
Particularly, the differences between pre and post-treatment tremor item score will be evaluated.
The radiological (MRI/CT) appearance of a radiation necrosis at the treatment site as well as the toxicities will be also considered.
The study will finish when the 4 dose levels will be delivered.
PRE-TREATMENT EVALUATION Prior medical history and physical examination. Complete history, physical examination including a detailed neurological examination and evaluation of Karnofsky Performance Status will be performed.
The Fahn Tolosa Marin tremor rating scale (FTMTRS) will be assessed for all patients.
The unified Parkinson disease rating scale motor score will be utilize to define the severity of symptoms only in case of Parkinson's disease Unresponsiveness to conservative treatment will be verified. Any prior surgery, prior radiation therapy and/or radiosurgery of the brain will be recorded.
Prior surgery at the site of the lesion, prior radiation therapy and/or radiosurgery of the brain will not prevent the patient from participating in the protocol.
Risk analysis of surgery procedure will be express by a skilled neurological surgeon.
PRE-TREATMENT IMAGING PROCEDURE A 1 mm thickness high quality CT Scan and a dedicated MRI will be always acquired.
When possible a 3tesla MRI will be utilized. The multimodality images will be fused and then exported to the CK treatment planning system (TPS).
CYBERKNIFE RADIOSURGERY The target selection. The preferentially selected target of treatment will be the VoO-VoP nuclei of the Thalamous The choice of VoA (12-13 mm lateral to the midline, 2 mm anterior to the midcommissural point and 2 mm superior to the commissural plane ) was intended to lessen the risk of anatomical variability in these patients. In fact, this target is relatively far from the motor fibres running in the posterior limb of the internal capsule and far from other "eloquent" nuclei.
The VIM nuclei can be considered because the similarity of the main features. Target definition and stereotactic atlas registration of the CT images. During CT scanning it is critical that the patient's head remains in a fixed position in order to avoid movement artefacts. For the patients high-quality images will be obtained by restraining the patient's head using a standard thermoplastic mask and acquiring the images very rapidly, always less than 40 seconds with the CT equipment in our possession (Light Speed Ultra, General Electric, Fairfield, Connecticut, USA). Mild sedation may be necessary in some cases with head tremor. In more severe cases, in which body and/or head movements could prevent an optimal image acquisition, administration of low-dosage of Midazolam under anaesthesiological control is mandatory. If the head is immobile the CT gantry behaves like a solid reference system with fixed relationships to the brain structures. In other words the CT screen may be seen as a bi-dimensional stereotactic frame and each pixel of the CT screen represents a discrete part of the brain identified by X lateral and Y antero-posterior coordinates to the screen origin. The slice containing the anterior commissure (AC) is arbitrarily assigned to depth = 0 (Z coordinate); the depth of each slice is calculated relative to this point (the slices are 1.25 mm thickness). The system calculate the AC X, Y, and Z coordinates (Z = 0) and the coordinates of the posterior commissure (PC) where Z is the distance in mm from slice zero. In cases in which the AC and PC lie on the same slice, AC and PC Z coordinates are both equal zero and the calculations are easier. Finally the values in pixels are converted into millimetres based on the matrix/FOV ratio of the CT screen. In other words X and Y value of each pixel of the brain image on the CT screen are obtained and Z is derived as the depth of the slice measured as the vertical distance from the slice 0. Finally the investigators calculate the coordinates of the AC-PC midpoint, which is the origin of the stereotactic atlas, and a simple rototranslation between the origin of the screen and the origin of the stereotactic atlas allows us to obtain atlas-registered X, Y, and Z coordinates in millimeters of each point on the CT axial brain slices (Fig. 1).
Target coordinates of Voa/Vop complex ( X = +/-12 mm , Y = 2 mm , Z = 2 mm) derived from the stereotactic atlases registered to the mid-commissural point are easily transposed onto the corresponding CT slice and the target is drawn on the treatment planning system (Multiplan, Accuray Inc.). In other words, the axes roto-translation between the CT screen and the commissural system of the patient allows the use of atlas-derived stereotactic coordinates to make the invisible functional target visible. The CT images will be also be fused with MRI to obtain more anatomic details about the anatomical structures surrounding the estimated target.
High quality control of CT couch movements is of course mandatory for the above described procedure and possible undesired movements of the CT couch during the examination could affect the precision of the Z coordinate; even if the Voa/Vop complex is relatively close (slice + 2mm) to the slice containing the anterior commissure (slice 0) , possible errors must be taken into account.
A MRI (1 mm slice, T1 sequence ) will be performed and merged with TC images . Radiosurgical planning. After than the target volume will be identified and the critical normal structures will be contoured, in conjunction with a physicist, inverse planning using the CyberKnife Treatment planning system (TPS) will be performed to yield a treatment plan.
The treatment plan used for each treatment will be based on an analysis of the volumes and doses including dose-volume histogram (DVH) analyses of the PTV and critical normal structures.
Doses selection The aim of this procedure is to cause a lesion confined to the estimated target. The first 2 patient will be treated with a dose of 100 Gy to the 100% isodose line, the 3rd and the 4th patient will be escalated with 120 Gy to the 100% isodose line, the 5th and 6th patient will be treated with 130 Gy to the 100% isodose line and then the dose will be escalated to140 Gy will be utilized (7th and 8th).
Treatment will be delivered as a single shot radiosurgery.
PATIENT ASSESSMENTS Evaluation During Treatment Patients will be seen and evaluated during CyberKnife radiosurgery with documentation of tolerance, including acute reaction.
Evaluation Following Treatment Patients will be followed as follows 3, 6, 12, 18 and 24 months after radiosurgery Images (CT and/or MRI) will be performed and the modification of target size will be measured.
The FTMTRS and/or UPDRS score will be assessed. At each follow-up visits, toxicity will be evaluated and documented Criteria for tremor response The tremor control assessment will be based on the quantitative/qualitative analysis of pre and post-treatment tremor rating scale score/graphical features.
The quantitative analysis will be based on the numerical differences between pre and post-treatment FTMTRS score.
The qualitative analysis was mainly based on the visual judgement of the Jancovich spiral drawing from the FTMTRS..
UPDRS motor will be also evaluated for patients affected by Parkinson Disease (PD).
DISEASE RELATED DRUG ADMINISTRATION DURING THE TREATMENT AND FOLLOW-UP PERIOD Levodopa equivalent daily dosage (LEDD) will be tentatively maintained during all the observation period. LEDD could be modified for a relevant worsening of symptoms (akinesia and/or rigidity not for tremor).
STATISTICAL CONSIDERATION Descriptive statistic (mean, percentage, frequency, etc.) will be performed on quantitative variables
ADVERSE EVENTS AND RADIOSURGERY TOXICITY Adverse events will be graded and registered according to National Cancer Institute, Common Terminology Criteria for Adverse Events (NCI-CTCAE) version 4.
Serious Adverse Event stopping criteria. The study will be closed if more than 2 patients will show a serious adverse events related to or suspected for a relation with the treatment.
DATA COLLECTION Patients will be allocated a number and their data will be collected on a Case Report Forms. Data will include information from each protocol visit and will be completed on a timely manner.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Radiosurgical thalamotomy | Other | Radiation: ThalamotomyPatients will undergo to radiosurgical thalamotomy by Cyberknife system. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Patients affected by severe upper limb tremor refractory to medical therapy and who are less than optimal candidate for a deep brain stimulation (DBS) procedure.
- Age ≥ 18 years old
- Refusal of DBS procedure
- Written consent
Key exclusion criteria (3 listed)
- Pregnancy
- CT/MRI contraindication
- Illiteracy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ThalamotomyVoA-Vop complex of the thalamous or VIM nucleus will be targeted. 100 Gy, 120 Gy, 130 Gy, 140 Gy will be the foreseen prescription dose. CyberKnife will be always used to perform the procedure. | Radiation | Radiosurgical thalamotomy |
Primary outcome
Minimun effective dose (presence/absence of visible MRI thalamotomy)
Time frame: 18 months
The aim of this study is to define the minimum effective dose to obtain a tremor control
2 secondary outcomes
Targeting validation (post treatment thalamotomy merge the target plan)
Time frame: 18 months
Toxicity (according to NCI CTCAE v4.0)
Time frame: 24 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Nov 2024.
Related trials for Tremor, Limb
RecruitingPhase 2
Study of AGN-151607-DP to Assess Adverse Events and Change in Disease Activity in Adult Participants With Upper Limb Essential Tremor
Upper Limb Essential Tremor
RecruitingPhase 1
Coordinated Reset Deep Brain Stimulation for Essential Tremor
Essential Tremor, Upper Extremity Essential Tremor
RecruitingObservational study
Wearable for Assessing Tremor and Continuous Health in Parkinson's Disease and Essential Tremor
PARKINSON DISEASE (Disorder)
Not yet recruitingPhase 3
Effect of Botulinum Toxin on Resting Tremor of the Refractory Upper Limb in Parkinsonians
PARKINSON DISEASE (Disorder)
Active, not recruitingPhase 4
Factors Determining the Efficacy of Botulinum Toxin for Arm Tremor in Dystonia
Dystonic Tremor Syndrome
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Marcello Marchetti, MD principal investigator
Fondazione Irccs Istituto Neurologico Carlo Besta
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Thalamotomy in people with Tremor, Limb, run by Fondazione I.R.C.C.S. Istituto Neurologico Carlo Besta at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 8 Nov 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Minimun effective dose (presence/absence of visible MRI thalamotomy) (time frame: 18 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Nov 2024.