Atrial FibrillationCOR-ADVANCENCT02588183

PV Cryoablation Efficacy (COR ADVANCE Study)

A study testing ArticFont Advance ST Cryoenergy Balloon Catheter in people with Atrial Fibrillation, run by Hospital San Carlos, Madrid at 1 site in Spain.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The COR advance study is a non-randomized prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF. Read more about this study

Who is it for?
Ages 18 to 75 years
Conditions the study is for
Atrial Fibrillation
What is being tested?
ArticFont Advance ST Cryoenergy Balloon Catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteSpain
Study dates
Aug 2015to 22 Mar 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Symptomatic recurrent paroxysmal AF
  • >2 episodes in the last 6 months
  • Refractory to 1 or more antiarrhythmic drugs
  • Anatomical pattern consisting of 4 pulmonary veins
  • Willing and capable of providing informed consent

Who cannot join

  • Patients that are <18 or >75 years old
  • Prior AF ablation
  • Prior cardiac surgery
  • Moderate to severe valvular heart disease
  • Anteroposterior diameter of the left atrium >50 mm
  • Hyperthyroidism, intracardiac thrombus, contraindications for anticoagulation, concomitant acute illness, pregnancy.
  • Unavailability for follow-up at our center for at least 1 year

Trial locations and contacts

1 site in 1 country.

Spain1 site
  • Unidad de Arritmias, Hospital Clínico San Carlos

    Madrid, 28040

Other trials in Spain

About this study

Official title: PV Cryoablation Efficacy Using Electrophysiological Endpoints and the New Generation ArticFont Advance ST Catheter (COR ADVANCE Study)

The COR advance study is a non-randomized prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF.

Methods Patient selection criteria will be the same that in the original COR study. All patients will be followed with a Reveal LINQ® cardiac monitor that will be implanted before ablation. The primary objective is the proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation. Secondary objectives are: AF-free survival without anti arrhythmic drugs 12 months after ablation, cumulative AF burden (number of AF episodes and percentage of time in AF) 12 months after ablation, percentage of the pulmonary veins with bidirectional block at the end of the procedure, and ablation time (from the onset of the first energy delivery to the end of the last energy delivery), procedure time (from femoral puncture to catheter removal), and fluoroscopy time.

Final results will be known 24 months after the first enrollment. Statistical analysis Continuous variables that are distributed normally according to the Shapiro-Wilk test will be presented as the mean [standard deviation], and the values will be compared with the t test. Continuous variables that do not follow a normal distribution will be presented as the median [25th to 75th percentile] and will be compared with the Mann-Whitney U test. Categorical variables between two groups with expected values <5 will be compared with the Fisher exact test. Otherwise, categorical variables will be compared with the chi-squared test. The AF-free survival functions will be represented as Kaplan-Meier curves. Data analyses will be done with JMP® (version 9.0.1, SAS Institute Inc., Cary, NC, USA) and Stata® (version 11.0, StataCorp LP; College Station, TX, USA).

Read the detailed description

Background The Cryoenergy Or Radiofrequency [COR] trial is a randomized, single-center study that compared the efficacy of a anatomical simplified strategy for pulmonary vein cryoballoon ablation (2 shots per PV, 1 first-generation Arctic Front® catheter per patient and no additional touch-up applications to close residual gaps) versus the standard technique for pulmonary vein isolation using open-irrigated radiofrequency catheters (Navistar Thermocool®) with electrophysiological (Lasso®) and electroanatomical guidance (Carto 3®) in 50 patients with drug-refractory paroxysmal atrial fibrillation. All patients were followed with an implantable cardiac monitor (Reveal XT®).

The primary endpoint of the study (proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation) was met by 48% of patients treated with cryoenergy and 68% of patients treated with radiofrequency (OR 0.43 [95% confidence interval, 0.19 to 1.0]; P=0.05). This difference disappeared after adjustment for acute procedural outcome. In patients for whom all 4 PVs were blocked at the end of the procedure, there was no difference between group C and group R in the primary endpoint (67% versus 68%; P=0.94). Thus, the COR trial supports that: 1) complete PV conduction block is critical to the success of AF ablation; 2) despite the fact that the results of the anatomical cryoablation technique used in the COR study are superior to the previously published series of patients treated with PV cryoablation and followed by implantable monitors, results of cryoablation might be even better if we aim for PV conduction block. At present time, the availability of the Achieve® mapping catheter and the more efficient 2nd-generation cryoballoon ArcticFront Advance® catheter provides an opportunity to test a electrophysiologically guided PV cryoablation approach against conventional PV isolation with point-by-point radiofrequency ablation catheters.

The COR advance study is a non-randomized observational prospective single center study to assess the results of an electrophysiologically guided approach for PV cryoablation using the Arctic Front Advance ST® catheter together with the Achieve® mapping catheter in 25 patients with drug-refractory paroxysmal AF.

Methods

Inclusion criteria:

  • Symptomatic recurrent paroxysmal AF
  • >2 episodes in the last 6 months
  • Refractory to 1 or more antiarrhythmic drugs
  • Anatomical pattern consisting of 4 pulmonary veins
  • Willing and capable of providing informed consent

Exclusion criteria:

  • Patients that are <18 or >75 years old
  • Prior AF ablation
  • Prior cardiac surgery
  • Moderate to severe valvular heart disease
  • Anteroposterior diameter of the left atrium >50 mm
  • Hyperthyroidism, intracardiac thrombus, contraindications for anticoagulation, concomitant acute illness, pregnancy.
  • Unavailability for follow-up at our center for at least 1 year

All procedures will be performed in the Arrhythmia Unit of our Institution. Patients will need to give written informed consent to be enrolled in this study. Pre-procedural exams and pre-ablation technique will be the same that used in the COR trial. The end point of PV cryoablation will be complete bidirectional PV conduction block assessed with the Achieve® catheter. Only one ArcticFront Advance® or ArcticFront Advance ST® catheter (23 or 28 mm diameter) will be used per patient. Every cryoenergy delivery will last 240 seconds, except in case of excessive freezing (temperature ≤-65ºC with a 23 mm balloon or ≤-60º with a 28 mm balloon), diaphragmatic hypokinesia or other significant adverse event related to freezing. No bonus applications will be given if the time to effect is less than 60 seconds with a 23-mm cryoballoon catheter, or less than 90 seconds with a 28-mm cryoballoon. When the time to effect cannot be assessed, no bonus applications will be given provided that there is complete occlusion of the PV during freezing (persistent contrast staining of the PV) and the application results in PV conduction block. Otherwise, either late PV conduction block or incomplete PV occlusion during freezing will need a bonus cryoenergy delivery. If PV conduction block is not achieved, one or more additional cryoenergy applications will be given at discretion of the responsible physician. Thus, the number of cryoenergy applications will not be limited by protocol, but the use of a different size cryoballoon or conventional point-by-point ablation catheters is strongly discouraged.

Patient selection criteria will be the same that in the original COR study. All patients will be followed with a Reveal LINQ® cardiac monitor that will be implanted before ablation. The primary objective is the proportion of patients remaining free from atrial fibrillation recurrences without taking antiarrhythmic drugs 12 months after ablation. Secondary objectives are: AF-free survival without anti arrhythmic drugs 12 months after ablation, cumulative AF burden (number of AF episodes and percentage of time in AF) 12 months after ablation, percentage of the pulmonary veins with bidirectional block at the end of the procedure, and ablation time (from the onset of the first energy delivery to the end of the last energy delivery), procedure time (from femoral puncture to catheter removal), and fluoroscopy time.

Final results will be known 24 months after the first enrollment.

Statistical analysis Continuous variables that are distributed normally according to the Shapiro-Wilk test will be presented as the mean [standard deviation], and the values will be compared with the t test. Continuous variables that do not follow a normal distribution will be presented as the median [25th to 75th percentile] and will be compared with the Mann-Whitney U test. Categorical variables between two groups with expected values <5 will be compared with the Fisher exact test. Otherwise, categorical variables will be compared with the chi-squared test. The AF-free survival functions will be represented as Kaplan-Meier curves. Data analyses will be done with JMP® (version 9.0.1, SAS Institute Inc., Cary, NC, USA) and Stata® (version 11.0, StataCorp LP; College Station, TX, USA).

Being tested
ArticFont Advance ST Cryoenergy Balloon Catheter
Keywords
atrial fibrillation, catheter ablation, pulmonary vein, cryoenergy, cryoablation, ArcticFront
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ArticFont Advance ST Cryoenergy Balloon CatheterDevice

    PV isolation using the ArticFont Advance ST Cryoenergy Balloon Catheter

Study groups in NCT02588183
Study groupRoleWhat they receive
ArticFont Advance STExperimentalPatients undergoing PV isolation with the ArticFont Advance ST Cryoenergy Balloon Catheter
Receives: Device: ArticFont Advance ST Cryoenergy Balloon Catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Proportion of patients free-from AF, without antiarrhythmic drug therapy

    Measured: 12 months

Secondary outcomes (4)
  1. AF-free survival, without antiarrhythmic drug therapy

    Measured: 12 months

  2. Proportion of PV with bidirectional block

    Measured: intraoperative

  3. Time required to complete isolation (LA time)

    Measured: intraoperative

  4. Cumulative AF burden

    Percentage of time in AF (%) and number of AF episodes (n)

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Oct 2015 (estimated)
  2. Study startAug 2015
  3. Primary completionMar 2017
  4. Study completion22 Mar 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02588183
Sponsor's protocol ID
AF-3064: COR ADVANCE Study
Acronym
COR-ADVANCE
Status last verified
Jun 2018
First submitted
26 Oct 2015
Last updated
8 Jun 2018
Results posted
No
Data monitoring committee
No

Publications

  • Perez-Castellano N, Fernandez-Cavazos R, Moreno J, Canadas V, Conde A, Gonzalez-Ferrer JJ, Macaya C, Perez-Villacastin J. The COR trial: a randomized study with continuous rhythm monitoring to compare the efficacy of cryoenergy and radiofrequency for pulmonary vein isolation. Heart Rhythm. 2014 Jan;11(1):8-14. doi: 10.1016/j.hrthm.2013.10.014. Epub 2013 Oct 5.

    PubMed 24103221

Questions about this trial

What is this clinical trial studying?

A study testing ArticFont Advance ST Cryoenergy Balloon Catheter in people with Atrial Fibrillation, run by Hospital San Carlos, Madrid at 1 site in Spain.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Jun 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Proportion of patients free-from AF, without antiarrhythmic drug therapy (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02588183, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jun 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in